intellinox demand control kitchen...

21
INTELLINOX DEMAND CONTROL KITCHEN VENTILATION

Upload: others

Post on 15-Aug-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

INTELLINOX DEMAND CONTROL KITCHEN VENTILATION

Page 2: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

COMMERCIAL KITCHEN VENTILATION EXPERTS

FOR OVER 25 YEARS

Page 3: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

• WE REALLY UNDERSTAND YOUR KITCHENExtensive knowledge with all kitchen hood manufacturers including design, installation, and sales of hood systems.

• WE KNOW ENERGY EFFICIENCYThe Intellinox commercial kitchen ventilation controls save energy, operational costs, and help contribute to a greener environment.

• WE REALLY UNDERSTAND AIR FLOW IN YOUR KITCHENNEBB certified testing, adjusting, and balancing firm –with a specialty in commercial kitchens.

WHO WE ARE

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

Page 4: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

ALL OR NOTHING VENTILATION

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

EXHAUST & MAKE-UP AIR

Page 5: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

• Addition of new components mean a solution for every commercial kitchen

• Multiple cooking modes yield lower average fan speeds

• Improved sensor durability & maintenance

• Lower cost on materials and installation

• Automatic on & off feature allows for greater energy savings

WHAT’S NEW WITH INTELLINOX?

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

Page 6: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

• Senses temperature changes in the hood & ductwork

• Used for both cooking & auto on / off capability

• Programmable temperature spans

• Ease of installation in hood ductwork or top of hood

• Available in both standard and EMT model

KEY COMPONENTS: TEMPERATURE SENSOR

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

Page 7: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

• Iris Blue Optical Sensors

• Sensing smoke & steam in the hood

• Blue Light is able to detect smaller smoke & steam particles

• Available in both standard & EMT model

• Ease of installation

• Auto calibration

• Ease of cleaning & responsiveness

KEY COMPONENTS: OPTIC SENSOR

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

Page 8: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

• Retrofitted into pre-existing ductwork

• Adjustable to fit existing conditions

• Fully-closed to fully-open in under 4 seconds

• Access panel installed when needed

• Responsible for additional energy savings

• Option on Intellinox-PLUS

KEY COMPONENTS: MODULATING DAMPER

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

Page 9: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

• YASKAWA Z1000with bypass

• YASKAWAwithout bypass

• ANY VFD MANUFACTURER WILL BE COMPATIBLE

VARIABLE FREQUENCY DRIVE (VFD) OPTIONS

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

Page 10: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

PUTTING IT ALL TOGETHER

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

Page 11: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

PUTTING IT ALL TOGETHER

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

Page 12: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

• Temperature sensors, Optic sensors & Modulating Dampers

• Prep Mode, Cooking Mode, Cooldown, & Idle

• Constant auto calibration of Optic sensors

• Automatic On, Off & sensor monitoring

• Ease of maintenance & cleaning

• Integration with Building Automation System

• Versatility of component installation

INTELLINOX KEY FEATURES

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

Page 13: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

• BOTH NEW CONSTRUCTION & RETROFIT

• ALL HOOD SIZES & TYPES

• ALL EXHAUST FANS & MAKE-UP AIR UNITS WITH 3-PHASE MOTORS

APPLICATIONS

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

Page 14: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

• 3.3.35.2 – Limited combustible material

• 7.3.4 – Access panel for dampers

• 7.5.4 – Devices with duct penetration listed UL1978

• 8.2.1.1 – Min air velocity 500ft/min in any duct

• 8.2.2.2 – Air balancing

• 8.2.2.3 – Lower exhaust air volume when not cooking

• 9.1.2 – Listed dampers permitted in ducts

CODES & REGULATIONS

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

• UL710 – Exhaust hoods for commercial equipment

• UL1978 – Grease ducts

• UL2017 – General-purpose signaling devices and systems

• CSA508A – Industrial control equipment

• NSF-2 – Commercial food equipment

• FCC part 15 subpart B –Unintentional radiators

• CE 2004/108/EC –Electromagnetic compatibility

STANDARDS & COMPLIANCE

Page 15: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

ENERGY STAR 2015EMERGING TECHNOLOGY AWARD

Page 16: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

• Average new fan speed of 65% (Temp & Optics)

• Average new fan speed of 50% (Temp, Optics & MD)

• Conditional air savings – Up to 70%

• Average payback – 1 to 3 years

• Improved Safety with auto on & off capability

• Improved Comfort with reduced hood air noise

• Sustainability by helping to achieve LEED credits

• Can qualify for local Utility Rebates

ENERGY SAVINGS & BENEFITS

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

Page 17: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

SCENARIO• Local restaurant

• 3 hoods

• 3 exhaust fans

• 16 hour / day runtime

• Retrofit

• Install time: 2 nights

CASE STUDY: RESTAURANT

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

Page 18: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

CASE STUDY: RESTAURANT

SCENARIO• Installed cost: $13,500.00

• Motor operating savings: $1,851.00/year

• Heating savings: $3,383.00/year

• Cooling savings: $1,971.00/year

TOTAL SAVINGS: $7,205.00/yearPAYBACK PERIOD: 1.9 years

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

Page 19: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

AIR SOLUTIONS & BALANCING

Page 20: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

• Offer complete turnkey installations of Intellinox systems

• All in-house labor by licensed electricians

• Complimentary walkthroughs & site visits

• In-house design engineering services

• Free energy analyses

• Over 10 years demand ventilation installation experience

• Hood performance testing

WHAT WE OFFER

AIR SOLUTIONS & BALANCING USABALANCING.COM T 603-262-9292

Page 21: INTELLINOX DEMAND CONTROL KITCHEN VENTILATIONfiles.ctctcdn.com/9772c893201/ecc5cc3c-5d49-4d08-a... · The Intellinox commercial kitchen ventilation controls save energy, operational

CONTACT AIR SOLUTIONS

CAMERON [email protected] 603-262-9292

USAbalancing.com40 King Street Unit 1, Auburn NH