institute of combustion and power plant technologyieaghg.org/docs/general_docs/tsb_oxyfuel/01 -...
TRANSCRIPT
Prof. Dr. techn. G. Scheffknecht
Institute of Combustion and Power Plant Technology
Experiences and Results of SO3
Measurements Performed under
Oxy‐Coal Fired Conditions
IEA-GHG – Special Workshop
“Addressing the SO2/SO3/Hg and Corrosion Issues in
Oxyfuel Combustion Boiler and Flue Gas Processing Units”
Rembrandt Hotel, London - 25/26 January 2011
Reinhold SpörlJörg Maier
Günter Scheffknecht
[email protected]@ifk.uni-stuttgart.de
2
Outline
1. Background: SO3 generation; H2SO4 formation; Acid dew point;
Controlled condensation method
2. Experiences measuring SO3:
• Choice of the filter material
• Temperature of the SO3 condenser
• SOx concentrations in air and oxyfuel firing mode
• Influence of SCR catalyst on acid due point
3. Conclusions
4. Outlook
SO3 sources (1/2)
• Variable amounts of sulfur (e.g. pyrite FeS2) in coal, e.g.:
Sulfur content in central European brown coals: 0.2 up to 5 % [1]
• Oxidation of sulfur to SO2 during coal combustion
• Further oxidation of part of the SO2 to SO3
Predominant oxidation reactions in the boiler [2]:
M indicates a caytalyst (e.g. Fe2O3); Most efficient at 700 to 800°C.
Relatively slow; Equilibrium on left side at high temperatures
3
MSO M OSO 32 +→++
32 SO OSO →+
SO3 sources (2/2)
• SO3 generation mainly depends on:
− O2 concentration in boiler: possible increase in oxyfuel firings
− SO2 concentration in boiler: increase by factor 3-4 in oxyfuel firings
− Presence of catalytically active material (e.g. Fe2O3 in fly ash)
− Residence time of the flue gas between 700 and 800°C
• SO2 oxidation takes place:
−In the boiler and economizer: depending on coal and boiler (in air firings: up to
1.6% of toal SO2 converted) [3]
−In the SCR-reactor (in air firings up to 1.25% of total SO2 converted) [3]
4
H2SO4 formation and dew point (1/3)
• SO3 and H2O form vapour sulfuric acid H2SO4 [4]:
− Formation starts at about 400°C.
− At about 200°C almost all SO3 is
consumed.
5
)g(42
(g)2
(g)3 SOH OHSO →+
H2SO4 formation and dew point (2/3)
• Condensation of H2SO4 when temperature falls below acid dew
point temperature: TDew = f(pSO3, pH2O)
• TDew calculation at IFK according
to Zarenezhad [5]
• TDew formerly calculated according
to Verhoff/Banchero [6] or Okkes [7]:
−Verhoff/Banchero equation overpredicts TDew
−Okkes equation underpredicts TDew
6
H2SO4 formation and dew point (3/3)
• Acid dew points calculated according to Zarenezhad equation:
• Typical dew points in air fired power plants: 95-150°C
7
Controlled condensation method (1/1)
• No other flue gas component condensing at 100-200°C
• Separation of H2SO4 through selective condensation
• Condenser: Glas coil tempered between water and acid dew point
• Sample train:
• Sample analysis by titration or chromatography8
in out
H2SO4 condenser
Experiences: Choice of filter material (1/5)
• At IFK in-stack dust removal is considered to be the most reliable
configuration, to avoid H2SO4 condensation on the filter
• Possible filter material for in-stack dust removal:
−Glass wool: glass fibers consisting of SiO2 (approx. 70 %), Al2O3, CaO, K2O,
MgO and NaO
−Quarz wool: quarz fibers consisting of >99% SiO2
9
Experiences: Choice of filter material (2/5)
• Handling of glass and quarz wool:
−Glass wool:
cheap
easy to handle
−Quarz wool:
very brittle
breaks into small fibrous dust when force is applied
difficult to apply on the filter cartrige of the probe
possible contamination of the sample by small fibre
pieces
10
Experiences: Choice of filter material (3/5)
• Experiments on IFK‘s 20 kW entrain flow reactor (air fired)
• Firing of 1.5 kg/h El Cerrejon hard coal
• SO2 content in the flue gas: ~ 1300 mg/m3 (STP)
• SO3 measurements at a SCR catalyst (Tin • 395°C)11
• Sampling with glass wool for dust removal (all samples taken behind catalyst)
−Variation of the sampling volume:
acid mist not or late (after 30 min of sampling) visible in H2SO4 collector
−Addition of SO2 with secondary air (sampling volume 190l (STP)):
acid mist visible after 10-15 minutes of sampling
Saturation behaviour
Experiences: Choice of filter material (4/5)
12
No. Sampling volume [l] (STP) SO3 in fluegas [mg/m3] (STP)
A 96 0.3
B 218 0.2
C 247 0.3
D 349 3.6
Shorter saturation time
No. SO2 in fluegas [mg/m3] (STP) SO2 in fluegas [mg/m3] (STP)
E 5580 9.4
F 5380 29.9
G 5200 1.9
Significant variations
Experiences: Choice of filter material (5/5)
• Sampling with quarz wool for dust removal
−Sampling volume ~ 200l (STP)
−Sampling before and behind SCR catalyst:
acid mist visible after 1-2 minutes of sampling, minor
variation of concentrations
13
No. Sampling position SO3 in fluegas [mg/m3] (STP)
H Before catalyst 5.8
I Before catalyst 4.4
J Behind catalyst 52.0
K Behind catalyst 53.3
For comparison (sampling with glass wool)
B Before catalyst 0.2
Dust removal by quarz wool
Dust removal by glass woolNo saturation behaviour with quarz wool
Experiences: SO3 condenser temperature (1/2)
• Temperature of condenser coil between acid and water dew point
−H2SO4 condensation follows the phase
equilibrium according to the acid dew point:
If the condenser coil is tempered to 121°C,
1.7 ppm H2SO4 remain in the gas phase
−Temperature far below acid dew point, to
asure a high level of H2SO4 condensation
−Temperature high enough above water
dewpoint to avoid water condensation in coil:
20-30K above water dew point14
Water dewpoints for water contents of 12,
28 and 35 Vol-%
Experiences: SO3 condenser temperature (2/2)
• Water and acid dew points in air and oxyfuel mode measured at
IFK‘s 500kW PC combustion rig:
(calculated from H2SO4 and water concentrations)
− Maximum water dewpoint (with soot blower: water content >35 Vol-%): 75°C
• Recommended coil temperature:
−Air firing: 75-80°C
−Oxyfuel firing: 85-95°C (depending on water concentration)
15
Air firing Oxyfuel firing
Water concentration [Vol-%] 11.8 28.3
Water dewpoint [°C] 49.1 67.8
Acid dewpoint [°C] 130-140 ~160
Measurements at IFK‘s 500kW combustion rig (1/3)
• Measurements at IFK‘s 500kW PC combustion rig
• Firing of ~50kg/h high sulfur brown coal
• Operation in air and oxyfuel mode16
Bottomash
ID fanESPSCR
Storagetanks
FD/ RG fan
O2
CO2
Stack
Air O2 CO2
Pre-Heater
Coal feeding
Air
By-passes
Measurements at IFK‘s 500kW combustion rig (2/3)
• SO2 concentrations:
−Concentrations increased by a factor of 2.6 to 3.1 (air : oxyfuel)
−Maximum SO2 concentrations in oxyfuel firing mode: approx. 11700 mg/m3
(STP) [reference O2: 6 Vol-%]
• SO3 concentrations (measured at different positions along the
flue gas path):
SO3 concentrations in air firing mode:
up to 40 mg/m3 (STP) [reference O2: 6 Vol-%]
High SO3 concentrations in oxyfuel firing mode:
up to 200 mg/m3 (STP) [reference O2: 6 Vol-%]
17
Measurements at IFK‘s 500kW combustion rig (3/3)
− Increase of acid dew point over SCR catalyst (qualitative):
18
Increase of approx.
30mg/Nm3
Increase of approx.
30mg/Nm3
~2 K
~15 K
Air firing
Oxyfuel firing
Conclusions (1/1)
• Controlled condensation method at IFK:
−Filter material for in-stack dust removal: Quarzwool
−H2SO4 condenser coil temperature:
Air firing: 75-80°C
Oxyfuel firing: 85-95°C (depending on H2O content)
• Significantly higher SO3 concentrations in oxyfuel mode
• Influence of SCR catalyst on acid due point is less pronounced in
oxyfuel firings
19
Outlook
• Future research topics:
−Test and evaluation of continous SO3 analysers (e.g.: Severn Science
analyser, FTIR)
−Evaluation of the influence of fly ash in the gas sampling probe on SO3
measurements
−Evaluation of the SO3 evolution over the flue gas path in air and oxyfuel
combustion, e.g.:
SO3 capture in the ESP
SO3 formation in the boiler
Possibility of SO3 enrichment due to flue gas recirculation
20
Literature
[1] P. ADOLPHI ; M. STÖRR ; P.G. MAHLBERG ; H.H. MURRAY ; E.M. RIPLEY: Sulfur sources and sulfur bonding of some central European attrital brown coals. In: International Journal of Coal Geology 16 (1990), S. 185–188
[2] T. L. JORGENSEN, H. LIVBJERG, P. GLARBORG: Shorter Communication - Homogeneous and heterogeneously catalyzed oxidation of SO2; In: Chemical Engineering Science 62 (2007), S. 4496 – 4499
[3] R.K. SRIVASTAVA ; C.A. MILLER ; C. ERICKSON ; R. JAMBHEKAR: Emissions of sulfur trioxide from coal fired power plants. In: Journal of the Air & Waste Management Association 54 (2004), S. 750–762
[4] R. HARDMAN ; R. STACY: Estimating Sulfuric Acid Aerosol Emissions from Coal-Fired Power Plants. Conference on Formation, Distribution, Impact, and Fate of Sulfur Trioxide in Utility Flue Gas Streams, 1998
[5] B. ZARENEZHAD: New correlation predicts flue gas sulfuric acid dewpoints. In: Oil & Gas Journal 107 (2009), S. 60–63
[6] F.H. VERHOFF ; J.T. BANCHERO: Predicting dewpoints of flue gases. In: Chemical Engineering Progress 70 (1974), S. 71–72
[7] A. G. OKKES: Get acid dewpoint of flue gas. In: Hydrocarbon Processing 7 (1987), S. 53–55
Literature recommendation (background information on SO3 measurement):
• Workshop Proceedings on Primary Sulfate Emissions from Combustion Sources. Volume I. Measurement Technology., 1978
21
Thank you for your attention!
22