Arden Presentation April 2013 1
Introduction to
Arden Photonics
David Robinson
Managing Director
Arden Presentation April 2013 2
Arden Presentation April 2013 3
About Arden
• Established in October 2001
• Based in Solihull, Birmingham
• We make and sell instruments for optical
fiber, laser and optics manufacturers
Arden Presentation April 2013 4
Customers
Arden Presentation April 2013 5
Customer support
San Francisco
Philadephia
Munich
Tokyo
Birmingham
Arden Presentation April 2013 6
Customer support
Arden Presentation April 2013 7
VFI series
Fiber cleave check
Arden Presentation April 2013 8
VFI series
Fiber cleave check
Arden Presentation April 2013 9
VFI series
Fiber cleave check
Arden Presentation April 2013 10
BQM series
Laser Beam profilers
Arden Presentation April 2013 11
Other products -
Custom Fiber Boxes
Arden Presentation April 2013 12
Encircled Flux
EF is the percentage of power within a given fiber core radius when
light is launched by a transmitter into a multimode fibre.
Arden Presentation April 2013 13
Why does it matter?
MMF
APPLICATION
SUPPORTED
CHANNEL
LENGTHS
REQUIRED
CHANNEL INSERTION
LOSS
10BASE-F 1514 - 2000 metres 6.8 - 12.5 dB
100BASE-F 2000 metres 11.0 dB
1000BASE-S 275 - 500 metres 2.6 - 3.6 dB
10GBASE-S 32 - 500 metres 1.6 - 2.6 dB
40/100GBASE-S 100 - 150 metres 1.5 - 1.9 dB
• reduction in maximum CIL
• reduction in typical channel length
• increased risk of litigation
• need for accuracy
• need for repeatability
As data rates increase using multimode optical
fibre
Insertion loss measurements need to be more
accurate and comparable now.
Arden Presentation April 2013 14
Why does it matter?
• Insertion Loss in multimode fiber is a
function of Modal Launch Conditions
• Insertion Loss measurements taken
with “underfilled” launch conditions can
lead to optimistic results.
Arden Presentation April 2013 15
Why does it matter?
Loss of 11 concatenated 50um patchcords at 850nm
0
1
2
3
4
5
6
singlemode
launch
VCSEL
laser
comms
tester
mode-
scrambler
sm offset
launch
loss, d
B
with modcon
without modcon
Arden Presentation April 2013 16
Modal Explorer Launch Condition Analyser
Arden Presentation April 2013 17
• Measures Encircled Flux – which is the industry’s chosen metric for Modal Launch Condition / Modal Filling in multimode fibers.
• Real time measurement
• 850 and 1300nm
• Standards compliant
Modal Explorer Launch Condition Analyser
Arden Presentation April 2013 18
EF measurement
example
Arden Presentation April 2013 19
Encircled Flux
Standards relating to the measurement of Encircled Flux
TIA/EIA-455-203 - Launched Power Distribution Measurement
Procedure for Graded- Index Multimode Fiber Transmitters
IEC 61280-1-4 - Fiber optic communication subsystem test
procedures - Part 1-4: General communication subsystems -
Collection and reduction of two-dimensional nearfield data for
multimode fibre laser transmitters
Arden Presentation April 2013 20
Encircled Flux
Standards relating to the measurement of optical fiber
cables and components
TIA-526-14-A - OFSTP-14 Optical Power Loss Measurement of
Installed Multimode Fiber Cable Plant.
IEC 61280-4-1 - Fiber-optic communication subsystem basic test
procedures - Part 4-1: Test procedures for fiber-optic cable plant and
links - Multimode fiber-optic cable plant attenuation measurement
Arden Presentation April 2013 21
ModCon
Mode controller
Arden Presentation April 2013 22
ModCon
Mode controller
• Produces standards compliant launch condition from any light source
• 50/125 µm or 62.5/125 µm
• Works at 850 and 1300nm
• Conforms to IEC 61280-4-1 / OFSTP-14
• Reference grade connector on output
Arden Presentation April 2013 23
Conclusions
1. Measurement and Control of Modal Launch Conditions – Arden’s specialization
2. All hardware and software design, build and support taken care of “in-house”.
3. You will be supported by engineers who use equipment daily
4. You can have solutions tailored to your requirements