k15k15 signaling analyzer instruction
TRANSCRIPT
-
7/30/2019 K15K15 Signaling Analyzer Instruction
1/19
z z select the protocol stack
1K15K15K15 Protocol
Tester
K15 Will start protocol analyzer programme automatically after power on K15,also can start
programme by K15 Protocol Tester of desktop or of menu
2
Load
After running programmeprompt need installation of system configuration filesif dont do
the other configuration filesselect the default valueclick load and continue
-
7/30/2019 K15K15 Signaling Analyzer Instruction
2/19
3NO
YES
Previously system record the test data files automaticallyit will prompt need overwrite the
dataclick NOif need to clear away the old recordthen click yes.
4 ISUP
The program enters the following interface automatically; notice that now using the ISUP
protocol stack, the protocol stack and the bit stream are not necessarily required.
-
7/30/2019 K15K15 Signaling Analyzer Instruction
3/19
51
2ON
OFF ON OFF
Before exchange protocol stack, you need to stop the current testing processSee Figure 1
shows the red mark of the toolbar, click the button, the original stream tracking interface will
be switched to the scene configuration interface, click on the map the red mark 2, the ON
status switch to offline state, only in this scene that all of the ON state have change to offline
state system can modify the protocol
stack.
-
7/30/2019 K15K15 Signaling Analyzer Instruction
4/19
OFFLINE
After offlinethe status is as follow
-
7/30/2019 K15K15 Signaling Analyzer Instruction
5/19
6
E1 ISUP
MAP Browse
See the following top-left corner of the red box, and click the left mouse button, then it will
pop up the following interfaceprovide modified protocol stack and the collection slot, E1 and
other parameters. Can see that in this environment the default protocol is stack ISUP, now we need
to test MAP, click Browse, a list will pop up the stack to choose from.
-
7/30/2019 K15K15 Signaling Analyzer Instruction
6/19
7 IS41D OK
In protocol stack found in the following IS41D protocol stack, click OK to confirm. If need to
test other protocols, please choose another protocol stack.
-
7/30/2019 K15K15 Signaling Analyzer Instruction
7/19
8 Apply Logical Links of
Scenario is41d Close
After Selected protocol stack, only click Apply can the protocol stack take into effect, you can
see from the chart in the Logical Links of Scenario list has been revised to is41d agreement,
click Close to close thewindow.
-
7/30/2019 K15K15 Signaling Analyzer Instruction
8/19
9 ONMonitor
Currently We only need watch signaling from a monitorset the branch switch of the monitor to ON, then double-click the Monitoricon then return to the signaling stream interface.
-
7/30/2019 K15K15 Signaling Analyzer Instruction
9/19
z z filter Signaling
1 MPT2
By default, the signaling device reported a lot of MPT2 and the other signaling which we do not care about, need to use the filters to filter the
signaling which do not need too much concern.
-
7/30/2019 K15K15 Signaling Analyzer Instruction
10/19
2 Filter
click the F ilter of the data flow diagram, you can open the filter configuration interface.
3 Protocols
-
7/30/2019 K15K15 Signaling Analyzer Instruction
11/19
Well, let us select the Protocols page, the following screen appears.
4 Bypass Protocol Filter
Bypass Protocol Filter to remove the front Komagari hook, found? Filter can be chosen in
agreement!
-
7/30/2019 K15K15 Signaling Analyzer Instruction
12/19
5MAP Protocols
OK
In this case we only care about MAP message, click the Protocols in the little green box, when its color turn to yellow, the protocol
analyzercan not see a message which is in yellow color, click OK to close the page.
-
7/30/2019 K15K15 Signaling Analyzer Instruction
13/19
6MAP
Now in the signaling device we will only see the MAP massages.
-
7/30/2019 K15K15 Signaling Analyzer Instruction
14/19
z z Save signaling
1 Shift Ctrl
Select thesignaling which needs to be saved, you can use Shift and Ctrl to achieve multi_select.
2 Save Marked Frames As
Single right-clickin the menu that appears, select Save Marked Frames As ...
-
7/30/2019 K15K15 Signaling Analyzer Instruction
15/19
3
Prompt need to save the target file name and path.
-
7/30/2019 K15K15 Signaling Analyzer Instruction
16/19
4OK
MultiLink
test
This interface is a reminder that what is the format of the contents of the file need to save, you can choose according to the following chart,
press OK to save the signaling to the specified file, the file can be copied from a network share. In the MultiLink, we set up a user name and
password which are test users for copying data and remote terminal.
-
7/30/2019 K15K15 Signaling Analyzer Instruction
17/19
z z Clear signaling
1Capture RAM Ring Mode
Clear RAM Buffer
too much signaling, when need to clear signaling, in the Capture RAM Ring Mode of the data flow diagram, click the right button in the
pop-up menu, select Clear RAM Buffer, then can clear the buffer data.
2YES
Prompt it will lose all data, click YES, the world was quiet.
-
7/30/2019 K15K15 Signaling Analyzer Instruction
18/19
3
After a quiet world.
-
7/30/2019 K15K15 Signaling Analyzer Instruction
19/19
z z signaling method of real-time display
1 Live
LiveFreeze
Do you see that the live button? P ress down, do not be afraid. When, after signaling, mouse over to view specific content signaling, Live button
automatically pops up, Freeze mode is automatically activated.