kiasma fall pipe vessels
TRANSCRIPT
8/17/2019 Kiasma Fall Pipe Vessels
http://slidepdf.com/reader/full/kiasma-fall-pipe-vessels 1/8
FALL PIPE
KIASMAGroup
Solution A: flexible HDPE pipes
Solution B: flexible HDPE pipes with GRP
8/17/2019 Kiasma Fall Pipe Vessels
http://slidepdf.com/reader/full/kiasma-fall-pipe-vessels 2/8
KIASMA SRL via M. Adamello 31/H 31059 Zero Branco (TV) ITALY tel. 0039 0422 97620 fax 0039 0422 48744
www.kiasmasrl.it [email protected]
FLEXIBLE FALL PIPE VESSELS
K I A S M A
8/17/2019 Kiasma Fall Pipe Vessels
http://slidepdf.com/reader/full/kiasma-fall-pipe-vessels 3/8
KIASMA SRL via M. Adamello 31/H 31059 Zero Branco (TV) ITALY tel. 0039 0422 97620 fax 0039 0422 48744
www.kiasmasrl.it [email protected]
Enclosed we are sending you two technical proposals for HDPE pipes for the “ Flexible
Fall Pipe Wessels” application.
We furthermore invite you to personally visit our production unit in Italy where we have 9
lines daily manufacturing HDPE pipes.
Solution A : Offer of HDPE pipe with steel cone
The particular nature of the material that will be discharged inside the pipes ( rock
dumping, ex rock Eclogite ) forced us to be very uncompromising with the type of polymer that we would have to use for the production of these pipes.
Our offer proposes pipe made of virgin HDPE PE 100, EN12201 – ASTM4710 PLUS –
Type BL, very resistant to crack test which also prevents the propagation of the fractures.
K I A S M A
8/17/2019 Kiasma Fall Pipe Vessels
http://slidepdf.com/reader/full/kiasma-fall-pipe-vessels 4/8
Solution B: Offer of HDPE pipe with GRP and steel cone
The pipeline in HDPE – Type BL ( crack resistant ) is externally coated with a layer of
GPR ( Glass Reinforced Plastic ) processed by Filament winding.
- INNER LAYER IN HDPE PE100 Type BL = resistant to cracks propagation and
abrasion
- OUTER LAYER IN GRP = Filament winding
The fall pipe is constantly full of water. This fact help to counteract the negative
hydrostatic pressure acting externally on the circumference of the pipe.
It’s therefore suggested to always execute the Buckling Test Verification and obtain a
safety coefficient > 1 ( see enclosed file ).
With the characteristic of the HDPE pipe you required we obtain a safety coefficient of 0,3.
To obtain a coefficient >1 we have to coat the HDPE pipes with an external layer of GRP
also obtaining a reduced bending of the pipe.
OUTER LAYER IN GRP= Resistant to high pressures , resistant to shocks and
compensate for the intrinsic flexibility of the polyethylene pipeline.
The GRP outer layer Filament Winding, not subject to the attack of salt water, provides
high pressures and shocks resistance to conduct.
GRP thickness which is wrapped the HDPE pipe is designed according to the needs of
the yard work and responding to regulations ISO,EN,ASTM,ANSI, AWWA.
The possibility to vary the angle of wrapping of the glass (main component that ensures
the mechanical resistance of the product) allows pipes which have a modulus of axial
elasticity or circumferential the most appropriate to the application request
KIASMA SRL via M. Adamello 31/H 31059 Zero Branco (TV) ITALY tel. 0039 0422 97620 fax 0039 0422 48744
www.kiasmasrl.it [email protected]
K I A S M A
8/17/2019 Kiasma Fall Pipe Vessels
http://slidepdf.com/reader/full/kiasma-fall-pipe-vessels 5/8
KIASMA SRL via M. Adamello 31/H 31059 Zero Branco (TV) ITALY tel. 0039 0422 97620 fax 0039 0422 48744
www.kiasmasrl.it [email protected]
Average values for the principal physical-mechanical properties of laminated in Filament
Winding:
breaking load traction circumferential : 2000 ÷ 4000 Kg/cm2
breaking load axial tensile : 400 ÷ 1200 Kg/cm2
elastic modulus traction circumferential : 100000 ÷ 300000 Kg/cm2
elastic modulus axial tensile: 50000 ÷ 125000 Kg/cm2
breaking load cut : 600 Kg/cm2
breaking load of compression : 2200 Kg/cm2
specific weight: 1,9
coefficient of linear expansion: 20,10 m/m °C
resilience : 220 Kg/ cm/cm2
electrical resistivity: 10 ohm cm
thermal conductivity: 0,2 Kca l/ (m2 h °C)
Pipeline “HDPE +GRP SYSTEM”
K I A S M A
8/17/2019 Kiasma Fall Pipe Vessels
http://slidepdf.com/reader/full/kiasma-fall-pipe-vessels 6/8
JUNCTION SYSTEM
The junction is carried out by flanging.
The flat base of the stub flange is the location for the seal, o-ring
The joint between tube and tube, occurs between in polyethylene surfaces in order to
maintain the continuity of the line.
The layer of GRP cover the pipe and the welding between the pipe and stub end, and gets
to the flange.
KIASMA SRL via M. Adamello 31/H 31059 Zero Branco (TV) ITALY tel. 0039 0422 97620 fax 0039 0422 48744
www.kiasmasrl.it [email protected]
K I A S M A
8/17/2019 Kiasma Fall Pipe Vessels
http://slidepdf.com/reader/full/kiasma-fall-pipe-vessels 7/8
KIASMA SRL via M. Adamello 31/H 31059 Zero Branco (TV) ITALY tel. 0039 0422 97620 fax 0039 0422 48744
www.kiasmasrl.it [email protected]
JOINT SYSTEM BETWEEN THE PIPES
To help the joint of the pipes they have a cone on top of them
For the joint of the pipes in HDPE + GRP system the joint is the same.
A flanged cone from one side joins the flange of the pipe and the other side is conical with
an angle dimension able to fit the upper pipe and allow the inclination of it of 15 – 20°
avoiding the upper pipe to get out of its position.
K I A S M A
8/17/2019 Kiasma Fall Pipe Vessels
http://slidepdf.com/reader/full/kiasma-fall-pipe-vessels 8/8
K I A S M A
KIASMA SRL via M. Adamello 31/H 31059 Zero Branco (TV) ITALY tel. 0039 0422 97620 fax 0039 0422 48744
www.kiasmasrl.it [email protected]
Annexed: