Product Data SheetEdition 18/01/2010Identification no: 2.06.010Igol A
1 1/3Igol A
IgolA
Bituminous anionic emulsion
ProductDescription
IgolA is a bituminous anionic emulsions, in fluid form, solvent and phenol -free.
Uses n Suitable for use in many different applications and especially waterproofing ofconcrete structures that are going to be backfilled such as foundations,retaining walls, floors etc.
n Waterproofing and protection of building constructions made of concrete,mortars, bricks.
Characteristics /Advantages
n Easy application
n Supplied ready to use
n Economic product
n Excellent adhesion over different substrates
n Very low content of aggregates and as a result does not absorbs water
n Resistant to ground-root acids
n Solvent free, non-flammable and odourless product
n Can be applied on dry or slightly damp surfaces
Product Data
Form
Appearance / Colours Liquid emulsion, black
Packaging 5 kg pail
25 kg pail
200kg drum
Storage
Storage Conditions/Shelf-Life
24 months from date of production, if stored properly in unopened and undamagedoriginal sealed packaging. Store in dry conditions between +5C to +35C. Protectfrom frost.
Technical Data
Chemical Base Bituminous anionic emulsion
Density 0.960 1.020 kg/l
Curing Speed / Rate Surface - dry after 24 hour
Dependent on the ambient temperature, substrate temperature, relative humidityand the thickness of the coating.
-
8/9/2019 Igol A
2/3
2 2/3Igol A
Dry solid distillationremaining
Min. 56% by weight.
Water content ~ 35 45 %
Viscosity 150 170 (100 RPM spindle 562)
The fluidity can be adjusted with the max. addition of water up to 20%. Mix wellbefore use.
pH rate 7-14
Penetration Tests over remaining: 100 200 (ASTM D5)
Cinder Tests over remaining: 2% max
SystemInformation
Application Details
Consumption / Dosage 0.3 0.5 kg/m2per coat.
The consumption depends on the absorption, the type, the structure of the surfaceand the required protection grade. Generally over porous surfaces at least twocoats are required.
Substrate Quality Substrate must be clean, smooth dry, free of dust, oil or grease and loose or friable
particles. Surface defects such as blowholes, voids, honeycombing, etc. in theconcrete must be repaired with suitable Sika mortars before coating.
Substrate Preparation Repair damaged substrates with SikaMonoTop
or SikaTop
repair mortars.
Rinsing concrete surfaces with clean water.
Clean contaminated substrates by suitable means including steam cleaning or highpressure water jetting or with the use of mechanical means etc.
ApplicationConditions /Limitations
Substrate Temperature +5C min. / +35C max.
Ambient Temperature +5C min. / +40C max.
ApplicationInstructions
Application Method /Tools
The product can be applied by brush, roller or spray.
Apply the product in crossway coats. The waterproofing ability of the product startswhen it is fully cured.
If the product is been used as a primer dilute the first coat with 20% of clear water.Any next coat or coats must be applied without diluting them.
Cleaning of Tools Clean all tools and application equipment with water immediately after use. CuredIgol
A can be removed with Sika
Colma - Cleaner. Any hardened material can
only be removed mechanically.
Waiting Time /Overcoating
Overcoating (time that it takes to dry out): 24 hours (at +20
C)
Dependent on the ambient temperature, substrate temperature, relative humidityand the thickness of coating applied.
Notes on Application /Limitations
Do not apply the product in direct sunlight. If it is possible apply the product undershadow and in ventilated area.
Do not apply the product during rain.
Protect newly applied material from rain, etc. until dully hardened.
During storage, if the product has been exposed to negative temperatures, it mustbe transported in a warm area and must be left to come back to normal condition.Under no circumstances do not warm the product by exposing it to flame.
-
8/9/2019 Igol A
3/3
3 3/3Igol A
Value Base All technical data stated in this Product Data Sheet are based on laboratory tests.Actual measured data may vary due to circumstances beyond our control.
Local Restrictions Please note that as a result of specific local regulations the performance of thisproduct may vary from country to country. Please consult the local Product DataSheet for the exact description of the application fields.
Health and SafetyInformation
For information and advice on the safe handling, storage and disposal of chemicalproducts, users shall refer to the most recent Material Safety Data Sheet containingphysical, ecological, toxicological and other safety-related data.
Legal Notes The information, and, in particular, the recommendations relating to the applicationand end-use of Sika products, are given in good faith based on Sika's currentknowledge and experience of the products when properly stored, handled andapplied under normal conditions in accordance with Sikas recommendations. Inpractice, the differences in materials, substrates and actual site conditions are suchthat no warranty in respect of merchantability or of fitness for a particular pur pose,nor any liability arising out of any legal relationship whatsoever, can be inferredeither from this information, or from any written recommendations, or from any otheradvice offered. The user of the product must test the products suitability for t heintended application and purpose. Sika reserves the right to change the propertiesof its products. The proprietary rights of third parties must be observed. All ordersare accepted subject to our current terms of sale and delivery. Users must alwaysrefer to the most recent issue of the local Product Data Sheet for the productconcerned, copies of which will be supplied on request.
Sika Hellas ABEE
15 Protomagias Str.GR 145 68 KryoneriAthens-Greece
Phone +30 210 8160600
Fax +30 210 8160606Email: [email protected]