IESNA LM79-2008 Test Report TÜV SÜD America TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005 Page 1 NRG_F_10.04 TÜV SÜD America is accredited under the NVLAP EEL program. Telephone: 678-341-5900 www.tuvamerica.com Confidential Report Lab Code: 500065-0 NRG_F_10.04, Rev. 0, Effective: 2012-01-19 Photometric Testing and Evaluation in Accordance with LM79-2008 Report Prepared for: Jeff Goldstein President Lamar Lighting Company Inc. 485 Smith Street Farmingdale, NY 11735 United States Telephone: (631) 777-7700 Sample Tested: VOL24HFA30 / VL24HFA30 (no motion sensor) Manufacturer: Lamar Lighting Company Inc. Technical Report Number: JI1308013-2-LM79 Report Issue Date: August 29 th 2013 Total Number of Pages: 11 (including this page) Report Prepared by: Report Reviewed by: Byrd Evans Bryan Cubitt TÜV SÜD Project Handler TÜV SÜD Program Manager

Upload: others

Post on 23-Aug-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IESNA LM79 Test Report - LaMar LED...IESNA LM79-2008 TEST REPORT Report# JI308013-2-LM79 August 29, 2013 TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

IESNA LM79-2008 Test Report

TÜV SÜD America

TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

Page 1

NRG_F_10.04

TÜV SÜD America is accredited under the NVLAP EEL program.

Telephone: 678-341-5900 www.tuvamerica.com Confidential Report Lab Code: 500065-0

NRG_F_10.04, Rev. 0, Effective: 2012-01-19

Photometric Testing and Evaluation in Accordance with LM79-2008

Report Prepared for:

Jeff Goldstein President

Lamar Lighting Company Inc.

485 Smith Street Farmingdale, NY 11735

United States

Telephone: (631) 777-7700

Sample Tested: VOL24HFA30 / VL24HFA30 (no motion sensor) Manufacturer: Lamar Lighting Company Inc.

Technical Report Number: JI1308013-2-LM79 Report Issue Date: August 29th 2013

Total Number of Pages: 11 (including this page)

Report Prepared by: Report Reviewed by:

Byrd Evans Bryan Cubitt

TÜV SÜD Project Handler TÜV SÜD Program Manager

Page 2: IESNA LM79 Test Report - LaMar LED...IESNA LM79-2008 TEST REPORT Report# JI308013-2-LM79 August 29, 2013 TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

IESNA LM79-2008 TEST REPORT

Report# JI308013-2-LM79

August 29, 2013

TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

Page 2

NRG_F_10.04

TÜV SÜD America is accredited under the NVLAP EEL program.

Telephone: 678-341-5900 www.tuvamerica.com Confidential Report Lab Code: 500065-0

NRG_F_10.04, Rev. 0, Effective: 2012-01-19

Summary of Key Test Results

Model# VOL24HFA30

Manufacturer Lamar Lighting Company TÜV Sample# 883-1

Date of Test August 22nd 2013

Notes: Tested in FBU orientation (Fixture-Base-Up)

Parameter Measured Result

Luminous Flux 2097.0 Lumens

Input Power 28.40 Watts

Efficacy 73.85 Lumens/Watt

C.C.T. 3107 K

C.R.I. (Ra) 85.5

Beam Angle 93.5°

Stabilization Time 60 minutes The above results are recorded / derived from measurements in accordance with LM79-08

Page 3: IESNA LM79 Test Report - LaMar LED...IESNA LM79-2008 TEST REPORT Report# JI308013-2-LM79 August 29, 2013 TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

IESNA LM79-2008 TEST REPORT

Report# JI308013-2-LM79

August 29, 2013

TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

Page 3

NRG_F_10.04

TÜV SÜD America is accredited under the NVLAP EEL program.

Telephone: 678-341-5900 www.tuvamerica.com Confidential Report Lab Code: 500065-0

NRG_F_10.04, Rev. 0, Effective: 2012-01-19

TABLE OF CONTENTS

Test Results ..............................................................................................................................................................4

Spectral Flux and Chromaticity Diagram .................................................................................................................5

Zonal Lumen Summary ............................................................................................................................................5

Illuminance Plots ......................................................................................................................................................6

Candela Plots ...........................................................................................................................................................6

Candela Tabulation ..................................................................................................................................................7

Candela Tabulation ..................................................................................................................................................8

ISTMT Temperature Measurement .........................................................................................................................9

Photometric Testing Information ..........................................................................................................................10

Equipment List: ......................................................................................................................................................11

Page 4: IESNA LM79 Test Report - LaMar LED...IESNA LM79-2008 TEST REPORT Report# JI308013-2-LM79 August 29, 2013 TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

IESNA LM79-2008 TEST REPORT

Report# JI308013-2-LM79

August 29, 2013

TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

Page 4

NRG_F_10.04

TÜV SÜD America is accredited under the NVLAP EEL program.

Telephone: 678-341-5900 www.tuvamerica.com Confidential Report Lab Code: 500065-0

NRG_F_10.04, Rev. 0, Effective: 2012-01-19

Photometric Results VOL24HFA30

Integrating Sphere Goniophotometer Total Luminous Flux (Lumens) 2097.0 2117.9 Luminous Efficacy (Lumens/Watt) 73.85 74.68 Total Radiant Flux (Watts) 6.80 - Correlated Color Temperature (CCT) 3107 - Color Rendering Index (CRI – Ra) 85.5 - R9 Value 27.4 - Chromaticity (Chroma x / Chroma y) 0.4256 / 0.3932 - Chromaticity (Chroma u / Chroma v) 0.2479 / 0.3435 - Chromaticity (Chroma u’ / Chroma v’) 0.2479 / 0.5153 - Duv Value 0.0032 -

Electrical Results VOL24HFA30

Integrating Sphere Goniophotometer Input Power (Watts) 28.40 28.36 Input Voltage (Volts AC) 119.96 120.04 Input Current (Amps) 0.239 0.240 Power Factor 102V / 277V 0.989 / 0.874 0.993 Input Frequency (Hertz) 60.0 60.0 A-THD (Current %) 120V/277V 9.20% / 18.28% 9.22%

Additional Parameters VOL24HFA30

Integrating Sphere Goniophotometer Stabilization Time (Light and Power) 60 minutes 58 minutes

Test Geometry Configuration 4π Type C

Spectroradiometer Labsphere CDS1100 Gigahertz Optik P9801 Ambient Temperature 25.1°C 24.7°C ISTMT (In-Situ Temperature Measurement) 58.2°C Spacing Criteria 1.36 (0°- 180°) / 1.18 (90°- 270°)

Test Results – The following results were obtained after stabilization of the sample in accordance with the requirements set forth in section 5.0 of IES LM79-2008. Stability is achieved when the variation of 3 readings of light output and electrical power over a period of 30 minutes, taken 15 minutes apart, is less than 0.5%.

Page 5: IESNA LM79 Test Report - LaMar LED...IESNA LM79-2008 TEST REPORT Report# JI308013-2-LM79 August 29, 2013 TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

IESNA LM79-2008 TEST REPORT

Report# JI308013-2-LM79

August 29, 2013

TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

Page 5

NRG_F_10.04

TÜV SÜD America is accredited under the NVLAP EEL program.

Telephone: 678-341-5900 www.tuvamerica.com Confidential Report Lab Code: 500065-0

NRG_F_10.04, Rev. 0, Effective: 2012-01-19

Spectral Flux and Chromaticity Diagram

Spectral Flux Chromaticity Diagram

Spectral response of the Radiant Flux (350nm to 850nm)

Tristimulus values (from page 4):

x / y = 0.4256 / 0.3932

The locations on the diagram of the tristimulus coordinates are indicated by the blue diamond.

Zonal Lumen Summary

Zone Lumens % Lamp / Luminaire 0 - 60 1396.7 65.9 %

60 - 90 558.5 26.4 % 0 - 90 1955.1 92.3 %

90 - 180 162.9 7.7 % 0 - 180 2118.0 100 %

Page 6: IESNA LM79 Test Report - LaMar LED...IESNA LM79-2008 TEST REPORT Report# JI308013-2-LM79 August 29, 2013 TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

IESNA LM79-2008 TEST REPORT

Report# JI308013-2-LM79

August 29, 2013

TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

Page 6

NRG_F_10.04

TÜV SÜD America is accredited under the NVLAP EEL program.

Telephone: 678-341-5900 www.tuvamerica.com Confidential Report Lab Code: 500065-0

NRG_F_10.04, Rev. 0, Effective: 2012-01-19

Test Results – Illuminance Plots

The following images depict the illuminance characteristics of the luminaire.

Beam Angle = 93.5° Field Angle = 152.8°

Test Results – Candela Plots The following images depict the luminous intensity distribution characteristics of the luminaire:

Isofootcandle Plot Isocandela Plot Polar Candela

Page 7: IESNA LM79 Test Report - LaMar LED...IESNA LM79-2008 TEST REPORT Report# JI308013-2-LM79 August 29, 2013 TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

IESNA LM79-2008 TEST REPORT

Report# JI308013-2-LM79

August 29, 2013

TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

Page 7

NRG_F_10.04

TÜV SÜD America is accredited under the NVLAP EEL program.

Telephone: 678-341-5900 www.tuvamerica.com Confidential Report Lab Code: 500065-0

NRG_F_10.04, Rev. 0, Effective: 2012-01-19

Test Results – Candela Tabulation

The table below displays the tabulated Candela measurements from the IES file: Horizontal (lateral) angles are shown in red across the top of the table, in increments of 22.5°. Vertical (longitudinal) angles are shown in blue down the side of the table, in increments of 2.5°.

0.0 22.5 45.0 67.5 90.0 112.5 135.0 157.5 180.0 202.5 225.0 247.5 270.0 292.5 315.0 337.5 360.0

0.0 618 618 618 618 618 618 618 618 618 618 618 618 618 618 618 618 618

2.5 619 618 619 623 618 619 617 616 616 614 614 617 613 616 616 616 619

5.0 619 618 618 622 615 617 616 615 616 612 610 612 607 612 613 615 619

7.5 618 617 616 618 611 613 613 614 614 609 605 605 600 606 608 612 617

10.0 617 616 613 613 605 607 610 612 613 607 599 597 591 597 603 610 617

12.5 615 614 608 605 596 600 605 610 611 603 592 586 580 587 596 606 616

15.0 614 611 602 595 586 591 599 606 607 597 584 575 567 575 588 602 613

17.5 611 608 595 584 573 580 591 600 603 590 575 562 553 562 580 597 611

20.0 605 602 586 571 559 567 582 595 598 584 563 547 537 548 569 591 605

22.5 599 594 576 557 543 553 571 589 594 577 551 531 519 532 558 582 598

25.0 590 586 565 541 526 538 560 581 587 569 538 514 500 515 546 573 590

27.5 580 575 552 525 507 520 548 573 578 559 525 496 479 497 532 562 580

30.0 568 563 538 506 486 502 535 562 569 548 511 476 457 478 516 549 568

32.5 555 550 523 487 464 482 521 550 557 536 496 455 435 457 501 535 554

35.0 540 535 507 466 440 461 506 537 544 522 480 433 411 436 484 520 540

37.5 524 519 490 444 416 440 490 523 529 507 463 411 386 414 466 503 524

40.0 508 502 472 421 391 418 473 507 513 490 445 388 361 391 447 486 508

42.5 491 485 453 398 365 395 455 490 498 473 427 365 336 368 428 468 491

45.0 474 467 433 373 339 372 436 473 481 456 408 342 311 344 408 450 474

47.5 457 449 413 349 313 349 417 457 466 439 388 319 286 320 388 432 457

50.0 440 430 392 324 287 325 397 440 450 422 369 296 261 297 368 414 440

52.5 423 412 371 299 262 301 377 423 433 405 349 273 237 273 347 396 423

55.0 407 395 350 274 237 277 358 405 416 388 330 250 213 249 327 379 406

57.5 389 377 329 249 213 254 338 388 400 371 310 227 191 227 306 361 389

60.0 372 359 308 226 190 230 318 371 383 354 291 206 170 204 286 344 372

62.5 355 341 287 202 168 208 298 354 366 336 272 185 150 183 266 327 355

65.0 337 324 267 180 147 186 278 336 348 319 253 165 131 162 246 309 337

67.5 318 305 247 158 127 164 259 318 330 302 235 145 113 142 227 291 318

70.0 299 287 227 138 108 144 240 300 312 284 216 127 97 124 209 273 299

72.5 280 269 207 118 90 125 221 282 293 266 199 110 81 106 191 255 280

75.0 261 250 189 101 73 107 203 264 275 249 182 94 66 90 173 237 261

77.5 242 232 171 84 58 91 185 246 256 231 165 80 53 76 156 219 242

80.0 224 214 154 70 45 76 167 228 238 214 149 67 40 63 141 202 223

82.5 205 197 137 57 33 62 151 211 220 198 133 55 30 51 125 185 205

85.0 187 179 122 46 23 51 135 194 202 181 119 45 21 42 111 168 187

87.5 168 162 107 37 14 41 120 176 184 165 105 36 13 33 98 152 168

90.0 150 145 94 29 6 33 105 160 166 149 93 29 6 27 86 136 150

Maximum Candela = 623 at Horizontal 67.5°, Vertical: 2.5°

Page 8: IESNA LM79 Test Report - LaMar LED...IESNA LM79-2008 TEST REPORT Report# JI308013-2-LM79 August 29, 2013 TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

IESNA LM79-2008 TEST REPORT

Report# JI308013-2-LM79

August 29, 2013

TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

Page 8

NRG_F_10.04

TÜV SÜD America is accredited under the NVLAP EEL program.

Telephone: 678-341-5900 www.tuvamerica.com Confidential Report Lab Code: 500065-0

NRG_F_10.04, Rev. 0, Effective: 2012-01-19

Test Results – Candela Tabulation

The table below displays the tabulated Candela measurements from the IES file: Horizontal (lateral) angles are shown in red across the top of the table, in increments of 22.5°. Vertical (longitudinal) angles are shown in blue down the side of the table, in increments of 2.5°.

0.0 22.5 45.0 67.5 90.0 112.5 135.0 157.5 180.0 202.5 225.0 247.5 270.0 292.5 315.0 337.5 360.0

92.5 133 128 81 23 6 26 92 143 149 133 81 23 6 21 74 120 133

95.0 117 113 70 19 6 21 80 127 132 118 70 19 6 17 64 105 116

97.5 101 98 60 15 6 17 69 112 116 104 61 15 6 14 55 92 101

100.0 86 85 51 13 7 14 59 97 101 91 52 13 6 12 47 79 86

102.5 73 72 43 11 7 12 50 84 87 78 44 11 6 10 39 67 73

105.0 61 60 36 9 7 10 42 72 74 67 37 10 7 9 33 56 61

107.5 50 50 30 8 7 9 36 60 62 56 31 9 7 8 28 47 50

110.0 42 41 25 7 7 8 30 50 52 47 26 8 7 7 23 39 42

112.5 34 34 21 7 7 7 25 41 43 39 22 7 7 7 19 32 34

115.0 29 28 17 7 7 7 20 34 35 32 18 7 7 7 16 26 29

117.5 24 23 14 7 7 7 17 28 29 26 15 7 7 7 14 22 24

120.0 21 19 12 7 7 7 14 23 24 22 13 7 7 7 12 18 21

122.5 18 16 10 7 7 7 12 19 21 18 11 7 7 7 10 16 18

125.0 15 14 8 7 7 7 11 16 18 16 10 7 7 7 8 14 15

127.5 14 13 8 7 7 7 9 14 15 13 8 7 7 7 8 12 14

130.0 13 11 8 7 7 7 8 12 13 12 7 7 7 7 8 11 13

132.5 11 9 8 8 7 8 8 11 12 11 8 7 7 7 8 9 11

135.0 9 8 8 8 8 8 8 9 11 9 8 8 7 8 8 8 9

137.5 9 9 8 8 8 8 8 8 9 8 8 8 8 8 8 8 9

140.0 9 9 8 8 8 8 8 9 9 8 8 8 8 8 8 9 9

142.5 9 9 8 8 8 8 9 9 9 9 8 8 8 8 8 9 9

145.0 9 9 8 8 8 8 9 9 9 9 8 8 8 8 8 9 9

147.5 9 9 9 8 8 8 9 9 9 9 8 8 8 8 9 9 9

150.0 10 9 9 8 8 8 9 9 9 9 8 8 8 8 9 9 10

152.5 10 9 9 8 8 9 9 9 9 9 8 8 8 8 9 9 10

155.0 10 9 9 8 8 9 9 9 9 9 8 8 8 8 9 9 10

157.5 10 9 9 9 9 9 9 9 9 9 9 8 8 8 9 9 10

160.0 10 9 9 9 9 9 9 9 9 9 9 8 8 9 9 9 10

162.5 10 9 9 9 9 9 9 9 9 9 9 9 8 8 9 9 10

165.0 10 9 9 9 8 9 9 9 9 9 9 8 8 9 9 9 10

167.5 10 10 9 9 9 9 9 9 10 9 9 9 8 9 9 9 10

170.0 10 10 9 9 9 9 9 9 10 9 9 9 9 9 9 9 10

172.5 10 10 9 9 9 9 9 10 10 9 9 9 9 9 9 9 10

175.0 10 10 9 9 9 9 9 10 10 9 9 9 9 9 9 9 10

177.5 10 10 10 9 9 9 10 10 10 9 9 9 9 9 9 10 10

180.0 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9

Page 9: IESNA LM79 Test Report - LaMar LED...IESNA LM79-2008 TEST REPORT Report# JI308013-2-LM79 August 29, 2013 TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

IESNA LM79-2008 TEST REPORT

Report# JI308013-2-LM79

August 29, 2013

TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

Page 9

NRG_F_10.04

TÜV SÜD America is accredited under the NVLAP EEL program.

Telephone: 678-341-5900 www.tuvamerica.com Confidential Report Lab Code: 500065-0

NRG_F_10.04, Rev. 0, Effective: 2012-01-19

ISTMT Temperature Measurement

ISTMT temperature measurement at thermal stabilization (8 hours continuous operation). Thermocouple locations (shown below) are in accordance with manufacturers recommended / stated guidelines for TMP - Temperature Measurement Point.

“LED” Thermocouple location at TMP

Test Results for: VOL24HFA30

LED TMP Temperature 58.2°C Reported temperatures are maximum temperatures. All temperatures are normalized to 25°C ambient.

Test Equipment

Description Manufacturer / Model# TÜV SÜD Ref# Calibration Due Date

Thermometer Fluke 52-II ATLE0008 11/17/2013 This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production.

This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government

Page 10: IESNA LM79 Test Report - LaMar LED...IESNA LM79-2008 TEST REPORT Report# JI308013-2-LM79 August 29, 2013 TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

IESNA LM79-2008 TEST REPORT

Report# JI308013-2-LM79

August 29, 2013

TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

Page 10

NRG_F_10.04

TÜV SÜD America is accredited under the NVLAP EEL program.

Telephone: 678-341-5900 www.tuvamerica.com Confidential Report Lab Code: 500065-0

NRG_F_10.04, Rev. 0, Effective: 2012-01-19

Continued…..

TÜV SÜD Photometric Testing Information

Testing is performed in accordance with the procedures outlined in IESNA LM79-2008. The sample is evaluated for photometric and electrical characteristics using an integrating sphere and a goniophotometer, located in an accredited, temperature and humidity-controlled, draft free photometric laboratory.

Sphere Geometry The integrating spheres used for measurement utilize a “4π geometry” configuration in accordance with section 9 of IES LM-79-2008 and is applicable for all types of SSL products (directional and non-directional light projections). The spectroradiometer is an array-type detector manufactured and calibrated by Labsphere (Model# CDS1100).

Self-Absorption Correction The integrating sphere uses self-absorption correction to eliminate errors due to mismatches between the standard reference lamp and the test samples being measured. This auxiliary correction lamp is a halogen type lamp powered by a calibrated Lamp Power Supply manufactured and calibrated by Labsphere (model LPS150). Ambient temperature is measured using a thermocouple located inside the integrating sphere at the same height as the sample under test (UUT) and not more than 1 meter in horizontal distance away from the sample (section 2.2 of LM79-2008). The thermocouple is located behind a baffle in order to eliminate any direct optical radiation from the sample under test.

Sample Stabilization The sample (UUT) is placed inside the integrating sphere and powered by a regulated and conditioned alternating or direct current supply. The stabilization times shown on the results pages of this report denote the time of the 3rd measurement (of the 3 consecutive readings) since this is the minimum time that the sample is assumed to have taken to reach stabilization in accordance with section 5.0 of LM79-2008.

Sphere Calibration The integrating sphere is calibrated using a quartzline halogen lamp with the following specifications:

Manufacturer: EYE Lighting International Model# J94/JD28V75W Voltage = 28.0 Volts DC Wattage = 75.0 Watts Calibration Current = 2.679 Amperes Luminous Flux = 1685 Lumens Calibration Date = 2-17-2011 (calibrated by Labsphere – NIST traceable).

Page 11: IESNA LM79 Test Report - LaMar LED...IESNA LM79-2008 TEST REPORT Report# JI308013-2-LM79 August 29, 2013 TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

IESNA LM79-2008 TEST REPORT

Report# JI308013-2-LM79

August 29, 2013

TÜV SÜD America, Inc. 5945 Cabot Parkway, Suite 100, Alpharetta GA 30005

Page 11

NRG_F_10.04

TÜV SÜD America is accredited under the NVLAP EEL program.

Telephone: 678-341-5900 www.tuvamerica.com Confidential Report Lab Code: 500065-0

NRG_F_10.04, Rev. 0, Effective: 2012-01-19

This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production.

This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government

TÜV SÜD Photometric Testing Information (continued)

Goniophotometer The Goniophotometer is a Type C optical measurement system in accordance with section 9.3.1 of IESNA LM79-2008.

Goniophotometer Calibration The Goniophotometer is calibrated using a frosted tungsten filament FDS/DZE lamp with the following specifications:

Manufacturer: General Electric Part Number: CSB-110 Lamp Number: 105-A Voltage: 16.71 Volts DC Wattage: 150.0 Watts Calibration Current: 4.847 Amperes Luminous Intensity: 166.3 Candelas Calibration Date: 11-07-2011 (NIST traceable)

TÜV SÜD Test Equipment List:

TÜV SÜD Sphere System – contains the following:

Description Manufacturer / Model# TÜV SÜD Ref# Calibration Due Date

Integrating Sphere Labsphere LM760 SPH003 weekly

Spectroradiometer Labsphere CDS1100 ATLE0048 9/7/2016

Power Analyzer Yokogawa WT210 ATLE0058 3/7/2014

Power Source Chroma 61602 AC003 N/A

Thermometer Fluke 52-II ATLE0008 11/17/2013

TÜV SÜD Goniophotometer System – contains the following:

Goniophotometer M.E. GONC01 GON001 weekly

Spectroradiometer Gigahertz Optik P9801 GIG001 weekly

Power Analyzer Yokogawa WT210 ATLE0031 11/16/2013

Power Source Chroma 61602 AC006 N/A