MODEL: UF0505 G AS FIRED D IRECT V EN T FIREPLACE IN SERT S/ N 650000 AN D UP ARCHGARD FIREPLACE PRODUCTS 7116 B eatty D rive M issio n, B C V 2V 6B 4 Canad a 200- U505- 02 Feb ruary 12, 2019 English and French Installatio n M anuals availab le thro ugh yo ur lo cal d ealer o r visit o ur web site at: www.archgard.com Les m anuels d ' installatio n en anglais et en f rança is so n d ispo nib les chez vo tre d é taillant lo cal o u en visitant no tre site web : www.archgard.com INSTALLER: LEAV E T HIS M AN UAL W IT H T HE APPLIAN CE. CONSUMER: RET AIN T HIS M AN UAL FOR FUT URE REFEREN CE. This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. INSTALLATION, OPERATION, AND MAINTENANCE MANUAL DR QRW VWRUH RU XVH JDVROLQH RU RWKHU ÀDPPDEOH YDSRUV RU liq uid s in the vicinity o f this o r any o ther appliance. WHAT TO DO IF YOU SMELL GAS: D o no t try to light any appliance D o no t to uch any electrical switch; d o no t use any pho ne in y o ur b uild ing Im m ed iately call yo ur gas supplier f ro m a neighb o rs pho ne. Fo llo w the gas suppliers instructio ns ,I \RX FDQ QRW UHDFK \RXU JDV VXSSOLHU FDOO WKH ¿UH d epartm ent ,QVWDOODWLRQ DQG VHUYLFH PXVW EH SHUIRUPHG E\ D TXDOL¿HG installer, service agency o r the gas supplier. WARNING: If the inf o rm atio n in this m anual is no t f o llo wed H[DFWO\ D ¿UH RU H[SORVLRQ PD\ UHVXOW FDXVLQJ SURSHUW\ d am age, perso nal inj ury o r lo ss o f lif e. Inspiration 29MV Gas Fireplace Energy Efficiency Rating 71.19% Based on CSA P.4.1-15

Upload: others

Post on 15-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

MODEL: UF0505 G AS FIRED D IRECT V EN T

FIREPLACE IN SERTS/ N 650000 AN D UP

ARCHGARD FIREPLACE PRODUCTS7116 B eatty D rive

M issio n, B C V 2V 6B 4 Canad a200- U505- 02Feb ruary 12, 2019

English and French Installatio n M anuals availab le thro ugh yo ur lo cal d ealer o r visit o ur web site at: www.archgard.comLes m anuels d ' installatio n en anglais et en f rança is so n d ispo nib les chez vo tre d é taillant lo cal o u en visitant no tre site web : www.archgard.com

INSTALLER: LEAV E T HIS M AN UAL W IT H T HE APPLIAN CE.CONSUMER: RET AIN T HIS M AN UAL FOR FUT URE REFEREN CE.

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

D liq uid s in the vicinity o f this o r any o ther appliance.

WHAT TO DO IF YOU SMELL GAS:

• D o no t try to light any appliance• D o no t to uch any electrical switch; d o no t use any pho ne in

y o ur b uild ing• Im m ed iately call yo ur gas supplier f ro m a neighb o rs pho ne.• Fo llo w the gas suppliers instructio ns•

d epartm ent

installer, service agency o r the gas supplier.

WARNING: If the inf o rm atio n in this m anual is no t f o llo wed

d am age, perso nal inj ury o r lo ss o f lif e.

Inspiration 29MV

Gas Fireplace Energy Efficiency Rating

71.19%Based on CSA P.4.1-15

Page 2: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

2

TABLE OF CONTENTS

1.0 Introduction 32.0 Safety Information 43.0 Technical Information 5

1 A C 52 C 5 S 5 A 5

4.0 Rating Plate 65.0 Installation Checklist 76.0 Appliance Overview 8

1 R P L 86.2 Appliance Overview 86.3 Leveling the Appliance 8

A C 9 C 9

7.0 Electrical Connections 108.0 Appliance Dimensions 119.0 Minimum Opening Dimensions 12

9 1 F B F 139 2 R M F 14

10.0 Clearances to Combustibles 1510 1 M C 1510 2 S C 1510.3 Hearth Clearances 16

11.0 Gas Connections 1711 1 C P 17

12.0 Conversion Kit Instructions 1812.1 Prepare the Fireplace 1812 2 P C 1812 C C 1912 C G V 19

13.0 Venting Instructions 201 1 A T 211 M M V R 231 U C C A 24

14.0 Barrier Screen Installation 2515.0 Glass Door Installation 26

1 1 Y G B 26

16.0 Surround Installation 271 1 B F P 28

17.0 Firebox Liner Installation 291 1 M P R 291 2 B P 301 R G 31

18.0 Media Installation 3218 1 L S UF0 0 32

19.0 Operation 3619 1 B L 3619.2 First Fire 3619 L 39

20.0 Maintenance 4020 1 C R M 4020 2 S U 4120 C O P 4120 C A P 4120 A P A 4220 S 4320 R B 4420 8 R B 4520 9 R P 4620 10 R P 4720 11 R O F S

C 4820 12 R V 4920 1 R O F T

S 5020 1 R O F 5120 1 T 52

21.0 Frequently Asked Questions 5422.0 Replacement Parts List 55Warranty Information 57

10 Y L 57L 58

Page 3: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

3

General Information1.0 IntroductionT Y C A G F

T UF0505 D V

service.

S UF0505 are:

• C T T D V

• E T D V

• A F T

• S C T 1 18

• O A S A A D

• R C C

Y chair.

F M N : UF0505 S N :

D :

T G U F : • N G • P

D N A :

D P N :

P :

Page 4: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

4

General Information2.0 Safety InformationCautionFOR YOUR SAFETY D A

T

P

N

P

T

F

A

SafetyD

C

Y T A T

D

C

D D

WARNING: D R

A

R T M

D

California Proposition 65 Warning: T C M S C

F P

E A G F B

T C Section 5.0

Any alteration to the product that causes carbon or soot deposits that results in any damage or requires cleaning is not the responsibility of the manufacturer.

Page 5: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

5

General Information3.0 Technical Information3.1 Appliance CertificationT A L USA C

ANS 21 88 201 CSA 2 201 V G F CSA 2 1 201 G F A U A CSA P 1 1 CSA 22 2 N M1988 R201

T A Section 4.0.

Commonwealth of Massachusetts: T M 2 8 CMR 00 A C : G1 0 19 8 :

P Archgard Industries Ltd

3.2 Installation CodesT T

N F G C ANS 22 1 NFPA US C CANCGA B1 9 1 C E N E ANSNFPA N 0 198 US C C E C CSA C22 1

T P

We recommend that our gas hearth products be installed and serviced by professionals who are certified in the U.S. by the National Fireplace Institute® (NFI) as NFI Gas Specialists.

3.3 Specifications

Natural Gas (NG) Propane (LP)

Manifold Pressure 1 1 8 C 0 2 0 9 P 2 9 11 0 C 0 2 P

Min. Supply PressureMax Supply Pressure

0 C 1 2 P1 0 C P

12 0 C 2 98 P1 0 C P

Orifice Size DMS 2 1 DMS 1 0

Input Rating 1 00 1 00 BTU 1 9 2 1 000 28 00 BTU 8

P.4 Fireplace Efficiency (FE) 71.19% 71.19%

P.4 Steady State Efficiency 78.95% 78.95%

Electrical Rating 120 VAC 0 2 A

Gas Control S T 820 N

Altitude 0 00 0 1 2 M

Primary Air Opening 1 8 1 OPEN FULLY OPEN

3.4 High Altitude Installation 00 1 2 M

N F G C ANS 22 1 NFPA US C CAN CGA B1 9 1 C

Page 6: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

6

General Information4.0 Rating Plate

SAMPLE

9-1/4

12 ” SHEET

SHEET

SHEET

SHEET

February 12, 2019

UF0505 RATING PLATEMaterial - Class III

Black Letters on silver Mylar background

MODEL: UF0505 (SIT 820 Nova)

DO NOT REMOVE THIS LABEL

LISTED VENTED GAS FIREPLACE HEATER and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES. Tested to: ANSI Z21.88-2017 / CSA 2.33-2017, CSA 2.17-2017, CSA P.4.1-15, and CSA 22.2 No.3-M1988 (R2014). This vented gas fi replace heater

is not for use with air fi lters. Certifi ed for use in both CANADA and USA.

VENTED GAS FIREPLACE HEATER-NOT FOR USE WITH SOLID FUEL.Manufactured as Natural Gas

NG LPG

Input rating 17,500 - 31,500 BTU/hr(5.1 - 9.2 kW)

15,000 - 28,500 BTU/hr(4.4 - 8.3 kW)

Manifold Pressure 1.1 - 3.8 in. W.C. (0.2 - 0.94 kPa) 2.9 - 11.0 in. W.C. (0.7 - 2.7 kPa)

Orifi ce size #37 DMS (2.64 mm dia.) #51 DMS (1.70 mm dia.)

Supply pressure (Min - Max) 5.0 - 14.0 in. W.C. (1.2 - 3.5 kPa) 12.0 - 14.0 in. W.C. (2.98 - 3.5 kPa)

Burner Primary Air Setting 1/8” (3.175 mm) Open 100% Open

Altitude 0 - 4500 ft (0 - 1372 m) 0 - 4500 ft (0 - 1372 m)

Electrical rating 120 VAC, 60 Hz, less than 2 A.

P.4.1 Fireplace Effi ciency (FE) 71.19%

Optional Fan Kit Part no. UA9004 optional fan kit may be used

Replacement fan Part no. RF-305-0624 fan for optional fan kit UA9004

Keep burner and control compartment clean. See Instructions accompanying the heater.

Optional fuel conversion kit : See Manual

Minimum opening Dimensions: 28���”(724 mm)W x 22”(559 mm)H x 17.5” (445 mm)D

Minimum Chimney Flue Size:4” (100 mm) x 7” (176 mm)

Minimum clearances to Combustibles:Sides from glass door frame: 7” (178 mm)

Mantle: max 8” (203 mm) at min 35” (889 mm) from bottom of applianceSee Manual for additional dimensions and clearances

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. Electrical connections and grounding must be in accordance with local codes, if any; if none, follow the current CAN/CSA C22.1 in Canada and ANSI/NFPA 70 in the US. This appliance is certifi ed for installation in a bedroom or a bed sitting room. This appliance is only for use with the gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner’s manual for details. This appliance is not convertible with other gases, unless a certifi ed kit is used.

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualifi ed installer, service agency, or the gas supplier. This appliance must be properly connected to a Direct Vent venting system in accordance with the manufacturer’s installation instructions.

WARNING: Failure to install this appliance per the manufacturer’s instructions or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury.

WARNING: Do not operate the appliance until all sections have been assembled and installed in accordance with the manufacturer’s instructions.

WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.

Only doors certifi ed with the appliance shall be used.For use only with barrier part # URP-890-0200. Follow installation instructions.

Made in Canada by:Archgard Industries Ltd.7116 Beatty Dr., Mission, B.C.

Feb 2019 303-6216-02

NE PAS ENLEVER CETTE ÉTIQUETTE

RADIATEUR VENTILE, CIRCULATEUR DU TYPE VENTILATEUR. Testée selon les normes : ANSI Z21.88-2017 / CSA 2.33-2017, CSA 2.17-2017, CSA P.4.1-15 et CSA 22.2 No.3-M1988 (R2014). Ne pas utiliser de fi ltre à air avec ce foyer au gaz à évacuation.

Certifi é pour utilisation dans le Canada et les ÉTATS-UNIS.

FOYER AU GAZ À ÉVACUATION. NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.Fabriqué comme gaz naturel.

NG LPG

Entrée assignée 17 500 - 31 500 BTU/hr(5,1 - 9,2 kW)

15 000 - 28 500 BTU/hr(4,4 - 8,3 kW)

Pression d’admission 1,1 - 3,8 po. W.C. (0,2 - 0,94 kPa) 2,9 - 11,0 po W.C. (0,7 - 2,7 kPa)

Dimension de l’orifi ce #37 DMS (2,64 mm dia.) #51 DMS (1,70 mm dia.)

Pression d’alimentation (Min - Max) 5.0 - 14.0 po W.C. (1,2 - 3,5 kPa) 12.0 - 14.0 po W.C. (2,98 - 3,5 kPa)

Réglage de l’air primaire du brûleur 1/8” (3,175 mm) Ouvrir 100% Ouvrir

Elevation 0 - 4500 ft (0 - 1372 m) 0 - 4500 ft (0 - 1372 m)

Tension électrique 120 V, 60 Hz, Moins que 2 A.

P.4.1 Effi cacité du foyer (FE) 71.19%

Kit de ventilateur en option Le kit de ventilateur optionnel peut être utilisé (référence UA9004)

Ventilateur de remplacement Le ventilateur RF-305-0624 doit être utilisé

Maintenir propres le brûleur et le compartiment de commande. Voir les instructions relatives à l’installation et au fonctionnement qui accompagnent le radiateur.

Trousse de conversion de combustible optionnel : Voir le manuel

Minimales dimensions d’ouverture:28��� po (724 mm)W x 22 po (559 mm)H x 17.5 po (445 mm)D

Cheminée minimale de fumée:4 po (100 mm) x 7 po (176 mm)

Minimales entre l’appareil et les combustibles:Côtes: 7 po (178 mm)

Manteau: max 8po (203 mm) à min 35 po (889 mm) du bas de l’appareilVoir le manuel pour les dimensions et les dégagements supplémentaires

Il faut que cet appareil soit installé selon les codes locaux, s’il y en a; sinon, suivre le CSA-B149.1 actuel au Canada et ANSI Z223.1 aux É.-U. Il faut que le raccordement électrique et la mise à la masse soient en conformité avec les codes locaux, s’il y en a; sinon, suivre le CAN/CSA C22.1 actuel au Canada et ANSI/NFPA 70 aux É.-U. Cet appareil est certifi é pour l’installation dans une chambre à coucher ou une pièce qui sert de chambre. Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l’utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d’’autres gaz sauf si une trousse de conversion certifi ée est fournie. AVERTISSEMENT: Une installation, un réglage, une modifi cation, une réparation ou un entretien mal eff ectué peut causer des

dommages atériels ou des blessures. Voir la notice de l’utilisateur qui accompgne l’appareil. Pour de l’aide ou des renseignements supplémentaires, consultez un installateur, un technicien agréé ou le fournisseur de gaz. Cet appareil doit être corectement raccordé à un système d’évacuation direct, conformément aux instructions du fabricant.

AVERTISSEMENT : Risque de dommages ou de blessures si l’appareil n’est pas installé selon les instructions du fabricant ou si des pièces autres que celles spécifi quement approuvées avec cet appareil sont utilisées.

AVERTISSEMENT : Ne pas utiliser l’appareil tant que toutes les sections n’ont pas été assemblées et installées selon les instructions du fabricant.

AVERTISSEMENT : Si cet appareil fonctionne sans être raccordé à un système d’évacuation correctement installé et entretenu, ou si le système d’évacuation es modifi é, il peut en résulter un empoisonnement au monoxyde de carbone et la mort.

SEULES DES PORTES CERTIFIÉES POUR CET APPAREIL DOIVENT ÊTRE UTILISÉES.Utiliser uniquement avec l’écran no URP-890-0200. Suivre les instructions d’installation.

Fabrique au Canada par:Archgard Industries Ltd.7116 Beatty Dr., Mission, B.C.Feb 2019 303-6216F-02

MODÈLE: UF0505 (SIT 820 Nova)

MANUFACTURE DATE: 2018 2019 2020 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC date de fabrication: 2018 2019 2020 jan fév mar avr mai jun jul août sep oct nov dec

Page 7: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

7

Installation5.0 Installation ChecklistThis standard installation checklist is to be used by the installer in conjunction with, not instead of, the instructions contained within this installation manual.

Customer: Date Installed:

Install Address: Location of Fireplace:

Installer:

Solid Fuel Zero Clearance Install: (Section 9.1) YES NO IF NO, WHY NOT?

Venting: (Section 13.0) YES NO IF NO, WHY NOT?

V

V clearances.

S

T

D

Wiring / Electrical: (Section 7.0) YES NO IF NO, WHY NOT?

C 110 120

U

Gas: (Section 11.0) YES NO IF NO, WHY NOT?

P

L

Finishing: YES NO IF NO, WHY NOT?

O

C

M

Figure 9.0.02

Appliance Setup: YES NO IF NO, WHY NOT?B

M

D

Comments:

Page 8: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

8

Installation6.0 Appliance Overview6.1 Rating Plate Location

Figure 6.1.01:

6.2 Appliance OverviewT

T

Note: T

L Figure

6.2.01.

6.3 Leveling the ApplianceT UF0 0 T

L

Figure 6.2.01:

Figure 6.3.01:

T S

F B

R B

S

L S R S

C A C

Page 9: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

9

Installation6.4 Accessing the ControlsT UF0 0

Figure 6.4.01.

Figure 6.4.01:

6.5 Identifying the ControlsSee Figure 6.5.01 S O Section 19.0

Figure 6.5.01

Speed Control for Optional Fan

Main Burner On/Off Switch Pilot IgniterValve On/Pilot/Off

KnobValve High/Low Flame Modulation

Optional Fan

Page 10: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

10

Installation7.0 Electrical ConnectionsT UF0505 A UA9004

D

CAUTION: L

NOTE: T N E C ANS NFPA 0 C E CSA C22 1

B :• F D C S Section 6.4

T :

Step 1: R wiring. See Figure 7.0.02

Thermostat / wall switch wire tableRecommended Maximum Lead Length for two wires.

S M L1 GA 0 F 1 2 M1 GA 2 F 9 M18 GA 20 F 9 M20 GA 12 F M 22 GA 9 F 2 M

Figure 7.0.01: Figure 7.0.02:

Step 2: R A

Figure 7.0.03:

Step 3: C

Figure 7.0.04:

Note: See Figure 20.6.01

Note:

Page 11: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

11

Installation8.0 Appliance Dimensions

27.906

15.922

25.122

26.948

19.397

2.551

5.000

5.000

37.906

28.5 17.794

17.305 18.265

4.414

.960

1:10

SIZE DWG. NO.

AREV.

SHEET 2 OF 4WEIGHT:

UF0505FINISH

MATERIAL

DIMENSIONS ARE IN INCHESTOLERANCES:

FRACTIONAL 1/32"TWO PLACE DECIMAL .015"THREE PLACE DECIMAL .005"

ALL BENDS ARE ASSUMEDTO BE 90 UNLESS NOTED

OTHERWISE.

CHECKED

DRAWN AFDATENAME

A

10/24/2018UF0505

LOG BURNER

PRO

PRIE

TARY

AN

D C

ON

FIDE

NTIA

L

U:\E

NG

INEE

RIN

G\P

RODU

CT\

UNITS

\IN

SPIR

ATIO

N 2

9\UF

0505

\UF0

505

Wed

nesd

ay, O

ctob

er 2

4, 2

018

9:24

:10

AM

SCALE

Front View

2.073

7.638 6.678

.960 2.926 x 2

21.948

15.462

11.770

1:12

SIZE DWG. NO.

AREV.

SHEET 3 OF 4WEIGHT:

UF0505FINISH

MATERIAL

DIMENSIONS ARE IN INCHESTOLERANCES:

FRACTIONAL 1/32"TWO PLACE DECIMAL .015"THREE PLACE DECIMAL .005"

ALL BENDS ARE ASSUMEDTO BE 90 UNLESS NOTED

OTHERWISE.

CHECKED

DRAWN AFDATENAME

A

10/24/2018UF0505

LOG BURNER

PRO

PRIE

TARY

AN

D C

ON

FIDE

NTIA

L

U:\E

NG

INEE

RIN

G\P

RODU

CT\

UNITS

\IN

SPIR

ATIO

N 2

9\UF

0505

\UF0

505

Wed

nesd

ay, O

ctob

er 2

4, 2

018

9:24

:10

AM

SCALE

Left Side

2.073

7.638 6.678

.960 2.926 x 2

21.948

15.462

11.770

1:12

SIZE DWG. NO.

AREV.

SHEET 3 OF 4WEIGHT:

UF0505FINISH

MATERIAL

DIMENSIONS ARE IN INCHESTOLERANCES:

FRACTIONAL 1/32"TWO PLACE DECIMAL .015"THREE PLACE DECIMAL .005"

ALL BENDS ARE ASSUMEDTO BE 90 UNLESS NOTED

OTHERWISE.

CHECKED

DRAWN AFDATENAME

A

10/24/2018UF0505

LOG BURNER

PRO

PRIE

TARY

AN

D C

ON

FIDE

NTIA

L

U:\E

NG

INEE

RIN

G\P

RODU

CT\

UNITS

\IN

SPIR

ATIO

N 2

9\UF

0505

\UF0

505

Wed

nesd

ay, O

ctob

er 2

4, 2

018

9:24

:10

AM

SCALE

Right Side

27.906

15.922

25.122

26.948

19.397

2.551

5.000

5.000

37.906

28.5 17.794

17.305 18.265

4.414

.960

1:10

SIZE DWG. NO.

AREV.

SHEET 2 OF 4WEIGHT:

UF0505FINISH

MATERIAL

DIMENSIONS ARE IN INCHESTOLERANCES:

FRACTIONAL 1/32"TWO PLACE DECIMAL .015"THREE PLACE DECIMAL .005"

ALL BENDS ARE ASSUMEDTO BE 90 UNLESS NOTED

OTHERWISE.

CHECKED

DRAWN AFDATENAME

A

10/24/2018UF0505

LOG BURNER

PRO

PRIE

TARY

AN

D C

ON

FIDE

NTIA

L

U:\E

NG

INEE

RIN

G\P

RODU

CT\

UNITS

\IN

SPIR

ATIO

N 2

9\UF

0505

\UF0

505

Wed

nesd

ay, O

ctob

er 2

4, 2

018

9:24

:10

AM

SCALE

Top

Dimensions Shown with Surround Option

UA5050.

Page 12: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

12

Installation9.0 Minimum Opening Dimensions

T S Figure 9.0.02.

C Section 9.1.

T T

WARNING: T

AVERTISSEMENT: C

0 012

Figure 9.0.02:

A B

C

D

E

F

G

Reference DimensionA 22 9 B 11 289 C 1 D 2 1 E 18 0 F 28 2 G 107.76°

Figure 9.0.01:

WARNING: F

Page 13: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

13

Installation9.1 Factory Built FireplacesThe following information applies to Factory Built (metal) Wood-Burning Fireplace installations:

T A 1 1 2 8 1

T

T A B

T C D E G F

T S Figure 9.0.02 C J

T

The metal floor of the firebox may be removed only if the following is strictly adhered to.

T J Under no circumstance can it be placed directly on a combustible material.

AC

D

G

I

F

H

J

E

B

Figure 9.1.01: S F B B Fireplace.

Figure 9.1.02: Removing the Metal Floor

REMOVE THIS SECTION OF METAL FLOOR

REMOVE THIS SECTION OF METAL FLOOR

REMOVE THIS SECTION OF METAL FLOOR

F F

R

0 M Clearance

Page 14: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

14

Installation9.2 Refacing a Masonry FireplaceUsing Steel Studs and Cement Board on Wood FireplacesB

WARNING: O A WARNING: L

T The insert must be moved outward so that the face of the fireplace is flush with

the finishing material.

Using Steel Studs and Cement Board on Wood Fireplaces Brick / rock facing may be removed and replaced with non-combustible materials like steel studs and cement board. Only the facing material can be removed. All other masonry material must not be cut out, chipped away or removed. The area between the masonry and the cement board, must be sealed so that no heat can enter the open space between the masonry of the wood fireplace and the re-facing material. The insert must be pulled out so the face of the fireplace will be flush with the finishing materials.

Steel Studs

Original “Zero Clearance” Wood Burning / Masonry

fireplace

Sealant to be used to avoid heat from entering enclosure

Sealant

Note: all areas of the wood burning firebox must be sealed to avoid heat entering any cavities.

Use Cement Board on front and around Steel Stud enclosure and where needed to

ensure no heat enters any cavities.

Figure 9.2.01:

O B M F

Page 15: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

15

Installation10.0 Clearances to CombustiblesWARNING: F

CAUTION: T

Figure 10.1.01

10.1 Mantel Clearances

10.2 Sidewall Clearances

Figure 10.2.01

M 1 8

M E

10"

2

12"

08

14"

16"

0 18

" 2

20"

08

7"1 8

7"1 8

21"

Page 16: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

16

Installation10.3 Hearth Clearances

16" 0

Figure 10.3.02

Non CombustibleZone

16”

Non CombustibleZone

16”

31 3/4”

3" 2

C

T N C

N

N C

A 2 T

A 2 1 0

WARNINGF

NOTEA

16" 0

Non Combustible

Zone

30.5"

Figure 10.3.01

Page 17: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

17

Installation

11.0 Gas ConnectionsB

T S Section 4.0 Section 6.1 appliance’s gas valve.

A All gas connections must be checked for gas leaks.

T

S

CAUTION: T 1 2 P T

1 2 P F S

Natural Gas Pressure Settings:T C 1 2 P 1 C P T DMS 2

ELEVAT ON NPUT RAT NG0 00 0 1 2 M 1 00 BTU 9 2

00 1 2 M 1 00 BTU 9 2 1000 0 M P

Propane Pressure Settings:T 12 C 2 98 P 1 C P T 1 DMS 1 0

ELEVAT ON NPUT RAT NG0 00 0 1 2 M 28 00 BTU 8

00 1 2 M 28 00 BTU 8 1000 0 M P

11.1 Clocking ProcedureIMPORTANT: T E NPUT RAT NG S OULD AL AYS BE C EC ED EN F RST F R NG T S APPL ANCE

B L 1 C 1 C BTU

BTU N : T 1 2 2

A T

Rough Calculation Equation:

1 / Time to burn 1ft³ of gas in seconds / 3600 x gas caloric value in BTU/ft³ = Rating

Page 18: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

18

Installation

12.0 Conversion Kit InstructionsIMPORTANT: T N LP

WARNING: T

T T

R

IMPORTANT: F 00 1 2

T NUMBERS: UA9005 LP UA9006 N GT NCLUDES:

• G 0 0128 • B 01 00 8 1 1 DMS LPG 01 00 8 DMS NG• S • S T 820 V

WARNING: SHUT OFF GAS SUPPLY AND ELECTRICAL POWER TO FIREPLACE SHUT OFF GAS SUPPLY BEFORE DISCONNECTING ELECTRICAL POWER

12.1 Prepare the FireplaceR

R

S R 1 2 R

U D

12.2 Pilot ConversionU 1 1 S

T

Figure 12.1.01:

Figure 12.2.01:

WARNING: Installation should be carried out in a clean environment.WARNING: This modulating conversion kit must ONLY be applied as part of a conversion kit supplied by the APPLIANCE

MANUFACTURER.WARNING: Correct operation of the system cannot be guaranteed if the conversion kit or valve has been dropped or has

sustained a strong impact.INSTALLER NOTICE: These instructions must be left with appliance.

Page 19: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

19

Installation

12.4 Complete the Conversion• R • T • T • C all

T S Section 11.0 V F T

C Section 11.1 A

• T • A S Section 6.1 • C • R

S

12.3 Convert the Gas ValveP S Figure 12.2.03

T S Figure 12.2.04

O S T 20 T

A B C

E D

NG

LP 1 1 RED

Figure 12.2.02:

Figure 12.2.03:

Figure 12.2.04:

V

Figure 12.2.05:

Figure 12.3.01:

Page 20: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

20

Installation

13.0 Venting InstructionsWARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance.

CAUTIONO

T T

T 10 0 M 0 12 2 M M

T A F L

T E F L

The Air intake and Exhaust connections are marked on the gas appliance. See Figure 13.0.01.

DO NOT REVERSE THESE CONNECTIONS

CAUTIONT

Figure 13.0.01: E

E

Figure 13.0.02: Figure 13.0.03:

Sealing the Vent

S DO NOT U M P

Page 21: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

21

Installation

13.1 Approved Terminations

Archgard Venting ComponentsVent Component Part Number

V T 999 NS T

0 A F L 999 NS FL 0

0 A F L 999 NS FL 0

A

Figure 13.0.04: Figure 13.0.05:

Figure 13.0.06:

Page 22: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

22

Installation

Third Party Venting ComponentsBDM Selkirk Duravent ICC Amerivent

F 10 95270310 AFE10 0 N A N A AL E10

F 2 95270325 AF 2 L DFA 2 N A 1730250

F 0 95270330 N A N A N A N A

F 95270335 AF L DFA TC AL 1730350

F 0 95270350 N A N A TC AL 0 AL E 0

F C 95090390 AF FC DFA FC TM CFAA C

8 C Cap 940285 DT VC DVA VC TM SVT N A

8 C L P Cap 940206LP DT VT N A N A DVC

C 8 C A 940113364 DT CBT

DT AAC DVA G TM CTA DCAT

S R P94000339 N A DVA V G TM SVTS N A

S Rectangular N A N A N A TM CTS N A

C V T F M C

9 20 0 S 1604645 DVA CL TM AL DV N

C D V F B R

V T FN A N A DVA CL FB TC AL TM VT

TM VTP N A

C R V T 9 00 S 1604643 N A TM VT DVCC

C V T R B 9 00 2RD N A N A TM VT TM VTP N A

C V T S B 9 00 S N A N A TM VT TF MFR TF

MFC TF MF N A

C M F R V T N A N A N A TF CTF

TF CTFC N A

C S V T

9 00 9400330808SS N A N A N A N A

C R V T 940034EC26SS N A N A TM CT N A

C M F R V T N A N A N A TF CTF

TF CTFC N A

P C F N A N A N A TM VTP N A

A C F C N A DT CFC DVA ADF N A N A

C S D C 9 00 DBL N A N A N A N A

ATTENTIONNO OTHER VENTING SYSTEM OR COMPONENTS MAY BE USED.

P F

Page 23: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

23

Installation13.3 Min/Max Vent RunInstructions for installing venting and terminations (see list for approved venting and terminations).Install the termination cap being sure to provide sufficient space (around and on top) so you do not impede the flow of air, both into and out of the cap. This cap is only to be used for non combustible installations. Do not recess into the top of the chimney.1. M Air Intake2. M Exhaust3. P 4. 5. S Air Intake Air Intake

DO NOT USE SILICONE.6. S Exhaust Exhaust

DO NOT USE SILICONE.7. S “Air Intake” Air Intake

DO NOT USE SILICONE.8. S Exhaust Exhaust

DO NOT USE SILICONE.9. C DO NOT USE SILICONE. Use of silicone sealants voids the

warranty of the pilot assembly.NOTE: T

T 100 1 8

Figure 13.3.01:

Page 24: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

24

General Information13.4 Using a Co-linear to Coaxial Adapter

Front view of DV Insert

Exhaust

Fresh air intake

Termination

Roof Flashing

3” (76 mm) Flex Liner

Sealed Flashing

Coaxial pipe ( min. 4” exhaust - 6 5/8” Intake)

Colinear to coaxial adaptor

Blown InsulationBlown Insulation

Max. 6 ft or 50% of the total vent run, which ever is shorter

Min. 18”

Min 10 ft

Ceiling

Roof

Must maintain 1” form coaxial pipe to insulation and combustible

Figure 13.4.01:

T

WARNINGT T

N F G C ANS 22 1 NFPA US C CANCGA B1 9 1 C E N E ANS NFPA N 0 198 US C C E C CSA C22 1

• T 0

• A

• T 10

• A 1

• T 18

C

Page 25: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

25

Installation

14.0 Barrier Screen Installation

P N : URP-890-0200

Step 1: A

Step 2: A T

Step 3: D

Step 4: S

Figure 14.0.01: Figure 14.0.02:

Figure 14.0.03:

Figure 14.0.04:

Top Hook

Bottom Hook

Page 26: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

26

Installation

15.0 Glass Door InstallationWARNING: D R

D B

15.1 If Your Glass Breaks

: URP 890 0000

• R Section 14.0• R • R • R

Note: NE T

Warning: O D

Step 1: S Figure 15.0.01.

Step 2: R Step 3: R P

Figure 15.0.01:

Figure 15.0.02: Figure 15.0.03:

Note: T

Page 27: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

27

Installation

16.0 Surround Installation• M • S B

• A M

• N

37.906

5.000 5.000 5.000

21.750 26.750

27.906

0.960

2.327

1.790

S M T

1:8

SIZE DWG. NO.

AREV.

SHEET 1 OF 1WEIGHT:

UF0505FINISH

MATERIAL

DIMENSIONS ARE IN INCHESTOLERANCES:

FRACTIONAL 1/32"TWO PLACE DECIMAL .015"THREE PLACE DECIMAL .005"

ALL BENDS ARE ASSUMEDTO BE 90 UNLESS NOTED

OTHERWISE.

CHECKED

DRAWN AFDATENAME

A

18/10/24UF0505

LOG BURNER

PRO

PRIE

TARY

AN

D C

ON

FIDE

NTIA

L

R:\E

NG

INEE

RIN

G\P

RODU

CT\

UNITS

\IN

SPIR

ATIO

N 2

9\UF

0505

\UF0

505

Wed

nesd

ay, O

ctob

er 2

4, 2

018

12:

:08

PM

SCALE

Figure 16.0.01:

UA 0 0 S

Page 28: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

28

Installation

16.1 Bottom Filler Plate

A B F P S

Figure 16.1.01: Align the plate. Figure 16.1.02: S

Figure 16.1.03: V

U

Page 29: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

29

Installation

17.0 Firebox Liner Installation17.1 Masking Plate RemovalB

B :• Ensure the gas supply is turned OFF and disconnect the power supply• R Section 14.0• R G D Section 15.0

Step 1: R 2

Figure 17.1.01:

Step 2: R A

Figure 17.1.02:

Page 30: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

30

Installation17.2 Brick Panel InstallationT

P A A D

B :• Ensure the gas supply is turned OFF and disconnect the power supply• R Section 14.0• R G D Section 15.0

Step 1: R P R L T

Step 2: P U

panel in place.

Step 3: A

Step 4: P S

Figure 17.2.01: Figure 17.2.02:

Figure 17.2.03: Figure 17.2.04:

E T

secure the clip in place

R

Figure 17.2.05:

Page 31: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

31

Installation

17.3 Reflective Glass InstallationT E F R C G

P A A D B

B :• Ensure the gas supply is turned OFF and disconnect the power supply• R Section 14.0• R G D Section 15.0

Step 1: U

Step 2: C L R T

D

Figure 17.3.01: Figure 17.3.02:

Step 3: S L S

R T

Figure 17.3.03:

Step 4: U T

R

Figure 17.3.04: Figure 17.3.05:

Step 5: T B

F B

T U B R N B

Figure 17.3.06:

Page 32: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

32

Installation

18.1 Log Set - UF0505

WARNINGF

T A C

A P A A D

G

CAUTION: DO NOT

NOTE: T D

18.0 Media Installation

Step 1: A L 1 S

Step 2: P L 2 A

Figure 18.1.01: Log Pins

Figure 18.1.02: Figure 18.1.03:

Page 33: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

33

InstallationStep 3: L S

Step 4: R L L P L

pin.

Figure 18.1.04: Figure 18.1.05:

Step 5: R L L 1 T L L

Figure 18.1.06:

Step 6: R L L 1 T L L 2

Figure 18.1.07:

Step 7: R L L

Figure 18.1.08:

Page 34: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

34

InstallationEmber Placement

IMPORTANT E DO NOT F

A B E U

P T

B L L 1

Figure 18.1.09: Figure 18.1.10:

Figure 18.1.11: Figure 18.1.12:

Do Not Block Pilot Area

A

T

Final Install

Figure 18.1.13: Figure 18.1.14:

Page 35: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

35

Installation

Part # Item Description Qty Item # Item Description Qty10 U 00 01 UF0 00 1 10 1 L S 1 Set 10 U 00 1 L U R 110 U 00 1 L 1 M R 1 10 U 00 1 L U L 110 U 00 2 L 2 F L 1 10 U 00 1 L M T 110 U 00 L F R 1 10 0020 B E 2 110 U 00 L M R 1 10 0019 P E 1 1

T C

A P A D

G

WARNING N T

WARNING T UF0 00 1 UF0 0 DO NOT UF0 10 1

Figure 18.1.13:

Page 36: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

36

Operation

19.0 Operation19.1 Before Lighting

19.2 First Fire T

C R

OFF S C Section 20.1

B

:

D

WHAT TO DO IF YOU SMELL GAS:• D • D • F •

1. BEFORE LIGHTING B

2. IF YOU SMELL GAS 3. D

E A G F A

T :

1. P 2. C Section 11.0 3. 4. C 5. T ON A

F RST F RE

U Section 5.0

Note: A

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not operate the appliance with the glass front removed, cracked or broken. Replacement of broken glass should be done by a licensed or qualified service person.

Page 37: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

37

Operation

Step 1: M O O OFF

Figure 19.2.01:

OFF

Step 2: T OFF

Figure 19.2.02:

Step 3: G P LOT

Figure 19.2.03:

Step 4: P P 0

Figure 19.2.04:

C 0

Step 5: 0 0 ON

Figure 19.2.05:

Step 6: F ON T

Figure 19.2.06:

ON

Before you begin:• Read the instructions fully before starting• Ensure the fireplace is off and cool before lighting the pilot• F Section 6.4

Igniter

Page 38: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

38

OperationStep 7: T

Figure 19.2.07:

Operating the Optional Fan

Step 1: T

Figure 19.2.08:

1 T Section 6.4 T

WARNING:NEVER operate this appliance with the barrier screen

removed.

CL C

O

On

Step 2: T T

High L

Figure 19.2.09:

Before you begin:• Read the instructions fully before starting• Ensure the fireplace is off and cool before starting• F Section 6.4

WARNING: NEVER operate this appliance with the barrier screen removed.

Note: O

Page 39: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

39

Operation

19.3 Lighting InstructionsT S Section 6.1

9-1/4

11-7/8” SHEET

SHEET

SHEET

SHEET

July 31, 2018

INSTRUCTION LABEL

6 Each Red Bars on Silver background with Black lettering.

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire of explosion may result causing property damage, personal injury or loss of life.AVERTISSEMENT: Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.

A. This appliance has a pilot which must be lighted by manual spark igniter. When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any electrical switch; do not use any phone in your

building. • Immediately call your gas supplier from a neighbor’s phone. Follow

the gas supplier’s instructions• If you cannot reach your gas supplier, call the fire department.C. Use only your hand to push in or turn the gas control knob. Never use

tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

1. STOP! Read the safety information above on this label.2. Set the wall switch to “OFF”. 3. Turn off all electric power to the appliance.4. Open lower louvers or remove trim.5. Press slightly and turn the control knob clockwise to the “OFF”

position. Open gas isolation valve.6. Wait 5 minutes to clear out any gas. Then smell for gas, including

near the floor. If you smell gas, STOP! and follow “B” in the safety information above (and to the left) on this label. If you do not smell gas, go to the next step

7. Find pilot. It is adjacent to the burner and may be partially concealed by a decorative cover.

8. Press slightly and turn control knob counterclockwise to “PILOT”. Depress knob and light pilot by repeatedly pressing the igniter. Once flame is established, hold knob depressed for approximately 30 seconds. Release knob. If pilot should go out, repeat steps 3 to 8. • If the knob does not pop up when released, stop and immediately call your service technician or gas supplier. • If the pilot will not stay lit after serveral tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

9. Turn the control knob counterclockwise to the “ON” position.10. Set the wall switch to “ON”. 11. Turn on all electric power to the appliance.12. Close louver or replace trim.

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE

1. Set the wall switch to “OFF”. 2. Turn off all electric power to the appliance if service is to be

performed.3. Open lower louvers or remove trim.4. Press slightly and turn control knob clockwise to “OFF”. Do

not force. Close gas isolation valve.5. Close lower louvers or replace trim.

6 each RED BARS

1. ARRÊTEZ! Lisez les instructions de sécurité sur la portion. supérieure (à gauche) de cette étiquette.

2. Réglez le commutateur à distance sur “OFF”.3. Coupez l’alimentation électrique de l’appareil.4. Ouvrez persiennes inférieurs ou porte d’accès.5. Appuyez légèrement et tournez le bouton de commande dans le

sens horaire à la position “OFF”. vanne d’isolement de gaz ouverte.

6. Attendre cinq (5) minutes pour laisser échapper tout le gaz. Reniflez tout autour de l’appareil, y compris près du plancher, pour déceler un odeur de gaz. Si vous sentez une odeur de gaz, ARRÊTEZ! Passez à l’étape B des instructions de sécurité sur la portion supérieure (à gauche) de cette étiquette. S’il n’y a pas d’odeur de gaz, passez à l’étape suivante.

7. Trouver pilote. Il est adjacent au brûleur et peut être partiellement masqué par un couvercle décoratif.

8. Appuyez légèrement et tournez le bouton de commande vers la gauche pour “PILOT”. Enfoncez le bouton et la veilleuse en appuyant plusieurs fois sur la allumeur. Une fois que la flamme est établie, maintenez le bouton enfoncé pendant environ 30 secondes. bouton de sortie. Si pilote doit sortir, répétez les étapes 3 à 8.• Si la manette ne se soulève pas d’elle-même lorsqu’on la relâche,

arrêter et appeler immédiatement un technicien qualifié ou le fournisseur de gaz.

• Si la veilleuse ne reste pas allumée après plusieurs tentatives, réglez la manette d’admission du gaz à la position OFF et appelez un technicien qualifié ou le fourniesseur de gaz.

9. Tournez le bouton de commande dans le sens antihoraire à la position “ON”.

10. Allumez l’alimentation électrique de l’appareil.11. Réglez le commutateur à distance sur “ON”.12. Persienne fermée ou porte d’accès.

INSTRUCTION D’ALLUMAGE

COMMENT COUPER L’ADMISSION DE GAZ DE L’APPAREIL

303-0001-01 2016/05/02

A. Cet appareil est muni d’une veilleuse qui doit être allumée par allumeur manuel. Respectez les instructions ci-dessous à la lettre.

B. AVANT D’ALLUMER la veilleuse,reniflez tout autour de l’appareil pour déceler une odeur de gaz. Reniflez près du plancher, car certains gaz sont plus lourds que l’air et peuvent s’accumuler au niveau du sol.

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:• Ne pas tenter d’allumer d’appareil• Ne touchez à aucun interrupteur; ne pas vous servir des téléphones

se trouvant dans le bâtiment• Appelez immédiatement votre fournisseur de gaz depuis un voisin.

Suivez les instructions du fournisseur.• Si vous ne pouvez rejoindre le fournisseur, appelez le service des

incendies.C. Ne pousser ou tourner la manette d’admission du gaz qu’à la main. Ne

jamais employer d’outil à cette fin. Si la manette reste coincée, ne tentez pas de la réparer; appelez un technicien qualifié. Quiconque tente de forcer la manette ou de la réparer peut provoquer une explosion ou un incendie.

D. N’utilisez pas cet appareil s’il a été plongé dans l’eau, même partielle-ment. Faites inspecter l’appareil par un technicien qualifié et remplacez toute partie du système de contrôle et toute commande qui ont été longés dans l’eau.

DANGER HOT GLASS WILL CAUSE BURNS.

DO NOT TOUCH GLASS UNTIL COOLED.NEVER ALLOW CHILDREN TO TOUCH GLASS.

A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of

children and other at-risk individuals.

POUR VOTRE SÉCURITÉ VEUILLEZ LIRE AVANT L’ALLUMAGE

CAUTION: Hot while in operation. Do not touch. Severe burns may result. Keep children, clothing,furniture, gasoline, and other liquids having flammable vapors away. Keep burner and control compartment clean. See installation and operating instructions accompanying appliance. Do not operate the appliance with glass removed, cracked, or broken. Replacement of the panel(s) should be done by a licensed or qualified service person.

ATTENTION: L’appareil est chaud lorsqu’il fonctionne. Ne pas toucher l’appareil. Risque de brûlures graves. Surveiller les enfants. Garder les vêtements, les meubles, l’essence ou autres liquides produisant des vapeur inflammables loin de l’appareil. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place, est craqué ou brisé. Confiez le remplacement du panneau à un technicien agréé.

1. Réglez le commutateur à distance sur “OFF”.2. Coupez l’alimentation électrique de l’appareil s’il faut procéder à

l’entretien.3. Ouvrez persiennes inférieurs ou porte d’accès.4. Appuyez légèrement et tournez le bouton de commande dans le

sens horaire à la position “OFF”. vanne d’isolement de gaz à proximité

5. Persienne fermée ou porte d’accès.

DANGER VITRE CHAUDE – RISQUE DE BRÛLURES.

NE TOUCHEZ PAS UNE VITRE NON REFROIDIE.NE LAISSEZ JAMAIS UN ENFANT TOUCHER LA

VITRE.

L’écran pare-étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la

protection on des enfants et des personnes à risques.

SIT Nova 820 RobertShaw 7000MVRB-5-LC

Pilot / Pilote

Gas Control Knob /bouton de commande de gaz

(Shown in “pilot” position / Montré en position “pilote”)

Spark igniter/ spark allumeur

Thermopile

Thermocouple

Flame Adjustment / Réglage de la flamme

Igniter / Allumeur

Figure 19.3.1:

Page 40: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

40

Maintenance20.0 Maintenance

CAUTION:D A

20.1 Cleaning and Routine MaintenanceT

B

Regularly:

• F T DO NOT CLEAN LE OT

• V

• V

Every 2 to 3 months:

• R DO NOT CLEAN LE OT

• C T T D

• A

Once a year, have a qualified service technician:

• P 2 • • • F

Figure 20.5.01• C

• • T

0 • C

WARNING: All parts removed or disturbed, including guards and grills, must be properly replaced after maintenance. Service and repair must be conducted by a qualified service person. If these instructions are not followed, a fire or explosion may result, causing property damage, personal injury or loss of life.

Page 41: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

41

Maintenance20.2 Servicing Under WarrantyB C A

WARNING: S must be conducted by a qualified Archgard service technician A

A A

20.3 Checking Inlet and Outlet Pressure1. F Section 6.42. T T IN OUT". See Figure

18.3.01. 3. L 1 4. C 1 5. V 6. B 7. C

20.4 Checking and Adjusting Pilot

T

S Figure 18.3.01

The pilot flames should have the characteristics shown in the illustration to the right.

Figure 18.3.01

Figure 18.4.01

Figure 18.4.02

INPILOT ADJUSTMENT

OUT

Page 42: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

42

Maintenance

Forward: Open air shutterBackward Close air shutter

20.5 Adjusting the Primary AirT UF0 0

Figure 20.5.01 T Figure 20.5.02 T T

CAUTION: D

Figure 20.5.01:

Figure 20.5.02:

Lazy yellow flames Short blue flames A

Dark orange flames / black tipsA E

Lifting (ghosting) flames V

G

WARNING: S must be conducted by a qualified service technician A

A A

Page 43: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

43

Maintenance

20.6 Wiring Schematic

Figure 20.6.01:

P

P

G V

ON OFF M B Switch

O R S T

R TP T

TP

Page 44: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

44

Maintenance20.7 Removing the Baffle

T U

B :• Ensure the fireplace is off and cool before servicing• Ensure the gas supply is turned OFF and disconnect the power supply• R Section 14.0• R Section 15.0• R Section 18.0• R Section 17.2• R Section 17.1

Step 1: R 1 T S Step 2: D

Figure 20.7.01: Figure 20.7.02:

WARNING: S must be conducted by a qualified service technician A

A A

Page 45: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

45

Maintenance

20.8 Replacing the Burner

Before you begin:• E • D • T • R S Section 16.0• R S Section 14.0

• R S Section 15.0• R S Section 18.0• R S Section 17.0

1 R

2 L L Section 20.4

Section 20.5

Figure 20.8.01:

WARNING: S must be conducted by a qualified service technician A

A A

Page 46: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

46

Maintenance20.9 Replacing the Pilot

Before you begin:• Ensure the fireplace is off and cool before servicing• Ensure the gas supply is turned OFF and disconnect the

power supply• R Section 16.0 • R Section 14.0

• R G D Section 15.0 • R Section 18.0• R Section 17.2• R Section 17.1• R Section 20.8

Step 1: R 1 1 T R 2 1 T S

Step 2: U 1 2 1

Figure 20.9.01: Figure 20.9.02:

Figure 20.9.03:

Step 3: R 1 T

Figure 20.9.04:

Step 4: M

CAUTION: L V T

National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code, CSA C22.1.

Step 5: M R

Figure 20.9.05:

WARNING: S must be conducted by a qualified service technician A

A A

Step 6: M

Figure 20.9.06:

Page 47: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

47

Maintenance

Figure 20.10.01:

Step 1: R 2 1 T

Figure 20.10.02:

Step 2: M

20.10 Replacing the Piezo Igniter

Before you begin:• Ensure the fireplace is off and cool before servicing• Ensure the gas supply is turned OFF and disconnect the power supply• F Section 6.4

Figure 20.10.03:

Step 3: R

WARNING: S must be conducted by a qualified service technician A

A A

Page 48: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

48

Maintenance

20.11 Replacing the Optional Fan Speed Control

Before you begin:• Ensure the fireplace is off and cool before servicing• Ensure the gas supply is turned OFF and disconnect the power supply• F Section 6.4

Figure 20.11.01:

Step 1: G

Figure 20.11.02:

Step 2: R

Figure 20.11.03:

Step 3: U

Note: F

CAUTION: L V T

National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code, CSA C22.1.

WARNING: S must be conducted by a qualified service technician A

A A

Page 49: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

49

Maintenance

20.12 Replacing the Valve

Before you begin:• Ensure the fireplace is off and cool before servicing.• Disconnect power supply to the fireplace and turn off gas

supply.• R S Section 16.0.• R S Section 14.0.

• R S Section 15.0.• R S Section 18.0.• R S Section 17.0.• R See Section 20.8.

Step 1: R 2 1 T U

Figure 20.12.01:

Step 2: D C

Figure 20.12.02:

Step 3: R 2 R V

A S 2

Figure 20.12.03:

Step 4: R O

Section 20.4 Section 20.5

Make sure all lines are tidy and away from the bottom door springs.

Figure 20.12.04:

CAUTION: L V T

National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code, CSA C22.1.

WARNING: S must be conducted by a qualified service technician A

A A

Page 50: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

50

Maintenance

20.13 Replacing the Optional Fan Thermal Sensor

Before you begin:• Ensure the fireplace is off and cool before servicing.• Disconnect power supply to the fireplace and turn off

gas supply.

Figure 20.13.01:

Step 1: T T O

Figure 20.13.02:

Step 2: P M

CAUTION: L V T

National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code, CSA C22.1.

WARNING: S must be conducted by a qualified service technician A

A A

• R Section 16.0

Step 3: L

Page 51: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

51

Maintenance

20.14 Replacing the Optional FanCAUTION: L

V T National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code,

CSA C22.1.

Before you begin:• Ensure the fireplace is off and cool before servicing.• Disconnect power supply to the fireplace and turn off gas

supply.• R S Section 16.0.• R S Section 14.0.

• R S Section 15.0.• R S Section 18.0.• R S Section 17.0.• D

Step 1: R 1 1

Figure 20.14.01:

Step 2: U

Figure 20.14.02:Step 3: R

Figure 20.14.03:

Step 4: S

Figure 20.14.04:Step 6: L

Step 5: R

R

Figure 20.14.05:

Page 52: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

52

Maintenance

20.15 TroubleshootingP

WARNING: T vice technician.

SYMPTOM ACTIONP

1.

R

2. C

3. C :

C C C C

4. P LOT

P lit.

1. P 2. 3.

0 4. C 5. C T 20

V 6. C

T

1. C ON 2. A

activate the valve.3. C

4. C 5. C

6. C 7. C 00 00 V 18 2 0 V

8. C

T

1. T 2. C 3. C 4.

practices.5. C E

Page 53: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

53

Maintenance

SYMPTOM ACTIONS 1.

2. C E

S 3. C 4. C

S

1. T R D

F 1. T T 1

2. C 120 VAC 3. OFF 4. C 5. C 6. C 7. C 8. C

All service and repairs should be performed by a qualified and licensed service technician.

Page 54: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

54

Maintenance

21.0 Frequently Asked QuestionsL A G F

A A D

M A C T CP

A F

D

A DO NOT NOTE: A

M A Y A

N :

A T

Y T

ON OFFA Y G C V T

C A N B

O

C A Y R R

C A N Y

C

Page 55: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

55

Maintenance

22.0 Replacement Parts ListItem # Item Description Unit

200 0 0 02 O M E EA200 0 0 F 02 O M F EA

URP 890 0200 B S EA08 0 0 S T 820 G V EA0 001 F S C EA08 000 P EAUA9004 O F EA

RF 0 0 2 R F EA

01 00 8 O DMS N G EA01 00 8 1 O 1 DMS P EA

08 0120 P A EA1 01 9 P G EA01 2 2 P G L EA

URP 89 00 0 B A L B EA

UA9006 C LP NG EAUA9005 C NG LP EA

10 U 00 01 C L S SETURP 890 0000 C R D EA

Page 56: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

NOTES

Page 57: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

57

WarrantyWarranty Information10 Year Limited WarrantyT L 10 Y R F A 11 B D M BC C V2V B T 0 F

A A F

S A A

YEAR 1: S A A

YEAR 2-10: S A

A

LIMITATION OF LIABILITY

T

T U

T

N A the unit.

A A T

A T

S T

A

A

WARRANTY CONDITIONS & REQUIREMENTS1. Y T 2. 3. 4. P 0 5. R 1 6. T L B B T

7. C

8. T 9. A 10. A C

11. A C

Page 58: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

58

WarrantyLifetime Warranty

THIS LIFETIME WARRANTY COVERAGE WILL BE EXTENDED AS DESCRIBED BELOW PROVIDED ALL WARRANTY CONDITIONS AND REQUIREMENTS ARE MET AS OUTLINED IN THE 10 YEAR LIMITED WARRANTY POLICY.

LIFETIME WARRANTY COVERAGE

L FET ME ARRANTY S E TENDED AS FOLLO S: A A F

A T L FET ME ARRANTY

LIMITATION OF LIABILITY

T L U T L

T

N L A

A L

L A A

A T A

T

A

A

To activate this LIFETIME WARRANTY coverage, the registration card must be completed and mailed to the following address within 30 days of installation:

Archgard Industries7116 Beatty Drive

Mission, BC, CANADAV2V 6B4

Page 59: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English

WARRANTY REGISTRATION

ARCHGARD INDUSTRIES LTD.7116 BEATTY DRIVE

MISSION, B.C. CANADAV2V 6B4

POSTAGE

CU

T AL

ON

G L

INE

CU

T AL

ON

G L

INE

CU

T AL

ON

G L

INE

FOLD DOWN AT LINE

FOLD DOWN AT LINE & TAPE CLOSED

Model # : Serial #: Date Installed: / /

Name: Address: City: State/Prov: ZIP: Phone: ( _____ )

Dealer’s Name & Address:

City: State/Prov: ZIP: Phone: ( _____ )

Installer’s Name & Address:

City: State/Prov: ZIP: Phone: ( _____ )

Why did you choose this product?

Thank you for purchasing our product and filling out this warranty card. Save time by completing this form at

www.archgard.com/warranty-registration

Page 60: Inspiration 29MV · G AS FIRE IREC E T FIREPLACE I SERT S N 650000 A D UP ARCHGARD FIREPLACE PRODUCTS 7116 eatt D rive M issi n C 2 6 4 Cana a 200 U505 02 Fe ruar 12 2019 English