inspection reportaprecisioninspection.com/wp-content/uploads/2013/06/sample-report… · any...
TRANSCRIPT
Inspection Report
Property Address: 12345 Sample Street
Baton Rouge La.
A+ Precision Inspection, LLC
Gordon Atwell LSBHI# 10617 10617 35635 Woodland Ridge Dr. Denham Springs, LA 70706
225-333-1020
Page 1 of 2612345 Sample Street
Table of Contents
Cover Page
Table of Contents
Intro Page
1 Roofing
2 Exterior
3 Garage
4 Interiors
5 Structural Components
6 Plumbing System
7 Electrical System
8 Heating / Central Air Conditioning
9 Insulation and Ventilation
10 Built-In Kitchen Appliances
General Summary
Invoice
Page 2 of 2612345 Sample Street
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
Date: 10/21/2009 Time: 12:00 PM Report ID: 123 Sample
Property: 12345 Sample Street Baton Rouge La.
Customer: Real Estate Professional:
In Attendance: Customer and their agent
Type of building: Single Family (1 story)
Approximate age of building: Under 10 Years
Temperature: Over 65
Weather: Clear
Ground/Soil surface condition: Dry
Rain in last 3 days: No
Page 3 of 2612345 Sample Street
1. Roofing
Styles & Materials
Roof Covering: Architectural
Viewed roof covering from: Walked roof
Chimney (exterior): EIFS/Stucco
Inspection Items
1.0 ROOF COVERINGS Comments: Inspected
1.1 FLASHINGS Comments: Inspected
1.2 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS Comments: Repair or Replace
The tacks in on the two metal flashing positioned on the back roof should be caulked to prevent leaking in the future. There is no evidence that there is a present leak.
1.2 Picture 1
1.2 Picture 2
1.3 ROOF DRAINAGE SYSTEMS Comments: Repair or Replace
It is recommended all gutters discharge at least 4 feet from the house.
Several of the downspouts are bent possibly restricting water flow.
Recommend all gutters and downspouts be cleaned of debris.
1.3 Picture 1
1.3 Picture 2
Page 4 of 2612345 Sample Street
The roof of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Roof coverings and skylights can appear to be leak proof during inspection and weather conditions. Our inspection makes an attempt to find a leak but sometimes cannot. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
1.3 Picture 3
Page 5 of 2612345 Sample Street
2. Exterior
Styles & Materials
Siding Style: Brick
Siding Material: Brick veneer EIFS
Exterior Entry Doors: Wood
Appurtenance: Covered porch Patio
Driveway: Concrete
Inspection Items
2.0 WALL CLADDING FLASHING AND TRIM Comments: Repair or Replace
Recommend caulking all corners where stucco and brick meet. (PIcture 1)
Recommend painting EIFS/stucco as a matter of preventative maintenance.
Recommend sealing crack on the siding by hot water heater vent lines.(Picture 2)
2.0 Picture 1
2.0 Picture 2
2.1 DOORS (Exterior) Comments: Inspected
2.2 WINDOWS Comments: Repair or Replace
Recommend caulking and sealing around all windows, specifically the window for the bathroom (Picture 1), and the bedroom window on the back corner close to the patio (picture 2).
Mortar should be sealed on window ledge by driveway window on the corner of the house.
Page 6 of 2612345 Sample Street
2.2 Picture 1
2.2 Picture 2
2.2 Picture 3
2.3 DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES, PATIO/ COVER AND APPLICABLE RAILINGS Comments: Repair or Replace
The speaker in the corner of the patio is hanging by the wires. This is minor maintenance.
2.3 Picture 1
2.4 VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIO FLOOR, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) Comments: Repair or Replace
Recommend trimming all vegetation from the house by at least four feet.
Page 7 of 2612345 Sample Street
The exterior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
2.4 Picture 1
2.5 EAVES, SOFFITS AND FASCIAS Comments: Repair or Replace
There is some soft wood decay on the back corner fascia and soffit by the patio.
2.5 Picture 1
Page 8 of 2612345 Sample Street
3. Garage
Styles & Materials
Garage Door Type: One manual One automatic
Garage Door Material: Metal
Auto-opener Manufacturer: LIFT-MASTER 1/2 HORSEPOWER
Inspection Items
3.0 GARAGE CEILINGS Comments: Repair or Replace
The ceiling has a gap by the pull down door in the storage room.
3.0 Picture 1
3.1 GARAGE WALLS Comments: Inspected
3.2 GARAGE FLOOR Comments: Inspected
3.3 GARAGE DOOR (S) Comments: Repair or Replace
The trim around the metal door for the small storage room should be sealed.
3.3 Picture 1
3.4 GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance) Comments: Repair or Replace
The garage door will not reverse when met with resistance it does reverse when the beam is interrupted.
Page 9 of 2612345 Sample Street
4. Interiors
Styles & Materials
Ceiling Materials: Sheetrock
Wall Material: Sheetrock
Floor Covering(s): Carpet Hardwood T&G Tile
Interior Doors: Hollow core
Window Types: Thermal/Insulated
Cabinetry: Wood
Countertop: Tile Cultured marble
Inspection Items
4.0 CEILINGS Comments: Inspected
4.1 WALLS Comments: Inspected
4.2 FLOORS Comments: Repair or Replace
Wood floor has a gap by the door to the hallway and in the hallway.
4.2 Picture 1
4.2 Picture 2
4.3 STEPS, STAIRWAYS, BALCONIES AND RAILINGS Comments: Inspected
4.4 COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS Comments: Repair or Replace
A couple of cabinet doors in the washer/dryer room do not close flush against the stop.
Page 10 of 2612345 Sample Street
The interior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
4.4 Picture 1
4.5 DOORS (REPRESENTATIVE NUMBER) Comments: Inspected
4.6 WINDOWS (REPRESENTATIVE NUMBER) Comments: Inspected
Page 11 of 2612345 Sample Street
5. Structural Components
Styles & Materials
Foundation: Poured concrete
Floor Structure: Slab
Wall Structure: Wood
Ceiling Structure: Not visible
Roof Structure: Stick-built
Roof-Type: Hip
Method used to observe attic: Walked
Attic info: Pull Down stairs Storage Light in attic
Inspection Items
5.0 FOUNDATIONS, BASEMENTS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) Comments: Repair or Replace
There is evidence of potential wood destroying insects. Recommend qualified pest control technician evaluate and address.
There is some minor corner cracking on slab. Recommend cracks be sealed with mortar or caulk.
5.0 Picture 1
5.0 Picture 2
5.1 WALLS (Structural) Comments: Inspected
5.2 FLOORS (Structural) Comments: Inspected
5.3 CEILINGS (structural) Comments: Inspected
5.4 ROOF STRUCTURE AND ATTIC Comments: Inspected
Roof structure is sound.
Page 12 of 2612345 Sample Street
The structure of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
5.4 Picture 1
5.4 Picture 2
Page 13 of 2612345 Sample Street
6. Plumbing System
Styles & Materials
Water Source: Public
Plumbing Water Supply (into home): Not visible
Plumbing Water Distribution (inside home): Copper
Washer Drain Size: 2" Diameter
Plumbing Waste: PVC
Water Heater Power Source: Gas (quick recovery)
Water Heater Capacity: 50 Gallon
Manufacturer: RHEEM
Water Heater Location: Attic
Inspection Items
6.0 PLUMBING DRAIN, WASTE AND VENT SYSTEMS Comments: Inspected
6.1 PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES Comments: Repair or Replace
The shower head on in the master bathroom sprays water up the wall. (Picture 1)
The trim ring for the hot water valve has a gap in it. (Picture 2)
The kitchen sink spigot does not swivel properly. (Picture 3)
There is a cracked trim ring on the spray nozzle for the kitchen sink. (Picture 4)
The wall paper is peeling in the shower for the hall bathroom. (Picture 5)
6.1 Picture 1
6.1 Picture 2
Page 14 of 2612345 Sample Street
6.1 Picture 3 6.1 Picture 4
6.2 HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS Comments: Inspected
The hot water heater is leaking from the top of the unit. It is running down into the pan and out the drain to the outside. Recommend a qualified technician evaluate and repair or replace.
6.2 Picture 1
6.2 Picture 2
6.3 MAIN WATER SHUT-OFF DEVICE (Describe location) Comments: Inspected
Water cut off is located by the Air Conditioning unit.
6.3 Picture 1
6.4 FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) Comments: Inspected
Page 15 of 2612345 Sample Street
The plumbing in the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Washing machine drain line for example cannot be checked for leaks or the ability to handle the volume during drain cycle. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
6.5 MAIN FUEL SHUT OFF (Describe Location) Comments: Inspected
The gas meter and cut off is located on the front corner of the house.
6.5 Picture 1
Page 16 of 2612345 Sample Street
7. Electrical System
Styles & Materials
Electrical Service Conductors: Below ground
Panel capacity: 200 AMP
Panel Type: Circuit breakers
Electric Panel Manufacturer: CUTLER HAMMER
Branch wire 15 and 20 AMP: Copper
Wiring Methods: Romex
Inspection Items
7.0 SERVICE ENTRANCE CONDUCTORS Comments: Inspected
7.1 SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS Comments: Inspected
7.2 BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE Comments: Inspected
7.3 CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) Comments: Repair or Replace
There are two junction boxes in the attic that do not have covers on them. Recommend installation of proper cover . This is minor maintenance.
7.3 Picture 1
7.3 Picture 2
7.4 POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE Comments: Inspected
7.5 OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) Comments: Inspected
7.6 LOCATION OF MAIN AND DISTRIBUTION PANELS Comments: Inspected
Panel is located on the side of the house by the driveway.
Page 17 of 2612345 Sample Street
The electrical system of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Outlets were not removed and the inspection was only visual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
7.6 Picture 1
7.7 SMOKE DETECTORS Comments: Inspected
Page 18 of 2612345 Sample Street
8. Heating / Central Air Conditioning
Styles & Materials
The heating and cooling system of this home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection is not meant to be technically exhaustive. The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensed heat contractor would discover. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Heat Type: Forced Air
Energy Source: Gas
Number of Heat Systems (excluding wood): One
Heat System Brand: TRANE
Ductwork: Insulated
Filter Type: Disposable
Types of Fireplaces: Vented gas logs Gas/LP Log starter Insert
Operable Fireplaces: One
Cooling Equipment Type: Air conditioner unit
Cooling Equipment Energy Source: Electricity
Central Air Manufacturer: TRANE
Number of AC Only Units: One
Inspection Items
8.0 HEATING EQUIPMENT Comments: Inspected
8.1 NORMAL OPERATING CONTROLS Comments: Inspected
8.2 AUTOMATIC SAFETY CONTROLS Comments: Inspected
8.3 DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) Comments: Inspected
8.4 PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM Comments: Inspected
8.5 CHIMNEYS, FLUES AND VENTS (for fireplaces, gas water heaters or heat systems) Comments: Inspected
8.6 SOLID FUEL HEATING DEVICES (Fireplaces, Woodstove) Comments: Inspected
8.7 GAS/LP FIRELOGS AND FIREPLACES Comments: Inspected
8.8 COOLING AND AIR HANDLER EQUIPMENT Comments: Inspected
The ambient air test was performed by using thermometers on the air handler of Air conditioner to determine if the difference in temperatures of the supply and return air are between 14 degrees and 22 degrees which indicates that the unit is cooling as intended. The supply air temperature on your system read 58 degrees, and the return air temperature was 73 degrees. This indicates the range in temperature drop is normal. The unit is cooling properly.
8.9 NORMAL OPERATING CONTROLS Comments: Inspected
8.10 PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOM Comments: Inspected
Page 19 of 2612345 Sample Street
9. Insulation and Ventilation
Styles & Materials
The insulation and ventilation of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Venting of exhaust fans or clothes dryer cannot be fully inspected and bends or obstructions can occur without being accessible or visible (behind wall and ceiling coverings). Only insulation that is visible was inspected. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Attic Insulation: Blown
Ventilation: Ridge vents Soffit Vents
Exhaust Fans: Fan with light Fan/Heat/Light
Dryer Power Source: 220 Electric
Dryer Vent: Metal
Inspection Items
9.0 INSULATION IN ATTIC Comments: Inspected
9.1 VENTILATION OF ATTIC AND FOUNDATION AREAS Comments: Inspected
9.2 VENTING SYSTEMS (Kitchens, baths and laundry) Comments: Repair or Replace
There is a crushed vent line at the top of the pull down stairs. Recommend repair.
9.2 Picture 1
Page 20 of 2612345 Sample Street
10. Built-In Kitchen Appliances
Styles & Materials
The built-in appliances of the home were inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2008 : Licensed To A Precision Inspection, LLC
Dishwasher Brand: FRIGIDAIRE
Disposer Brand: IN SINK ERATOR
Exhaust/Range hood: FRIGIDAIRE
Range/Oven: FRIGIDAIRE
Built in Microwave: FRIGIDAIRE
Inspection Items
10.0 DISHWASHER Comments: Inspected
10.1 RANGES/OVENS/COOKTOPS Comments: Inspected
10.2 RANGE HOOD Comments: Inspected
10.3 FOOD WASTE DISPOSER Comments: Inspected
10.4 MICROWAVE COOKING EQUIPMENT Comments: Inspected
Page 21 of 2612345 Sample Street
The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the home. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.
General Summary
A+ Precision Inspection, LLC
35635 Woodland Ridge Dr. Denham Springs, LA 70706
225-333-1020
Customer
Address 12345 Sample Street
Baton Rouge La.
1.2 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS
Repair or Replace
The tacks in on the two metal flashing positioned on the back roof should be caulked to prevent leaking in the future. There is no evidence that there is a present leak.
1.3 ROOF DRAINAGE SYSTEMS
Repair or Replace
It is recommended all gutters discharge at least 4 feet from the house.
Several of the downspouts are bent possibly restricting water flow.
Recommend all gutters and downspouts be cleaned of debris.
1. Roofing
2.0 WALL CLADDING FLASHING AND TRIM
Repair or Replace
Recommend caulking all corners where stucco and brick meet. (PIcture 1)
Recommend painting EIFS/stucco as a matter of preventative maintenance.
2. Exterior
Page 22 of 2612345 Sample Street
Recommend sealing crack on the siding by hot water heater vent lines.(Picture 2)
2.2 WINDOWS
Repair or Replace
Recommend caulking and sealing around all windows, specifically the window for the bathroom (Picture 1), and the bedroom window on the back corner close to the patio (picture 2).
Mortar should be sealed on window ledge by driveway window on the corner of the house.
2.3 DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES, PATIO/ COVER AND APPLICABLE RAILINGS
Repair or Replace
The speaker in the corner of the patio is hanging by the wires. This is minor maintenance.
2.4 VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIO FLOOR, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building)
Repair or Replace
Recommend trimming all vegetation from the house by at least four feet.
2.5 EAVES, SOFFITS AND FASCIAS
Repair or Replace
There is some soft wood decay on the back corner fascia and soffit by the patio.
2. Exterior
3.0 GARAGE CEILINGS
Repair or Replace
The ceiling has a gap by the pull down door in the storage room.
3.3 GARAGE DOOR (S)
Repair or Replace
The trim around the metal door for the small storage room should be sealed.
3.4 GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance)
Repair or Replace
The garage door will not reverse when met with resistance it does reverse when the beam is interrupted.
3. Garage
4.2 FLOORS
Repair or Replace
Wood floor has a gap by the door to the hallway and in the hallway.
4.4 COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS
Repair or Replace
A couple of cabinet doors in the washer/dryer room do not close flush against the stop.
4. Interiors
5.0 FOUNDATIONS, BASEMENTS AND CRAWLSPACES (Report signs of abnormal or harmful water
5. Structural Components
Page 23 of 2612345 Sample Street
Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes of the need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Home inspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspector or other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardous substance, including but not limited to mold, toxins, carcinogens,
penetration into the building or signs of abnormal or harmful condensation on building components.)
Repair or Replace
There is evidence of potential wood destroying insects. Recommend qualified pest control technician evaluate and address.
There is some minor corner cracking on slab. Recommend cracks be sealed with mortar or caulk.
5. Structural Components
6.1 PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Repair or Replace
The shower head on in the master bathroom sprays water up the wall. (Picture 1)
The trim ring for the hot water valve has a gap in it. (Picture 2)
The kitchen sink spigot does not swivel properly. (Picture 3)
There is a cracked trim ring on the spray nozzle for the kitchen sink. (Picture 4)
The wall paper is peeling in the shower for the hall bathroom. (Picture 5)
6. Plumbing System
7.3 CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Repair or Replace
There are two junction boxes in the attic that do not have covers on them. Recommend installation of proper cover . This is minor maintenance.
7. Electrical System
9.2 VENTING SYSTEMS (Kitchens, baths and laundry)
Repair or Replace
There is a crushed vent line at the top of the pull down stairs. Recommend repair.
9. Insulation and Ventilation
Page 24 of 2612345 Sample Street
noise, contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limited to failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information should hire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.
Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2008 : Licensed To A Precision Inspection, LLC
Page 25 of 2612345 Sample Street
Inspection Fee:
Payment Method: Payment Status: Note:
INVOICE
A+ Precision Inspection, LLC 35635 Woodland Ridge Dr. Denham Springs, LA 70706 225-333-1020 Inspected By: Gordon Atwell LSBHI# 10617
Inspection Date: 10/21/2009 Report ID: 123 Sample
Customer Info: Inspection Property:
12345 Sample Street Baton Rouge La. 70817
Customer's Real Estate Professional:
12345 Sample Street Baton Rouge La.
Service Price Amount Sub-Total
Tax $0.00
Total Price $0.00
Page 26 of 2612345 Sample Street