joint research of seismic retrofitting technology for existing foundations masahiro ishida public...
TRANSCRIPT
Joint Research of Joint Research of Seismic Retrofitting Technology forSeismic Retrofitting Technology for
Existing Foundations Existing Foundations
Masahiro IshidaMasahiro Ishida
Public Works Research InstitutePublic Works Research Institute
JAPANJAPAN
“Design and Execution Manual for Seismic Retrofitting of Existing Pile Foundations“
22
M8.0Fri. 9/26/2003 4:50(JST)Thu. 9/25/2003 11:50(PST)
2: Missing
Over 300:Injured
HokkaHokkaidoidoTokachioki EQ 2003Tokachioki EQ 2003
33
Damaged Freeway Bridge
44
Nishinomiya Br.Nishinomiya Br. (Kobe EQ, 1995)(Kobe EQ, 1995)
55
Damaged Piles by Kobe EQ.Damaged Piles by Kobe EQ.
66
Joint Research of Joint Research of Seismic Retrofitting Technology forSeismic Retrofitting Technology for
Existing Foundations Existing Foundations
Public Works Research Institute
Advanced Construction Technology Center
Twelve Private Companies
Three years from 1999
77
Outline of the Micropile MethodsOutline of the Micropile Methods
Bearinglayer
Anchoringby grout
Deformed bar
Steel pipe
Pile head
Bearinglayer
Anchoringby grout
Deformed bar
Steel pipe
Pile head
Partitionedsteel pipe
Soil-cementcolumn
Partitionedsteel pipe
Soil-cementcolumn
Wings
Rotary penetration
Steel pile
Wings
Rotary penetration
Steel pile
High Capacity Micropile
ST Micropile Multi-Helix Micropile
88
Major Experiments in this projectMajor Experiments in this project
High Capacity High Capacity
MicropileMicropileST MicropileST Micropile
Multi-Helix Multi-Helix MicropileMicropile
CommoCommon Testsn Tests
Static Lateral Load Testing of Model Static Lateral Load Testing of Model FoundationsFoundations
with different kind of pileswith different kind of piles
Dynamic Lateral Load Testing of ModelDynamic Lateral Load Testing of Model Foundations with different kind of pilesFoundations with different kind of piles
Loading Tests in a CentrifugeLoading Tests in a Centrifuge
Bending TestsBending TestsVertical Loading TestsVertical Loading TestsLateral Loading TestsLateral Loading TestsTests for Workability Tests for Workability (Vertical and incline (Vertical and incline
piles)piles)Tests for the Tests for the
connection of Steel connection of Steel PilesPiles
Pull Tests for the Pull Tests for the connection of Pile connection of Pile
HeadHead
Vertical Loading TestsVertical Loading TestsLateral Loading TestsLateral Loading TestsTests for WorkabilityTests for Workability
Tests for the Tests for the connection of Steel connection of Steel
PilesPilesSkin Friction TestsSkin Friction Tests
Vertical Loading Vertical Loading
TestsTests
Tests for Tests for WorkabilityWorkability
Tests for the Tests for the connection of Steel connection of Steel
PilesPiles
99
Vertical Loading TestsVertical Loading Tests
- 16
- 15
- 14
- 13
- 12
- 11
- 10
- 9
- 8
- 7
- 6
- 5
- 4
- 3
- 2
- 1
00 10 20 30 40 50
Dep
th
(m)
0m
- 2.9m
- 4.0m
- 6.2m
- 10.5m
N Value
- 7.7m
- 8.9mSilt(M)
Soilfilling(FI)
Loam
Finesand(FS)
Clay(CL)
Finesand
Finesand
(FS)
850
300
1200
7150
1000
1500
1500
1500
500
2500
2500
9650
1465
0
Strain Gauges: Inside steel pipe 3 points: On steel bar 6 points:
Displacement seismograph : 1 point Displacement seismograph in hole : 1 point
Anchoring by grout
①
②
③
④
⑤
⑥
⑦
⑧
Steel pipe (diameter : 177.8mm)
Deformed steel bar (D51)
Anchorage zone
Effective anchoringdiameter =200mm
Anc
horing
leng
th=5
.0mSte
el p
ipes
sec
tion
Non
-ste
el p
ipes
sec
tion
Ground during loading test
1010
Vertical Loading TestsVertical Loading Tests
- 1200
- 1000
- 800
- 600
- 400
- 200
0
200
400
600
800
1000
- 150 - 120 - 90 - 60 - 30 0 30
Displacement of pile head (mm)
Load
(kN
)
Pus
h -i
n Lo
adin
gP
ull-
out
Load
ing
1111
ResultsResults
Vertical Vertical loading testloading test
Ground Ground conditioncondition
Maximum friction (N/mmMaximum friction (N/mm22))
Measured valueMeasured value Design value*Design value*
Push-in loadingPush-in loading
Hard clay layerHard clay layercc=0.87 N/mm=0.87 N/mm22 1.001.00 0.870.87
Fine sand layerFine sand layerNN-value =20-value =20
0.250.25 0.210.21
Pull-out Pull-out loadingloading※※
Fine sand layerFine sand layerAverageAverage
NN-value =40-value =400.320.32 0.320.32
* Ground Anchor Design and Execution Standards (JGS)
1212
Static Horizontal Loading Tests of Model Static Horizontal Loading Tests of Model Foundations with Piles of Different Foundations with Piles of Different
DiametersDiameters
1313
Static Horizontal Loading TestsStatic Horizontal Loading Tests
CaseCase Number of PilesNumber of Piles SpacingSpacing InclinationInclination Loading Loading MethodMethod
11 1 EP1 EP -- -- One Dir.One Dir.
22 1 MP1 MP -- -- One Dir.One Dir.
33 4 EP4 EP -- -- One Dir.One Dir.
44 4 EP 6 MP4 EP 6 MP 200 mm200 mm 00 One Dir.One Dir.
55 4 EP 6 MP4 EP 6 MP 400 mm400 mm 00 CyclicCyclic
66 4 EP 6 MP4 EP 6 MP 200 mm200 mm 1010 One Dir.One Dir.
77 4 EP 6 MP4 EP 6 MP 200 mm200 mm 2020 One Dir.One Dir.
1/5 scale
1414
Static Horizontal Loading TestsStatic Horizontal Loading Tests
0
30
60
90
120
150
180
210
0 20 40 60 80 100
Displacement of footing mm( )
Load
kN()
Case1Case2Case3Case4Case5Case6Case7
1515
(1) Design Model(1) Design Model– Rigid flame structureRigid flame structure
(2) Resistance properties in axis direction(2) Resistance properties in axis direction– Elasto-plastic model with limit of bearing capaElasto-plastic model with limit of bearing capa
sitysity
Retrofitting Effects ModelRetrofitting Effects Model
1616
(3) Resistance properties at right angles(3) Resistance properties at right angles– Elasto-plastic model with limit of PElasto-plastic model with limit of PHUHU
– PPHU HU is corrected by the ratio of the pile spacinis corrected by the ratio of the pile spacin
g and pile diameterg and pile diameter
– PPHUHU is corrected by the ratio shown in the table is corrected by the ratio shown in the table
Front Pile Others Front Pile Others
Sand Layer 1.00 0.50 1.00 0.50
Micropile Exsiting Pile
1717
(4) Bending moment – curvature relationship (4) Bending moment – curvature relationship of micropilesof micropiles– elasto-plastic modelelasto-plastic model
1818
SummarySummary
These results are reflected in These results are reflected in “Design and “Design and Execution Manual for Seismic Retrofitting Execution Manual for Seismic Retrofitting of Existing Pile Foundations with High Capof Existing Pile Foundations with High Capacity Micropiles”acity Micropiles”
We will distribute the English version of thWe will distribute the English version of the manual by CD-ROM after this session e manual by CD-ROM after this session
Next speakers introduce further informatioNext speakers introduce further information of this manualn of this manual