Micro-Technologies for Implantable Strain Gauge Arrays
Anais Sahabian William C. Tang
Gloria Yang
![Page 2: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/2.jpg)
Implantable Bone Strain Gauges
Advantages: Better understanding of types
of strain bones undergo when affected by conditions such as osteoporosis or a tumor
Better understanding of the musculoskeletal system
Help create better orthopedic implants
![Page 3: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/3.jpg)
Fabrication of Parylene-Based Strain Gauge
Taken from “Parylene-Based Strain Sensors for Bone”
Taken from “Parylene-Based Strain Sensors for Bone”
![Page 4: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/4.jpg)
Thermal Distribution Simulation
![Page 5: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/5.jpg)
Thermal Distribution: Cross-Sectional View
![Page 6: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/6.jpg)
Results
The results were used as a qualitative analysis as opposed to a quantitative one. The simulation could not be done using the actual size of the device because of the lack of memory needed to compute the solutions.
In the real strain gauge, the gold is actually 9 times thinner and the current applied is magnitudes smaller. This means that the strain gauge will only slightly increase in temperature and the tissue and bone surrounding the parylene C will not feel the heat from the gold strain gauge.
![Page 7: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/7.jpg)
Polypyrrole Deposition
Polypyrrole (PPy) is a naturally conductive polymer
Its conductivity changes with strain
Goal: To understand PPy properties so we can make a strain gauge using polypyrrole as the sensing mechanism
![Page 8: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/8.jpg)
PPy Deposition Setup
Silicon Wafer
Counter Electrode
Reference Electrode
![Page 9: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/9.jpg)
After the Deposition
![Page 10: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/10.jpg)
Preliminary Results
After measuring the thicknesses of the PPy-coated wafers a correlation can be seen between amount of current applied and the thickness of the wafer.
Specifically, as the current increases the thickness of PPy deposited onto the wafer increases.
This correlation must be tested further to better understand exactly what currents give rise to certain thickness.
![Page 11: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/11.jpg)
Carbon Black Doped PDMS
PDMS is not naturally conductive, while carbon black is.
When the two are mixed together the PDMS becomes conductive.
This is useful because it can be used as the sensing mechanism in strain gauges.
![Page 12: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/12.jpg)
Compression Tests
A compression device was created to test the conductive properties of carbon black doped PDMS
![Page 13: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/13.jpg)
Components of Setup
![Page 14: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/14.jpg)
Stress vs. Strain Curve
![Page 15: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/15.jpg)
Resistance vs. Strain Curve
![Page 16: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/16.jpg)
Preliminary Results
As expected, when strain increases, the resistance of the PDMS decreases.
This shows that carbon black doped PDMS is sensitive enough to be used in a strain gauge.
The PDMS piece might become deformed after the first cycle, which would explain the decrease in resistance after each cycle.
![Page 17: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/17.jpg)
Future Work
Characterize PPy deposition parameters and resistivity change with strain.
Conduct compression tests to characterize carbon black doped PDMS.
![Page 18: Implantable Strain Gauge Arrays and Cochlear Implants](https://reader033.vdocuments.us/reader033/viewer/2022051201/58a027c11a28ab174a8c4f5b/html5/thumbnails/18.jpg)
Acknowledgements
National Science Foundation and UROP Prof. William C. Tang Gloria Yang IM-SURE Fellows Said Shokair