JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI> Distribution of this document is unlimited. PROPULSION WIND TUNNEL FACILITY ARNOLD ENGINEERING DEVELOPMENT CENTER AIR FORCE SYSTEMS COMMAND ARNOLD AIR FORCE STATION, TENNESSEE

Upload: others

Post on 19-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

JU

AEDC-TR-66-80 X

N0V1 1967

g3335g£gSS

CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL

J. A. Gunn

ARO, Inc.

May 1966

/yp 4Q(60Q)12QI>

Distribution of this document is unlimited.

PROPULSION WIND TUNNEL FACILITY

ARNOLD ENGINEERING DEVELOPMENT CENTER

AIR FORCE SYSTEMS COMMAND

ARNOLD AIR FORCE STATION, TENNESSEE

Page 2: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

p* •,.

^>

M7« When [.I. S. Government drawing specifications, or other daia are u?.ed for any purpose olher than a definitely related Government procurement operation, the Government thereby incurs no responsibility nor any obligation whatsoever*, and :he r.ict thfll the Government nay have formulated, furnished, or in any wuy supplied til« sm<i drawings, spei'ihcuions, or üthei data, is not to be regarded by implication or otherwise, or in any manner licensing Ihe holder or any other person or corporation, or conveying any riyhts or permission to manufacture*, use, 01 sell any patented invention that may in anyway be related thereto.

Qualified users may obtain copies of this report from ihe Defense Documentation Center.

References In named commercial products in this report are not to be considered in any Sense as an endorsement of the product by ihe UnitedRlalt-s Air Force or ihe Govi-rninunl.

Page 3: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-aO

CHECK CALIBRATION OF THE AEDC 16-FT

TRANSONIC TUNNEL

J. A. Gunn

ARO, Inc.

Distribution of this document is unlimited.

Page 4: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

FOREWORD

The work reported herein was sponsored by the Arnold Engineering Development Center (AEDC), Air Force Systems Command (AFSC), under Program Element 65402234.

The results of this calibration were obtained by ARO, Inc. (a sub- sidiary of Sverdrup & Parcel and Associates, Inc.), contract operator of AEDC, AFSC, Arnold Air Force Station, Tennessee, under Con- tract AF40(600)-1200. The calibration was conducted from May 5 to 14, 1965, under ARO Project No. PB9340, and the results of this calibra- tion program were incorporated into the data reduction program for subsequent tests. The organization of this final report was accom- plished under ARO Project No. PB3642. The manuscript was sub- mitted for publication on March 23, 1966.

This technical report has been reviewed and is approved.

Francis M. Williams Jean A. Jack Major, USAF Colonel, USAF AF Representative, PWT DCS/Test DCS/Test

li

Page 5: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

ABSTRACT

Tests were conducted in the Propulsion Wind Tunnel, Transonic (16T) of the Propulsion Wind Tunnel Facility (PWT) to determine the test section Mach number calibration and Mach number distributions. During the test. Mach number was varied from 0. 50 to 1.60, and the wall angle from -1. 00 to +1. 00 deg, while holding tunnel total pressure at 1000 psfa and tunnel temperature at 120°F. At all Mach numbers the region from Station 1 to Station 20 was considered the test region. The results show that the tunnel calibration is a function of test section wall angle, and that all wall angles in the calibrated Mach number range produce Mach number distributions acceptable for testing. This was the first calibra- tion after the installation of the modified main compressor utilizing fiber glass rotor blades.

in

Page 6: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

CONTENTS

Page

ABSTRACT iii NOMENCLATURE vii

I. INTRODUCTION 1 II. APPARATUS

2. 1 Basic Tunnel and Support Equipment 1 2. 2 Calibration Equipment 2

III. PROCEDURE 3. 1 Calibration Procedure 3 3. 2 Data Reduction Procedure 3

IV. RESULTS AND DISCUSSION 4 V. CONCLUSIONS 6

REFERENCES 6 APPENDIXES:

I. Linearized Calibration Equations 41 II. Supplemental Calibration Information 46

III. Standard Deviation 47

ILLUSTRATIONS

Figure

1. Propulsion Wind Tunnel Facility 9

2. 16-ft Transonic Tunnel Test Section 10

3. Typical Hole Pattern in the 6-Percent-Open Inclined-Hole Walls 11

4. Photograph of Empty Test Section Showing Solid Plates 12

5. Variation of Optimum Test Section Wall Angle, 0W*. with Mach Number (From Ref. 2) 13

6. Variation of Optimum Test Leg Pressure Ratio, Xx** with Mach Number (From Ref. 2 - Corrected by Fig. II-l) ' 14

7. Tunnel Calibration Based on Solid Plate Orifices .... 15

8. Tunnel Calibration Based on Perforated Plate Orifices ♦ 16

Page 7: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

Figure Page

9. Effect of Wall Angle on the Test Section Calibration - Data Obtained from Tunnel IT Using Long Static Probe (From Ref. 4) 17

10. Effect of Wall Angle on the Test Section Calibration - Tunnel 16T Data from Solid Plates Compared with Earlier Short Static Probe Data 18

11. Effect of Wall Angle on the Test Section Calibration - Tunnel 16T Data from Orifices on Perforated Walls ... 19

12. Mach Number Distribution on Solid Plates at Various Wall Angles

a. Ma = 0.80 to 1. 20 at 0W = -1.00 deg 20 b. M,,, = 0.80 to 1.20 at 0W = -0.75 deg 21 c. M« = 0.50 to 1.00 at 0W = -0.50 deg 22 d. M«, = 1.05 to 1.50 at 0W = -0.50 deg 23 e. M, = 0. 70 to 1. 00 at 0W = -0. 25 deg 24 f. M„ = 1.05 to 1.60 at 0W = -0.25 deg 25 g. M. c 0.50 to 1. 00 at 0W B 0 deg 26 h. M^ = 1.05 to 1.60 at 0W = 0 deg 27 i. M,,, = 0.90 to 1.60 at 0W =+0.25 deg 28 j . M^ = 0.50 to 1.00 at 0W =+0.50 deg 29 k. M„ = 1.00 to 1.60 at 0W = +0.50 deg 30 1. M,, = 1. 30 to 1. 60 at 0W = +0. 75 deg 31

m. M„ = 0.50 to 1.00 at 0W = +1.00 deg 32 n. M» = 1.05 to 1.60 at 0W =+1.00 deg 33

13. Statistical Evaluation of Empty Test Section Mach Number Deviations at Various Nominal Mach Numbers

a. WL^O.60, 0.80, 1.00, and 1. 20 34 b. M, - 1.40 and 1.60 35

14. Local Mach Number Variation at 0W = 0 deg, 0W = 0. 25 deg, and 0W = 0w* Based on 95-Percent Confidence Level

a. 0W = 0 deg 36 b. 0W = 0. 25 deg 37 c. 0W = 0W* ' 38

15. Lower Wall Mach Number Distribution Through Contraction, Nozzle, and Test Section for Various Test Section Mach Numbers at 0W = 0 deg 39

VI

Page 8: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

NOMENCLATURE

Defined in Appendix I

b

be

k

Mc Mach number as computed from pc/Pt

Mc <m. h) ] Defined in Appendix 1

MTP Mach number as computed from the average of Mach num- ber measurements along the perforated plate from station 1 to 20

M-j-s Mach number as computed from the average of Mach num- ber measurements along the solid plate from station 1 to 20

M, Free-stream Mach number

M-U, m) ) > Defined in Appendix I

M«(m,h)j p Plenum chamber static pressure, psf

p. Compressor inlet static pressure, psf

p_ Static pressure measured on perforated plate, psf

Pg Static pressure measured on solid plate, psf

pt Stilling chamber total pressure, psf

p Free-stream static pressure, psf

ew Test cart wall angle, deg (positive when walls are diverged)

0W* Optimum wall angle, deg

At* Optimum tunnel pressure ratio, pt/Pi

SUBSCRIPTS

h High transonic Mach number range

i Low transonic Mach number range m Mid transonic Mach number range

x Axial station number, ft

vii

Page 9: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

SECTION I INTRODUCTION

The Propulsion Wind Tunnel, Transonic (16T) began shakedown and operation in July of 1956. In August 1961 Tunnel 16T was removed from service by a main compressor failure. The compressor rotor has been redesigned and installed with fiber glass reinforced plastic blades. The results of the test section calibration with the plastic bladed compressor are presented in this report. This calibration was initiated to determine empty test section Mach number distribution and Mach number calibration over a wide range of test section wall angles.

SECTION It APPARATUS

2.1 BASIC TUNNEL AND SUPPORT EQUIPMENT

Tunnel 16T is a continuous flow, closed-circuit tunnel capable of operation at Mach numbers from 0.50 to 1.60 and stagnation pressures from approximately 100 to 4000 psf. The location of Tunnel 16T and its relationship to the rest of the PWT facility are shown in Fig. 1. The compressor drive system consists of four electric motors with a maxi- mum power rating of 216, 000 hp. The main compressor is a constant speed, three-stage, axial flow compressor with variable stator blades for inlet volume flow control. The calibration of the compressor with fiber glass blades is given in Ref. 1. Temperature control is provided by an air-to-water heat exchanger located just upstream of the stagna- tion region. The stagnation temperature control is automatic and will maintain the average temperature to ±1°F of the set temperature through the normal temperature range from 90 to 125°F with estimated devia- tions across the stagnation region of no more than ±5°F.

Supersonic Mach numbers are generated by a flexible, two- dimensional Laval nozzle. Fifty contours are available for supersonic Mach numbers from 1.00 to 1.65. A 10-ft variable porosity flow stabilization region, shown in Fig, 2, connects the solid plate nozzle and the porous test section. The removable test section is 40 ft long and 16 ft square with 6-percent porosity walls. Figure 3 is a sketch of a portion of the wall showing the hole pattern and cross-section details. The test section sidewalls can be converged to 2 deg and diverged to 1 deg. A scavenging scoop is located in the diffuser to remove the

Page 10: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR'66-80

products of combustion during propulsion tests. A closed tip is in- stalled on the scoop during aerodynamic tests.

Plenum suction is required for removal of air through the test section walls to prevent choking in the transonic range. For initial operation plenum suction was provided by opening the diffuser flaps. As its units became operational, auxiliary suction was provided by the Plenum Evacuation System (PES). The PES consists of two increments of compressors which can operate independently. All or a portion of the air removed from the plenum may be energized by the PES and returned to the tunnel in the diffuser. Pressure level control and dry- ing are maintained by removing air from the tunnel (either from the plenum or from ports in the scavenging scoop support strut) and exhausting it to the atmosphere. Dry make-up air is returned to the tunnel downstream of the scavenging scoop from the PWT dryer build- ing which uses silica gel as a desiccant. The Rocket Test Facility (RTF) exhauster plant may be used to supplement the PES in removing air for drying and pressure control.

2.2 CALIBRATION EQUIPMENT

The test section Mach number distributions were obtained from static pressure orifices 0. 090 in. in diameter. These orifices were installed on 1-ft centers in the test section floor on lines 1 ft either side of the tunnel centerline. The orifices on the east side of the centerline were set in a 2-ft-wide solid plate extending from station 0 to station 30, whereas the orifices on the west side of the centerline were positioned in the perforated test section liner plates with an orientation to the perforations as exhibited in Fig. 3. The location of the solid plates in the empty test section is shown in Fig. 4.

In addition to the orifices in the test section, other orifices in the tunnel floor, placed nominally on the centerline, extend from station -80 to station 39. These orifices were used to determine flow development and decay. Most orifices were connected to both transducers and unity oil manometers.

Page 11: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

SECTION III PROCEDURE

3.1 CALIBRATION PROCEDURE

Variables during this empty test section calibration were Mach number and wall angle. The general procedure followed was to set a chosen wall angle and vary Mach number through the desired range. Nominal Mach number was set by adjusting plenum pressure using tables from previous calibration data, and tunnel pressure ratio was regulated to give the best test section Mach number distribution. This was determined visually from a 100-in. manometer board in the control room. For Mach numbers up to and including 1. 05, the nozzle was .set on the sonic contour. Above Mach number 1.05 supersonic contours were used.

Throughout this calibration a stagnation pressure of 1000 psf was maintained. Most of the test was conducted at a stagnation tempera- ture of 120°F; however, some data were obtained at a stagnation tem- perature of 100DF. Check points showed that there was no noticeable difference in data at 120 and 100°F. A tunnel humidity level of 0. 001 lb of water per pound of mixture or less was maintained for Mach num- bers greater than 1. 2.

3.2 DATA REDUCTION PROCEDURE

The on-line printout consisted of basic tunnel conditions {stagnation temperature, stagnation pressure, and plenum pressure) and calibration data. Several on-line plots were used to observe data which were not tabulated on-line, and an off-line printout supplied the ratio, p/p^, for all orifices.

Since most model testing is done in the test section region from station 1 to station 20, the calibration data were based on that length. The on-line program printed out the average Mach number on the solid plates, MTS.

and the average Mach number on the perforated walls, MTP. for stations 1 to 20.

i

The following relations were computed to determine tunnel calibra- tion:

JW77] Mc =. 5 -^ (1)

Page 12: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

". -^fe)"5-1] (2> . 4[(^r+-1] (3>

MTPX =

MTS ^ (4) I10 M

TS, •j 20

T = MTPX

l M" = -^— <5)

The procedure used to reduce the results of this calibration to a form which is employed for on-line data reduction is given in Appendix I.

SECTION IV RESULTS AND DISCUSSION

Previous calibrations (Ref, 2} have established parameters for optimum shock cancellation and minimum base pressure interference for certain bodies of revolution. These parameters are 0W* for optimum cart wall angle (Fig. 5) and X* for optimum tunnel pressure ratio (Fig. 6, which was corrected according to Appendix II). However, facility limitations, different test requirements, and a variety of model sizes and shapes frequently dictate that the tunnel should be operated at test section wall angles other than 9W*. The main objective of this test, therefore, was to obtain empty test section Mach number distributions and calibrations for a range of wall angles from +1. 00 to -1. 00 deg. This "complete" calibration will allow tests to be conducted within this wall angle range with a high degree of certainty in the Mach number settings.

Other previous calibrations (Ref. 3) have shown that the ratio of plenum chamber pressure, pc, to stagnation pressure, p^, can be used as a reference to set test section Mach number. The calibration of M^S and MxP for various wall angles is presented in Figs. 7 and 8. In these figures the calibration reference, pc/pti is given in the form Mc. Com- parison of these plots raised the question of which Mach number, MTS or M.pp represented the free-stream Mach number, M,,,. The PWT 1-ft Transonic Tunnel (IT) calibration data obtained from a long

Page 13: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

centerline probe and given in the plenum coefficient form, (p^ - Pc)/pt, is shown in Fig. 9 (Ref. 4). A comparison of the Tunnel IT data with the Tunnel 16T data (Figs. 10 and 11) indicates that results obtained from the solid plates in Tunnel 16T exhibit the same general trend as the data from the long centerline probe. Tunnel 16T calibration data (Ref. 3) from a short static pipe are compared with the solid plate data in Fig. 10. The agreement of the data is excellent and points out con- clusively that the calibration data obtained from orifices in solid plates on the tunnel floor represent the free-stream Mach number.

The Mach number distributions measured on the solid plates from station 1 to station 20, free-stream Mach number, Mw, and the refer- ence Mach number, Mc, are presented in Fig. 12. It will be shown in the following discussion that in general the best empty test section dis- tributions are obtained at 0W = 0. 25 deg.

Although the data in Fig. 12 can be used to determine model posi- tioning, it is difficult to resolve from these data which wall angle gives the best overall distribution at a given Mach number. A more complete analysis of the distribution was obtained by using the standard deviation method (explained in Appendix III) based on a 95-percent, 2a confidence level. The data acquired from this statistical approach should be used primarily to compare one set of data with another, but it is probably indicative of absolute values of deviation.

Figure 13, which is a plot of the 2a Mach number deviation versus 0W for constant nominal Mach numbers, indicates that in almost all cases the lowest Mach number deviation occurs at 0W = 0. 25 deg. This result is most pronounced in the supersonic range where very distinct minimum points or "buckets" appear. This phenomenon may be ex- plained by the physical fact that the angle made by a nozzle side wall and the tunnel centerline at the nozzle exit (station -10) ranges from 0. 22 to 0. 32 deg in the Mach number range above 1. 10. If the nozzle exit angle does not match the test section wall angle then flow dis- turbances, which extend through the test region, will be generated at the nozzle-test section intersection point. The 2a deviation throughout the Mach number range for 0W = 0 deg, 0W = 0. 25 deg, and 0W = 0W* is given in Fig. 14.

For all Mach number and wall angle combinations tested, the region between stations 1 and 20 is suitable for model testing. How- ever, Fig. 12 shows that flow disturbances are prevalent for negative wall angles in the supersonic range especially in the front of the test cart. Proper model positioning can minimize this problem. It is shown in Figs. 13 and 14 that the (*) conditions mentioned previously are not

Page 14: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

necessarily synonymous with the best empty test section Mach number distribution. As explained in Ref„ 2, 0W* and A * represent optimum conditions for minimizing test section wall interference with models of a particular type and size.

Development of flow in Tunnel 16T is illustrated in Fig. 15. The flow characteristics of this plot are: a gradual acceleration of flow in the contraction region, a smooth development of flow in the nozzle, and a flat distribution in the test section. The distribution in the bulge region may have little meaning since the calculations assumed isen- tropic flow.

SECTION V CONCLUSIONS

The following conclusions were reached as a result of the calibra- tion of Tunnel 16T:

1. The Mach number obtained from the average of 20 Mach num- ber measurements along the solid plate represents the free- stream Mach number, and agrees well with the calibration from a short static pipe.

2. AU Mach number and wall angle combinations tested were found to be suitable for model testing, but, in general, the best empty tunnel Mach number distributions were obtained at 0W = 0.25.

REFERENCES

1. Parli, C. L. "Aerodynamic Calibration of the AEDC 16-FT Transonic Tunnel Compressor with Fiberglass Rotor Blades.' AEDC-TR-65-242 (AD474436), November 1965.

2. Nichols, J. H. "Determination of Optimum Operating Parameters for the PWT 16-Ft Transonic Circuit Utilizing One-Percent Bodies of Revolution." AEDC-TN-59-100 (AD225362), September 1959.

Page 15: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

3. Chevalier, H. L. "Calibration of the PWT 16-FT Transonic Circuit with a Modified Model Support System and Test Section. " AEDC-TN-60-164 (AD241785), August 1960.

4. Chew, William L., Jr. ''Determination of Operating Parameters for the 1-Foot Transonic Tunnel Utilizing Cone-Cylinder Bodies of Revolution. M AEDC-TN-60-69 {AD235384), April 1960.

Page 16: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

RTF SCAVENGING HEADER

TRANSONIC TUNNEL COMPRESSOR

SUPERSONIC TUNNEL COMPRESSOR

COMPRESSOR EQUIPMENT BUILDING >

m O n

Fig. 1 Propulsion Wind Tunnel Facility

Page 17: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

SOLID AREA

-PERFORATED WALLS

SOLID DIVERGED WALL SECTION TO ALLEVIATE STRUT BLOCKAGE

(BULGE SECTION)

MODEL SUPPORT STRUT

> m o o

2-FT WIDE SOLID PLATE IN FLOOR REPLACING PERFORATED LINER FROM STA. 0 TO STA. 27

TEST CART

STATION NUMBERS IN FEET

Fig. 2 16-ft Transonic Tunnel Test Section

Page 18: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

ALL DIMENSIONS

IN INCHES

FORMICA ALUMINUM

^mm S&75 0.375

0.750

SECTION THROUGH TYPICAL HOLE

Fig. 3 Typical Hole Pattern in the 6-Percent-Open Inclined-Hole Walls

11

Page 19: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

ro

y

/

d Plate

A E D C 59015-65

> m o n

ON

Fig. 4 Photograph of Empty Test Section Showing Solid Plates

Page 20: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

0

1.0

0.8

0.6

0.4

0.2

* oc>

-0.2

-0.4

-0.6

-0.8

-1.0

r/ '■'

0.6 0.7 0.8 0.9 1.0 I.I 1.2 13 1.4 1.5 1.6

MACH NUMBER

Fig. 5 Variation of Optimum Test Section Wall Angle, 0W , with Mach Number (From Ref. 2)

OJ

o

s

Page 21: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

1.6

1.5

1.4

1.3

1.2

II

1.0

-- • -

- - — - c ̂

^>

V. I f l.ulJi

•**••' """ T

■""• ^

—c M r— i )

> m o r>

0.6 0.7 0.8 0.9 1.0 - I.I 1.2 1.3 1.4 15 1.6

MACH NUMBER, Mn

Fig. 6 Variation of Optimum Test Leg Pressure Ratio, AT*, with Mach Number (From Rut. 2 -Corrected by Fig. Il-I)

/

■!

Page 22: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

.032

.028

.024

.020

.016

.012

.008

no4.

SYM. 1.00 .75 .50 .25 0

-.25 -.50 -.75 1.00

1 eg • ^ ! afofcfy

A a D

o O

a • A • Q •

0 -

>

? A A Ö

A J J o B

A n

LR J / , , f *'

M® H V "

.. d a 1 AM 1 ■ ■ '» MTS 1 i

1 Äs< ► ! • I

■fll 3

3—j •

i *•: **"£) i 4 * 1 i s &

1 2

1 i ' 3 1 k

! P & r^ !

o

< > * A

0

-.004

-.008

-.012

PA C

8

hi -^ ' A A

$ 1

a

Vs

t X <

$ $ 8

o

8

A V

8 04 0.6 0.8 1.0 1.4 1.6

M. "TS tl

Fig. 7 Tunnel Calibration Based on Solid Plate Orifices

1.8

15

Page 23: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

«r-RM<

£> \0 <b

.032 SYM R deqj A I.O0 Q .75 D .60 O .26 O 0 a -.25 A -.50 o -.75 0 -1.00

1 .028 /!

□ D

I 1

I .024 t

H / i ? 1 a

.020 > 4? ( 3 ?

rf< s-o-S

I

i a t > < *

.016 4i ao<

1 1 *m. r

J L_usls_ .012

4 ! I 3 (

3 MFI"

t 8 ! !"

p * k

.008

I * 1 . * LA' >*' S v

1 8 ?

.004 e<

1 I < 6

n 1 >*

0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8

M TP

Fig. 6 Tunnel Calibration Based en Perforated Plate Orifice»

16

Page 24: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

0.008

0.004

a?

Ü

ÜJ s HI -J a

-0.004

-0.008

-0.012

%> .-.75"

y-.50"

^-.25" >

y 0"

►.50°

0.4 0.6 0.8 1.0

MACH NUMBER, M

1.2 1.4 1.6

oo

Fig. 9 Effect of Wall Angle on the Test Section Calibration - Data Obtained from Tunnel IT Using Long Static Probe (From Ref. 4)

> m O n * -i 1

s s

Page 25: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

O)

0.008

111 O u.

8

§ z 111

0.004

-0.004

-0.008

-0.012 0.4 0.6 0.8 1.0 1.2

MACH NUMBER, MM ' 00

1.4 1.6

Fig. 10 Effect of Wall Angle en the Test Section Calibration - Tunnel 16T Data from Solid Plates Compared with Earlier Short Static Probe Data

1.8

> m

n

Page 26: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

0.008

i*

UJ o t Id O o s 13 z u

0.004

-0.004

- 0.008

-0.012

*w / .i.oo°Y

^^x ' vs.

^ WVJM i^r. ^v

__. ^ .

-2i 5° t i/^S^n i \j>*~fir—"^

1 |—,

H^Tt 0.4 0.6 0.8 1.0 1.2

MACH NUMBER, MM 00

1.4 1.6 1.8

CO Fig. 11 Effect of Wall Anale on the Test Section Calibration - Tunnel 16T Data from Orifices on Perforated Walls

n H 70 ■

Page 27: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDCTR-66-80

1.2

I.I

e 1.0 tu CD

a 0.9

< 8

Q8

0.7

■2^T

-A-<>-

^A-0

o0O?oo oOoo6oo°°o o °600oooOo6o6oo0io6

0A °ooö0yoöo <j>oooöo 6oY" —ö-QO-O-O o i o o o o Op^07Q°-

QrQ-O-Q Q o 0 CrQ-OrQ- ?A j T°T ? I i i -1 i i n°n

^0näO-O-0X3n0rO-O-O-O-O-O-O"O O O O

Q-o-o-öroo^^-o-o-ao-ooro-o"oö o 6 ooo -o"o"°"0-o-o-crO-o- o-o-o-o-cronoro*

-Q-o-o-o-o-o-o-o-aooo-o-o-o-o-o-o-o-o-

0 2 4 6 6 10 12 14 16 18 20

TUNNEL STATION, FEET

a. MM - 0.80 to 1.20 at 0W = -l.OOdeg

Fig. 12 Mach Number Distribution on Solid Plates at Various Wall Angles

20

Page 28: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR.66-B0

I B~

*0

a: HI m

I.I "*V -A-/

o 1.0 1 _>

J a9

-A-0"

0.8 A

OJ

j OTT °"Oöo~o °"? ooooooo Y I I I ° i 1 f I o

'^"^öoöO'^owo^oö o 7^"°"0-o-^o-o-o^o-o-<^o^o-A-o-o

I I T I I I I j I —^o-o-o-o-o-o-^yp^o-o-o-o-acr0"0"^ 7 o (TO-o-oö-ö"crao-o-o-o-Q-o-ö-o-o-o"0

ö-cro-0"0-ö-o~o-o-c>o-o-o- ö-o-o-a-cro

-Q-o-o-o-o-o-aao-äo- X>P-0-00-0-0-0-n-o- -O-O-O-GTÖ- III

0—O"Ö"0"0"0~0"0*°J0"0'0"0"0 II i I I ~ I I I I I n-0-0-0-CK5-aO^O-00-0-Q-0-0-0-0-0-0

6 8 10 12 14 16 18 20

b. M.

TUNNEL STATION, FEET

0.80 to 1.20 ot 0W - - 0.75 d«g

Fig. 12 Continued

21

Page 29: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-B0

1.0

Q9

tr. ÜJ CO

<

o

Q8

0.7

8 u -2-S-

-A0-

-A-0-

-A-0-

-A-0-

-A-0-

—0-0-6- o-o-0-o-o-6-o-oo- o-o-o-o-o-o-o

Q-o-o-o-o-o-o-o-o-o-o-o-o-O-ao-ooo-o

I I I I I I I I I T ^y-O-O-O-O-Cp-O-O-O-O-O-O-O-O-O-O-O-O-O-o

O-O-O-O-O-O-o-O-O-Ö-O-9-O-O-O-O-O-O-O-O

I I 0^-0^-0_0_0-aO-0_0_QjD_0_0_0_Q_0_Q_Q

0.6 oOQöQOooopoOooonOQOp

0.5

0.4

.0 O QQOQOQQQOOOQOOOQOO *

c. M.

6 6 10 12 14 16 18 20

TUNNEL STATION, FEET

0.50 to 1.00 ot 0W - - 0.50 dog

Fig. 12 Continued

22

Page 30: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

1.6

1.5

tu m

1.4

| ,.3

Ü o

I.I

1.0

*•*"

Ao o< V )0°0ouoOu°ÜUooouo

)QC roc AO oooc >oc ) c >o< Jwooc poo

Ao c ,oc )Ol >01 >oc >0( ?oooooouo

A

c 5o-c

yo-c

)-CK

>-o-c ^O00ouyo000wo0o

A

c oc

h rcr<

7 u y v-> o u ^^ u vJ O

A-0

c

—c >-o^

5 O *■

>-o-c r XO-C >o-c )—

0 2 4 S 6 10 12 14 16 18 20

TUNNEL STATION, FEET

d. MB » 1.05 to 1.50 at flw - - 0.50 dog

Fig. 12 Continued

23

Page 31: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

1.0

CE

-A-

-A_>

< 0.8

8

0.7

0.6

-8 o SS S

-A-,

Q-OO-O-O-O-O-O'O-O-O-O-O-O-O'C^O-O-O-O

O-O-OLO-OO-O-O-O-Q-O-P-Q-O-O-OO-O-OLO

o-o-o-o-o-o-o-o-o-o-0-0-°-o-o-o-0-o-0-o

^ o-O.QjO-OLao ^QjQJ^Q.CLCLa.0 o o o o

0 2 4 6 8 10 12 14 16 18 20

TUNNEL STATION, FEET

e. MM - 0.70 to 1.00 at 0W « - 0.25 deg

Fig. 12 Continued

24

Page 32: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR.66-80

L6

1.5

CD -A-

x o

< o o

1.3

J 1.2 -A-

l.l

1.0

-A-

°~öx>oij^cru^'0-ö-o-^-oro-oiTO-o

^O-Cp-öo^'Ö—QX)'o"O-Oi0"o"O"Ö'O-o-0-O

öoö?-^?^?'0-oo-o-ao-o-0^-o-0o

^O-jjO^^O^^iyO-^-^-O-C^y-^O

_A_.

l^.^jo.o-oJ^oo-O-o-OLOo-i-ü^-Oo °l T i I T I |T

o-CLCLao-o-ö^-Q-o-O-Q-o-Q-o-O-Q-ao -Q-O'Ch I

^-O-^?^"0^0^"^"0"?"^^0^"0"?"

0 2 4 6 8 10 12 14 16 18 20

TUNNEL STATION» FEET

f. M^, -= 1.05 to 1.60 ot 0w - -0.25deg

Fig. 12 Continued

25

Page 33: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

1.0 -A-

-A-

Q9

0.8

-A-

-A.

-A-, ÜJ 03

S 0.7

o-o-O-ö-o-o-o-o-o-o-o-o-o-o-ao-o-o-o-o

o-o-o-o-oo-o-o-o-oo-o-o-o-o-ö-o-o-o-o T -Op-°-0-0-0-o-0-0-0-0-0-0-o-0-0-0-o-0"rr

T I _ ] I I I I _ II I _ i .O-O-O-O-Q-O_O-a-O-O-O-CLO-O^0LO-O-Ö-O-O

■o-O-o-ao-o-o-o-G-o-o-o-o-o-o-o-o-o-ao

_A.^—O-OJO-O-O-O-O-O-OO-O-O-O-O-O-Q-O-O-O-O

<

0*6 -A_, 0-O_Q,O-0_p_O-O-O-Q_O_O_O-0.O-0-O_O-0 0.

05 -A-/ Q O-O-O-O-O-O-O-OO-OO-O-O-Q-O-O-O-O-O-O

Q4 8 12 14 16 18 20

TUNNEL STATION, FEET

g, MM - 0.50 to 1.00 at 0W = 0 deg

Fig. 12 Continued

26

Page 34: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDCTR-66-80

1.6 l-A- 5^00-0^0-0-^0-0-0-0-0^-0-0-0-0

1.5 ^ö-?"0^^?^?"0"?""0^0"?^?-

1.4

s hA-ri-ovor<jr^

g 1.3 <

u* oi!rO-?-o-?Tj-?-o-9-o-9-o-?Ä?-a90-?

< u o

1.2 hA-

HA-

ÖT) o"o"0^-6-o-Ono-6o9oo-o-o-o-o-o-ö—

i-i h-A-

l-A-

^-oö-°-?-ö"cro-ö-o-ö-o-äo-ö-o-ö-o-0

0-^oo-i-o-o-o-cxo?-o-o-o-o-o-o-o-0 o-o-o-o-O-o-o-o-o-o-9-o- 9-0-9-0-0-0-9

o -a?

1.0 0 2 4 6 S 10 12 14 16 18 20

TUNNEL STATION, FEET

h. MM - 1.05 to 1.60 at Sw = 0 d«g

Fig. 12 Continued

27

Page 35: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

T~="

1.6 -A- o-Q-^-o-o-o-ö-o-o-öO-oo-o-o-o-o-o-o-o

1.5 _A- Qi0_0-0-0_0_Ocr0.0.0_0.0_o_0_o^0.

1.4 HA- _a o-o-o-o-o-o"cro-o-ö"°cro-o-o"*ao-o-o

13 O-Gr0-a0-0-a-Ö-0-0-0-o-0-9-a°0-0-0-O

i -A-

-A- u Q

I.I -A-

o OQOOG O-Q-Q-O-O-O-O-O-O"0-ö-O Y

öorr9-°-9ö^"OTrO"9"°'9" 0-9-0-0-0-0

_A-

I 1 I I I I I II ^ip^-o-o-o-o-o-c^A-o^-o-o-o-o-o-o-o-o

o-6-o-o-o-o-o-ö-o-o-o-9"0"9"°"0-o-9-o-o

1.0 -0-0-0-0-0-0-0-0-0-0

Q9 -A-

-O-O-O-O-C

-0-0-0-0-0-0-0-9-0-0

J-OnCrCp-O-O-O-cp^-^O-Q-O-o-O-o-O-ö-O-Ö

-O-O-O-OO-OO-Q-O-O-O-O-O-O-O-O-O-O-O-O

as 0 2 4 6 8 10 12 14 16 18 20

TUNNEL STATION, FEET

i. M^ - 0.90 to 1,60 at 0W - + 0.25 d«g

Fig. 12 Continued

28

Page 36: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-6Ö-80

1.0

0.9

<E 08 UJ m

I I T i i I i T I I 1 I I T I T i ill

I-A^-L O-0-O-O-O-O-o-O-OO-O ^O-O-O-O-O-O-O-O-O

-o-o-o-o-o-o-o-o-o-o-o-^o-O'O-o-o-o^o-o-

"A A I o-O-O-p-O-O-o-O-O-O-O-O-O-O-O-Q-O-O-O-o-

I

u a7 <

ae

-A_, O-O-O-O-O-O-O-O-O-O-O-O-O-O-O-O-O.O-O-O

-A_, o-O-o-p-o-O-o-o-o-o-oo-o-o-o-o-O-o-ao

0.5 _A. 0-Q-CHO-0-aoX)-0-0-0-0-0-0-0-OJO-OJO-0

0.4

0 2 4 6 6 10 12 14 16 18 20

TUNNEL STATION, FEET

j. MN » 0.50 to 1.00 at 0W - + 0.50 deg

Fig. 12 Continued

29

Page 37: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

1.6

1.5

1.4

ü 1.3

o 1.2

1.1 -i

_A -0-o-öxro-o—o-°|ao-o-oö

_o_ —^-O. cycrcrö—o

o-°-ö

oooooooOo°°

OO-O-o-O-O^jnO-Q-g-O QOOo ° 9"°'°

^A-

-A-

O-O-O-O-OQ-O cro-sro-o-o-0-o-0-9 -o-o

°r> o JL o o o crO"0-o"°"0-oo-o"0-oO"ö T i l '

° 6o 9"0"°"0"00"Q ° °"0 o~0"ü"Or9'OQ T -^j)-o-o-oo-o-o ö ^ 6 y 0-0-0^-0-0-00 -o-9'0?o-?-o-Q-o-o-o-o-o-o-o-o-o-o-o-o

0 2 4 6 8 10 12 14 16 18 20

TUNNEL STATION» FEET

lc. MM - 1.00 to 1.60 ot öw = + 0.50 deg

Flg. 12 Continued

30

Page 38: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

1.6 o O-O-O-O-OQ-O—o ao-o-o Q o o o cro

tu CD

Ü <

5 o

O 1.5 -A- O „n-Q

O

o-o-o-o^o^+^+^öoö^°o

1.4 _O_CL O-Q-O-OOOO O °OÖOoO"Ö"°"°

1.3 -A- Q-O-O-O-OQO 0 O 0 O-O-Q-O-O-O-O-O-O

1.2 I 0 2 4 6 8 10 12 14 16 18 20

TUNNEL STATION, FEET

I. MM - 1.30 to 1.60 at 0W - + 0.75dsg

Fig. 12 Continued

31

Page 39: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR.66-80

1.0

a9 -A

a: m

2

Q8 -A

-A-

i i i T ' ' o-o-o-o-o-o-oo^-o-o-aaoö-oö-o-o

oo-o-o-<>o~o-o-o-oo-o-o-o-o-o-o-o-o

O-O- Q-0-0-0-0-0-00-0-OÖ-0-0-0-0-0 i T i i i I T I i i

o-o-o-o-o-o-o-o-o-o-o- o-o-o- ao-o-o-Q

0.7 -A O-O-O-O-O-O-O-O-O-O-O-O-OO-O-O-O-O-O

0.6 -A., 0-O_0-0X)-O-ao-O-OJ0-O-O-0-0-O-Q-O-0

05 _A. O-O-Q-O-O-O-OLO-O-O-OLO-O-O-O-OJO-O-O

a4 6 8 10 12 14 16 18 20

TUNNEL STATION, FEET

m. MH - 0.50 to 1.00 at 6W - + 1.00 dog

Fig. 12 Continued

32

Page 40: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

o

o 1.6 a .-O-rv

o 1.5

ao-o-o-öTD-^-ooTJ-o d) o o o A 0-+

OOOOQ-O-°-

EC UJ CD z

1.4 o_a,

OOOOOOQOOOO

o-o-ao r> o c!) o ° o ö o o °"9" .-O-O-

y 1.3 -A- Q-ao-o-0 0O0(!)QOOO o-o-o-o-o-o

1.2

-A-

00 ö o o o o o 6 o-o-o-o-o-6-o-yo-^ o o o OTTö^'O-O-O-O-O-O-D'O-OTTO-O

l.i -A- cr Q-°o-o-o-jro o o o a oo-i-o 1 ^ i I i I I I I I 0-ao-cro-o-o-o-o-o-o-oii-0-90-o-o-i- i.o

0 2 4 6 8 10 12 14 16 18 20

TUNNEL STATION, FEET

n. M^, ■= 1.05 to 1.60 at 0W = + 1.00deg

Fig. 12 Concluded

33

Page 41: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

0.010

0.008

2 0.006 <

g 0.004

Uj ffl 0.002

* k M 1

~1 ««, = 100

1 k » i. s ̂ ■\ r> • ^ >—i_f 1

>

^ i "0 I

<

b

0.006

0.004

0.002

0.006

N r^\ >-x \

" M =.BO

00

*

\ K —f W-- "1 f f

-1.00 •0.50 0 0.50

WALL ANGLE, ffw, (deg)

0.026

0.022

0.018

0.014

0.010

0 006 -1.00 -0.50 0 0.50

WALL ANGLE, fi,, (deg)

a. MM - 0.60, 0.80, 1.00, and 1.20

Fig. 13 Statistical Evaluation of Empty Test Section Mach Number Deviations at Various Nominal Mach Numbers

> m D O

«„=1.20

--

\ n o

?v—9<°

1.00

Page 42: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

0.024

<

g 0.020

0.016 o 1 b

0.012

o.oos

1

1 M nl.4Ö

00

0.022

0.018

0.014

O.OtO

1.00 -0.60 0 0.60

WALL ANGLE, 9 (de«)

0.006 1.00 -i.00

\G / 9 o >

«k'l-eo

b. M^, = 1.40 and 1.60

Fig. 13 Concluded

•0.60 0 0.60

WALL ANGLE, 0W, (deg>

I 00

> m O n

CJ1

Page 43: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

CO 0.020

0.016

> LU O

a: UJ m

b

0.012

0.008

0.004

'S

n \sk J..y

c\

n / 6

O O 1^0 L/9

-

i^_^^r ̂ ^^^^^^^"C

fo

0.4 0.6 0.8 1.2

MACH NUMBER, M ■ oo

1.4 1.6 1.8

g. 0W = 0 deg

Fig. 14 Local Mach Number Variation at öw = 0 deg, dw *■ 0.25 deg, and dw = 0W* Bosed on 95-percent Confidence Level

> m

n

Page 44: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

0.020

> Li O

a: m

Ü <

b CM

0.016

0.012

0.008 -

0.004

ö

rk

c p

Or

■V" ,-.-<

\_ -EXTRAPOLATED

FROM FIG. 13a

0.4 0.6 o.e 1.0 1.2 1.4 1.6 1.8 > m o n

MACH NUMBER, MM

b. 0„ «= 0.25 deg

Fig. 14 Continued

Page 45: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

CO CO

0.020

0.016

o <

" 0.012

tu ID

x 0.008 <

b

0.004

0 *- 0.4

1 1 1 1 1 1 1 1 1 1 1 1 J

o n

33 •

0.6 0.8 1.0 1.2

MACH NUMBER, M^

Fig. 14 Concluded

1.4 1.6 1.8

Page 46: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

,0

1.8

1.6

1.4

12

1.0

0.8

0.6

0.4

0.2

?

* >-O^J StwJWui

<?

~CEKT> -^ ̂ p w?

o

i-i

_^&v<$£r>. -<%ec$<xs£S2»s$**>-- A > o 0

Q: O oc o<>ov o 0^

(JJ m

—-

O jDnac^SL ixm »tf 5

3 ^ o| *L" D1

l_t£JJXDJJJJ_LMi-LJ ]

<? F T

1 n n

SE- -öj D o

Ü <

?A 0

u D _nQP9?°°3 J

4 W,

5 * Ä r cP |

>^o<wc&&- «009 >— 0

_l < f> <*f0<H VAMVWWWS

•VTVjJ O

1 g& g»<r dztf IM-

\ 1

'i%«W»l

of I* ^ 0 ^ da 4

- -

f in

§i i* i«

% *

o1 r i -80 -70 -60 -50 -40 -30 -20 -I0 0 I0

TUNNEL STATION, FEET

20 30 40

CD

Fig. 15 Lower Wall Mach Number Distribution through Contraction, Nozzle, and Test Section TOT

Various Test Section Mach Numbers at 0W = 0 deg

a n • -i x ■

Page 47: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

APPENDIX I LINEARIZED CALIBRATION EQUATIONS

A goal of this test program was to reduce the calibration to a form which could be easily stored in the computer for on-line data reduction. .This goal was achieved in the following manner:

The relation between (Mxs " Mc^ and MTS* FiS* 7' for a constant

wall angle was approximated graphically by three straight-line seg- ments. These segments formed the low, mid, and high transonic Mach number ranges. It should be noted that the parameters (M-ps " Mc) and Mxs were used instead of the more straightforward approach of MTS

and Mc to give more resolution to the data and, therefore, facilitate the graphical means of obtaining the calibration relations.

In any range the general equation of a line segment for a constant wall angle is:

(Mrs - Mc) = UITS + t> (1-1)

where k and b are the slope and intercept, respectively. Rearranging Eq. (1-1) gives

MTS-^MC* (y^) <l-2)

and defining the parameters

kö = (T^T) (1-3)

■(T^I)

results in the equation

0 = ll^k ) (1-4)

Mrs = k0Mc + hd (1-5)

From the text it was concluded that

M«, = MTS (1-6)

and therefore

MM = kö Mc + b6 (1-7)

It was assumed that kg and bg are functions of 0W, and therefore a family of line segments can be defined in each range. The graphically measured values of k and b were used to calculate kg and bg, which were reduced by a computer to a "sum-of-the-least-squares" curve fit

41

Page 48: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

for each range. The six equations formed are as follows: (Note the subscripts Ü, m, and h denote low, medium, and high Mach number ranges)

köi = (4.68349 x 1O~J)0WS + (-8.94881 x 1O_,)0W

4 + (1.04264 x 1O~')0W3

+ (-1.29942 x lO~2)0wa + (9.51048 x 10"') 0W + (1.01274) (1-8)

h6i = (-4.82642 x 10"')^* + (9.38471 x 1O~S)0W4 - (-5.37987 x IO~3)0W

3

+ (4.35438 x 10"') 0W2 + (-2.03608 x 1O"3)0W + (1.37811 x I0~s) (1-9)

kö = (-2.75364 x 10" ) 0WB * (2.80392 x 10 ) 0W + (5.77389 x 10" ) 0W

+ (-3.42326 x lO"s)0wa + (6.00905 x 10"*) 0W + (1.00268) (1-10)

bfl = (2.77071 x 1O~')0W5 M (-9.56196 x 10"") 0W" + (-2.66601 x 10"') 0W' vm

+ (-5.66745 x 1O"3)0WJ + (1.54495 x 1O~S)0„ + (1.12929 x 10"') (1-11)

k^ = (-1.19467 x 1O"3)0WS + (3.21790 x 1O~3)0W

4 + (5.42545 x 10"') 0,/

+ (-2.48307 x 1O~2)0W* + (3.78741 x 1O"2)0W + (1.00519) (1-12)

bßh = (-2.68307 x 1O~')0WS + (-3.23442 x 10"') 0W" + (5.51800 x 10_i)öw

S

+ (1.85721 x 1O"2)0WJ + (-3.62867 x 10-1) 0W + (8.25986 x 10"*) (1-13)

Values of 0W from -1. 00 to +1. 00 deg in increments of 0.10 deg were used to evaluate the intersection points of the straight line seg- ments between adjoining regions. These intersection points were fitted to fifth-order polynomials for Mc and M» as functions of 0W. The result- ing four equations are:

Mc<!,m) = (-1-07567 x 10 )SW + (4.54862 x 10" ) 8W + (1.67529 x 10" ) 6W

+ (-5.74300 x 1O"J)0W' + (3.12362 x lO"ä)0w + (9.85932 x 10~l) (1-14)

n.- 3 \ /l « Mctm.h)- - (5.01108 x 10 ) 0W * (8.42477 x 10 ) 0W + (-4.36116 x 10" ) 0W

+ (-1.80925 x io"l)0w2 + 5.92472 x 10~2) 0W + (1.19274) (1-15)

42

Page 49: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

^(«."O = (-1.22475 x I0~1)dyis + (1.12770 x lO~2)0v/ + {1.88121 x 10_1)<9W

S

+ (-7.07909 x 1O~J)0WJ + (7.66990 x 10"*) 0W + (1.00029) (1-16)

ty.bD.h) - (3.08744 x 10"2)öw' + (1.20774 x 1O_1)0W4 + (-2.02932 x 1O~J)0W*

+ (-2.27465 x lO"')^-1 + (6.55277 x 10"2) 6W + (1.21393) (1-17)

The equations M^^ m) and M^^ ^) are used in the program which compiles the table for setting Mach number in Tunnel 16T while Mc^jin) and Mc/m ^) are used in the on-line data reduction program which evaluates Mm.

A plot of the linearized calibration equations for 0W = -1. 00 to + 1. 00 deg in increments of 0. 25 deg is shown in Fig. 1-1. The region in which linearization produced a deviation of ±0. 001 or less in M^, from the calibration data is given in Fig. 1-2.

43

Page 50: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDCTR-66-80

.028

.024

.020

.016

.012

.008

.004

. 0

- 004

1 i i 1

r * =/ i.oo? y

0.75 •— i

*•/ ^r

LOCI OF 0.50°

LOCI OF i

Me(m,h)

M fi-

c(L,n

:QI-I 0 0.25°

i

le 14) L

t^^f* ̂ y 0s

M -M «i ;

i 1

00 - c \

\ i

. 1

v& t ^

9'S' I 1

1

/ / f

-0.25» /'

1 1 / N,

s' - 1

1 / I

- 1

r~"—*

i /

"—mi 1

i \ kl \ f

\; \ -0.5C *

>

\

-.008

-.012

-"o

V 75°

_L i 1 LOO 1

4 0 6 0 8 1 0

\

1 2 1 4 l 6 J.

00

Fig. 1-1 Calibration Reduced to Linear Functions

44

Page 51: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

£

0.8 1.0 1.2 1.4

STREAM MACH NUMBER, M

Fig. 1-2 Operating Region in which Linearized Calibration Resulted in a Maximum Deviation of ±0.001 in Mach Number from Calibration Data

> m o

Page 52: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

APPENDIX II SUPPLEMENTAL CALIBRATION INFORMATION

In previous calibration, reports, such as Refs. 2 and 3, the tunnel pressure ratio has been defined as the ratio of tunnel total pressure to the static pressure at the downstream end of the diffuser. This ratio has usually been given the symbols A or A 210« ^n April 1965 this definition was changed so that the tunnel pressure ratio, Aj, is the ratio of tunnel total pressure to the compressor inlet static pressure. The correlation between A-p and A 210 *-s given in Fig. II-1. This change is applicable to all Tunnel 16T calibration reports preceding April 1965.

1.5

W2I0 1.4

1.3

1.2

Li

1.0

G

1.0 1.1 1.2 1.3 1.4 1.5

TUNNEL PRESSURE RATIO, XT

Fig. 11-1 Relation between Previous Definition of Tunnel Pressure Ratio, A21O1 or*d Present Pressure Ratio, Ay, Definition - Effective April 1965

46

Page 53: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

AEDC-TR-66-80

APPENDIX III STANDARD DEVIATION

The standard deviation, a, of a set of n numbers, xi, X2, ... xn, is approximately the root-mean-square (rms) deviation of the numbers from their average.

Even though the longitudinal deviations in Mach number from the geometric average may not be entirely a random function, the concept of random deviation may be applied to a large sample of data with some meaningful results. Mathematically applied to the Tunnel 16T Mach number data obtained from 20 orifices (n = 20) at a constant wall angle:

M_

n

iii MTSi (m-i)

\ n- 1

The standard deviation is an extremely useful distribution function since it is a measure of the distribution band. For example, 95. 4 per- cent of all numbers of a data set which has a normal distribution will fall between -2a and +2cr.

47

Page 54: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

UNCLASSIFIED Security Classification

DOCUMENT CONTROL DATA - R&D (Security clattlllcatlcr) ot tills, body ot abstract and induing annotation tituat 6* anfand whan the overall report fa committed)

1- ORIGINATING ACTIVITY (Corporate aulrtorj " |2a. REPORT 1ECURI TY CLASSIFICATION

Arnold Engineering Development Center AHO, Inc., Operating Contractor Arnold Air Force Station, Tennessee

UNCLASSIFIED 2b CROUP

N/A 3 REPORT TITLE

CHECK CALIBRATION OF THE AEDC 16-FT TRANSONIC TUNNEL

4 DESCRIPTIVE NOTES (Type o/ »port and inctuaive datem)

N/A 5 AUTHORfs; (LatC name. Himt name, irrilJaV

Gunn, J. A., ARO, Inc.

B REPORT DATE

May 1966 7a TOTAL NO. OP PACKS

55 7b NO. OP Rin

■ a. CONTRACT OR GRANT NO.

AF 40(600)-1200

b. Program Element 65402234

Sa. ORIGINATOR»» REPORT NUMBffRfSJ

AEDC-TR-66-80

9b. OTHER REPORT NOfSJ (Anr other number* »at may be »..Idn.d tfi/a raporv

N/A 10. AVA IL ABILITY/LIMITATION NOTICES

Qualified users may obtain copies of this report from DDC.

IT- SUPPLEMENTARV NOTES 12. SPONSORING MILITARY ACTIVITY

N/A Arnold Engineering Development Centex Air Force Systems Command Arnold Air Force Station, Tennessee

13 ABSTRACT

Tests were conducted in the Propulsion Wind Tunnel, Transonic (16T) of the Propulsion Wind Tunnel Facility (PWT) to determine the test section Mach number calibration and Mach number distributions. During the test, Mach number was varied from 0.50 to 1.60, and the wall angle from -1.00 to +1.00 deg, while holding tunnel total pressure at 1000 psfa and tunnel temperature at 120°F. At all Mach numbers the region from Station 1 to Station 20 was considered the test region. The results show that the tunnel calibration is a function of test section wall angle, and that all wall angles in the calibrated Mach number range produce Mach number distributions acceptable for testing. This was the first calibration after the installation of the modified main compressor utilising fiber glass rotor blades.

DD FORM t JAN a« 1473 UNCLASSIFIED

Security Classification

Page 55: JU AEDC-TR-66-80 - DTIC · 2018. 11. 8. · JU AEDC-TR-66-80 X N0V1 1967 g3335g£gSS CHECK CALIBRATION OF THE AEDC16-FT TRANSONIC TUNNEL J. A. Gunn ARO, Inc. May 1966 /yp 4Q(60Q)12QI>

UNCLASSIFIED Security Classification

KEY WORDS LINK A

BOLE WT

LINK B LINK C

ROLE WT

Transonic Flow Wind Tunnels Calibration

INSTRUCTIONS

1. ORIGINATING ACTIVITY: Enter the name and address of the contractor, subcontractor, grantee, Department of De- fense activity or other organization (corporate author) Issuing the report.

la. REPORT SECURITY CLASSIFICATION: Enter the over- all security classification of the report. Indicate whether "Restricted Data" is included Marking is to be in accord- ance with appropriate security regulations.

2b. GROUP: Automatic downgrading is specified in DoD Di- rective 5200.10 and Armed Forces Industrial Manual. Enter the group number. Also, when applicable, show that optional markings have been used for Group 3 and Group 4 as author- ized.

3. REPORT TITLE: Enter the complete report title in all capital letters. Titles in all cases should be unclassified. If a meaningful title cannot be selected without classifica- tion, show title classification in all capitals in parenthesis im.iv.edia rely following the title.

4. DESCRIPTIVE NOTES: If appropriate, enter the type of report, e.g., interim, progress, summary, annual, or final. Give the inclusive dates when a specific reporting period is covered.

5. AUTHOR(S): Enter the name(s) of authors) as shown on or in the report. Entei last name, first name, middle initial. If military, show rank and branch of service. The name of the principal »srthor is an absolute minimum requirement.

6. REPORT DAT£: Enter the date of the report as day, month, year; or month, year. If more than one date appears on the report, use date of publication. 7a. TOTAL NUMBER OF PAGES: The total page count should follow normal pagination procedures, I.e., enter the number of pages containing information.

7b. NUMBER OF REFERENCES: Enter the total number of references cited in the report. 8a. CONTRACT OR GRANT NUMBER: If appropriate, enter the applicable number of the contract or grant under which the report was written.

8b, 8c, fc 8d. PROJECT NUMBER: Entei the appropriate military department identification, such as project number, subproject number, system numbers, task number, etc

9a. ORIGINATOR'S REPORT NUMBERfS): Enter the offi- cial report number by which the document will be identified and controlled by the originating activity. This number must be unique to (his report. 9b. OTHER REPORT NUMbER(S): If the report has been ass:gned any other report numbers (either by the originator or by the sponsor), also enter this number(s).

10. AVAILABILITY/LIMITATION NOTICES: Enter any lim- itations on further dissemination of the report, other than thost

imposed by security classification, using standard statements such as:

(1) "Qualified requesters may obtain copies of this report from DDC "

(2) "Foreign announcement and dissemination of this report by DDC is not authorized."

(3) "V. S. Government agencies may obtain copies of this report directly from DDC. Other qualified DDC users shall request through

(4) "U. S. military agencies may obtain copies of this report directly from DDC Other qualified users shall request through

(5) "All distribution of this report is controlled. Qual- ified DDC users shall request through

If the report has been furnished to the Office of Technical Services, Department of Commerce, for sale to the public, indi- cate this fact and enter the price, If known.

11. SUPPLEMENTARY NOTES: Use for additional explana- tory notes.

12. SPONSORING MILITARY ACTIVITY: Enter the name of the departmental project office or laboratory sponsoring (pay- ing for) the research and development. Include address.

13- ABSTRACT: Enter an abstract giving a brief and factual summary of the document indicative of the report, even though it may also appear elsewhere in the body of the technical re- port. If additional space is required, a continuation sheet shall be attached.

It is highly desirable that the abstract of classified reports be unclessified. Each paragraph of the abstract shall end with an indication of the military security classification of the in- formation in the paragraph, represented as (TS). (S), (C). or (V).

There is no limitation on the length of the abstract. How- ever, the suggested length is from 150 to 225 words.

14. KEY WORDS: Key words are technically meaningful terms or short phrases that characterize a report and may be used as index entries for cataloging the report- Key words must be selected so that no security classification is required. Identi- fiers, such as equipment model designation, trade name, military project code name, geographic location, may be used as koy words but W'll be followed by en indication of technical con- text. The assignment of links, rules, and weights is optional.

UNCLASSIFIED Security Classification