intake filters and filter silencers...telephone (847) 223-8636 • fax (847) 223-8638 e-mail - info...
TRANSCRIPT
INTAKE FILTERSandFILTER SILENCERS
Bulletin “FA”
StoddardSilencers
Stoddard Silencers, Inc.1017 Progress Drive • Grayslake, Illinois 60030Telephone (847) 223-8636 • FAX (847) 223-8638E-Mail - info @ stoddardsilencersinc.comWeb page - www.stoddardsilencersinc.com
C_Bulletin FA 3/6/04 8:05 AM Page 1
Air Intake Filter and Filter SilencerThe Series F64 Air Intake Filter and Filter Silencer isdesigned to mount directly on the inlet of an engine, blow-er or compressor. It will provide 16dB to 20dB noise reduc-tion and the paper filter media has an efficiency of 99% on1 micron particles.
SERVICE LIFE & CLEANING: The service life of the ele-ment is dependent upon the surrounding environment andcannot be predicted.
To prevent COLLAPSING of the filter element, STODDARDSILENCERS recommends the differential pressure across
Air Intake Filters and Filter SilencersF64
the filter element NOT exceed 15 inches of water column.Positive indication that the element requires cleaning orreplacement can be provided with STODDARDSILENCERS model A40-108 Pressure Drop Indicator, at anextra charge.
To extend service life, rap element gently to dislodge accu-mulated dirt. An alternate method is to direct compressedair (75 PSIG max) through the element opposite to thedirection of air flow. THE FILTER ELEMENT MUST EVEN-TUALLY BE REPLACED.
ALTERNATE FILTRATION MEDIAAVAILABLE FOR F64
REFER TO PAGE FOUR
Pre-Filter wrap available at added costConsult Factory
(90% on 75 micron particles and larger)
F64 shown with optional A40-108 Pressure Drop Indicator.
Sizes 10", 12" and 14" are FILTERS only
F64-1
F64-11⁄2
F64-2
F64-21⁄2
F64-3
F64-4
F64-5
F64-6
F64-8
F64-10
F64-12
F64-14
11"1⁄2 NPT
111⁄2" NPT
12"1⁄2 NPT
121⁄2" NPT
13"1⁄2 NPT
14"1⁄2 NPT
5" NPT/FLG
16"1⁄2 Flange
18"1⁄2 Flange
10"1⁄2 Flange
12"1⁄2 Flange
14"1⁄2 Flange
10
10
10
10
16
16
16
20
20
26
26
26
4
4
4
4
5
5
5
5
10
151⁄2
151⁄2
151⁄2
7
7
7
7
8
8
8
8
13
20
20
20
35
80
135
180
285
520
750
1235
2125
3335
4675
5655
9
9
10
10
20
20
23
40
50
95
100
115
F8-108
F8-108
F8-108
F8-108
F8-109
F8-109
F8-109
F8-110
F8-111
F8-137
F8-137
F8-137
ModelA
ConnectionSize
B C D RatedCFM Wt.
ReplacementElementNumber
F64 Series
30
20
10
063 125 250 500 1K 2K 4K 8K 10K
Typical Attenuation Curve
TYPI
CA
LAT
TEN
UAT
ION
- db
OCTAVE BAND CENTER FREQUENCY (Hz)
2
B
C
D
AConnection
Size