Issued October 18, 2017 Four (4) Pages + Revised Form of Tender (1pg)
+ Asbestos Report (27pgs) + Revised Drawings (4)
ADDENDUM NO. 1 Interior/Exterior Renovations at the Former Post Office Facility
Tender Number: T-62-2017
CLOSING TIME & DATE: 2:00 P.M., LOCAL TIME, FRIDAY, OCTOBER 20, 2017 CLOSING TIME & DATE: 2:00 P.M., LOCAL TIME, TUESDAY, OCTOBER 24, 2017
This addendum addresses and/or clarifies the following:
1. Revised Closing Date
Original Closing time & Date: 2:00 P.M., Local Time, Friday, October 20, 2017Revised Closing Time and Date: 2:00 P.M., LOCAL TIME, TUESDAY, OCTOBER 24, 2017
2. Revised Substantial Completion Date
Due to a Downtown Oakville function, road closures in the area surrounding the PostOffice will be in effect. Vehicle access to the Post Office will be severely restrictedfrom Thursday, November 23, 2017 to Sunday, November 26th. The Contractor isstrongly advised not to work on these days. An additional 4 calendar days will beadded to the contract.Substantial completion date is hereby revised to be: Monday, December 4, 2017.
3. Asbestos Report
Please find attached report titled ‘Asbestos Reassessment’ dated August 11, 2017 foryour information.
4. Cash Allowance
There is a $30,000 cash allowance associated with this Tender, this amount is to beincluded in the Total Bid Price. Please replace Form of Tender page 46 with theattached revised Form of Tender page 46.
For a complete list of all services, building components, testing, etc., that are coveredunder Cash Allowance, please refer to “Division 01 – General Requirements/01 10 00– General Instructions” found on page 115 of 1.24 in the Specifications. Add thefollowing to the cash allowance list under paragraph 1.24.1; “Tactile Walking SurfaceIndicators” and “Additional Metal Works”.
![Page 2: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/2.jpg)
5. Architectural Drawings
The following architectural drawings are hereby reissued and form an integral part of this addendum; A4 – Proposed Ground Floor Plan and Exterior Elevations A6 – Sections at Exterior Ramp and Stair A12 – Sections at Proposed Exterior Ramp and Details A13 – Handrail and Post Detail and Wall Mounted Handrail Detail The revisions to the architectural drawings include the addition of a galvanized steel guard at one side of the ramp and at the stair landing, the revision of the ramp slope to 1:20 and the location of the tactile walking surface indicators.
6. Questions and Responses Q1. Please advise if there are any mandatory contractors to carry during this tender,
including: controls, building life and safety contractors. R1. There are no mandatory contractors to carry on this project. There are no
controls, building life and safety contractors associated with this project. Q2. Is the project a union required site? R2. No. Q3. Is there a possibility for another site visit? R3. No. Q4. Is this a normal business hours project? R4. Interior work may take place 24hours/day, 7 days/week, at the discretion
and approval of the Town’s project manager. Exterior work will be limited to regular business hours with the possibility of extending working hours at the discretion and approval of the Town’s project manager. Note: the town will not pay extra for work performed outside of normal business hours beyond what is quoted in the Tender submission. Should the Contractor plan to work outside of normal business hours, those costs must be included in the lump sum tendered.
Q5. Our millwork supplier is looking for specification for the PL2 mentioned at
drawing# 7. R5. The specifications for the PL2 finish (plastic laminate) can be found in the
written specifications under Division 06 – Wood, Plastics and Composites starting on page 192 of 324.
Q6. As per finish schedule G101 is new flooring finishes. As per demolition plan we
should retain flooring at G101. R6. For Room G101 Existing Entry, disregard Note 27 and insert Note 8 in its’
place, anywhere Note 27 is found.
![Page 3: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/3.jpg)
Q7. Please confirm that the contractor will have to carry for parking costs and that
the public parking lot across the street is available for contractor use. R7. There is no free parking available for the contractor at this facility.
Contractor must carry all parking costs within their bid price. There is a public parking lot across the street and there is also a public parking lot at the rear of the Post Office.
Q8. Please confirm that the sidewalk must remain open during construction, and
therefore no permit will be required. R8. Yes, the sidewalk in front of the Post Office must remain open during
construction. Q9. Please confirm that the loading area in the back can be used to hoard material,
provided it is moved same-day. R9. Correct, there is an overhead door at the rear of the building that can be
used to load/unload equipment, materials, debris, etc. But it can only be used on a temporary basis.
Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area is no longer included in the scope of work. The
staging area shown on the tender drawings is not correct and should be disregarded as a part of this contract.
Q11. Please advise if cash allowance includes hardware and paint finish. R11. Door hardware is included in the Cash Allowance, painting is not. Refer
also to Item No. 2 of this addendum regarding Cash allowance. Q12. Please confirm post are to be of galv. steel and handrail stainless steel. R12. The handrail is brushed stainless steel and the post bars are galvanized
steel. Q13. On Drawing E-4, Notes (Number 3), what is the height from the G102 Existing
Customer Service Room to the ceiling space? R13. The height to underside of existing ceiling in G102 is 2910mm as noted on
architectural drawing A3. Q14. On Drawing E-4, Notes (Number 2), when it says "Provide a new fire alarm
strobe to match existing system and wire to existing fire alarm control panel." Which kind of wire is required there? Would it be #12? As mentioned in the electrical specifications towards the end of the document, it states that "The Minimum permissible size for branch circuit wiring shall be #12"
R14. The contractor is to determine which kind of wire to use based on all applicable codes for this work.
![Page 4: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/4.jpg)
Q15. Notes on A11,A5 & A3 all indicate existing ceiling panels to remain, however, A5 shows supply and install new ceiling panels. Please clarify.
R15. Existing suspended T-bar ceiling framing assembly and acoustic ceiling panels to remain. Contractor to protect ceiling assembly during construction.
Q16. The architectural drawings refer to the mechanical drawings - Can you please
provide the set of latest mechanical drawings? R16. There are no mechanical drawings for this project, just some minor
mechanical notes/references within the architectural drawings. Q17. Where would the staging area, equipment and storage bin areas be? As
mentioned in the meeting, the proposed mobilization area will not be available. R17. At the rear of the building close to the overhead doors. The Contractor is
responsible for coordinating and paying for (through the Town’s Municipal Enforcement department) any/all public parking spaces used during construction.
Q18. Are sidewalk permit required? If so who would be responsible for it? R18. Sidewalk permit (Right of way/encroachment Permit) is not required at
this time. However if the Contractor is more comfortable having one, it will be their responsibility to apply and pay for such permit.
Q19. Are sidewalk permit required? If so who would be responsible for it? R19. Sidewalk permit (Right of way/encroachment Permit) is not required at
this time. However if the Contractor is more comfortable having one, it will be their responsibility to apply and pay for such permit.
Q20. Power and water available on site? R20. Yes.
All other requirements regarding the tender remain the same. Be sure to acknowledge on the Form of Tender that this addendum has been incorporated or included in your submission. Derek White, CSCMP, CPPB Intermediate Buyer, Purchasing & Risk Management TOWN OF OAKVILLE
![Page 5: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/5.jpg)
SECTION C Form of Tender
BIDDER’S INITIALS_______
TO THE CORPORATION OF THE TOWN OF OAKVILLE hereinafter called the "Corporation"
TENDER FOR: Interior/Exterior Renovations at the Former Post Office Facility
TENDER No.: T-62-2017
_____________________________________________________ Name of Firm or Individual Submitting
_____________________________________________________ Address and Postal Code.
_____________________________________________________ Name and Position of Person Signing for Firm.
Phone Number: ______________________ Fax Number: _____________________
Contact Email: ___________________________________________________________
I/We, the undersigned, having carefully examined the site of the proposed work, and having read, understood, and accepted the Instructions to Bidders, Special Provisions and/or General Requirements, Specifications, Form of Tender, Agreement to Bond(s), Form of Agreement, Drawings and General Conditions, attached hereto, each and all of which form part of this tender, hereby offer to furnish all machinery, tools, labour, apparatus, and other means of construction; all materials, except as otherwise specified in the Contract; and to complete the work in strict accordance with the tender documents noted above and hereto attached for the lump sum price (excluding HST) of:
The cost of all labour, equipment, materials and pertinences to be incorporated in the work is:
A) LUMP SUM, BASE BID AMOUNT: $ _____________________
B) CONTINGENCY AMOUNT: $ 12,000
C) CASH ALLOWANCE AMOUNT: $ 30,000 (Refer to ‘1.24 CASH ALLOWANCES’ on pg. 115)
D) TOTAL BID (A + B + C): $ _____________________ (in CAD and excluding HST)
Addendum 1 - Revised
46 of 324
![Page 6: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/6.jpg)
© 2017 Pinchin Ltd.
Asbestos Reassessment Former Canada Post Building 193 Church Street, Oakville, Ontario Prepared for:
Town of Oakville 1225 Trafalgar Road Oakville, Ontario L6H 0H3
Attention: Gary Robinson Project Leader, Electrical Facilities and Construction Management
August 11, 2017
Pinchin File: 204783
![Page 7: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/7.jpg)
Asbestos Reassessment August 11, 2017 Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783 Town of Oakville
© 2017 Pinchin Ltd. Page ii
Issued to: Contact: Issued on: Pinchin File: Issuing Office: Primary Contact:
Town of Oakville Gary Robinson Project Leader, Electrical Facilities and Construction Management August 11, 2017 204783 2470 Milltower Court, Mississauga, ON L5N 7W5 Mark Stroombergen
Author: Owen Kirby, C.E.T., EPt Project Technologist 905.363.1376 [email protected]
Reviewer: Mark Stroombergen, C.E.T., EMBA Director, GTA - Hazardous Materials 905.363.1389 [email protected]
![Page 8: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/8.jpg)
Asbestos Reassessment August 11, 2017 Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783 Town of Oakville
© 2017 Pinchin Ltd. Page iii
EXECUTIVE SUMMARY
Town of Oakville (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials
reassessment of Former Canada Post Building located at 193 Church Street, Oakville, Ontario. The
reassessment was performed on June 19, 2017.
The objectives of the reassessment was to confirm the locations of asbestos building materials that were
previously identified, evaluate their condition and develop corrective action plans as required for the
purposes of long term management. The results of this reassessment are not intended for construction,
renovation, demolition or project tendering purposes.
The assessed area was limited to areas of the building with previously identified asbestos containing
materials. The building was vacant at the time of the reassessment work.
SUMMARY OF FINDINGS
Asbestos-containing materials (ACM) were confirmed to be present as follows:
Floor Location Description
Building System
Asbestos Material
Total Quantity Condition
Estimated Removal Cost
Remedial Work Required
Basement Corr. 1 Piping Magnesia Block 2 LF Poor $500 YES
Basement Room 6 Piping Parging Cement 1 fittings Poor $350 YES
Third Mechanical Room Piping Parging
Cement 25 fittings Good $2,500 No
Third Mechanical Room Piping Magnesia
Block 85 LF Good $1,500 No
Ground Loading M-10 Piping Parging Cement 2 fittings Good $500 No
Ground Loading M-10 Piping Magnesia Block 2 LF Good $500 No
Ground M-11 Floor Vinyl Floor Tiles 100 SF Good $500 No
Ground M-11 Wall Transite 60 SF Good $300 No
![Page 9: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/9.jpg)
Asbestos Reassessment August 11, 2017
Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783
Town of Oakville
© 2017 Pinchin Ltd. Page iv
Floor Location Description
Building System
Asbestos Material
Total Quantity Condition
Estimated Removal Cost
Remedial Work Required
Ground M-3, above ceiling tiles Piping Parging
Cement 2 fittings Good $200 No
Ground M-3, above ceiling tiles Piping Magnesia
Block 10 LF Good $500 No
Basement Elect. 1 Piping Parging Cement 7 fittings Good $700 No
Basement Elect. 1 Piping Magnesia Block 35 LF Good $950 No
Basement Vest. (South East) Piping Parging
Cement 8 fittings Good $800 No
Basement Vest. (South East) Piping Magnesia
Block 20 LF Good $800 No
Basement Corr. 1 Piping Parging Cement 8 fittings Good $800 No
Basement Corr. 1 Piping Magnesia Block 15 LF Good $750 No
Basement Corr. 1 Floor Vinyl Floor Tiles 650 SF Good $3,250 No
Basement Room 2 Piping Parging Cement
30 fittings Good $3,000 No
Basement Room 2 Piping Magnesia Block 100 LF Good $1,800 No
Basement Room 3 Piping Parging Cement
10 fittings Good $1,000 No
Basement Room 3 Piping Magnesia Block 70 LF Good $1,350 No
Basement Room 3 Floor Vinyl Floor Tiles 300 SF Good $1,500 No
Basement Room 4 Piping Parging Cement 9 fittings Good $900 No
Basement Room 4 Piping Magnesia Block 70 LF Good $1,350 No
![Page 10: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/10.jpg)
Asbestos Reassessment August 11, 2017
Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783
Town of Oakville
© 2017 Pinchin Ltd. Page v
Floor Location Description
Building System
Asbestos Material
Total Quantity Condition
Estimated Removal Cost
Remedial Work Required
Basement Room 5/5A Piping Parging Cement
41 fittings Good $4,100 No
Basement Room 5/5A Piping Magnesia Block 150 LF Good $2,700 No
Basement Room 5/5A Floor Vinyl Floor Tiles 600 SF Good $3,000 No
Basement Room 6 Piping Parging Cement
78 fittings Good $7,800 No
Basement Room 6 Piping Magnesia Block 315 LF Good $5,500 No
Basement Room 6 Floor Vinyl Floor Tiles 600 SF Good $3,000 No
Basement Room 7/8 Piping Parging Cement
10 fittings Good $1,000 No
Basement Room 7/8 Piping Magnesia Block 56 LF Good $1,200 No
Basement Room 7/8 Floor Vinyl Floor Tiles 400 SF Good $2,000 No
Basement Corr.2 Floor Vinyl Floor Tiles 650 SF Good $3,250 No
Basement 9/12, Boiler and Boiler Stores Piping Parging
Cement 91 fittings Good $9,100 No
Basement 9/12, Boiler and Boiler Stores Piping Magnesia
Block 410 LF Good $7,400 No
Basement Room 13 Piping Magnesia Block 40 LF Good $1,000 No
Basement Corr. 3 Piping Parging Cement
17 fittings Good $1,700 No
Basement Corr. 3 Piping Magnesia Block 110 LF Good $1,100 No
Basement Corr. 3 Floor Vinyl Floor Tiles 400 SF Good $2,000 No
![Page 11: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/11.jpg)
Asbestos Reassessment August 11, 2017
Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783
Town of Oakville
© 2017 Pinchin Ltd. Page vi
Floor Location Description
Building System
Asbestos Material
Total Quantity Condition
Estimated Removal Cost
Remedial Work Required
Basement Room 14 Piping Parging Cement
35 fittings Good $3,500 No
Basement Room 14 Piping Magnesia Block 400 LF Good $7,300 No
Basement Room 17 Piping Parging Cement
16 fittings Good $1,600 No
Basement Room 17 Piping Magnesia Block 100 LF Good $950 No
Basement Room 17 Floor Vinyl Floor Tiles 350 SF Good $1,750 No
Basement Room 18 Piping Parging Cement
24 fittings Good $2,400 No
Basement Room 18 Piping Magnesia Block 150 LF Good $2,700 No
Basement Room 18 Floor Vinyl Floor Tiles 450 SF Good $2,250 No
Basement Room 19 Piping Parging Cement
28 fittings Good $2,800 No
Basement Room 19 Piping Magnesia Block 175 LF Good $3,250 No
Basement Vest.(North East) Piping Parging
Cement 19 fittings Good $1,900 No
Basement Vest.(North East) Piping Magnesia
Block 55 LF Good $1,200 No
Basement Vest.(North East) Floor Vinyl Floor
Tiles 125 SF Good $625 No
Basement Room 20 Piping Parging Cement
22 fittings Good $2,200 No
Basement Room 20 Piping Magnesia Block 120 LF Good $2,200 No
Basement Room 20 Floor Vinyl Floor Tiles 1,800 SF Good $9,000 No
![Page 12: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/12.jpg)
Asbestos Reassessment August 11, 2017
Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783
Town of Oakville
© 2017 Pinchin Ltd. Page vii
Floor Location Description
Building System
Asbestos Material
Total Quantity Condition
Estimated Removal Cost
Remedial Work Required
Basement Room 21 Floor Vinyl Floor Tiles 750 SF Good $3,750 No
All Throughout Building
Walls and Ceilings
Drywall Joint Compound
28,000 SF Good $224,000 No
*Estimated removal costs are for removal and disposal of asbestos containing material only. Installation and replacement material is not included in the estimate. Some costs indicated above are based on the contractor performing multiple removals during a project and not a 1 off removal.
SUMMARY OF RECOMMENDATIONS
The following is a summary of significant recommendations; refer to the body of the report for detailed
recommendations:
1. Perform a reassessment of asbestos materials on an annual basis;
2. Perform a pre-construction assessment and remove all ACM prior to alteration or
maintenance work or if ACM may be disturbed by the work;
3. Follow appropriate safe work procedures when handling or disturbing asbestos;
4. Remove the damaged asbestos containing materials listed above. Refer to Section 4.0 of
this report for detailed recommendations regarding administrative and remedial actions.
This Executive Summary is subject to the same standard limitations as contained in the report and must be read in conjunction with the entire report.
![Page 13: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/13.jpg)
Asbestos Reassessment August 11, 2017 Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783 Town of Oakville
© 2017 Pinchin Ltd. Page viii
TABLE OF CONTENTS
1.0 INTRODUCTION AND SCOPE ....................................................................................................... 1
1.1 Scope of Reassessment ....................................................................................................... 1
2.0 BACKGROUND INFORMATION ..................................................................................................... 1
2.1 Building Description .............................................................................................................. 1 2.2 Existing Reports.................................................................................................................... 2
3.0 FINDINGS ........................................................................................................................................ 2
3.1 Suspect Building Materials Not Found ................................................................................. 2
4.0 RECOMMENDATIONS .................................................................................................................... 9
4.1 General ................................................................................................................................. 9 4.2 Remedial Work ..................................................................................................................... 9 4.3 On-going Management and Maintenance .......................................................................... 10
5.0 TERMS AND LIMITATIONS .......................................................................................................... 10
6.0 REFERENCES ............................................................................................................................... 11
APPENDICES
APPENDIX I Drawings
APPENDIX II Methodology
![Page 14: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/14.jpg)
Asbestos Reassessment August 11, 2017 Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783 Town of Oakville
© 2017 Pinchin Ltd. Page 1 of 11
1.0 INTRODUCTION AND SCOPE
Town of Oakville (Client) retained Pinchin Ltd. (Pinchin) to conduct an asbestos building materials
reassessment of Former Canada Post Building, located at 193 Church Street, Oakville, Ontario.
The reassessment was performed by Owen Kirby, C.E.T., EPt, Project Technologist on June 19, 2017.
The surveyor was unaccompanied during the reassessment. The building was vacant at the time of the
assessment.
The objectives of the reassessment was to confirm the locations of asbestos building materials that were
previously identified, evaluate their condition and develop corrective action plans as required for the
purposes of long term management. The results of this reassessment are not intended for construction,
renovation, demolition or project tendering purposes.
1.1 Scope of Reassessment
The reassessment was to confirm the locations of asbestos building materials that were previously
identified. The assessed area was limited to areas of the building with previously identified asbestos
containing materials.
2.0 BACKGROUND INFORMATION
2.1 Building Description
Item Details
Building Use Post Office and sorting facility
Number of Floors/Levels 3 stories plus 1 below grade
Total Area of Building (Square Feet) 13,830
Year of Construction, Significant Additions or Renovations
1958
Structure Structural steel, concrete
Exterior Cladding Pre-cast concrete
HVAC Rooftop AC, Boiler and hot water heating to radiators
Roof Built-up roofing
Flooring Vinyl tile, carpet, ceramic tiles, terrazzo
![Page 15: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/15.jpg)
Asbestos Reassessment August 11, 2017 Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783 Town of Oakville
© 2017 Pinchin Ltd. Page 2 of 11
Item Details
Interior Walls Drywall, concrete block, plaster
Ceilings Drywall, plaster, acoustic ceiling tiles
2.2 Existing Reports
Pinchin was provided with and instructed to rely upon, the following reports:
• Asbestos Reassessment Report, Former Canada Post Building. 193 Church Street,
Oakville, Ontario. August 2016, Pinchin File 115318
• Asbestos Reassessment Report, Former Canada Post Building. 193 Church Street,
Oakville, Ontario. July 2015, Pinchin File 105729
• ‘Reassessment Report of Asbestos-Containing Building Materials Former Canada Post
Building. 193 Church Street, Oakville Ontario.’ Maple Project Number 14251 dated July
2014
3.0 FINDINGS
3.1 Suspect Building Materials Not Found
The following types of building materials may historically contain asbestos but were not observed in the
building and are not discussed in the report findings:
• spray-applied fireproofing or thermal insulation;
• vinyl sheet flooring;
• firestopping;
3.1.1 Thermal Systems Insulation (TSI)
3.1.1.1 Pipe Insulation
Parging cement, containing chrysotile asbestos, is present on pipe fittings (elbows, valves, tees) on hot
water systems (previously sampled). Parging cement is a friable insulation, jacketed with canvas and is in
good condition, except for 3 fittings – see below for locations.
A white preformed block insulation (trade name Magnesia Block), containing chrysotile asbestos, is
present on straight sections of hot water system pipes (Previously sampled). Magnesia block is a friable
insulation, jacketed with canvas and is in good condition, except for 2 linear feet– see below for locations.
![Page 16: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/16.jpg)
Asbestos Reassessment August 11, 2017 Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783 Town of Oakville
© 2017 Pinchin Ltd. Page 3 of 11
Pipes insulated with friable asbestos insulations may be present in inaccessible spaces such as above
solid ceilings, in chases, in column enclosures and within shafts.
Asbestos-containing pipe insulations are present in the following location, quantity, and condition:
Type Location Sample Number Asbestos Type Total
Quantity Quantity Damaged
Parging Cement Third Floor Mechanical Room
Previously Sampled Chrysotile 25 fittings
N/A
Magnesia Block Third Floor Mechanical Room
Previously Sampled Chrysotile 85 LF
N/A
Parging Cement Loading M-10 Previously Sampled Chrysotile 2 fittings N/A
Magnesia Block Loading M-10 Previously Sampled Chrysotile 2 LF N/A
Parging Cement M-3, above ceiling tiles
Previously Sampled Chrysotile 2 fittings N/A
Magnesia Block M-3, above ceiling tiles
Previously Sampled Chrysotile 10 LF N/A
Parging Cement Elect. 1 Previously Sampled Chrysotile 7 fittings N/A
Magnesia Block Elect. 1 Previously Sampled Chrysotile 35 LF N/A
Parging Cement Vest. (South East)
Previously Sampled Chrysotile 8 fittings N/A
Magnesia Block Vest. (South East)
Previously Sampled Chrysotile 20 LF N/A
Parging Cement Corr. 1 Previously Sampled Chrysotile 8 fittings N/A
Magnesia Block Corr. 1 Previously Sampled Chrysotile 15 LF 2 LF
Parging Cement Room 2 Previously Sampled Chrysotile 30 fittings N/A
![Page 17: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/17.jpg)
Asbestos Reassessment August 11, 2017 Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783 Town of Oakville
© 2017 Pinchin Ltd. Page 4 of 11
Type Location Sample Number Asbestos Type Total
Quantity Quantity Damaged
Magnesia Block Room 2 Previously Sampled Chrysotile 100 LF N/A
Parging Cement Room 3 Previously Sampled Chrysotile 10 fittings N/A
Magnesia Block Room 3 Previously Sampled Chrysotile 70 LF N/A
Parging Cement Room 4 Previously Sampled Chrysotile 9 fittings N/A
Magnesia Block Room 4 Previously Sampled Chrysotile 70 LF N/A
Parging Cement Room 5/5A Previously Sampled Chrysotile 41 fittings N/A
Magnesia Block Room 5/5A Previously Sampled Chrysotile 150 LF N/A
Parging Cement Room 6 Previously Sampled Chrysotile 78 fittings 1 fittings
Magnesia Block Room 6 Previously Sampled Chrysotile 315 LF N/A
Parging Cement Room 7/8 Previously Sampled Chrysotile 10 fittings N/A
Magnesia Block Room 7/8 Previously Sampled Chrysotile 56 LF N/A
Parging Cement Room 9/12, Boiler and Boiler Stores
Previously Sampled Chrysotile 91 fittings
N/A
Magnesia Block Room 9/12, Boiler and Boiler Stores
Previously Sampled Chrysotile 410 LF
N/A
Magnesia Block Room 13 Previously Sampled Chrysotile 40 LF N/A
Parging Cement Corr. 3 Previously Sampled Chrysotile 17 fittings N/A
![Page 18: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/18.jpg)
Asbestos Reassessment August 11, 2017 Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783 Town of Oakville
© 2017 Pinchin Ltd. Page 5 of 11
Type Location Sample Number Asbestos Type Total
Quantity Quantity Damaged
Magnesia Block Corr. 3 Previously Sampled Chrysotile 110 LF N/A
Parging Cement Room 14 Previously Sampled Chrysotile 35 fittings N/A
Magnesia Block Room 14 Previously Sampled Chrysotile 400 LF N/A
Parging Cement Room 17 Previously Sampled Chrysotile 16 fittings N/A
Magnesia Block Room 17 Previously Sampled Chrysotile 100 LF N/A
Parging Cement Room 18 Previously Sampled Chrysotile 24 fittings N/A
Magnesia Block Room 18 Previously Sampled Chrysotile 150 LF N/A
Parging Cement Room 19 Previously Sampled Chrysotile 28 fittings N/A
Magnesia Block Room 19 Previously Sampled Chrysotile 175 LF N/A
Parging Cement Vest.(North East)
Previously Sampled Chrysotile 19 fittings N/A
Magnesia Block Vest.(North East)
Previously Sampled Chrysotile 55 LF N/A
Parging Cement Room 20 Previously Sampled Chrysotile 22 fittings N/A
Magnesia Block Room 20 Previously Sampled Chrysotile 120 LF N/A
![Page 19: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/19.jpg)
Asbestos Reassessment August 11, 2017 Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783 Town of Oakville
© 2017 Pinchin Ltd. Page 6 of 11
Photo 1
Asbestos containing parging cement on elbow fittings with Magnesia Block on straight sections of piping. Basement
Corridor 3.
3.1.1.2 Duct Insulation
Ducts are either uninsulated or insulated with non-asbestos fibreglass and jacketed with canvas.
3.1.1.3 Mechanical Equipment Insulation
Mechanical equipment is not insulated.
3.1.2 Acoustic Ceiling Tiles
All ceiling tiles are determined to be non-asbestos (previously sampled) or presumed to be non-asbestos
based on the date of manufacture determined from the date stamp applied to the top of the tiles or the
age of the materials determined from the age of the building or the renovation. The tiles were
manufactured after asbestos stopped being used in acoustic ceiling tiles.
3.1.3 Plaster
Plaster is present on walls and ceilings in the building. Plaster does not contain asbestos (previously
sampled).
3.1.4 Drywall Joint Compound
Drywall joint compound was found to contain chrysotile asbestos in at least one sample (previously
sampled). Assume all drywall joint compounds to be asbestos-containing unless further sampling proves
otherwise. There is 28,000 SF of drywall joint compound present and is in good condition. Drywall joint
compound is non-friable while in place, but can generate friable dust upon removal.
3.1.5 Asbestos Cement Products (Transite)
Transite board is present as panel in Room M-11. Transite is presumed to contain asbestos based on
visual observation. All transite is non-friable and in good condition.
![Page 20: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/20.jpg)
Asbestos Reassessment August 11, 2017 Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783 Town of Oakville
© 2017 Pinchin Ltd. Page 7 of 11
Photo 2
Transite board is present as panel in Room M-11
3.1.6 Vinyl Floor Tile and Mastic
Vinyl floor tiles are present as follows:
Size, Pattern, Colour and Photo Number Locations (Quantity) Sample
Number Asbestos Type (tile)
Asbestos Type (mastic)
9”x9” Cream with brown and white streaks. Photo 3
• Room 3 (300 SF)
• Room 5/5A (600 SF) Previously Sampled Chrysotile
None Detected
9”x9” White with green streaks. Photo 4
• Room 18 (450 SF)
• Room 20 (800 SF) Previously Sampled Chrysotile
None Detected
9”x9” White with lime green specks. Photo 5 • Corr. 3 (400 SF) Previously
Sampled Chrysotile None Detected
9”x9” Brown Photo. 6 • Room 17 (350 SF)
• Vest.(North East) (125 SF) Previously Sampled Chrysotile
None Detected
12”x12” Grey with white streaks. Photo 7
• Corr. 1 (650 SF)
• Room 6 (600 SF)
• Room 7/8 (400)
• Corr. 2 (650SF)
• Room 20 (1000 SF)
• Room 21 (750 SF)
Previously Sampled Chrysotile
None Detected
12”x12” Light beige with brown flecks. Photo 8
M-11 (100 SF) Previously Sampled Chrysotile None
Detected
The vinyl floor tiles and mastic are non-friable and are in good condition.
![Page 21: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/21.jpg)
Asbestos Reassessment August 11, 2017 Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783 Town of Oakville
© 2017 Pinchin Ltd. Page 8 of 11
Photo 3
Asbestos containing vinyl floor tile 9”x9” Cream with brown and white streaks
Photo 4
Asbestos containing vinyl floor tile 9”x9” White with green streaks.
Photo 5
Asbestos containing vinyl floor tile 9”x9” White with lime green specks.
Photo 6
Asbestos containing vinyl floor tile 9”x9” Brown
Photo 7
Asbestos containing vinyl floor tile12”x12” Grey with white streaks.
Photo 8
Asbestos containing vinyl floor tile 12”x12” Light beige with brown flecks.
![Page 22: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/22.jpg)
Asbestos Reassessment August 11, 2017 Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783 Town of Oakville
© 2017 Pinchin Ltd. Page 9 of 11
3.1.7 Presumed Asbestos Materials
A number of materials which might contain asbestos were not sampled during our reassessment due to
limitations in scope and methodology. Where present, these materials must be presumed to be an
asbestos material and are best sampled during project planning and preparation of contract documents
for their removal. Materials presumed to contain asbestos include:
• roofing, felts and tar;
• concrete floor levelling compound;
• elevator and lift brakes;
• vermiculite in concrete block wall cavities;
• caulking;
• mechanical packing, ropes and gaskets;
• fire resistant doors;
4.0 RECOMMENDATIONS
4.1 General
Perform a detailed intrusive assessment prior to building renovation or demolition operations. The
assessment should include destructive testing (i.e. coring and/or removal of building finishes and
components), and sampling of other hazardous materials (lead, mercury, PCBs, mould, etc.) and
materials not tested in this study (e.g. roofing materials, caulking, mastics).
4.2 Remedial Work
Perform the following remedial work to comply with existing regulations, due to the condition and location
of the material:
Material and Quantity Location Recommended Procedure
Pipe straight insulation, 2LF Basement, Corr.1 Glove-bag
Parging cement, 1 fittings Basement, Room 6 Glove-bag
![Page 23: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/23.jpg)
Asbestos Reassessment August 11, 2017 Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783 Town of Oakville
© 2017 Pinchin Ltd. Page 10 of 11
Photo 9
Damaged parging cement fitting, Basement, 6
Photo 10
Damaged pipe insulation, Basement, Corr.1
4.3 On-going Management and Maintenance
The following recommendations are made regarding on-going management and maintenance work
involving the asbestos materials identified.
4.3.1 Asbestos
Perform a reassessment of asbestos materials on an annual basis. The next re-assessment of ACM
should be performed prior to June 19th, 2018 to remain in compliance.
Remove all ACM prior to alteration or maintenance work or if ACM may be disturbed by the work. Follow
appropriate asbestos precautions for the classification of work being performed.
5.0 TERMS AND LIMITATIONS
This work was performed subject to the Terms and Limitations presented or referenced in the proposal for
this project.
Information provided by Pinchin is intended for Client use only. Pinchin will not provide results or
information to any party unless disclosure by Pinchin is required by law. Any use by a third party of
reports or documents authored by Pinchin or any reliance by a third party on or decisions made by a third
party based on the findings described in said documents, is the sole responsibility of such third parties.
Pinchin accepts no responsibility for damages suffered by any third party as a result of decisions made or
actions conducted. No other warranties are implied or expressed.
![Page 24: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/24.jpg)
Asbestos Reassessment August 11, 2017 Former Canada Post Building, 193 Church Street, Oakville, Ontario Pinchin File: 204783 Town of Oakville
© 2017 Pinchin Ltd. Page 11 of 11
6.0 REFERENCES
The following legislation and documents were referenced in completing the reassessment and this report:
1. Asbestos on Construction Projects and in Buildings and Repair Operations, Ontario
Regulation 278/05.
2. Designated Substances, Ontario Regulation 490/09.
J:\204000s\0204783.000 TOWNOFOAKVILL,VariousLocati,ASB,REASM\Deliverables\Canada Post Building\204783 Asbestos Reassessment Report Former Canada Post Building. 193 Church Street, Oakville, Ontario, Town of Oakville, August 2017.docx
Template: Master Report for Asbestos Assessment, Haz, July 21, 2017
![Page 25: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/25.jpg)
APPENDIX I Drawings
![Page 26: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/26.jpg)
ASBESTOS BULK SAMPLE
ASBESTOS-CONTAINING MATERIALS:
VINYL FLOOR TILE
MECHANICAL INSULATION
TRANSITE RAIN WATER LEADERS
NOT ALL KNOWN OR SUSPECTED
HAZARDOUS BUILDING MATERIALS MAY BE
DEPICTED ON THE DRAWING. REFER TO THE
HAZARDOUS BUILDING MATERIALS
ASSESSMENT REPORT FOR A COMPLETE
LIST OF KNOWN AND SUSPECTED
HAZARDOUS BUILDING MATERIALS.
LEGEND IS COLOUR DEPENDENT.
NON-COLOUR COPIES MAY ALTER
INTERPRETATION.
BASE PLAN PROVIDED BY CLIENT.
ACM MECHANICAL INSULATIONS ARE
SUSPECTED WITHIN WALL AND CEILING
CAVITIES THROUGHOUT THE BUILDING.
20
2
3
18
17
VEST.
8
5
5A
4
VESTIBULE
ELECT. 1
16
7
19
13
21
CORR. 3
CORR. 2
13536-5-02C
13536-5-02A
13536-5-02B
DATE:
DRAWN BY:
LOCATION:
CHECKED BY:
CLIENT:
PROJECT # :
DRAWING:
TITLE:
LEGEND:
SCALE:
NTS
THE TOWN OF OAKVILLE
CANADA POST
193 CHURCH STREET
OAKVILLE, ONTARIO
2017 ASBESTOS
REASSESSMENT
BASEMENT
2017/06/30
LM
OK
204783
1 OF 4
![Page 27: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/27.jpg)
M-13
M-12
ASBESTOS BULK SAMPLE
ASBESTOS-CONTAINING MATERIALS:
VINYL FLOOR TILE
MECHANICAL INSULATION
TRANSITE RAIN WATER LEADERS
NOT ALL KNOWN OR SUSPECTED
HAZARDOUS BUILDING MATERIALS MAY BE
DEPICTED ON THE DRAWING. REFER TO THE
HAZARDOUS BUILDING MATERIALS
ASSESSMENT REPORT FOR A COMPLETE
LIST OF KNOWN AND SUSPECTED
HAZARDOUS BUILDING MATERIALS.
LEGEND IS COLOUR DEPENDENT.
NON-COLOUR COPIES MAY ALTER
INTERPRETATION.
BASE PLAN PROVIDED BY CLIENT.
ACM MECHANICAL INSULATIONS ARE
SUSPECTED WITHIN WALL AND CEILING
CAVITIES THROUGHOUT THE BUILDING.
DATE:
DRAWN BY:
LOCATION:
CHECKED BY:
CLIENT:
PROJECT # :
DRAWING:
TITLE:
LEGEND:
SCALE:
NTS
THE TOWN OF OAKVILLE
CANADA POST
193 CHURCH STREET
OAKVILLE, ONTARIO
2017 ASBESTOS
REASSESSMENT
GROUND FLOOR
2017/06/30
LM
OK
204783
2 OF 4
![Page 28: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/28.jpg)
LADDER
ASBESTOS BULK SAMPLE
ASBESTOS-CONTAINING MATERIALS:
VINYL FLOOR TILE
MECHANICAL INSULATION
TRANSITE RAIN WATER LEADERS
NOT ALL KNOWN OR SUSPECTED
HAZARDOUS BUILDING MATERIALS MAY BE
DEPICTED ON THE DRAWING. REFER TO THE
HAZARDOUS BUILDING MATERIALS
ASSESSMENT REPORT FOR A COMPLETE
LIST OF KNOWN AND SUSPECTED
HAZARDOUS BUILDING MATERIALS.
LEGEND IS COLOUR DEPENDENT.
NON-COLOUR COPIES MAY ALTER
INTERPRETATION.
BASE PLAN PROVIDED BY CLIENT.
ACM MECHANICAL INSULATIONS ARE
SUSPECTED WITHIN WALL AND CEILING
CAVITIES THROUGHOUT THE BUILDING.
DATE:
DRAWN BY:
LOCATION:
CHECKED BY:
CLIENT:
PROJECT # :
DRAWING:
TITLE:
LEGEND:
SCALE:
NTS
THE TOWN OF OAKVILLE
CANADA POST
193 CHURCH STREET
OAKVILLE, ONTARIO
2017 ASBESTOS
REASSESSMENT
SECOND FLOOR
2017/06/30
LM
OK
204783
3 OF 4
![Page 29: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/29.jpg)
LADDER
ASBESTOS BULK SAMPLE
ASBESTOS-CONTAINING MATERIALS:
VINYL FLOOR TILE
MECHANICAL INSULATION
TRANSITE RAIN WATER LEADERS
NOT ALL KNOWN OR SUSPECTED
HAZARDOUS BUILDING MATERIALS MAY BE
DEPICTED ON THE DRAWING. REFER TO THE
HAZARDOUS BUILDING MATERIALS
ASSESSMENT REPORT FOR A COMPLETE
LIST OF KNOWN AND SUSPECTED
HAZARDOUS BUILDING MATERIALS.
LEGEND IS COLOUR DEPENDENT.
NON-COLOUR COPIES MAY ALTER
INTERPRETATION.
BASE PLAN PROVIDED BY CLIENT.
ACM MECHANICAL INSULATIONS ARE
SUSPECTED WITHIN WALL AND CEILING
CAVITIES THROUGHOUT THE BUILDING.
DATE:
DRAWN BY:
LOCATION:
CHECKED BY:
CLIENT:
PROJECT # :
DRAWING:
TITLE:
LEGEND:
SCALE:
NTS
THE TOWN OF OAKVILLE
CANADA POST
193 CHURCH STREET
OAKVILLE, ONTARIO
2017 ASBESTOS
REASSESSMENT
THIRD FLOOR
2017/06/30
LM
OK
204783
4 OF 4
![Page 30: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/30.jpg)
APPENDIX II Methodology
![Page 31: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/31.jpg)
Asbestos Re-Assessment Methodology August 11, 2017 Methodology Appendix Pinchin File: 204783
© 2017 Pinchin Ltd. Page 1 of 2
1.0 METHODOLOGY
Pinchin inspects the current condition of all accessible asbestos-containing materials (ACM) identified in
the most recent assessment. The surveyor makes reference to any existing assessment reports and
information provided by the Client regarding any newly identified ACM.
The re-assessment excludes the following:
• Articles belonging to the owner, tenant or occupant (e.g. stored items, furniture,
appliances, etc.);
• Underground materials or equipment (e.g. vessels, drums, underground storage tanks,
pipes, etc.);
• Building envelope, structural components, inaccessible or concealed materials or other
items where sampling may cause consequential damage to the property.
• Energized systems (e.g. internal boiler components, elevators, mechanical or electrical
components);
• Controlled products (e.g. stored chemicals, operational or process-related substances);
and
• Materials not typically associated with construction (e.g. settled dust, spills, residual
contamination from prior spills, etc.).
The reassessment is limited to non-intrusive testing. Concealed spaces such as those above solid
ceilings and within shafts and pipe-chases are accessed via existing access panels only. Pinchin Ltd.
does not conduct demolition of walls, solid ceilings, structural items, interior finishes or exterior building
finishes, to determine the presence of concealed materials.
2.0 ASBESTOS
Pinchin Ltd. conducts an inspection for the presence of friable and non-friable asbestos-containing
materials (ACM). A friable material is a material that when dry can be crumbled, pulverized or powdered
by hand pressure.
Asbestos materials are evaluated in order to make recommendations regarding remedial work. The
priority for remedial action is based on several factors:
• Friability (friable or non-friable);
• Condition (good, fair, poor, debris);
• Accessibility (ranking from accessible to all building users to inaccessible);
• Visibility (whether the material is obscured by other building components); and
![Page 32: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/32.jpg)
Asbestos Re-Assessment Methodology August 11, 2017 Methodology Appendix Pinchin File: 204783
© 2017 Pinchin Ltd. Page 2 of 2
• Efficiency of the work (for example, if damaged ACM is being removed in an area, it may
be most practical to remove all ACM in the area even if it is in good condition).
Master Template: Methodology Document for Asbestos Re-Assessment, HAZ, July 21, 2017
![Page 33: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/33.jpg)
MS
TH
FE
FP
SP
EP
PDO
PDO
PDO
PDO
TH
NEW RAMP
SLOPE 1:20
DN
2R
CR
DN
DN 2R
EXISTINGCUSTOMER SERVICE
A=41.85m2G102
EXISTINGENTRYG101
G101
G102A
G102B
A42A
TV - REFER TO
NOTE 9.
NEW SERVICE
COUNTER.
REFER TO
DRAWING 1/A7.
LO
W
HIG
H
ELECTRICAL CHASE IN
MILLWORK. PROVIDE DATA
AND POWER. REFER TO
ELECTRICAL DRAWINGS.
WALL MOUNTED STAINLESS
STEEL HANDRAIL. REFER
TO DETAIL 2/A13
LINE OF NEW WEEPING
TILE. REFER TO DETAIL
3/A12. CONNECT NEW
WEEPER TO EXISTING
WEEPING TILE AT EXISTING
BUILDING FOUNDATION
A42B
EJ CJ CJ
CJ
EJ
EJ
CJ
EJ
CJ
CJ
CJ
CONCRETE SIDEWALK.
REFER TO 3/A6
A42C A6
2A61
40mm DIAM. BRUSHED STAINLESS STEEL HANDRAILS ON
GALVANIZED DOUBLE BAR POSTS TYP. AT RAMP AND STAIR.
PROPERTY LINE
NEW
STAIR
600mm DEEP TACTILE
WALKING SURFACE
INDICATOR MAT FLUSH
WITH CONCRETE AT TOP
AND BOTTOM OF RAMP.
600mm DEEP TACTILE WALKING SURFACE
INDICATOR MAT FLUSH WITH CONCRETE AT
TOP OF STAIR.
A. FRONT ELEVATION
POURED CONCRETE
FOUNDATION WALL & FOOTING.
REFER TO STRUCTURAL
B. SIDE ELEVATION
POURED CONCRETE
FOUNDATION WALL & FOOTING.
REFER TO STRUCTURAL
C. SECTION ELEVATION
WALL MOUNTED STAINLESS
STEEL HANDRAIL. REFER
TO DETAIL 2/A13
EACH POST IS 2-12X50
GALVANIZED STEEL
POST BARS FASTENED
TO EITHER SIDE OF
BRACKET WITH HEX
SOCKET CAP BOLTS.
REFER TO 1/A13
40mm DIAM. BRUSHED
S. ST. HANDRAIL
1100mm HIGHT GUARD WITH GALVANIZED
STEEL POST BAR PICKETS TYP. AT RAMP
AND STAIR. REFER TO 1/A13.
no. issue/revision date
drawing
project
POST OFFICE BUILDING - INTERIOR RENOVATIONS
AND EXTERIOR UPGRADES
CORPORATION OF THE TOWN OF OAKVILLE
193 Church Street, Oakville ON
ward99 project number
17014 - OAKVILLE
drawing scaleNORTH
drawing no.
1. ISSUED FOR TENDER
2053 williams parkway unit 49A
brampton ontario L6S 5T4
416 613 5880 www.ward99architects.com
ward99
architects
Wa
RD99
2. ISSUED FOR PERMIT
11/09/201711/09/2017
1 PROPOSED GROUND FLOOR PLAN
A4 1:100
PROPOSED GROUND FLOOR PLAN AND
EXTERIOR ELEVATIONS
A4
GENERAL LOWER LEVEL AND GROUND
FLOOR PLAN NOTES
1. PROPOSED DRAWINGS ON A4 SHALL BE READ IN CONJUNCTION WITH
DEMOLITION DRAWING A2 AND ALL OTHER ARCHITECTURAL
DRAWINGS, STRUCTURAL AND ELECTRICAL DRAWINGS
FOR ADDITIONAL INFORMATION, DETAILS, NOTES AND DIMENSIONS.
2. GXX REFERS TO DOOR NUMBER. REFER TO A9 FOR DOOR
SCHEDULE AND DOOR DETAILS AND DRAWING A10 FOR DOOR
AND FRAME ELEVATIONS, TYPES AND DETAILS.
3. REFER TO DRAWING A11 FOR ROOM FINISH PLAN, ROOM FINISH
SCHEDULE AND NOTES.
4. DETAIL TAG: DETAIL NUMBER/DRAWING NUMBER.
5. ELEVATION TAG: ELEVATION DETAIL NUMBER/DRAWING NUMBER.
6. ROOM TITLE:
7. SECTION TAG: SECTION DETAIL NUMBER/DRAWING
NUMBER
8. PDO = EXISTING POWER DOOR OPERATOR TO REMAIN. CONNECT
EXISTING PDO TO NEW DOORS.
FP = EXISTING FIRE PULL TO REMAIN.
MS = EXISTING MOTION SENSOR TO REMAIN.
SP = EXISTING SECURITY PANEL TO REMAIN. CONNECT NEW DOORS TO
EXISTING SECURITY PANEL. THIS WORK IS CARRIED IN THE CASH
ALLOWANCE.
CR = NEW CARD READER AT NEW ENTRY DOORS. WORK IS CARRIED IN
THE CASH ALLOWANCE.
TH = EXISTING THERMOSTAT TO REMAIN.
REFER TO ELECTRICAL DRAWINGS REGARDING THE ABOVE.
9. NEW TV TO BE SUPPLIED BY THE OWNER AND INSTALLED BY THE
GENERAL CONTRACTOR. SIZE OF TV SCREEN TO BE CONFIRMED.
SUPPLY AND INSTALL A 19mm THICK PLYWOOD PANEL (610mm X 610mm)
ON THE EXISTING GYPSUM BOARD FINISHED WALL TO PROVIDE SUPPORT
FOR THE NEW TV SCREEN. PAINT EXISTING PLYWOOD PANEL TO MATCH
EXISTING WALL.
10. EJ = EXPANSION JOINT AT NEW CONCRETE WALKWAY/ SIDEWALK.
PROVIDE AT MINIMUM 4500mm O.C. WITH PREMOLDED JOINT FILLER.
CJ = CONTROL JOINT/TOOLED JOINT AT NEW CONCRETE WALKWAY/
SIDEWALK. PROVIDE CJ AT MINIMUM 1500mm O.C.
* AT BOTH EJ AND CJ, PROVIDE 100mm WIDE CONTINUOUS SMOOTH
FINISHED BANDS AT FULL EXTENT OF CJ AND EJ. REFER TO 3/A6.
x
Ax
G1XXROOM
xAx
ROOM NAME
ROOM NUMBER
ROOM AREA
OCCUPANT LOAD
xAx
A = X m2
OL = Xp
2 PROPOSED EXTERIOR ELEVATIONS
A4 1:100
AS NOTED
NOTES:
1- PROVIDE PARGING AND BITUMINOUS DAMPPROOFING AT EXISTING
FOUNDATION WALLS WHERE EXISTING WALLS ARE EXPOSED AT DEMOLISHED
CONCRETE WALKWAYS/SIDEWALKS.
2- PROVIDE WATERPROOFING MEMBRANE AND DRAINAGE MEMBRANE AT
FULL EXTENT OF NEW CONCRETE FOUNDATIONS WALLS AND FOOTINGS. LAP
ONTO EXISTING FOUNDATION WALLS.
3- PROVIDE NEW CONTINUOUS WEEPING TILE AT NEW CONCRETE FOOTING
PERIMETER TO CONNECT TO EXISTING WEEPING TILE AT EXISTING BUILDING.
3. ISSUED FOR
ADDENDUM NO.1
18/10/2017
3
3
3
![Page 34: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/34.jpg)
SUB BASE COURSE
BASE COURSE
TERMINATE MESH EACH SIDE OF JOINT
CONCRETE SIDEWALK/WALKWAY: 125mm THICK, 32
MPA IN STRENGTH AND 5% TO 7% AIR ENTRAINMENT.
15x600mm SMOOTH DOWEL, GREASED ONE END @ 400 o/c
63mm DEEP SAWCUT, CAULKED @ 1200 o/c
WELDED WIRE MESH REINFORCING
TOOLED JOINTS WITH SLIGHTLY ROUNDED EDGES
TYPICAL CONCRETE SIDEWALK ON GRANULAR BASE
12mm JOINT FILLER SET 12mm BELOW TOP OF SLAB,
CAULKED TYPICAL, @3000 o/c
EXPANSION JOINT CONC. JOINT
FOOTING BEYOND. REFER TO STRUCTURAL
POURED CONCRETE FOUNDATION WALL
& FOOTING. REFER TO STRUCTURAL
POURED CONCRETE RAMP &
CURB. REFER TO STRUCTURAL
POURED CONCRETE SLAB ON
GRADE. REFER TO STRUCTURAL
POURED CONCRETE SIDEWALK.
REFER TO DETAIL 3/A6
CONTROL JOINT AT PERIMETER
OF EXISTING WALL
1:2
0 S
LO
PE
50mm RIGID INSULATION
COMPACTED GRANULAR BACKFILL
WEEPING TILE C/W CRUSHED
GRANULAR FILL
WATERPROOFING FROM TOP OF NEW
FOUNDATION WALL TO FOOTING COVE.
LAP ONTO NEW PARGING AT EXISTING
BUILDING FOUNDATION WALLS.
DAMPPROOFING FROM FINISHED
GRADE TO BOTTOM OF FOOTING
A62
A121
A123
40mm DIAMETER BRUSHED STAINLESS STEEL
HANDRAIL TYP. AT NEW RAMP AND STAIR.
GUARD: GALVANIZED STEEL POSTS (2-12X50
GALVANIZED STEEL POST BARS FASTENED TO
EITHER SIDE OF BRACKET WITH HEX SOCKET
CAP BOLTS) WITH 12X50 GALVANIZED STEEL
POST PICKETS BETWEEN POSTS TYP. PROVIDE
12X50 CONTINUOUS GALVANIZED TOP BAR AND
BOTTOM TYP. REFER TO 1/A13.
POURED CONCRETE
FOUNDATION WALL &
FOOTING. REFER TO
STRUCTURAL
EXISTING WINDOW TO REMAIN
jh jh
NEW ANODIZED ALUMINUM
DOOR & FRAME
FOOTING BEYOND.
REFER TO
STRUCTURAL
POURED CONCRETE
SLAB ON GRADE &
STAIRS. BROOM
FINISH. REFER TO
STRUCTURAL
POURED CONCRETE
SIDEWALK. REFER TO
DETAIL 3/A6
EXISTING
FOUNDATION
WALL TO REMAIN
EXISTING CONCRETE
SIDEWALK TO REMAIN
CONTROL
JOINT
CONTROL
JOINT AT
PERIMETER
OF EXISTING
WALL
50mm RIGID INSULATION
COMPACTED
GRANULAR BACKFILL
PERIMETER
WEEPERS WITH
GRANULAR
COVER & FILTER
FABRIC (TYP.)
WATERPROORING
FROM TOP OF
FOUNDATION
WALL TO FOOTING
COVE PARGING
AT FOOTING
A61
2%
SLOPE
A122
A123
2-12X50 GALVANIZED STEEL
POSTS FASTENED TO EITHER
SIDE OF BRACKET WITH HEX
SOCKET CAP BOLTS. REFER
TO 1/A13
40mm DIAM. BRUSHED
S. ST. HANDRAIL
no. issue/revision date
drawing
project
POST OFFICE BUILDING - INTERIOR RENOVATIONS
AND EXTERIOR UPGRADES
CORPORATION OF THE TOWN OF OAKVILLE
193 Church Street, Oakville ON
ward99 project number
17014 - OAKVILLE
drawing scaleNORTH
drawing no.
1. ISSUED FOR TENDER
2053 williams parkway unit 49A
brampton ontario L6S 5T4
416 613 5880 www.ward99architects.com
ward99
architects
Wa
RD99
2. ISSUED FOR PERMIT
11/09/201711/09/2017
SECTIONS AT PROPOSED EXTERIOR
RAMP AND STAIR
A6
1 SECTION AT PROPOSED EXTERIOR RAMP & STAIR
A6 1:50
1:50
2 SECTION AT PROPOSED EXT. STAIR
A6 1:50
3 TYPICAL EXPANSION JOINT & CONTROL JOINT DETAIL AT SIDEWALK
A6 1:20
3. ISSUED FOR
ADDENDUM NO.1
18/10/2017
3
![Page 35: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/35.jpg)
POURED CONCRETE
FOUNDATION WALL &
FOOTING. REFER TO
STRUCTURAL
EXISTING WINDOW TO REMAIN
FOOTING BEYOND.
REFER TO
STRUCTURAL
POURED CONCRETE
SLAB ON GRADE
RAMP. BROOM
FINISH. REFER TO
STRUCTURAL
POURED CONCRETE
SIDEWALK. REFER TO
DETAIL 3/A6
EXISTING
FOUNDATION
WALL TO REMAIN
EXISTING CONCRETE
SIDEWALK TO REMAIN
CONTROL JOINT
CONTROL JOINT AT
PERIMETER OF
EXISTING WALL
50mm RIGID INSULATION
COMPACTED
GRANULAR BACKFILL
PERIMETER WEEPERS
WITH GRANULAR COVER
& FILTER FABRIC (TYP.)
DRAINAGE MEMBRANE
ON WATERPROOFING
MEMBRANE FOR FULL
EXTENT OF FOUNDATION
AND FOOTINGS.
A61
A123
CHAMFERED EDGE
GUARD: GALVANIZED STEEL POSTS
(2-12X50 GALVANIZED STEEL POST BARS
FASTENED TO EITHER SIDE OF BRACKET
WITH HEX SOCKET CAP BOLTS) WITH
12X50 GALVANIZED STEEL POST PICKETS
BETWEEN POSTS TYP. PROVIDE 12X50
CONTINUOUS GALVANIZED TOP BAR AND
BOTTOM TYP. REFER TO 1/A13.
40mm DIAMETER
STAINLESS STEEL
HANDRAIL TYP. AT
RAMP AND STAIR.
COMPOSITE DRAINAGE
MEMBRANE ON TOP OF
WATERPROOFING
MEMBRANE FROM TOP
OF FOUNDATION WALL
AROUND FOOTING
POURED CONCRETE
FOUNDATION WALL &
FOOTING. REFER TO
STRUCTURAL
50mm RIGID PERIMETER
INSULATION TO 2260mm
BELOW FINISHED GRADE
48 O.D. STEEL DOUBLE VERTICAL POSTS
@ 1000 mm O.C. MAX. REFER TO 1/A13
POURED CONCRETE SIDEWALK.
REFER TO DETAIL 3/A6
PARTING STRIP WITH PRE-MOLDED
JOINT FILLER
POURED CONCRETE STAIRS.
BROOM FINISH. REFER TO
STRUCTURAL
CAST-IN NON SLIP STRIPS
-TWO PER TREAD - TYP.
PERIMETER WEEPERS WITH
GRANULAR COVER & FILTER
FABRIC (TYP.)
WATERPROOFING MEMBRANE FROM TOP OF
FOUNDATION WALL TO FOOTING COVE
PARGING AT FOOTING. PROVIDE
PREFINISHED COMPOSITE DRAINAGE
MEMBRANE ON TOP OF WATERPROOFING
MEMBRANE FOR FULL EXTENT OF
WATERPROOFING MEMBRANE.
LAP WATERPROOFING MEMBRANE
ONTO EXISTING BUILDING FOUNDATION
WALLS. PARGE AND PROVIDE NEW
DAMPPROOFING AT EXISTING BUILDING
FOUNDATIONS WALLS UNDER LAPPED
WATERPROOFING MEMBRANE. LAP
MEMBRANCE FROM FINISHED GRADE TO
BOTTOM OF FOOTING
REFER TO STRUCTURAL DRAWINGS FOR
SIZE OF CONCRETE FOOTING
POURED CONCRETE FOUNDATION WALL
& FOOTING. REFER TO STRUCTURAL
50mm RIGID PERIMETER INSULATION
TO 2260mm BELOW FINISHED GRADE
no. issue/revision date
drawing
project
POST OFFICE BUILDING - INTERIOR RENOVATIONS
AND EXTERIOR UPGRADES
CORPORATION OF THE TOWN OF OAKVILLE
193 Church Street, Oakville ON
ward99 project number
17014 - OAKVILLE
drawing scaleNORTH
drawing no.
1. ISSUED FOR TENDER
2053 williams parkway unit 49A
brampton ontario L6S 5T4
416 613 5880 www.ward99architects.com
ward99
architects
Wa
RD99
2. ISSUED FOR PERMIT
11/09/201711/09/2017
SECTIONS AT PROPOSED EXTERIOR
RAMP AND DETAILS
A12
1 SECTION AT PROPOSED EXTERIOR RAMP
A12 1:50
AS NOTED
2 DETAIL AT STAIR & SIDEWALK
A12 1:5
3 WEEPING TILE AT FOUNDATION
A12 1:10
3
3. ISSUED FOR
ADDENDUM NO.1
18/10/2017
![Page 36: Issued October 18, 2017 Four (4) Pages + Revised Form of ... · Q10. Please confirm that the staging area is no longer included in the scope of work. R10. Correct, the staging area](https://reader034.vdocuments.us/reader034/viewer/2022042314/5f026f007e708231d4043e61/html5/thumbnails/36.jpg)
no. issue/revision date
drawing
project
POST OFFICE BUILDING - INTERIOR RENOVATIONS
AND EXTERIOR UPGRADES
CORPORATION OF THE TOWN OF OAKVILLE
193 Church Street, Oakville ON
ward99 project number
17014 - OAKVILLE
drawing scaleNORTH
drawing no.
1. ISSUED FOR TENDER
2053 williams parkway unit 49A
brampton ontario L6S 5T4
416 613 5880 www.ward99architects.com
ward99
architects
Wa
RD99
2. ISSUED FOR PERMIT
11/09/201711/09/2017
HANDRAIL AND POST DETAIL AND WALL
MOUNTED HANDRAIL DETAIL
A13
1 SECTION AT PROPOSED GUARDRAIL
A13 1:5
AS NOTED
2 WALL MOUNTED HANDRAIL DETAIL
A13 1:5
3. ISSUED FOR
ADDENDUM NO.1
18/10/2017
3