Read FirstEclipse Node Installation and Commissioning FormsRev 3 June 07

&C&"Arial,Bold"Harris Stratex Networks&L&7Eclipse Node Forms: V1.3 June06&C&"Arial,Bold"&8Commercial-In-Confidence&R&8&P

Eclipse Inst & Comm FormEclipse Node Installation and Configuration FormFor Site:Installer:INUInstaller Contact Details:Scheduled Start Date:Scheduled Completion Date:New or Existing Site:INUeElectrical Supply OK yes/no:Site Grounding OK yes/no:Antenna Mounts OK yes/no:Site Security OK yes/no:Site Plans Included yes/no:Master Site DataBuild / As-Built DataPortal Entry To / Record FromCommentsNodeNode Type INU or INUeToNode NameToSite NameToSite Grid ReferenceToTech Services contact detailsToNOC contact detailsSite locationSite accessSee attached mapRack number/nameINU location in rackChassis serial number(All serial numbers begin with three letters)NCC serial numberFAN serial number(s)License serial number(Enter from NCC FlashCard label)Licensed capacityLicense capacity checkedFrom-48Vdc power supply connectionNetworkingTerminal IP AddressToSubnet MaskToStatic or dynamic routingToStatic routing dataDestination, mask, interface, next hop, default gatewayToDestination, mask, interface, next hop, default gatewayToDestination, mask, interface, next hop, default gatewayToStatic routing dataDHCP yes/no; address rangeToTrap destinationsToLink 1Link name/numberToRemote end site nameToRemote end node/terminal nameToLocal antenna type(s)Local antenna diameter(s)Antenna serial number(s)Height on tower / pole mount ID`Initial pointing (compass/map ref)PolarizationProtected yes/noToProtection typeToODU(s) direct mounting, yes/noODU typeODU serial numberODU cable length(s) requiredLocation of RAC in INUToRAC typeRAC serial numberTx frequencyToRx frequencyToT/R spacingToTx powerToDetected forward powerFromCapacityToModulationToATPC yes/noToATPC Target Rmte Fade MarginToATPC Fade MarginFromATPC Max PwrToATPC Min PwrToATPC dataExpected RSLIndicated RSLFromExpected RSSIIndicated RSSIFromExpected fade marginMeasured fade marginFromG.826 link checkFromAlarms checkFromPerformance checkFromLink 1Link 2Link name/numberToRemote end site nameToRemote end node/terminal nameToLocal antenna type(s)Local antenna diameter(s)Antenna serial number(s)Height on tower / pole mount IDInitial pointing (compass/map ref)PolarizationProtected yes/noToProtection typeToODU(s) direct mounting, yes/noODU typeODU serial numberODU cable length(s) requiredLocation of RAC in INUToRAC typeRAC serial numberTx frequencyToRx frequencyToT/R spacingToTx powerToDetected forward powerFromCapacityToModulationToATPC yes/noToATPC Target Rmte Fade MarginToATPC Fade MarginFromATPC Max PwrToATPC Min PwrToATPC dataExpected RSLMeasured RSLFromExpected RSSIIndicated RSSIFromExpected fade marginMeasured fade marginFromG.826 link checkFromAlarms checkFromPerformance checkFromLink 2Link 3Link name/numberToRemote end site nameToRemote end node/terminal nameToLocal antenna type(s)Local antenna diameter(s)Antenna serial number(s)Height on tower / pole mount IDInitial pointing (compass/map ref)PolarizationProtected yes/noToProtection typeToODU(s) direct mounting, yes/noODU typeODU serial numberODU cable length(s) requiredLocation of RAC in INUToRAC typeRAC serial numberTx frequencyToRx frequencyToT/R spacingToTx powerToDetected forward powerFromCapacityToModulationToATPC yes/noToATPC Target Rmte Fade MarginToATPC Fade MarginFromATPC Max PwrToATPC Min PwrToATPC dataExpected RSLIndicated RSLFromExpected RSSIIndicated RSSIFromExpected fade marginMeasured fade marginFromG.826 link checkFromAlarms checkFromPerformance checkFromLink 3Link 4Link name/numberToRemote end site nameToRemote end node/terminal nameToLocal antenna type(s)Local antenna diameter(s)Antenna serial number(s)Height on tower / pole mount IDInitial pointing (compass/map ref)PolarizationProtected yes/noToProtection typeToODU(s) direct mounting, yes/noODU typeODU serial numberODU cable length(s) requiredLocation of RAC in INUToRAC typeRAC serial numberTx frequencyToRx frequencyToT/R spacingToTx powerToDetected forward powerFromCapacityToModulationToATPC yes/noToATPC Target Rmte Fade MarginToATPC Fade MarginFromATPC Max PwrToATPC Min PwrToATPC dataExpected RSLIndicated RSLFromExpected RSSIIndicated RSSIFromExpected fade marginMeasured fade marginFromG.826 link checkFromAlarms checkFromPerformance checkFromLink 4DAC 16xDAC location in INUToSerial numberE1 or DS-1ToBal or UnbalToDS1 encodingToDS1 line lengthToPort / trib namesToConnect toDAC 16xDAC 16xDAC location in INUToSerial numberE1 or DS-1ToBal or UnbalToDS1 encodingToDS1 line lengthToPort / trib namesToConnect toToDAC 16xDAC 4xDAC location in INUToSerial numberE1 or DS-1ToBal or UnbalToDS1 encodingToDS1 line lengthToPort / trib namesToConnect toToDAC 4xDAC 155o / 2x155oDAC locationToSerial numberFO cable typePort / trib nameToDAC 155o / 2x155oDAC 2x155eDAC locationToSerial numberPort / trib nameToDAC 2x155eDAC ESDAC locationToSerial numberFromMode of operationToChannel 1 capacityToChannel 2 capacityToDuplex & speedToMdiXToPort priority (Ports 1 to 4)ToPriority mappingToFlow control yes/noToDisable address learning y/nToMax frame sizeToPort namesToDAC ESDAC GEDAC locationToSerial numberFromMode of operationToChannel 1 capacityToChannel 2 capacityToDuplex & speedToMdiXToPort priority (Ports 1 to 4)ToPriority MappingToFlow control yes/noToDisable address learning y/nToMax frame sizeToVLAN taggingToPort namesToDAC GEDAC 155oMDAC location in INUToSerial numberFromFrame typeToClock modeToNMS transportToSignal degrade thresholdToTrib nameToBus port naming conventionToSignal labelToDAC 155oMDAC 3xE3/DS3DAC location in INUToSerial numberFromTributary typeToTrib 1 nameToTrib 2 nameToTrib 3 nameToDAC 3xE3/DS3DAC 3xE3/DS3MDAC location in INUToSerial numberFromModeToTributary typeToTrib 1 nameToTrib 2 nameToTrib 3 nameToDAC 3xE3/DS3MTraffic CircuitsBus configurationToCircuit connectionsToCircuit namingTo(Each circuit in a network should have a unique name, and that name should be entered at all Nodes that carry that circuit. Trib names should also relate to its circuit name to permit easy association of trib with circuit when setting a DAC BER test using the circuit loopback feature.)AUXAUX location in INUToSerial numberFromAuxiliary portsPort 1: function, type, port settings, nameToPort 2: function, type, port settings, nameToPort 3: function, type, port settings, nameToAuxiliary portsAuxiliary circuitsPort 1: to/circuit nameToPort 1: to/circuit nameToPort 1: to/circuit nameToAuxiliary circuitsToAlarm I/OPort layoutToPort 1, type, active conditionToPort 2, type, active conditionToPort 3, type, active conditionToPort 4, type, active conditionToPort 5, type, active conditionToPort 6, type, active conditionToAlarm I/OAlarm actionsDestination IP address, slot, and output. Trigger(s).ToDestination IP address, slot, and output. Trigger(s).ToDestination IP address, slot, and output. Trigger(s).ToDestination IP address, slot, and output. Trigger(s).ToDestination IP address, slot, and output. Trigger(s).ToAlarm actionsAUXNPCSerial numberOperation OK yes/noFrom(Check NCC protection)NPCDate/Time(Specify Date/Time setting)ToBER Circuit ChecksTrib-trib BER check(Specify the tri/cct[s] and period)FromAlarms exit checkActive alarms yes/noFromGround checksSingle point bldg ground y/nMaster Ground Bar resistanceRack to MGB resistance-48V PSU to MGB resistanceTower ground resistance(s)Other resistance readingsMeter usedSite Inspection Report completed yes/noHardware Installation completedName:Signature:Date:Node Installation & Tests completedName:Signature:Date:Completion Comments

&C&"Arial,Bold"Harris Stratex Networks&L&8Eclipse I+C Form: V1.3 June06&C&"Arial,Bold"Commercial-In-Confidence&R&PSite Comments:Site Comments:Slot Allocations1= 2= 3= 4= 5= 6= 7= 8= 9= 10=General Instructions:Slot Allocations1= 2= 3= 4= 5= 6= 7= 8= 9= 10=To = Enter into PortalFrom = Enter from Portal2 for INUeQty two for space diversityTwo entries required for space diversity.Two ODUs/RACs for protected.e.g. ODU 300ep/hp/sp or ODU 100Check to see that there are no active alarms.Qty two for space diversityTwo entries required for space diversity.Check to see that there are no active alarms.Qty two for space diversityTwo entries required for space diversity.Check to see that there are no active alarms.Qty two for space diversityTwo entries required for space diversity.Check to see that there are no active alarms.Two ODUs/RACs for protected.e.g. ODU 300ep/hp/sp or ODU 100Two ODUs/RACs for protected.e.g. ODU 300ep/hp/sp or ODU 100Two ODUs/RACs for protected.e.g. ODU 300ep/hp/sp or ODU 100Check both Tx-Rx combinations for a protected link.Check both Tx-Rx combinations for a protected link.Check both Tx-Rx combinations for a protected link.Check both Tx-Rx combinations for a protected link.

Example I&C FormEclipse Node Installation and Configuration FormFor Site: LakesideInstaller:Joeseph BrownINUInstaller Contact Details:021 362 700Scheduled Start Date:10-Sep-05Scheduled Completion Date:14-Sep-05New or Existing Site:ExistingINUeElectrical Supply OK yes/no:YesSite Grounding OK yes/no:YesAntenna Mounts OK yes/no:YesSite Security OK yes/no:YesSite Plans Included yes/no:YesMaster Site DataBuild / As-Built DataPortal Entry To / Record FromCommentsNodeNode Type INU or INUeINUToTerminal NameE101ToSite NameLakesideToSite Grid ReferenceEastxxx SouthxxxToTech Services contact details021 362 701ToNOC contact details021 362 702Site location10km west of EkatahunaSite accessVia Ridge road at first bridgeSee attached mapRack number/name2BINU location in rackDirectly under terminal E104Chassis serial numberLES00934567(All serial numbers begin with three letters)NCC serial numberLEX00099997FromFAN serial number(s)LER00094564License serial numberSNI35435FromLicensed capacity40xE1 for slot 1, 40xE1 for slot 2.License capacity checked40xE1 for slot 1, 40xE1 for slot 2.10xE1 for slots 3 & 4.From-48Vdc power supply connectionProvide and install 12A Cct Breaker on supply panel at top of rackNetworkingTerminal IP Address192.168.10.1ToSubnet Mask225.225.255.0.ToStatic or dynamic routingRIP 2ToStatic routing dataToDestination, mask, interface, next hop, default gatewayDestination, mask, interface, next hop, default gatewayToDestination, mask, interface, next hop, default gatewayStatic routing dataN/ADHCP yes/no; address rangeYes, 192.168.10.2 to 192.168.10.10ToTrap destinationsN/AToLink 1Link name/numberLakeside-BelmontToRemote end site nameBelmontToRemote end node/terminal nameE103ToLocal antenna type(s)VHLP2-180-EXLocal antenna diameter(s)0.6MAntenna serial number(s)AN35235Height on tower / pole mount ID21M`Initial pointing (compass/map ref)74 degreesPolarizationVerticalProtected yes/noNoToProtection typeN/AToODU(s) direct mounting, yes/noYesODU typeODU 300hpODU serial numberSNA7687988FromODU cable length(s) required35mLocation of RAC in INUSlot 1ToRAC typeRAC 30RAC serial numberLEA00878770FromTx frequency17.85 GHzToRx frequency18.25 GHzToT/R spacing400 MHzToTx power17 dBmToDetected forward power17.1 dBmFromCapacity32xE1ToModulation16QAMToATPC yes/noNoToATPC Target Rmte Fade MarginN/AToATPC Fade MarginN/AFromATPC Max PwrN/AToATPC Min PwrN/AToATPC dataExpected RSL-51 dBmIndicated RSL-50 dBmFromExpected RSSI1.25Indicated RSSI1.27FromExpected fade margin35 dBMeasured fade margin37 dBFromG.826 link checkZero errors over 14 hoursFromAlarms checkNo active alarms from Link 1FromPerformance checkAll indications normalFromLink 1Link 2Link name/numberLakeside to Pine HillToRemote end site namePine HillToRemote end node/terminal nameE102ToLocal antenna type(s)VHLP2-180-EXLocal antenna diameter(s)0.6MAntenna serial number(s)SN12495Height on tower / pole mount ID21MInitial pointing (compass/map ref)178 degreesPolarizationVerticalProtected yes/noNoToProtection typeN/AToODU(s) direct mounting, yes/noYesODU typeODU 300hpODU serial numberSNBO93859FromODU cable length(s) required38mLocation of RAC in INUSlot 2ToRAC typeRAC 30RAC serial numberLEN00243551FromTx frequency17.95 GHzToRx frequency18.35 GHzToT/R spacing400 MHzToTx power22dBmToDetected forward power21.5 dBmFromCapacity32xE1ToModulation16QAMToATPC yes/noNoToATPC Target Rmte Fade MarginN/AToATPC Fade MarginN/AFromATPC Max PwrN/AToATPC Min PwrN/AToATPC dataExpected RSL-53 dBmMeasured RSL-52 dBmFromExpected RSSI1.3vIndicated RSSI1.35vFromExpected fade margin33 dBMeasured fade margin32 dBFromG.826 link checkZero errors over 14 hoursFromAlarms checkNo active alarms from Link 2FromPerformance checkAll indications normalFromLink 2Link 3Link name/numberToRemote end site nameToRemote end node/terminal nameToLocal antenna type(s)Local antenna diameter(s)Antenna serial number(s)Height on tower / pole mount IDInitial pointing (compass/map ref)PolarizationProtected yes/noToProtection typeToODU(s) direct mounting, yes/noODU typeODU serial numberODU cable length(s) requiredLocation of RAC in INUToRAC typeRAC serial numberTx frequencyToRx frequencyToT/R spacingToTx powerToDetected forward powerFromCapacityToModulationToATPC yes/noToATPC Target Rmte Fade MarginToATPC Fade MarginFromATPC Max PwrToATPC Min PwrToATPC dataExpected RSLIndicated RSLFromExpected RSSIIndicated RSSIFromExpected fade marginMeasured fade marginFromG.826 link checkFromAlarms checkFromPerformance checkFromLink 3Link 4Link name/numberToRemote end site nameToRemote end node/terminal nameToLocal antenna type(s)Local antenna diameter(s)Antenna serial number(s)Height on tower / pole mount IDInitial pointing (compass/map ref)PolarizationProtected yes/noToProtection typeToODU(s) direct mounting, yes/noODU typeODU serial numberODU cable length(s) requiredLocation of RAC in INUToRAC typeRAC serial numberTx frequencyToRx frequencyToT/R spacingToTx powerToDetected forward powerFromCapacityToModulationToATPC yes/noToATPC Target Rmte Fade MarginToATPC Fade MarginFromATPC Max PwrToATPC Min PwrToATPC dataExpected RSLIndicated RSLFromExpected RSSIIndicated RSSIFromExpected fade marginMeasured fade marginFromG.826 link checkFromAlarms checkFromPerformance checkFromLink 4DAC 16xDAC location in INUSlot 4ToSerial numberLEX00234567FromE1 or DS-1E1ToBal or UnbalUnbalToDS1 encodingN/AToDS1 line lengthN/AToPort / trib namesLak 1 to 8ToConnect toRack BNC panel: ports 1 to 8DAC 16xDAC 16xDAC location in INUToSerial numberFromE1 or DS-1ToBal or UnbalToDS1 encodingToDS1 line lengthToPort / trib namesToConnect toToDAC 16xDAC 4xDAC location in INUToSerial numberFromE1 or DS-1ToBal or UnbalToDS1 encodingToDS1 line lengthToPort / trib namesToConnect toToDAC 4xDAC 155o / 2x155oDAC locationToSerial numberFromFO cable typePort / trib name(s)ToDAC 155o / 2x155oDAC 2x155eDAC locationToSerial numberFromPort / trib name(s)ToDAC 2x155eDAC ESDAC locationToSerial numberFromMode of operationToChannel 1 capacityToChannel 2 capacityToDuplex & speedToMdiXToPort priority (Ports 1 to 4)ToPriority mappingToFlow control yes/noToDisable address learning y/nToMax frame sizeToPort namesToDAC ESDAC GEDAC locationToSerial numberFromMode of operationToChannel 1 capacityToChannel 2 capacityToDuplex & speedToMdiXToPort priority (Ports 1 to 4)ToPriority MappingToFlow control yes/noToDisable address learning y/nToMax frame sizeToVLAN taggingToPort namesToDAC GEDAC 155oMDAC location in INUToSerial numberFromFrame typeToClock modeToNMS transportToSignal degrade thresholdToTrib nameToBus port naming conventionToSignal labelToDAC 155oMDAC 3xE3/DS3DAC location in INUToSerial numberFromTributary typeToTrib 1 nameToTrib 2 nameToTrib 3 nameToDAC 3xE3/DS3DAC 3xE3/DS3MDAC location in INUToSerial numberFromModeToTributary typeToTrib 1 nameToTrib 2 nameToTrib 3 nameToDAC 3xE3/DS3MTraffic CircuitsBus configurationE1ToCircuit connectionsLink 1 ports 1-8 to DAC 16x, slot 4, ports 1-8.Link 1 ports 9 to 32 to Link 2, slot 2, ports 1 to 24.ToCircuit namingLink 1 ports 1-8: Bel/Lak 1 to Bel/Lak 8.Link 1 ports 9-24: Bel/Pin 1 to Bel/Pin 16.Link 1 ports 25-32: Bel/Wel 1 to Bel/Wel 8.ToAUXAUX location in INUSlot 3ToSerial numberLEA05090295FromAuxiliary portsPort 1: function, type, port settings, nameData, sync, P1, default, Aux Bel/LakToPort 2: function, type, port settings, nameToPort 3: function, type, port settings, nameToAuxiliary portsAuxiliary circuitsPort 1: to/circuit namePort 1 to Link 1 port 1, Bel/LakToPort 1: to/circuit nameToPort 1: to/circuit nameToAuxiliary circuitsToAlarm I/OPort layout4xin, 2xoutToPort 1, type, active conditionDigital input, active highToWire to intruder alarm: alarm is active when circuit is broken.Port 2, type, active conditionToPort 3, type, active conditionToPort 4, type, active conditionToPort 5, type, active conditionToPort 6, type, active conditionToAlarm I/OAlarm actionsDestination IP address, slot, and output. Trigger(s).192.168.2.1, slot 4, output 1.AUX alarm input 1.ToAt commissioning check that the destination output (bell) at Belmont activates when the intruder alarm is activated. Also check that the alarm event is raised at the NOC.Destination IP address, slot, and output. Trigger(s).ToDestination IP address, slot, and output. Trigger(s).ToDestination IP address, slot, and output. Trigger(s).ToDestination IP address, slot, and output. Trigger(s).ToAlarm actionsAUXNPCSerial numberOperation OK yes/noFrom(Check NCC protection)NPCDate/Time(Specify Date/Time setting)Sync to Portal PC Date/TimeToBER Circuit ChecksTrib-trib BER check(Specify the trib/cct[s] and period)BER check completed on trib 1 Lakeside to Belmont.FromTribs from Belmont through to Pine Hill will be checked during Pine Hill commissioning.Alarms exit checkActive alarms yes/noNo active alarmsFromGround checksSingle point bldg ground y/nYesMaster Ground Bar resistance0.62 ohmsRack to MGB resistance0.15 ohms-48V PSU to MGB resistance0.27 ohmsTower ground resistance(s)Not possible to measure. Cannot get meter jaws around the ground straps.Other resistance readingsMeter usedProva clamp-on, model DXSerial number 00458Site Inspection Report completed yes/noYes. Attached.Hardware Installation completedName:Joe BrownSignature:Date:14 September 2005Node Installation & Tests completedName:Joesphine BrownSignature:Date:14 September 2005Completion CommentsThe second farm gate is almost off its hinges.One of the two tower-top warning lights is out.Diesel generator checked out OK

&C&"Arial,Bold"Harris Stratex Networks&L&8Eclipse I+C Form V1.3 June06&C&"Arial,Bold"&9Commercial-In-Confidence&R&PCheck to see that there are no active alarms.Qty two for space diversityTwo entries required for space diversity.Qty two for space diversityTwo entries required for space diversity.Check to see that there are no active alarms.General Instructions: 4-wheel drive access only. This time of the year the track will be wet and slippery. Please do a battery check and run the back-up diesel generator for about 30 mins and check associated panel lights. Should all be green.Slot Allocations1= RAC 302= RAC 303= Aux4= DAC 16x5= 6= 7= 8= 9= 10=To = Enter into PortalFrom = Enter from PortalQty two for space diversityTwo entries required for space diversity.Check to see that there are no active alarms.2 for INUeQty two for space diversityTwo entries required for space diversity.Check to see that there are no active alarms.Two ODUs/RACs for protected.e.g. ODU 300ep/hp/sp or ODU 100Two ODUs/RACs for protected.e.g. ODU 300ep/hp/sp or ODU 100Two ODUs/RACs for protected.e.g. ODU 300ep/hp/sp or ODU 100Two ODUs/RACs for protected.e.g. ODU 300ep/hp/sp or ODU 100Check both Tx-Rx combinations for a protected link.Check both Tx-Rx combinations for a protected link.Check both Tx-Rx combinations for a protected link.Check both Tx-Rx combinations for a protected link.

Inst Insp ReportEclipse Node Installation Inspection ReportFor Site:Check for correct and complete installation of:ItemPassFailCommentsAntenna MountingAntenna side support (if used)ODU fasteningODU groundingODU connector weatherproofingODU cable fasteningODU cable groundingLightning surge suppressor(s)RAC to surge suppressor jumper cableINU location in rackINU is labelled (if required)INU groundingINU power supply wiringINU cards are correctly securedUnused slots have blank plates fittedTrib cables are correctly and neatly installedTrib cables are numbered (if required)Alarms all-clearSite left clean and tidySite photos taken (if required)Site ground measurements (if required)Checked by:Name:Signature:Date:Additional Comments:

&C&"Arial,Bold"Harris Stratex Networks&L&8Inst. Insp. Report: V1.2 Mar04&C&"Arial,Bold"Commercial-In-Confidence&R&PCheck antenna fastening onto the pole-mount and the pole-mount fastening onto the structure.Check that collar nuts are secure.Ensure there are no unsupported sections of cable, which may flex in the wind.Check for correct location weatherproofing and grounding.Check grounding integrity all the way to the master ground - not just to an existing rack ground bar.Check power supply load capacity and the integrity of the cabling from the power supply to the INU. Do not rely on a check just to a power pick-up point in the rack. Ensure there is no disconnect device (switch etc) in the ground (+ve) wire.Check to see that no front panel alarms are present. And if Portal connected, that no active alarms are indicated.Measurement of shelter and tower ground resistance.

Acceptance FormEclipse Node Customer Acceptance FormSite Name:Eclipse Node Name:Related documentsReceived Yes/NoEclipse Installation and Commissioning Form:Eclipse Installation Inspection Report:Acceptance Category*CategoryAccepted / Conditionally Accepted / Not Accepted:*If conditionally accepted or not accepted, the action required to achieve acceptance must be detailed in a Remedial Action FormSigned By:CustomerName:Signature:Title:Date:Harris Stratex NetworksName:Signature:Title:Date:

&C&"Arial,Bold"Harris Stratex Networks&L&8Acceptance Form V.1.2 Mar04&C&"Arial,Bold"Commercial-In-Confidence&R&P

Remedial Action FormEclipse Node Remedial Action FormSite Name:Eclipse Node Name:Item No.Description of Remedial Action RequiredResponsibilitySigned As CompletedCustomerName:Signature:Title:Date:Harris Stratex NetworksName:Signature:Title:Date:

&C&"Arial,Bold"Harris Stratex Networks&L&8Remedial Action Form V1.2 Mar04&C&"Arial,Bold"Commercial-In-Confidence&R&P

MBD00AC5304.docIntroduction

Purpose is to provide:

A prompt for preparing data for new installations.

A datapack for installers.

A data entry form to capture additional as-built data.

An as-built record with sign-off.

Associated forms included in this file are:

Installation Inspection Form

Customer Acceptance Form

Remedial Action Form

Navigation:

The Master Site Data column lists entries required. Click on a + tab at the far left of the screen to open up required links and modules for the Node. Click tab to close.

The Build / As-Built Data column is for data entry. Build data is data to be entered at the planning (datapack prep) stage. As-built data is data to be entered at site, mostly from Portal.

The Portal column highlights the data to be entered into Portal and data to be entered from Portal.

The Comments column is to capture any additional data.

See the Example Form for additional guidance.

Forms can be printed.

Important! Please provide feedback on the use of these forms. Feedback is needed to provide guidance on what improvements should be made to assist the application and usability of these forms. Please send feedback to:

Director Installation Practices

Director of Services, Americas

Global Technical Support Manager