ITEM#0293809

BLOWER ACCESSORY

Questions, problems, missing parts?Beforereturningtoyourretailer,callourcustomerservicedepartmentat1-877-886-5989,8:00a.m-4:30p.m.,EST,[email protected].

PC-FANQEB-1104

MODEL#QEB100Españolp.35

2

PART DESCRIPTION QuantityA PowerCord 1B Blower 1C TemperatureSensor 1D ConnectorWires 1E RockerSwitch 1

PACKAGE CONTENTS

A

C

B

D

E

3

HARDWARE CONTENTS

AA

2

10

CableTie

M4.2X8Screw

WARNINGS AND CAUTIONS

WARNING• Readallinstructionsandwarningscarefullybeforestartinginstallation.Failuretofollowthese

instructionsmayresultinapossibleelectricshock,firehazardandwillvoidthewarranty.• Readallinstructionsbeforeusingthisappliance.• Ifpossiblealwaysunplugthisappliancewhennotinuse.• Donotoperateanyheaterwithadamagedcordorplugoraftertheappliancemalfunctions,

hasbeendroppedordamagedinanymanner.• Anyrepairstothisapplianceshouldbecarriedoutbyaqualifiedserviceperson.• Undernocircumstancesshouldthisappliancebemodified.Partshavingtoberemovedfor

servicingmustbereplacedpriortooperatingthisapplianceagain.• Donotuseoutdoors.• Neverlocatethisappliancewhereitmayfallintoabathtuborotherwatercontainer.• Donotruncordundercarpeting.Donotcovercordwiththrowrugs,runnersorthelike.

Arrangecordawayfromtrafficareasandwhereitwillnotbetrippedover.• Todisconnectthisappliance,turncontrolstotheoffposition,thenremoveplugfromoutlet.• Connecttoproperlygroundedoutletsonly.• Thisappliance,wheninstalledmustbeelectricallygroundedinaccordancewithlocalcodes,

withthecurrentCSAC22.1CanadianElectricalcodesorforUSAinstallations,followlocalcodesandtheNationalElectricCode,ANSI/NFPANo.70.

• Donotinsertorallowforeignobjectstoenteranyventilationorexhaustopeningasthismaycauseanelectricshock,fireordamagetheappliance.

• Topreventpossiblefire,donotblockairintakesorexhaustinanymanner.• Usethisapplianceonlyasdescribedinthismanual.Anyotherusenotrecommendedbythe

manufacturermaycausefire,electricshockorinjurytopersons.• Avoidtheuseofanextensioncordbecauseoftheriskofoverheatingthecordandtherisk

offire.Extensioncordsarefortemporaryuseonly.Ifanextensioncordmustbeused,itmustbeUL/CSAcertified,ratedat10A(1250W),125Vmaximumwith16AWGminimumandconstructedoftwocurrentcarryingconductorswithground.Aheavydutyextensioncordwiththeshortestlengthpossiblefortheconnectionisrecommendedandmustnotbelongerthan50ft.(15.2m).Donotcoilorcovertheextensioncord.

BB

PicturePart Description Quantity (Showntosize)

Notshowntosize

4

Fig.1

ASSEMBLY INSTRUCTIONS

PREPARATION

Beforebeginningassemblyofproduct,makesureallpartsarepresent.Comparepartswithpackagecontentslist.Ifanypartismissingordamaged,donotattempttoassembletheproduct.Contactcustomerserviceforreplacementparts.

EstimatedAssemblyTime:60minutesToolsRequiredforAssembly:PhilipsScrewdriverandWireCutter

1.Unscrewandremovethetopcoverofthefireplace.SeeFig.1.

Beforeinstallingtheblower,becertaintoturnofftheunit,andallowtimeforunittocooldown.

This blower contains assembly instructions for the following models and item numbers CRHED200TA3 (Item # 0328247), and ED series.For the CRHQD250T (Item # 0293811), CRHSD25RT (Item # 0328253), CRHFD400RT-M-M (Item # 0328248), BD23 series, Q stove, PCSD25RT series and FBD400 series see page 14 - 28.

5

Hardware Used

M4.2X8screw x3AA

Fig.2

Fig.3

2.Attachthepowercord(A)tothefireplacewithM4.2X8screws(AA)onthetopcover.SeeFig.2.

3.Attachtheblower(B)assemblytothetopcoverwithM4.2X8screws(AA).SeeFig.3.

Hardware Used

M4.2X8screw x4AA

A

AA

B AA

6

Fig.44.AttachthegroundingporttoshellboardwithM4.2X8screw(AA);refertogroundinglabel.Besuretoinsertthegasketbetweentheshellboardandthegroundingport.SeeFig.4.

Hardware Used

M4.2X8screw x1AA

5.Inserttheblowerconnector(maleport)intotheconnector(femaleport)toprotectingjacketinthefireplace.SeeFig.5.

Fig.5

AA

Male port

Female portFemalePort

MalePort

7

Fig.66.Insertthemaleport,whichisontheblackpowersupplywire(markedP2),intothecorrespondingfemaleport(markedP2).SeeFig.6.

Fig.77.Insertthefemaleport,whichisonthewhitepowersupplywire(markedP1),intothecorrespondingmaleport(markedP1).SeeFig.7.

P1

8

Fig.88.IMPORTANT:Bundlethewiringtothetopboardwiththecabletie(BB).Thisistoavoidanyheatdamagetotheinsulationboard.SeeFig.8.

Hardware Used

CableTie x1BB

Fig.99.Attachtemperaturesensor(C)tothebackofthefireboxwithM4.2X8screws(AA).SeeFig.9.

Hardware Used

M4.2X8screws x2AA

BB

C

AA

9

Fig.1010.InsertthewiresmarkedwithAUTO,OFFandMANintowireslotontherightcorner.Feedthemasclosetothebottomaspossible.SeeFig.10.

Fig.1111.Connecttwoblackandyellowwires(femaleports)makedT1andT2withthetwomaleportsonthetemperaturesensor(C).SeeFig.11.

Fig.1212.Unscrewtwoscrewsonthegrill.Removethegrillandlogs.SeeFig.12.

C

T1 T2

AUTO

OFF

MAN

10

Fig.1313.Unscrewthecontrolpanel(twoscrews).Pullthecontrolpaneloutwithoutdisconnectingtheignitorwire.SeeFig.13.

Fig.1414.FeedtheAUTO,OFF,MANconnectorsthroughtherockerswitchholeontheleftofthecontrolpanel.SeeFig.14.

Fig.1515.ConnecttheAUTO,OFF,MANwirestothethreecorrespondingmaletabsontherockerswitch(E).SeeFig.15.

E

AUTO

OFF

MAN

IGNITOR

11

Fig.1616.Pushtherockerswitch(E)intothecontrolpanel.SeeFig.16.

Fig.1717.Re-attachthecontrolpanelwiththetwoscrewstakenoffinstep13.SeeFig.17.

Fig.1818.Laythelogsaccordingtotheoriginallayout.Refertomanualforloglayout.SeeFig.18.

E

12

Fig.1919.Re-attachthegrillwiththetwoscrewstakenoffinstep12.SeeFig.19.

Fig.2020.Re-attachthetoppanelwiththescrewstakenoffinstep1.SeeFig.20.

Fig.2121.Pushtheprotectiontabintomakeitembedintothesurfaceoftopcover.

Protection TabProtectionTab

13

Installation blower assembly position

Installwireandgrounding

Installtemperaturesensor

Installrockerswitch

Installblower

14

Fig.1

1.Unscrewandremovethebloweraccesspanel.SeeFig.1.

Beforeinstallingtheblower,becertaintoturnofftheunit,andallowtimeforunittocooldown.

Fig.22.Attachblower(B)ontothebloweraccesspanelwithM4.2X8screws(AA).SeeFig.2.

Hardware Used

M4.2X8screws x4AA

B AA

Instruction for the models CRHQD250T (Item # 0293811), CRHSD25RT (Item # 0328253), CRHFD400RT-M-M (Item # 0328248), BD23 series, Q stove, PCSD25RT series and FBD400 series.

15

Hardware Used

M4.2X8screw x3AA

Fig.3

Fig.4

3.Attachthepowercord(A)tothebloweraccesspanelwithM4.2X8screws(AA).SeeFig.3.

4.Attachthetemperaturesensor(C)tothebackofthefireboxwithM4.2X8screws(AA).SeeFig.4.

Hardware Used

M4.2X8screw x2AA

A

AA

C

AA

16

Fig.5a5.InsertthewiresmarkedwithAUTO,OFFandMANintowireslotontherightcorner.Feedthemasclosetothebottomaspossible.SeeFig.5aand5b(topview)Fig.5c(topview)(ForModel#PCSD25RTonly).

Fig.5b

Fig.5c

17

Fig.66.Connecttwoblackandyellowwires(femaleports)markedT1andT2withthetwomaleportsonthetemperaturesensor(C).SeeFig6.

Fig.77.Insertthefemaleport,whichisonthewhitepowersupplywire(markedP1),intothecorrespondingmaleport(markedP1).SeeFig.7.

Fig.88.Insertthemaleport,whichisontheblackpowersupplywire(markedP2),intothecorrespondingfemaleport(markedP2).SeeFig.8.

T1 T2

C

P1

18

Fig.1010.AttachthegroundingporttothetabontherightsideofthebloweraccessholewithM4.2X8screws(AA).SeeFig.10.

Fig.1111.Pushthegroundingtabinwards(approximately60degrees).SeeFig.11.

Hardware Used

M4.2X8screw x1AA

Grounding Tab

AA

Grounding Tab

GroundingTab

GroundingTab

Fig.9

9.Inserttheblowerconnector(maleport)intotheconnector(femaleport)toprotectingjacketinthefireplace.SeeFig.9. Male port

Female portFemalePort

MalePort

19

Fig.12

Hardware Used

12.Bundlethewiringwiththecabletie(BB).SeeFig.12.ForModel#CRHQD250T(Item#0293811),andQstoveonly.

CableTie x1BB

Fixed Hole

BB FixedHole

Fig.13

Hardware Used

Hardware Used

13.Bundlethewiringwiththecabletie(BB).SeeFig.13.ForModel#CRHSD25RT(Item#0328253),Model#CRHFD400RT-M-M(Item#0328248),andPCSD25RTonly.

CableTie

CableTie

x1

x1

BB

BB

FixedHole

Fig.14

14.Bundlethewiringwiththecabletie(BB).SeeFig.14.ForModel#BD23seriesonly.

FixedHole

20

16.Unscrewtwoscrewsonthegrill.Removethegrillandlogs.SeeFig.16.ForModel#CRHQD250T(Item#0293811),Qstove,andBD32seriesonly.

Fig.16

Fig.15

17.Rotatinghandle,openthedoor,removethelogs.SeeFig.17.ForModel#CRHSD25RT(Item#0328253),

Fig.17

15.Bundlethewiringwiththecabletie(BB).SeeFig.15.ForModel#FBD400seriesonly.

FixedHole

Hardware Used

CableTie x1BB

21

18.Rotatinghandle,openthedoor,removethelogs.SeeFig.18.ForModel#PCSD25RTonly.

Fig.18

Fig.1919.UnscrewscrewsforfixingfrontlogbracketandControlPanel.SeeFig.19.ForModel#CRHQD250T(Item#0293811),Qstove,andBD32seriesonly.

Fig.2020.Unscrewthescrewsforfixingcontrolpanel.SeeFig.20.ForModel#CRHSD25RT(Item#0328253),andPCSD25RTonly.

22

21.Unscrewscrewsforfixingcontrolpanel.SeeFig.21.ForModel#CRHFD400RT-M-M(Item#0328248),andFBD400seriesonly.

22.Unscrewscrewsforfixingthedoor.SeeFig.22.ForModel#BD23seriesonly.

Fig.21

Fig.22

Fig.2323.FeedtheAUTO,OFF,MANconnectorsthroughtherockerswitchholeontheleftofthecontrolpanel.SeeFig.23.ForModel#CRHQD250T(Item#0293811),Qstove,andBD32seriesonly.

23

Fig.2525.ConnecttheAUTO,OFF,MANwirestothethreeecorrespondingmaletabsontherockerswitch(E).SeeFig.25.

E

AUTO

OFF

MAN

Fig.2424.FeedtheAUTO,OFF,MANconnectorsthroughtherockerswitchholeontheleftofthecontrolpanel.SeeFig.24.ForModel#CRHSD25RT(Item#0328253),CRHFD400RT-M-M(Item#0328248),PCSD25RT,andFBD400seriesonly.

Fig.2626.Pushtherockerswitch(E)intothecontrolpanel.SeeFig.26.ForModel#CRHQD250T(Item#0293811),Qstove,andBD32seriesonly.

E

24

Fig.2727.Pushtherockerswitch(E)intothecontrolpanel.SeeFig.27.ForModel#CRHSD25RT(Item#0328253),CRHFD400RT-M-M(Item#0328248),PCSD25RT,andFBD400seriesonly.

E

Fig.28

28.Re-attachthecontrolpanelwiththetwoscrewstakenoffinstep16.SeeFig.28.ForModel#CRHQD250T(Item#0293811),Qstove,andBD32seriesonly.

Fig.2929.Re-fixControlPanel.SeeFig.29.ForModel#CRHSD25RT(Item#0328253),andPCSD25RTonly.

25

Fig.3030.Re-fixControlPanel.SeeFig.30.ForModel#CRHFD400RT-M-M(Item#0328248),andFBD400seriesonly.

Fig.3131.Laythelogsaccordingtotheoriginallayout.Refertomanualforloglayout.SeeFig.31.ForModel#CRHQD250T(Item#0293811),QstoveandBD32seriesonly.

Fig.3232.Laybackthelogsaccordingtotheoriginallayout,andshutthedoor.SeeFig.32.ForModel#CRHFD400RT-M-M(Item#0328248),andFBD400seriesonly.

26

Fig.33

Fig.34

33.Laybackthelogsaccordingtotheoriginallayout,andshutthedoor.SeeFig.33.ForModel#CRHSD25RT(Item#0328253)only.

34.Laybackthelogsaccordingtotheoriginallayout,andshutthedoor.SeeFig.34.ForModel#PCSD25RTonly.

Fig.3535.Checkallthewires,thenre-attachbloweraccesspaneltothefireplace.SeeFig.35

27

Installation blower assembly position For Model # CRHQD250T (Item # 0293811), and Q stove.

Installrockerswitch

InstallblowerInstalltemperaturesensor

Installwireandgrounding

28

 

 

Installation blower assembly position For Model BD23 series

Installtemperaturesensor

Installwireandgrounding

Installblower

Installrockerswitch

29

Installation blower assembly position For Model # CRHSD25RT (Item # 0328253), and PCSD25RT.

Installation blower assembly position For Model # CRHFD400RT-M-M (Item # 0328248), and FBD400

Installwireandgrounding

Installwireandgrounding

Installgrounding

Installblower

Installblower

Installblower

Installtemperaturesensor Installtemperaturesensor

Installtemperaturesensor

Installrockerswitch

InstallrockerswitchInstallrockerswitch

30

ELECTRICAL CONNECTION

A15amp,120Volt,60Hzcircuitwithaproperlygroundedoutletisrequired.Preferably,thefireplacewillbeonadedicatedcircuitasotherappliancesonthesamecircuitmaycausethecircuitbreakertotriporthefusetoblowwhentheheaterisinoperation.Plantheinstallationtoavoidtheuseofanextensioncord.Extensioncordsarefortemporaryuseonly.Ifanextensioncordmustbeused,itmustbeUL/CSAcertified,ratedat10A(1250W),125Vmaximumwith16AWGminimumandconstructedoftwocurrentcarryingconductorswithground.Aheavydutyextensioncordwiththeshortestlengthpossiblefortheconnectionisrecommendedandmustnotbelongerthan50ft.(15.2m).Donotcoilorcovertheextensioncord.

Electricaloutletwiringmustcomplywithlocalbuildingcodesandotherapplicableregulationstoreducetheriskoffire,electricalshockandinjurytopersons.

Donotusethisfireplaceifanypartofithasbeenunderwater.Immediatelycallaqualifiedservicetechniciantoinspectthefireplaceandreplaceanypartoftheelectricalsystemwhichhasbeenunderwater.

GROUNDING INSTRUCTIONS

Thisheaterisforuseon120volts.ThecordhasaplugasshownatAinFig.36.AnadapterasshownatCisavailableforconnectingthree-bladegrounding-typeplugstotwo-slotreceptacles.Thegreengroundinglugextendingfromtheadaptermustbeconnectedtoapermanentgroundsuchasaproperlygroundedoutletbox.Theadaptershouldnotbeusedifathree-slotgroundedreceptacleisavailable.

Fig.36

OPERATING INSTRUCTIONS

Usingrockerswitch,turnbloweronandcheckforoperation.Turnonrockerswitchtothedesiredposition.IntheMANpositionitwillremainconstantlyon.AUTOpositionwillbecontrolledbythetemperaturesensor.TostoptheoperationturnrockerswitchtotheOposition.

GroundingPin

Adapter

GroundingMeans

MetalScrew

CoverofGroundedOutletBox

31

CARE AND MAINTENANCE

Always disconnect the appliance from the main power supply and allow it to cool before any servicing operation.Themotorsusedonthefanheaterandflameblowerarepre-lubricatedforextendedbearinglifeandrequirenofurtherlubrication.However,periodiccleaning/vacuumingoftheappliancearoundtheairintakeandexhaust,aswellasthefanheaterisrecommended.Forheavyorcontinuoususe,periodiccleaningmustbedonemorefrequently.Iftheheaterblowsalternatingcoldandwarmair,checkthefanforfreemovementandfordebrisrestrictingairflow.Ifthefandoesnotmovefreely,theunitmustbeturnedoffandthefanreplacedimmediatelyinordertopreventfurtherdamagetotheunit.

ELECTRICAL WIRING DIAGRAM

Anyelectricalre-wiringofthisappliancemustbedonebyaqualifiedelectrician.Thiswiringmustbedoneinaccordancewithlocalcodesand/orinCanadawiththecurrentCSAC22.1CanadianElectricalCode,andforUSinstallations,theNationalElectricalCodeANSI/NFPANO70.

Ifrepairingorreplacinganyelectricalcomponentorwiring,theoriginalwirerouting,colorcodingandsecuringlocationsmustbefollowed.

1.PowerCord2.BushingStrainRelief3.Fan4.TemperatureLimiter5.RockerSwitch

WHITE

GREEN BLACK

RED

FAN

BLA

CK

32

REPLACEMENT PARTS

NOTE:Useonlyoriginalreplacementparts.Thiswillprotectyourwarrantycoverageforpartsreplacedunderwarranty.

PARTS UNDER WARRANTYCallCustomerServicetollfreeat(1-877-886-5989)forreferralinformation.

WhencallingCustomerService,haveready:• Yourname• Youraddress• Modelandserialnumberofyourheater• Howheaterwasmalfunctioning• Typeofgasused(Propane/LPorNaturalgas/NG)• Purchasedate• Usually,wewillaskyoutoreturnthedefectiveparttothefactory

PARTS NOT UNDER WARRANTYCallCustomerServicetollfreeat(1-877-886-5989)forreferralinformation.

WhencallingCustomerServicehaveready:• Modelnumberofyourheater• Thereplacementpartnumber

33

REPLACEMENT PARTS LIST

Forreplacementparts,callourcustomerservicedepartmentat1-877-886-5989,8:00a.m-4:30p.m.,EST,[email protected].

PART PART NUMBER DESCRIPTION QuantityA XB001-01 PowerCord 1B XB002-01Q Blower 1C XB003-01 TemperatureSensor 1D XB004-01Q ConnectWire 1E PF06-0400-A RockerSwitch 1

A

C

B

D

E

34

WARRANTYINFORMATIONKeepThisWarranty

IMPORTANT:WeurgeyoutofillyourwarrantyregistrationcardwithinTEN(10)daysofdateofinstallation,completewiththeentireserialnumberwhichcanbefoundontheratingplate.Retainthisportionofthecardforyourrecord.Alwaysspecifymodelandserialnumberswhencommunicatingwithcustomerservice.Wereservetherighttoamendthesespecificationsatanytimewithoutnotice.Theonlywarrantyapplicableisourstandardwrittenwarranty.Wemakenootherwarranty,expressedorimplied.

LIMITED WARRANTY:PRO-COMwarrantsthisproducttobefreefromdefectsinmaterialsandcomponentsforTWO(2)yearsfromthedateoffirstpurchase,providedthattheproducthasbeenproperlyinstalled,operatedandmaintainedinaccordancewithallapplicableinstructions,tomakeaclaimunderthiswarranty,theBillofSaleorcancelledcheckmustbepresented.

RESPONSIBILITY OF OWNERThiswarrantyisextendedonlytotheoriginalretailpurchaser.Thiswarrantycoversthecostofpart(s)requiredtorestorethisheatertoproperoperatingconditionandanallowanceforlaborwhenprovidedbyaPRO-COMAuthorizedServiceCenter.Warrantypart(s)MUSTbeobtainedthroughauthorizeddealersofthisproductand/orPRO-COMwhowillprovideoriginalfactoryreplacementparts.Failuretouseoriginalfactoryreplacementpartsvoidsthiswarranty.TheheaterMUSTbeinstalledbyaqualifiedinstallerinaccordancewithalllocalcodesandinstructionsfurnishedwiththeunit.

WHAT IS NOT COVEREDThiswarrantydoesnotapplytopartsthatarenotinoriginalconditionbecauseofnormalwearandtearorpartsthatfailorbecomedamagedasaresultofmisuse,accidents,lackofpropermaintenanceordefectscausedbyimproperinstallation.Travel,diagnosticcost,labor,transportationandanyandallsuchothercostsrelatedtorepairingadefectiveheaterwillbetheresponsibilityoftheowner.TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT,THISEXPRESSWARRANTYEXCLUDESANYANDALLOTHEREXPRESSEDWARRANTIESANDLIMITSTHEDURATIONOFANYANDALLIMPLIEDWARRANTIES.INCLUDINGWARRANTIESOFMERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSETOTWO(2)YEARSONALLCOMPONENTSFROMTHEDATEOFFIRSTPURCHASE.PRO-COM'SLIABILITYISHEREBYLIMITEDTOTHEPURCHASEPRICEOFTHEPRODUCTANDPRO-COMSHALLNOTBELIABLEFORANYOTHERDAMAGESWHATSOEVERINCLUDINGINDIRECT.INCIDENTALORCONSEQUENTIALDAMAGES.Somestatesdonotallowalimitationonhowlonganimpliedwarrantylastsoranexclusionorlimitationofaccidentalorconsequentialdamages,theabovelimitationonimpliedwarranties,orexclusionorlimitationondamagesmaynotapplytoyou.Thiswarrantygivesyouspecificlegalright,andyoumayalsohaveotherrightsthatvaryfromstatetostate.

PrintedinChina