important information - docs-emea.rs … fused spur is a double pole residual current device (rcd)...
TRANSCRIPT
60.3 REF
86.0
86.0
TOP TERMINALS = SUPPLY
BOTTOM TERMINALS = LOAD
IMPORTANT INFORMATION
13.5 REF
27.2
D
E
C
B
A
321 54 6 8
H92WPA Product Specification GB400343SHEET 1 OF 3
SCALE: 1:1
DWG NO.TITLE:
AN
D D
ESIG
N G
REEN
BRO
OK
ELEC
TRIC
AL
PLC
. CO
NTE
NTS
STR
ICTL
Y PR
IVA
TE A
ND
CO
NFI
DEN
TIAL.
TO
BE
USED
ON
LY F
OR
THE
PURP
OSE
S N
OTIF
IED
BY
GRE
ENBR
OO
K EL
ECTR
ICA
L PL
C. O
R ITS
LIC
ENC
EE.
ALL
INTE
LLEC
TUA
L PR
OPE
RTY
IN A
ND
IN R
ELA
TION
TO
THI
S D
RAW
ING
AN
D IT
S SU
BJEC
T M
ATT
ER A
RE R
ESER
VED
, AN
D H
EREB
Y LI
CEN
CED
TO
GRE
ENBR
OO
K EL
ECTR
ICA
L PL
C.
ISS CCD DATE
DO NOT SCALE THIS DRAWINGDRAWN BY C.EGREENBROOK
WEST ROAD, HARLOWESSEX CM20 2BG UK
A 102 22/12/10
MATERIAL:FINISH:
PROJECTION THIRD ANGLE. IF IN DOUBT ASK
TOLERANCES(UNLESS STATED OTHERWISE)
- 1 DEC PLACE 0.4- 2 DEC PLACE 0.1- ANGULAR 1.0
DRAFT CONSIDERATIONS(S) - SMALLEST DIMENSION(L) - LARGEST DIMENSIONGENERAL - 1 PER SIDE 0.5
ALL DIMENSIONS IN MILLIMETERS
7
A3G
B
DESC
RIPTIO
N - H
92WPA
- RC
D Fused Spur - W
hite
The Fused Spur is a double pole R
esidual Current D
evice (RC
D) in the form
of a 13 amp
device. It is designed and manufactured to the requirem
ents of BS
1363-4 & B
S7288.
The product is based upon a generic design and construction with variations to include:
White P
lastic face plate version for domestic m
achines in the home.
Metal clad enclosure variant for the m
ore robust applications.
CLA
SSIFICA
TION
RC
D Fused S
purD
ouble Pole break
Mechanically latched ( contacts rem
ain closed when m
ains power is rem
oved and re-applied) - generally defined as “Passive”C
LAS
S 2 device.
BR
ITISH A
ND
EUR
OPEO
N STA
ND
AR
DS
Current S
tandardsB
S7288 :1990 A
md 1( socket out-lets incorporating S
RC
D`s )
BS
1363-4:1995 Am
d 1, 2, 3 (Specification for 13A
Fused connection units switched and unsw
itched) E
MC
:E
missions: E
N 55014-1:2006 &
EN
55014-1:2000 inc A1:2001 &
A2:2002
Imm
unity: EN
61543:1995 inc A11:2003, A
12:2005 & A
2:2006
RA
TING
Voltage 230 V
olts AC
Current (m
ax) 13 Am
p Resistive &
InductiveFrequency 50 H
ertzE
nvironmental IP
40 (Ingress Protection R
ating)Trip C
urrent 30 mA
maxim
um 22 m
A typical
Non Trip C
urrent 15 mA
max
Trip Speed 20 m
Seconds
Circuit fault break current 1500A
mps
Earth fault break current 250 A
mps
DESIG
N FEA
TUR
ES
Fuse Holder can be locked out for safety.
Twin earth term
inals.Integral cord outlet and cable clam
p.(4.6 to 10.4mm
max D
ia cable)W
hite Button: S
witches m
echanism “O
N”
Trip indication: Red flag and light - visible only w
hen mechanism
ON
(closed contacts)G
rey Test Button: A
ctivates mechanism
to “OFF”
Enclosure: Front plate - R
obust hard to scratch material - com
pression thermoset plastic. C
olour - 'White'.
Rear m
olding: Nylon 7, C
olour “Black”
INSTA
LLATIO
N &
TESTING
System
Install in-line with the 17th E
dition Wiring R
egulations.R
outine Testing Assum
ing the device has been installed correctly the RC
D should be tested regularly, each tim
e before use, as follows:-
Press W
hite button fully in and releaseW
indow indicator show
s “RE
D” and illum
inates.P
ress Grey Test button fully in and release.
Window
indicator has turned WH
ITE (no illum
ination )
In this test the device has latched ready for use and then has been tested using the in built test function. Device is now
ready for normal use.
To Use - P
ress and release White button. R
ed flag and illumination w
ill be displayed in the respective window
..R
CD
Perform
ance Testing. RC
D testers (R
OB
IN K
MP
5406) are available for this purpose.C
ircuit Insulation, Resistance and E
arth Fault loop impedance Testing:
It is important that the device is disconnected during these tests
otherwise the internal electronics m
aybe damaged.
SERVIC
E CO
ND
ITION
S
Temperature -5 to +40 degrees C
Altitude 2000m
max (above sea level)
Abnorm
al conditions Avoid pollution by sm
oke, chemical and flam
mable fum
es,S
alt laden spray, periods of high humidity, greater 95%
Relative H
umidity (R
.H.)
D
E
C
B
A
321 54 6 8
H92WPA Product Specification GB400343SHEET 2 OF 3
SCALE: 1:1
DWG NO.TITLE:
AN
D D
ESIG
N G
REEN
BRO
OK
ELEC
TRIC
AL
PLC
. CO
NTE
NTS
STR
ICTL
Y PR
IVA
TE A
ND
CO
NFI
DEN
TIAL.
TO
BE
USED
ON
LY F
OR
THE
PURP
OSE
S N
OTIF
IED
BY
GRE
ENBR
OO
K EL
ECTR
ICA
L PL
C. O
R ITS
LIC
ENC
EE.
ALL
INTE
LLEC
TUA
L PR
OPE
RTY
IN A
ND
IN R
ELA
TION
TO
THI
S D
RAW
ING
AN
D IT
S SU
BJEC
T M
ATT
ER A
RE R
ESER
VED
, AN
D H
EREB
Y LI
CEN
CED
TO
GRE
ENBR
OO
K EL
ECTR
ICA
L PL
C.
ISS CCD DATE
DO NOT SCALE THIS DRAWINGDRAWN BY C.EGREENBROOK
WEST ROAD, HARLOWESSEX CM20 2BG UK
A 102 22/12/10
MATERIAL:FINISH:
PROJECTION THIRD ANGLE. IF IN DOUBT ASK
TOLERANCES(UNLESS STATED OTHERWISE)
- 1 DEC PLACE 0.4- 2 DEC PLACE 0.1- ANGULAR 1.0
DRAFT CONSIDERATIONS(S) - SMALLEST DIMENSION(L) - LARGEST DIMENSIONGENERAL - 1 PER SIDE 0.5
ALL DIMENSIONS IN MILLIMETERS
7
A3G
B
CONNECTIONS
L N E Notes Trip Damaged after connected Test Button Protection Output LED
L N E Correctly connected No No Functional OK ON
L E N Earth and Neutral reversed No No Functional OK ON
N L E Line and Neutral reversed No No Functional OK ON
N E L Line to Earth, always dangerous No No Not Functional OK ON (weak brightness)
E N L Line to Earth, always dangerous No No Not Functional OK ON (weak brightness)
E L N No No Functional OK ON
L N - Earth not connected No No Functional OK ON
N L - Earth not connected No No Functional OK ON
L - E Neutral not connected No No Not Functional OK ON (weak brightness)
E - L Neutral not connected No No Not Functional OK ON (weak brightness)
- N E Line not connected No No Not Functional no leakage current occur OFF
- E N Line not connected No No Not Functional no leakage current occur OFF
L E Dangerous No No Not Functional OK ON (weak brightness)
D
E
C
B
A
321 54 6 8
H92WPA Product Specification GB400343SHEET 3 OF 3
SCALE: 1:1
DWG NO.TITLE:
AN
D D
ESIG
N G
REEN
BRO
OK
ELEC
TRIC
AL
PLC
. CO
NTE
NTS
STR
ICTL
Y PR
IVA
TE A
ND
CO
NFI
DEN
TIAL.
TO
BE
USED
ON
LY F
OR
THE
PURP
OSE
S N
OTIF
IED
BY
GRE
ENBR
OO
K EL
ECTR
ICA
L PL
C. O
R ITS
LIC
ENC
EE.
ALL
INTE
LLEC
TUA
L PR
OPE
RTY
IN A
ND
IN R
ELA
TION
TO
THI
S D
RAW
ING
AN
D IT
S SU
BJEC
T M
ATT
ER A
RE R
ESER
VED
, AN
D H
EREB
Y LI
CEN
CED
TO
GRE
ENBR
OO
K EL
ECTR
ICA
L PL
C.
ISS CCD DATE
DO NOT SCALE THIS DRAWINGDRAWN BYGREENBROOK
WEST ROAD, HARLOWESSEX CM20 2BG UK
A 102 22/12/10
MATERIAL:FINISH:
PROJECTION THIRD ANGLE. IF IN DOUBT ASK
TOLERANCES(UNLESS STATED OTHERWISE)
- 1 DEC PLACE 0.4- 2 DEC PLACE 0.1- ANGULAR 1.0
DRAFT CONSIDERATIONS(S) - SMALLEST DIMENSION(L) - LARGEST DIMENSIONGENERAL - 1 PER SIDE 0.5
ALL DIMENSIONS IN MILLIMETERS
7
A3G
B