ivf consultation and lab design
TRANSCRIPT
STECH IVF Solutions
has been formed by well experienced team.
Among us we have more than 20 + years of experience in this field and
capable of handling the Sale and Service.
Always at your service 2
3 Always at your service
Andrology
Andrology workstation 3 feet in size & designed with optimized
environment for semen analysis, processing & Morphology.
Table heating : All new design of silicone heating coils composed in
aluminium for optimum temperature accuracy
2 Heat System : 2 independent heating systems ( table & block )
Low Noise :56dBA for uniformity & 24x365 continuous operation
HEPA Filtration : 0.3 micron Classi�cation H-14 with resistance of
130Pa & e�iciency of MPPS 99.995%
System : Built in system with optional software for analysis, IUI & freezing.
Tube warmer : A test tube warmer, built in the back wall.
ANDROLOGY WORKSTATION
4Always at your service
Made of GI with powder coat �nish
3 Di�erent Modles : 2 Feet, 3 Feet & 4 Feet
Working Table SS304
Workingarea:650 L x 600 W x 600 H in mm.
Vertical down �ow laminar system
HEPA Filtration : 0.3 micron Classi�cation H-14 with resistance of
130Pa & e�iciency of MPPS 99.995%
EBM german blower for continues e�iciency operation and noise
free
Illumination light & UV Incorporated
Additional power point inside the working area
LAF 2 FEET
Andrology
Eppendorf Tubes® 5.0 mL Safe-Lock and Screw Cap
5Always at your service
Andrology
Make: Remi
Model: R8M plus
Brushless induction Motor
LCD Display of speed & time
Imbalance detector
Safety lid lock
8*15ml swing out rotor head
CENTRIFUGE
Make: Labomed / Magmus
Model: LX300 / MLX-Tr
10x, 20x, 40x, 100x (Oil) Objectives
10x Eyepiece
MICROSCOPE
Sperm count performed from undiluted specimen.
No additional factors are necessary for calculation.
The depth of 10 microns eliminates blurring and allows
sperm to move freely
The grid is in the cover glass.
Reusable
Observation of color fringes at the four contact points
Provides a test for accuracy.
Repeated use with complete accuracy without calibration
Manufactured by state -of-the-art precision engineering.
SPERM COUNTING CHAMBER
Always at your service
Andrology
TRACEABILITY OF BIOLOGICAL SAMPLES
6
Body made of GI with powder coat �nish
Chamber made of SS304
Omron PID controller for better accuracy
Two shelves for storage your disposable and
semen samples
Temperature range from 49.9°C
Temperature accuracy : + 0.3°C
Compact design
Chamber size 420 x 420 x 400mm
Visible polycarbonate front door to view disposable and samples
Made of GI with powder coat �nish
Ormon PID controller
Temperature accuracy + 0.2°C
Temperature range ambient to 49.9°C
3 No’s of anodised aluminium blocks
Eachg blocks can hold 6 No’s of ASP tubes
Optimal 30° angle block
Easy to clean block
DRY INCUBATOR
HEATING BLOCK
Always at your service
IVF Workstation
7
Stech IVF workstation is designed with optimized environment for oocytes & embryo's.
3 di�erent models : 4 feet, 5 feet & 6 feet dual
Our Workstations meet the relevant standards as ISO 14644-1 or EN 12469
Control System: Omron German control system with self tuning for over shoot protection
3 Heat System : 3 independent heating systems ( stage, table & block )
HEPA Filtration: 0.3 micron Classi�cation H-14 with resistance of 130Pa & e�iciency of MPPS 99.995%
Monitor is �ushed to the back wall of the working area for an easy view & detailed oocyte identi�cation & embryo grading
90mm dia glass heated stage incorporated in the light opening
Aluminum composed Silicone heating Technology
Silicone withstands all environmental conditions across the globe
A patterned silicone heating system is composed in aluminium for a better accuracy & uniformity
Stage area light pass is �ush mounted on the surface with optically clear BK7 glass
IVF WORKSTATION
MONITOR
THE HEATED WORK AREA
GLASS STAGE
2.2mm Thick ITO coated glass
Always at your service
IVF Workstation
An miniature test tube warmer movable to the whole working incorporated in the workstationto facilitate the oocyte identi�cation
MINIATURE TEST TUBE WARMER
TRANSMITTED LED LIGHT SOURCE
MICROSCOPE MOUNTING
Any Brand stereo microscope may be built into the table plate.
The microscope can be �ush mounted to the table surface
Microscope is mounted in sucha way that the eye piece projects outside to validate contamination protocol
LOW NOISE LEVELYears of experience in laminar �owtechniques has been used to provide the lowest possible noise 56dBA for uniformity & 24x365continuous operation
8
OPTIONAL
BUILTIN WORKSTATION INCUABTOR
Always at your service
Temperature range up to +50°C4 model sizes (with a chamber volume of 50, 105, 150 & 240 litres)
Fail-safe, FDA-compliant logging of temperature, CO₂, O₂ humidity, open door time dataBattery-bu�ered Control COCKPIT The operating display, logging and CO₂ control are fully functional ever during a power failure
Visual and acoustic alarm as well as alarm noti�cation to mobile phones if the individually adjustable temperature, CO₂, O₂ , or humidity ranges are exceeded
Active humidity control : optionalThe interior chamber, including all installations and sensors, can be sterilised at +180°C in a 60-minute programme
Two gas connections with quick release connectors for automatic switch-over of gas bottles : Optional
Electro polished, seamlessly welded chamber
Electronic control for active humidi�cation and dehumidi�cation (40 to 97 % rh)
Control of oxygen concentration by introducing nitrogen, range from 1 % to 20 % O₂ : OptionalUSB and Ethernet connections as well as a data logger with a ten-year storage capacity. Data can be read and programmes can be uploaded by remote
An alarm notification to your mobile phone guarantees the safety of your chamber load. The battery-buffered ControlCOCKPIT ensures fully functional CO2 control, even during power failures.
CO2 Incubator
9
10Always at your service
No Door latches
Removable & Autoclavable dish plates
Heater bottom & lid
Advanced control system with 4.3" Touch screen
Individual chamber & lid temperature control
Individual chamber Gas On/O�
Controlled gas �ow rate in ml/min
Door sensor cuts o� gas when door is open
Door open alaram in seconds user con�gurable
Cylinder elapsed in days Configurable Alarm Setting
Crescenta
11 Always at your service
CARL ZEISS WITH S MICROMANIPULATOR
Green Filter, d = 32x2 mm, Neutral density �lter 0.06
Optical Equpiment Phase Contrast and PlasDIC
Objective LD A-Plan 5x/0.12 Ph1 M27, 10x/0.25 Ph 1 M27 & 20x/0.35 Ph1 M27
LD Condenser 0.4 for slider, for H, Ph, PlasDIC, VAREL for objectives 5x - 63 x 53mm working distance
PlasDIC Module LD A-Plan 10x-63x for contrast slider 10x29mm
Camera Adapter 60N-C 2/3" 0.5x
S-micromanipulator
MO-20 3 Dimensional with Joy-stick (Micromanipulator)
Universal Joint, X/Y/Z 20mm each,2mm one revolution handle, Joy-stick on X/Y plane 2 mm/max.
IA-1 Pneumatic Injector
Injection holder set, 15mmGlass stage warmer
Carl Zeiss Microscopy GmbH - Germany Inverted Microscope Axio Vert.A1
S Micro Manipulator
12Always at your service
Microscopes
Optional modules: Temperature, Humidity, VOC and pH
Optional modules: Temperature, Humidity, VOC and pH
True Trinocular with 50/50 divisions
Visualize objects in �elds of view up to 122 mm. expandable upto 287mm
Trinocular head with 0.5X reduction adaptor
Large Field of View and Apochromatic Correction
Large zoom range 8:1Interchangeable front optics
STEREO STERMI 508
PRIME STAREasy to operateRobust and durableQuality optics from Carl Zeiss10X eyepiece4X, 10, 40X & 100X objectives
Numerous innovative solutionFlexible through its modularity
Excellent price/performance ratio
True Trinacular with 50/50 divisions
Visualize objects in �elds of view up to 110 mm.expandable upto 185mm
Trinocular head with 0.5X reduction adaptor
Large Field of View and Apochromatic CorrectionZoom range 5:1Interchangeable front optics
STEMI 305
Always at your service
Easy to clean smooth, seamless chamber surface
Fanless design for vibration and turbulence protection
Interactive and clearly arranged 7” touch screen
Outer door with magnetic closure concept dual direction inner door latches (pull or turn to open)
4 segmented inner doors Optional: 8 segmented
Four shelf provides more usable volume
Removable water tray
Access port 2 nos
CellXpert 170i
Incubator
13
CONSTRUCTION
3 Temperature sensors placed in 3 location & calculated mean value is controlled for accurancy
TEMPERATUREPrecise temperature by calculation mean value of 3 temperature sensor placed in di�erent location
180°c High Temperature Disinfection (HTD)
Dual-channel sterilizable NDIR co2 sensor give more accuracy, fast recover and stable performance
Any time upgradable to oxygen control (Trigas) Humidity monitoring and water level sensor
Zirconium oxygen sensor for long life and accuracy
COMMUNICATIONItegrated USB port in front
BMS relay and 4-20mA interface optional
VisioNize online real time control systems
C170Push button interface
140°c High Temperature Disinfection (HTD)
GALAXY 48 R Small CO2 incubator with total volume 48L /1.7ft with high usable space
Seamless stainless steel chamber, 120c sterlization (4 h), 2 segmented innerdoor (optional)
Large LCD display with push button interface
Six-sided direct heating (including window)
Enhanced vibration and turbulence protection
Integrated alarm/building management system (BMS) relay & 72 -hour log
Low gas consuption
Optional 120 c sterilization, 2-segmented inner door, 02 control(for hypoxic experiments), humidity monitorign, stacking kit
Always at your service 14
CENTRIFUGE 5702 / RH
Compact, Quiet operation & Low access height
Stainless steel rotor chamber is rust free & easy to clean
Imbalance detection for maximum safety
Key lock to prevent accidental parameter changes
2 program keys to store routine procedures
Temperature range -9°C to +42°C
Active heating guarantees temp accuracy
Timer starts only when the selected RPM is reached
PIEZOXPERTFast and simple sample processing due to intuitive
operation
Reproducible parameter setting
Program keys to save your experimental
parameters
Trigger impulses with an ergonomic foot control or
rotary knobs right on the device
Optical feedback of triggered impulses
Additional "Clean" function for simple removal
of contamination on the outside of the capillary
Centrifuge / Piezoxpert
Always at your service
One Joystick for precise movement control in 4 axes: X, Y, Z and X/Z (axial)
Programmable Z-axis limit for preventing capillary breakage
Un ique DualSpeed joystick for precise, instantaneous control and positioning using two di�erent speed modes
Dynamic movement control for covering longer distances or speeding up sample processing.
Ergonomically shaped control panel for fatigue-free work
Simple and quick capillary and sample change using automated home function
Selection and programming of additional functions(e.g. storage of up to 5 positions, limit, Y-o�)
Comfortable, individual speed adjustment
Step size (computational resolution): <20 nm Speed: 0 – 10,000 µm/s
Easy adjustable angle from 0° to 90° Swivel joint to allow for easy capillary and sample exchange
One-hand mounting of capillary holder
Swivel out function for easy capillary exchange.
TransferMan 4r
Micromanipulator
15
Always at your service
Coarse and �ne drive for precise and intuitive sample control
Improved rotary knob design for better handling and easier cleaning
New grip head 4 system for simple capillary change and higher user safety
Capillary holder 4 with markings for easier positioning
Position indicators and marking for in/out to reduce risk of user errors
Stable, nonslip base plate
Improved oil-�lling system for minimal interruptionof the work�ow
Optimized piston/cylinder system for ultra�ne sensitivity
Volume change per revolution: 1 µL / 10 µL
Cylinder volume: 1,000 µL
Minimum adjustable volume: <1.5 nL
Injection tube:1.3 m length, inner diameter 1 mm,outer diameter 2 mm
Non-hydraulic system for oil-free manipulation and injection of cells
Piston position scale allows to set air volume and injection characteristics according to individual needs
Volume change per revolution: 60 µL / 600 µL
Cylinder volume: 10 mL
Minimum adjustable volume: <100 µL
Injection tube:1.3 m length, inner diameter 0.5 mm, outer diameter 2 mm
CellTram 4r Oil/Air
16
CellTram 4r Oil/Air
CellTram 4r Oil
CellTram 4r Air
Always at your service
Accessories OT
Digital Low volume OOCYTE Aspiration pump
Uniform �ow pattern
Max Vacuum attained 400 mm of Hg
Over �ow bottle, adequate for the cyst aspiration
Autoiclavable tubings, bottles & cork
Battery backup upto 30 mins
Wired cum wireless foor pedal �rst time in ART
Mobile trolley for oocyte retrival
Heated smooth tabletop & heated drawer
In Built heating block
Humidi�er Stand
Shelf for storage
3 Adjustable temperature with key
Easily movable with lock
ASPIRATION PUMP
TROLLEY
17
Always at your service
AVT
Modles: MS Powder coated / Glass Top SS AVT
The anti-vibration handles from light to heavy
inverted microscopes
MS powder coated AVT top with stainless
steel platform / In SS AVT top is frosted
toughened glass platform
The damping systems use column-friction
for optimal results.
An equilibrated and isolated platform for
the inverted microscope
ANTI-VIBRATION TABLE
Eliminating vibrations and ensuring a fast dampening e�ect is essential when working
with inverted microscopes
Designed and developed to meet the requirement of ICSI procedure
Working range 15-72kg.
Roomy workspace around the
micro manipulating systems.
Space for mini incubator
Mild Steel powder coating shelf for
accessories
Dimension: 1200 L x 700 W x 705 H
in mm.
18
Always at your service
4 Stages of �ltration
Optional UVC Germicidal
Removes VOC & CAC e�ectively
Noiseless design ( less than 56dBA )
Standby / Run Mode
E�ectively covers area up to 2000 sq ft
Continuous operation runs 24hrs 365days
70% recirculation 30% fresh air
TOWER
Stage 1 -10 �lter – dust & bigger
Stage 2 -V blank carbon �lter -
Molecular Contaminant Removal – VOC/CAC
Stage 4 -HEPA – 0.3 �lter –
particulates – 99.97%
Stage 3 -5 �lter – carbon &
bigger than 5
Air Purification
19
Always at your service 20
Air Purification
Movable to required area
Activated Carbon impregnated with alumina
& KOH removes molecular contaminants
HEPA �ltration removes particulate contaminants
4 speed option for variable room size.
51dBA noise level so low in the industry
Maximum Air Flow: 300 Cubic Feet/minute
Air Exchanges/Hour in 150 sq. ft.: 9.53
E�ective Coverage: 150 sq. ft.
100% recirculation
MOBILE AIR
Improved Air quality = Higher Fertilization Rates
100 % Air recirculation in IVF lab
Carbon �lter will remove VOC & CAC free
Class 10,000 environment
HEPA �lters will remove 0.3 micron particles
Blowers (2 nos) with Noise level < 52 dBA
Standby & running mode
Magnehelic gauge will represent �lter life time
Easy movable with wheels
Covers upto 200 Sq.Ft area
Optional: Germicidal UVC
TOWER RECIRCULATION
Always at your service
WorkstationIncubator
Workstation Incubator is an compactable incubator
which has 4 dish chamber with premixed gases
of CO2, N2, O2
The Workstation incubator provides a good solution for
short time culture management during oocyte selection
& denudation
Temperature range ambient to 40°C
Temperature accurancy +0.2°C
Analog �ow meter for adjusting �ow rate of pre mixed gas.
Optimal Digital �ow meter
Flushing and purge function for fast recovery in the chamber
Chamber with space for 2 culture dishes
Alarm for gas �ow interuption
Temperature can be easily controller
Dish plate is removable & autoclavable
Can be used as warming chamber too.
21
Always at your service 22
SECURITY FEATURES
TRI-GAS MIXER
The Tri-Gas Mixer delivers gas mixture of the desired co2 and 02 concentration with output pressure in the range of 0-2 bar (0-30 psi). Delivery pressure is easily regulated by adjusting the knob of the embedded pressure gauge. The device is equipped with a mixing tank to ensure the highest composition stability even when the required output �ow is variable.
Models available with maximum output �ow rate of 1.5 L/min and 15 L/min.The actual �ow rate delivered automatically adjusts to match the requirement of theequipment connected. Tri-Gas Mixer is compatible with any mini incubator available on the market
To enable the safety routines the Tri-GasMixer must also be connected to a pre-mixed back-up cylinder containinggas of the desidered concentration.The mixer will automatically switch to the backup pre-mixed cylinder if any of the following condition occurs.
CO2-O2 SENSOR CALIBRATION The CO2-O2 sensor module stores the calibration in local memory. The CO2-O2sensor module can be conveniently calibrated on-site with intutive routines or can beeasily extracted from the Tri-Gas mixer, replaced with a spare CO2-O2 sensor moduleand sent out for calibration. In both cases, there is no need to disconnect or turn o�the Tri-gas Mixer nor to discontinues the gas supply to the incubator
AVAILABLE MODLESThe Tri-gas Mixer is available in two models.with maximum output �ow rate capacity of1.5 and 15L/min. Besides internal components,the two models di�er by the size of the mixingtank.
Tri-Gas Mixer
23 Always at your service
Quality ControlGadgets
User-friendlytouchscreeninterface
Compatiblewithanyincubatoronthemarket
Di�usionorPumpgassamplingmodes
Pumpsuctionrate100ml/min
Samplingtubeandde-humidi�cationkitincluded
Longtermlogging
MicroUSBfordatadownload
Calibration:
a) Removable sensors can be shipped to certi�ed laboratories to be calibrated. Calibra-
tion is stored in sensor on-board mem- ory. Leo reads calibration upon sensor installation
b) In situ sensor calibration via LEO calibration
LEO PORTABLE METER
C02 - 02 SAMPLING
T Modules
LEO is a battery operated, handheld analyzer designed to meas- ure CO2, O2, Temperature, VOC, Relative Humidity and pH.
Optional modules: Temperature, Humidity, VOC and pH
Optional modules: Temperature, Humidity, VOC and pH
Optional modules: Temperature, Humidity, VOC and pH
Leo features two external temperature modules, which can operate at the same time:
T1 is a small, �exible immersible thermocouple, ideal for measurements in liquids, such as the culture mediain the dish.
T2 is a thermistor, ideal for measurementsof incubator tem- perature, accessed through the sampling port.
Each sensor module stores calibrationdata in its own local mem- ory, that LEO reads upon connection.
Includes CO2 and O2 sensors.
Di�usion Mode
Pump Mode
24Always at your service
Quality ControlGadgets
THEROMOMETERMake : OmegaDual K type micro droplet thermocoupleThermocouple o�set Adjustment Data Storage for 120 SamplesProtective Rubber coverAuto-Range: 0.1/1° Resolution
VOC METERReal time indoor air quality and alarm
0 – 20ppm Qualitative VOC measurements Temperature and humidity detection and display
Three-color backlit LCD and Buzzer alarm
High quality technics elegant appearance & CE-approval
PARTILCE COUNTERMake : Dylos
Continuous reading with battery backup
Up to 30 days of history data stored Immediate response to changing environment
True Laser Particle CounterMeasures 0.5micron & 5micron Sizes small and large particles
LD Condenser 0.4 for slider, for H, Ph, PlasDIC, VAREL for objectives 5x - 63 x 53mm working distance
Always at your service
Data Logging
25
DEVICES FOR IVF LABHere are the solutions that SINTESY proposes for monitoring,alarm ma- nagement and automation needs, speci�c toIVF laboratories, cryobanks and biobanks.
Temperature andlevels of aluminiumdewars are monitoredthrough the insertionof a shaped rod �xedto speci�c probesconnected to SINTESY S210.SmartSensor V5x device.Also available with wireless probes connected to V6x model.
SINTESY S310.cryoLink is the only device on the market that can completely control several cryogenic freezers of di�erent brandswithout modifying the mechanics and electronics of the device, preserving the warranty and certi�cation.
SINTESY S310.cryoLink has a 4.3” colour LCDdisplay showing the temperature, level and alarm detectedby the electronic of cryogenic freezer.
By inserting probes inside the refrigerators(+4/-20°C) or mechanical freezers (-80°C) SINTESY S210. SmartSensor V5xdetects temperature as wellas alarms and the door status deriving from the equipment’selectronics through dry contacts.
SINTESY.eagle.S2000 is aportable device able to detect temperature values during the shipment of biological material.SINTESY.eagle.S2000usesthe data managementsoftware SINTESY.eagle.easy.
SINTESY.eagle. S182is the SINTESY solution for the access controlin cryobanks and laboratories with recording on a dedicated database.
SINTESY S310.SmartLink V2x is a device used to monitor temperature, CO2 and O2 concentration inside the incubators, directly, through a communicationportor by inserting external probes capable of carrying out measurements simultaneously or in addition to those taken directly from the equipment.
TEMPERATURE AND LEVEL MONITORINGOF DEWARS
MONITORING OF CRYOGENIC FREEZERS
TEMPERATURE MONITORING OF THE DRYSHIPPERS DURING THE SHIPMENT
OF BIOLOGICAL SAMPLES
TEMPERATURE MONITORING OF REFRIGERATORSAND MECHANICAL FREEZERS
TEMPERATURE, CARBON DIOXIDE ANDOXYGEN CONTROL OF THE INCUBATORS
ACCESS CONTROL
26Always at your service
Data Logging
Gas (O2 and CO2), in order to ensure the safety of operators, with possible interaction with ventilation systems;Temperature and relative humidity, in order to record the handling conditions of biological samples;Di�erential pressure between environments, where air contamination is a critical factor (clean room).
Thanks to SINTESY. eagle.lab it is possible to monitor, in real time, the status of the laboratories, including all the departments located on di�erent levels and in di�erent buildings.The devices monitored can be: cryogenic freezers with LN2, mechanical freezers, oxygen and carbondioxide sensors, incubators, access control, ventilation system. SINTESY. eagle.lab acquires the data collected from the various equipment through the device SINTESY S200.smartOxygen.SINTESY.eagle.cryo is a SCADA software dedicated to the supervision and automation of cryogenic freezes in cryobanks.
SINTESY.eagle.easyis a wireless solution for monitoring the temperature of cryogenic freezers, especially during shipment.
SINTESY.eagle.cryo acquires the datacollected by the various equipment through the SINTESY S300.SmartPLC device.
SINTESY.eagle.trace is a modular system forthe identi�cation of position of biologicalsamples and their traceability in storagesystems used in laboratories, cryobanks andbiobanks. Able to handle barcodeidenti�cation, it integrates perfectly withSINTESY.eagle.cryo and SINTESY.eagle.lab.
SINTESY.eagle.lab is a SCADA(Supervisory Control and Data Acquisition) system dedicated to the supervision of laboratories.
SINTESY.S210.smartSensor is an innovativeenvironmental sensor with a 4.3” LCD colour display and touch screen technology,available in a small, stylish case. Versatilesensor (expected lifetime of �ve years)to detect the presence of gas,temperature and relative humidity,di�erential pressure.
ENVIRONMENTAL MONITORING OF:
SOFTWARE FOR SUPERVISION OF LABORATORIES AND CRYOBANKS: SINTESY.eagle®
TRACEABILITY OF BIOLOGICAL SAMPLES
Always at your service
Antimicrobial Modular Lab
27
MONITORING OF CRYOGENIC FREEZERS
MicroGuard antimicrobial wall cladding, makes easy work of hygiene compliance to the highest standards at medical facilities. Compared to conventional wall claddings, MicroGuard o�ers a huge number of advan-tages, waging war on microbes with its specially designed surface
Antimicrobial e�ect also e�ective against MRSAEasy to cleanHighly chemical-resistant Extremely scratch-resistantSuper Hydrophobic Ray Hardened SurfaceNanoscale microstructure which pro-duces a low surface tension of <18 mN/m.
Silver ions can tie nonspeci�cally to the cell surface and disrupt the cell membrane to enter the microbe and dis-organise the membrane structure
Always at your service
Vitrification
TRACEABILITY OF BIOLOGICAL SAMPLES
28
This is the storage tub for liquid nitrogen. Its inner container is made up of special high quality stain-less steel that can be sterilized using 70% alcohol or disinfectants used in IVF. Its outer box is made up of a light weight, sturdy aluminium. Both these con-tainers are separated by an e�ective insulator that minimizes LN2 evaporation rate and keeps inner cool temperature maintained for a long time. A light source is provided to make crucial step of cell loading, clearly visible.
CRYO TUB
CRYO BLOCKThis is the heart of device. It has a very speci�c design that maintains near liquid nitrogen tempera-ture throughout the procedure. This can be steril-ized by autoclave, 70% alcohol, or any disinfectant used in IVF. The unique arrangement of the cross section holes makes ‘Close’ system as e�ective as ‘Open’ one, without cells touching the liquid nitro-gen. The markings on the surface make it easy to identify patient speci�c carrier. The smaller holes on the surface are meant to carry crucial step of vitri�cation. The larger holes are designed to hold carriers temporarily after vitri�cation till stored in main storage tank.
CRYO LOADThis is the carrier system to load cells to be cryopre-served. It has two parts. 1- The outer sleeve. It is inserted into one of the smaller holes of the surface of CRYOBLOCKTM before loading cells. 2- Main carrier. After exposing cells to suitable cryopro-tectants for optimum time duration, they are loaded on the transparent strip of main carrier and inserted into the outer sleeve, already equilibrated with cool temperature.
Always at your service
Test Kits
MONITORING OF CRYOGENIC FREEZERS
29
CANFRAGRaw / washed / freshed / frozen samples can be analysed.User friendlyEasily interpretableRequired minimum time period for process
CANMORPHCanmorph minimize the damagesFresh, diluted, frozen / thaw semen can be analysedFollow WHO and Krugeres strict morophology criteria
Easy to perform
CANROSEasy to performAnalysis from core semen sampleEasy to interpretReliable and reproducable
CANSUREVOC free, odorlessRemove stain easlyNon alcholoic, non toxic, non corrosive, non stickyE�ective over bacteria, fungai and virus within 15 minutesMinimum waiting time is required after sterlizing with Cansure.
30Always at your service
Needle & Catheter
TRACEABILITY OF BIOLOGICAL SAMPLES
PICKUP NEEDLE
CATHETER
Single lumen asperation needle17 gauge / 33 cmEcotip - clear view of needle tip in ultra sound.ETO sterilized
75 mm x 200 mtrsBulbus tip - eases passage though the cervixOuter sheath marked to con�rm the distance travelled.Pre curved guiding catheter facilitates easy insertion.
31 Always at your service
Consumables
epT.I.P.S.® Singles
Eppendorf Conical Tubes 15 mL and 50 mL
Eppendorf Tubes® 5.0 mL Safe-Lock and Screw Cap
Cell Culture Dishes
32Always at your service
Consumables
Eppendorf Serological Pipet
Eppendorf Research® plus
Eppendorf Research® plus
Tip