intake filters and filter silencers...telephone (847) 223-8636 • fax (847) 223-8638 e-mail - info...

2
INTAKE FILTERS and FILTER SILENCERS Bulletin “FA” Stoddard Silencers Stoddard Silencers, Inc. 1017 Progress Drive • Grayslake, Illinois 60030 Telephone (847) 223-8636 • FAX (847) 223-8638 E-Mail - info @ stoddardsilencersinc.com Web page - www.stoddardsilencersinc.com

Upload: others

Post on 05-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INTAKE FILTERS and FILTER SILENCERS...Telephone (847) 223-8636 • FAX (847) 223-8638 E-Mail - info @ stoddardsilencersinc.com Web page - C_Bulletin FA 3/6/04 8:05 AM Page 1 Air Intake

INTAKE FILTERSandFILTER SILENCERS

Bulletin “FA”

StoddardSilencers

Stoddard Silencers, Inc.1017 Progress Drive • Grayslake, Illinois 60030Telephone (847) 223-8636 • FAX (847) 223-8638E-Mail - info @ stoddardsilencersinc.comWeb page - www.stoddardsilencersinc.com

C_Bulletin FA 3/6/04 8:05 AM Page 1

Page 2: INTAKE FILTERS and FILTER SILENCERS...Telephone (847) 223-8636 • FAX (847) 223-8638 E-Mail - info @ stoddardsilencersinc.com Web page - C_Bulletin FA 3/6/04 8:05 AM Page 1 Air Intake

Air Intake Filter and Filter SilencerThe Series F64 Air Intake Filter and Filter Silencer isdesigned to mount directly on the inlet of an engine, blow-er or compressor. It will provide 16dB to 20dB noise reduc-tion and the paper filter media has an efficiency of 99% on1 micron particles.

SERVICE LIFE & CLEANING: The service life of the ele-ment is dependent upon the surrounding environment andcannot be predicted.

To prevent COLLAPSING of the filter element, STODDARDSILENCERS recommends the differential pressure across

Air Intake Filters and Filter SilencersF64

the filter element NOT exceed 15 inches of water column.Positive indication that the element requires cleaning orreplacement can be provided with STODDARDSILENCERS model A40-108 Pressure Drop Indicator, at anextra charge.

To extend service life, rap element gently to dislodge accu-mulated dirt. An alternate method is to direct compressedair (75 PSIG max) through the element opposite to thedirection of air flow. THE FILTER ELEMENT MUST EVEN-TUALLY BE REPLACED.

ALTERNATE FILTRATION MEDIAAVAILABLE FOR F64

REFER TO PAGE FOUR

Pre-Filter wrap available at added costConsult Factory

(90% on 75 micron particles and larger)

F64 shown with optional A40-108 Pressure Drop Indicator.

Sizes 10", 12" and 14" are FILTERS only

F64-1

F64-11⁄2

F64-2

F64-21⁄2

F64-3

F64-4

F64-5

F64-6

F64-8

F64-10

F64-12

F64-14

11"1⁄2 NPT

111⁄2" NPT

12"1⁄2 NPT

121⁄2" NPT

13"1⁄2 NPT

14"1⁄2 NPT

5" NPT/FLG

16"1⁄2 Flange

18"1⁄2 Flange

10"1⁄2 Flange

12"1⁄2 Flange

14"1⁄2 Flange

10

10

10

10

16

16

16

20

20

26

26

26

4

4

4

4

5

5

5

5

10

151⁄2

151⁄2

151⁄2

7

7

7

7

8

8

8

8

13

20

20

20

35

80

135

180

285

520

750

1235

2125

3335

4675

5655

9

9

10

10

20

20

23

40

50

95

100

115

F8-108

F8-108

F8-108

F8-108

F8-109

F8-109

F8-109

F8-110

F8-111

F8-137

F8-137

F8-137

ModelA

ConnectionSize

B C D RatedCFM Wt.

ReplacementElementNumber

F64 Series

30

20

10

063 125 250 500 1K 2K 4K 8K 10K

Typical Attenuation Curve

TYPI

CA

LAT

TEN

UAT

ION

- db

OCTAVE BAND CENTER FREQUENCY (Hz)

2

B

C

D

AConnection

Size

C_Bulletin FA 3/6/04 8:05 AM Page 2