installation guide - aeramax professional

6
INSTALLATION GUIDE AeraMax ® PRO Air Quality Control System: AM III Please read instructions carefully before installing unit

Upload: others

Post on 23-Nov-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INSTALLATION GUIDE - Aeramax Professional

INSTALLATION GUIDEAeraMax® PRO Air Quality Control System: AM III

Please read instructions carefully before installing unit

Page 2: INSTALLATION GUIDE - Aeramax Professional

2

ENGLISHAeraMax® PRO Air Quality Control System: AM IV

1. Access panel2. Filters3. Filter frame4. Main Assembly5. Power Switch6. Access panel latch7. Access panel lock8. Rear housing assembly9. Control panel10. Filter frame window

KEY

1

6

2

7

3

8

9

10

45

Fig 1

Page 3: INSTALLATION GUIDE - Aeramax Professional

3

SAFETY

TOOLS REQUIRED FOR INSTALLATION

PARTS PROVIDED FOR INSTALLATION

PRODUCT INSTALLATION GUIDELINES

WARNING: To avoid the risk of electrocution confirm the electrical supply has been disconnected or switched off before beginning any installation work.

Confirm no electrical wiring, utility pipes, or duct work is located directly behind the installation / drilling area.

On a stud wall, it is strongly recommended at least 2 mounting anchors for the air purifier be mounted to an existing stud.

• Electricdrill,drillbits(notincluded)• #2Phillipsand#2FlatHeadscrewdrivers(notincluded)• Wirenuts(notincluded)• Level(notincluded)• Mountingtemplate(included)

• DrywallAnchors-10mmOD• PanHeadPhillipsScrews

8”

12”

27”

8”

27”

80”

8”

Fig 2

Americans with Disabilities Act (ADA): BesuretofollowallADAguidelinespertainingto“Objectsprotrudinginto a circulation path.” For more information visit www.ada.gov.

Place the mounting template provided on the wall where the air purifier is to be installed. If air purifier is being mounted high on the wall make sure the top edge of the unit is positioned at least 8”inches(21cm)belowtheceilingtoallowforfilterreplacement(seeFig2).

Page 4: INSTALLATION GUIDE - Aeramax Professional

4

Place the air purifier face up on a flat, stable work surface. Open the access panel by pressing in latches oneachsideoftheunit(Fig3).

Using provided template ensure electrical outletboxislocatedbehindcablehole(A)in Rear Housing assembly (Fig 9). Drillholes and place anchors in wall.If mounting on concrete, cinder block or brick type walls route the wires through the“punch-out”holemarked(B)inFig9.

Disconnect main housing assemblyfrom rear housing assembly. Separate main housing from rear housing.Liftmainhousingassemblyaway from rear mounting housing (Fig8).

Open access panel and remove filter assembly by pulling out on top of side edges of frame, then lifting. NOTE: remove all plasticwrapfromfilters(Fig4).

Check for washers at all mounting screw locations (Fig 10). Pull wiresfrom electrical outlet box through hole in rear housing. Align housing over anchors and securely install all mounting screws.

Removethefourhousingscrews(Fig5&6)andsetasideforre-assembly.

At the location of the two upper housingscrews(Fig5), inserta flathead screwdriver and gently twist to release tab as shown in Fig 7. This will disconnect main housing assembly from the rear housing assembly.

Attachwiresfromelectricaloutletboxtowireslocatedinsiderearhousingusingwirenuts.Matchupline(black)andneutral(white)wires(Fig11).Makesureall connections are made in accordance with federal, state and local codes and regulations.

MOUNTING REAR HOUSING AND MAIN ASSEMBLY

REAR HOUSING INSTALLATION & WIRING

Test the electrical outlet box first to ensure rated power requirements are met before beginning installation. Remove air purifier from its shipping carton and remove all packing material.

Reference rear housing and locate desired mounting location. Again, it is strongly recommended at least 2 mounting anchors for the air purifier be mounted to an existing stud.

1 2

3 4

1 2

3 4

A

B

A

B

Fig 3

Fig 7

Fig 4

Fig 8

Fig 5 Fig 6

Fig 9 Fig 10

Fig 11

Page 5: INSTALLATION GUIDE - Aeramax Professional

5

Make sure filters are in correct order - pre-filter/ carbon filter/HEPAfilter-andinsertedintofilterframe(Fig16).

Oncetheunitisclosedre-establishpower.Lightsonthecontrolpanelwill be visible through the lens, indicating the unit is operational (Fig20).Thepowerlightindicatorwill flash once a second.

IMPORTANT: Make sure filter detection area aligns with window infilterframe(Fig17).

Close front panel by pressing firmly until both sides latch closed (Fig19).

The power connector (B, in Fig12)willcarrypowerfromtherearhousing to the main housing once the assemblies are fully seated. The main assembly will attach to the rear housing assembly by the four screws previously removed (Fig 5&6). Two snap hooks (A,inFig12)willholdthemainandrear assemblies together until the screws can be installed.

Carefully align the main assembly with the rear housing assembly. Slowly press into place until snap is heard, and there is no gap betweentheassemblies(Fig13).The unit should now support its own weight.

Open front panel by pressing latches on both sides of unit. Allow door to open fully. Insert filters – IMPORTANT: make sure filter detection window is aligned in upperrightcorner(Fig18).

To restrict access to the control panel and filters the unit can be locked. To lock, insert the key provided and rotateclockwise¼turn(Fig21).

Installfourscrews(previouslyremoved)tosecuremainassemblytorearhousingassembly(Fig14&15).

RE-INSTALLING FILTERS

LOCKING ACCESS PANEL

MAIN ASSEMBLY INSTALLATION

1 2

3 4

1 2

3 4

WARNING: To avoid the risk of electrocution confirm the electrical supply has been disconnected or switched off before continuing any installation work.

IMPORTANT: Make sure all plastic wrap is removed from filters.

Fig 18Fig 16 Fig 17

Fig 20

Fig 21

Fig 19

Fig 14Fig 12 Fig 13 Fig 15

B

AA

Page 6: INSTALLATION GUIDE - Aeramax Professional

Fellowes, Inc.1789 Norwood Ave

Itasca, Illinois 60143-1095 USA630-893-1600

1-800-477-7940Product Support: 1-800-945-4545

www.aeramaxpro.com

©2014 Fellowes, Inc. Part No. 408530 Rev B