interactive pollutant mapping powered by smw, franz borrmann, alexander gesinn, smwcon fall 2014

19
Interactive Pollutant Mapping Powered by SMW – Part 1 Franz Borrmann Alexander Gesinn

Upload: kdz-zentrum-fuer-verwaltungsforschung

Post on 02-Jul-2015

150 views

Category:

Software


0 download

DESCRIPTION

In many countries, the remediation of in-house pollutants such as PCB and asbestos has come into the focus. We want to show how SMW powered pollutant register and mapping can be used to document measurements, direct remedial actions and inform stakeholders.

TRANSCRIPT

Page 1: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Interactive Pollutant MappingPowered by SMW – Part 1

Franz Borrmann

Alexander Gesinn

Page 2: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Our Fields of Work

Radiation Protection Hazardous Substances Clean-up after Fires

Industrial HygieneProcess & Knowledge

ManagementWork Safety

Page 3: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Overview

• Setting the Scene

• Regulatory Requirements

• Current Solutions

• Our Aims

• Ontology Development

• Features

• Technical Details – Part 2

Page 4: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Setting the Scene

• Indoor pollution is resulting from buildingmaterials– Asbestos used as fire proof insulation

– Polychlorinated Biphenyls (PCB) used in elasticseals, mainly between concrete parts

– Polyarmatic Hydrocarbons (PAH) used in adhesives and elastic seals in floors

– Pesticides (i.a. HCH) used as wood protectives

Page 5: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Example PCB

• Chlorinated hydrocarbons

• Group of 211 congeners

• Used in elastic material

• Used in many prefabricated concretebuildings, mainly in seals

• Fire resistant, very stable

• Widely applicated in the 1960s till 1980s

Page 6: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Examples

RICHTLINIE PCB-haltige Fugendichtungsmassen Bundesamt für Umwelt, Wald und Landschaft BUWAL Bern, 2003Die sachgemässe Entfernung und Entsorgung PCB-haltiger Fugendichtungsmassen und Anstriche; Werkzeuge, Verfahren, Schutzmassnahmen Amt für Umweltschutz und Energie Fachstelle Stoffe und Chemikalien Liesthal

Page 7: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Toxicology

• Neuro-patholotical effects

• Oxidative stress by degradation products

• Contain dioxins and furans due to synthesisbyproducts these are ultimative cancerinducing substances

Page 8: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Metabolism

Harald Esch, Uni Würzburg: Toxikologie von polychlorierten Biphenylen (PCB)in der Atemluft, Vortrag an der Uni Bochum, 21.02.2014

Page 9: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Regulations

• Usage in open systems banned in 1973

• Production banned in 1993, small amounts(condensors) allowed until 2010

• Part of the Rotterdam Convention(„The dirty dozen“)

• Rubble < 50 mg/kg

• PCB directives on state- but not on federallevel, slight differences from state to state

Page 10: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Regulatory Limits

<300 µg/m³ (approx 10% tolerable daily intake TDI)

No Adverse Effect Level

300-3000 µg/m³Observation Level

Source Removal, if AppropriateAir Management

3000 µg/m³ (approx TDI within 24 h)

Immediate Action Required

Page 11: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Current solutions

• Excel Sheets

• Access Databases

• Usually static reports to stakeholders

• Static Webpages

Page 12: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Ontology Development

Page 13: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Map of Site

Page 14: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Map of Floor with Measured Values

Page 15: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Latest Measurements Display

Page 16: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Definition of Measuring Values and Limits

Page 17: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Background information on substance

Page 18: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Summary

• Approach for displaying any semantic dataon related to images (i.a. floor plan etc)

• Display filtered to current values

• Correct display of– Measurands

– Measurement units

– Measured values

– Limit values

Page 19: Interactive Pollutant Mapping Powered by SMW, Franz Borrmann, Alexander Gesinn, SMWCon Fall 2014

Room for improvement

• Color definition of image annotation bysemantic properties

• Integration of IFC/CAD-import for buildingdata

• Enhancement of Navigation