inspur 4th generation data center

24
1

Upload: joistj

Post on 24-Jun-2015

82 views

Category:

Internet


2 download

DESCRIPTION

Inspur Newest Data center with leading design concept: natural air combine water cooling system,low pue, modular configuration.

TRANSCRIPT

Page 1: Inspur 4th generation data center

1 � 

Page 2: Inspur 4th generation data center

2 � 

Overall � Introduction � of � Cloud � Computing � Center �  Total � building � area � 

square � meters �  � 

Page 3: Inspur 4th generation data center

3 � 

L m,W m,H/F m � 

Overall � Introduction � of � Cloud � Computing � Center � 

Page 4: Inspur 4th generation data center

4 �  Airview � 

Page 5: Inspur 4th generation data center

5 � 

Able � to � hold �  rack � cabintes � 

Overall � Introduction � of � Cloud � Computing � Center � 

Page 6: Inspur 4th generation data center

6 � 

Be � able � to � hold servers � Overall � Introduction � of � 

Cloud � Computing � Center � 

Page 7: Inspur 4th generation data center

7 � 

Shandong � provincial � departments � 

existing � server � quantity � aboutTake � up � one � separate � module � of � the � Center � 

Take � up � of � the � Center

� 

Overall � Introduction � of � Cloud � Computing � Center � 

Page 8: Inspur 4th generation data center

8 � 

4th � Generation �  � Cloud � Computing � Center � 

Refer � to � data � center � grading � methods � of � Green � Grid � 

Learn � from � 4th � generation � data � center � being � built � by � Microsoft � 

Design � accords � with � TIA � 942 � TIA3 � standards �  � and � some � core � indicators �  � 

reach � TIA4 � standards � 

Page 9: Inspur 4th generation data center

9 � 

Modularization � construction � 

No � interference � design � and � high

� reliability � 

Rapid � copy � and � change � on

� demand � 

Reduce � complexity � and � decrease

� investment � cost � 

Page 10: Inspur 4th generation data center

10 � 

High � density: � the � power � of �  � each � rack � cabinet � reaches � 

Page 11: Inspur 4th generation data center

11 � 

Page 12: Inspur 4th generation data center

12 � 

With � computer � room � full � load, � the � power � consumption � of � IT � devices � is �  kilowatt-hours. � In � most � computer � rooms, � the � power � consumption � of � IT � devices � is � close � to � that � of � refrigeration � equipments. � The � total � power � consumption � of � computer � room � is �  kilowatt-hours � 

Green � & � environ- � ment � friendly � 

Page 13: Inspur 4th generation data center

13 � 

It � fully � uses � natural � cold � for � of � the � time. � 

It � partially � uses � natural � cold � for

�  � of � the � time. � 

PUE � is � reduced � to �  � from �  � of � the � most � data � centers.

Green � & � environ- � ment � friendly � 

Page 14: Inspur 4th generation data center

14 � 

With � full � load, � it � can � save � power � 

kilowatt-hours. �  � 

Page 15: Inspur 4th generation data center

15 �  ELECTRICAL � DISTRIBUTION �  � 

Page 16: Inspur 4th generation data center

16 �  � Shandong � provincial � departments � one � year � power � consumption: � 21.64 � million � kilowatt-hours � Inspur � 4th � Generation � Cloud � Computing � Center � one � year � power � consumption: � 15.15 � million � kilowatt-hours � Save � power �  �  �  �  �  �  �  �  �  �  �  �  �  �  �  �  �  �  �  �  �  � kilowatt-hours � per � year � Power � saving � ratio � 30% � Reduce � CO2 � discharge � amount �  �  �  �  �  �  �  �  �  �  �  �  � tons � 

Page 17: Inspur 4th generation data center

17 � 

High � rel iabi l ity � 

Power � distribution � system � 2N � structure � 

Refrigeration � system � N+1

� structure � 

Network � system � 2N � structure � 

Page 18: Inspur 4th generation data center

18 � 

D a t a �  c e n te r �  c o n s t r u c t i o n �  s t a n d a rd s �  �  �  �  � Learning � from � data � center � grading � methods � of � Microsoft � and � Green � Grid � and � according � to � modularization, � server � density � , � 

refrigeration, � UPS � and � PUE, � the � grading � standards � of � Inspur � data � center � are � as � follows: � 

No. �  Indicators �  1st � generation � (Mainframe � ) � 

2nd � generation � (Tower) � 

3rd � generation � (Rack) � 

4th � generation �  � (Modularization) � 

1 �  Modularization �  � 

Customized � computer � room � environment � and � supporting � system � to � provide � service � for � mainframe � 

N/A �  Rack-level � modularization � 

Computer � room � level � modularization � 

2 �  Cabinet � power �  N/A �  2KW~5KW �  5KW~20KW � 3 �  Cold � and � hot � air � channel �  �  �  Mixed �  �  Separate �  Enclosed � 4 �  UPS � efficiency �  �  80%~90% �  90%~94% �  ≥95% � 

5 �  Natural � cold � use � efficiency �  0% �  0% �  20%~75% � 

6 �  Air-conditioner � inlet � air � temperature �  20~24℃ �  20~24℃ �  26~30℃ � 

7 �  Waste � heat � recycling � efficiency �  �  None �  None �  10%~50% � 

8 �  Carbon � Usage � Effectiveness(CUE) �  �  None �  Measure �  �  Measure � and � improve � 

9 �  PUE �  �  2.0 � above �  1.5~2.0 �  1.1~1.5 � 

Page 19: Inspur 4th generation data center

19 �  Accord � with � state � 3 �  levels � protection � requirement � 

6-layer � physical � access � control � 

Computer � room � area � and � dynamical � area � physically � separated � 

Waterproof � and � moistureproof � 

Page 20: Inspur 4th generation data center

20 � 

� Nation-wide � unified � real-time � monitoring � 

� 

intelligent � monitoring �  � 

Page 21: Inspur 4th generation data center

21 �  Monitor � room � 

Page 22: Inspur 4th generation data center

22 � 

Chengdu � 

Jinan �  � 

Shanghai � 

Zaozhuang �  �  Binzhou �  � 

Lanzhou �  � 

Changzhi �  � 

Erdos � 

Ningb �  � 

Hefei �  � 

� Harbin � 

Nanjing �  � 

Hainan � 

Dezhou �  � 

Guizhou � 

Jining �  � 

Mianyang � 

Hohhot � 

Zhengzhou �  � 

Weihai � Liaocheng �  � 

Zibo �  � 

Heze �  � 

Shaoshan � 

Tempera-ture

� humidity � 

Picture �  Personnel � 

Business �  � Access � control � 

State � monitor ing � center � and � unif ied � monitor ing � 

Page 23: Inspur 4th generation data center

23 �  Application � current � situation � and � future �  � 

Government

Enterprise Public Society

Page 24: Inspur 4th generation data center

24 �