IESNA LM79 - 2008 Test Report Photometric testing and evaluation in accordance with LM79-2008 Laboratory : Ilmenau University of Technology Group of Lighting Engineering Prof.-Schmidt-Str. 26 98693 Ilmenau / Germany Report prepared for: R. STAHL Schaltgeräte GmbH Nordstraße 10 99427 Weimar / Germany Report number: LM7920151016-F / 02 Testing performed by : ILEXA GbR Werner-von-Siemens-Straße 4a 98693 Ilmenau / Germany Tel.: (+49) 3677 / 466 33 0 Fax: (+49) 3677 / 466 33 14 Internet: www.ilexa.de Sample tested: 6125/...4-21..-...1-... Manufacturer: R. STAHL Schaltgeräte GmbH

Upload: others

Post on 06-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

IESNA LM79 - 2008 Test Report

Photometric testing and evaluation in accordance with LM79-2008

Laboratory : Ilmenau University of TechnologyGroup of Lighting EngineeringProf.-Schmidt-Str. 2698693 Ilmenau / Germany

Report prepared for: R. STAHL Schaltgeräte GmbHNordstraße 1099427 Weimar / Germany

Report number: LM7920151016-F / 02

Testing performed by : ILEXA GbRWerner-von-Siemens-Straße 4a98693 Ilmenau / Germany

Tel.: (+49) 3677 / 466 33 0Fax: (+49) 3677 / 466 33 14Internet: www.ilexa.de

Sample tested: 6125/...4-21..-...1-...

Manufacturer: R. STAHL Schaltgeräte GmbH

Table of contents

1. Description of test sample................................................................................................31.1. General Informationen.....................................................................................................31.2. Manufacturer specifications..............................................................................................31.3. Pictures............................................................................................................................32. Scope of testing...............................................................................................................43. Equipment........................................................................................................................44. Additional information.......................................................................................................45. Test Results.....................................................................................................................56. Results goniophotometer.................................................................................................66.1. Illuminance plots..............................................................................................................66.2. Candela plots...................................................................................................................77. Results spectroradiometer...............................................................................................97.1. Relative spectral distribution............................................................................................97.2. Chromaticity diagram.....................................................................................................10

ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14

Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 2 of 10

General Information

This report may not be reproduced except in full without permission of ILEXA GbR.

This technical report may only be quoted in full. Any use for advertising purposes must begranted in writing. This report is the result of a single examination of the object in questionand is not generally applicable evaluation of the quality of other products in regularproduction.

________________________________

Wladimir JordanowILEXA GbR president

1. Description of test sample

1.1. General Informationen

Sample received: 12.10.2015

Manufacturer: R. STAHL Schaltgeräte GmbHNordstraße 1099427 Weimar / Germany

Model number: 6125/...4-21..-...1-...

Model type: Luminaire

Length / Width / Height: 600 mm / 400 mm / 180 mm

1.2. Manufacturer specifications

Voltage (V): 230 AC

Frequency (Hz): 50

1.3. Pictures

Figure 1: Luminaire housing as measured Figure 2: Luminaire LED panel with optics

ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14

Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 3 of 10

2. Scope of testing

‐Photometric and electrical testing in accordance with IESNA LM 79 2008 IES (ApprovedMethod: Electrical and Photometric Measurements of Solid-State Lighting Products).All measurements are made using the goniophotometer / spectroradiometer test method.

The spectral values are measured at a given direction with vertikal angle theta= 0°.

Date of test: 14.10.2015

Report and test prepared by: Kranhold / ILEXA GbR

3. Equipment

‐Testing is performed in accordance with the procedures outlined in IESNA LM79 2008.The sample is evaluated for photometric and electrical characteristics using a goniophotometer,located in an temperature - controlled, draft free photometric laboratory.

Item Manufacturer Model Calibration due

Goniophotometer TechnoTeam RiGo801 yearly

Spectroradiometer Jeti specbos 1211 yearly

Power Supply Statron AG BE2/01H-IP-R20-B N/A

Digital Power Meter Yokogawa WT110 N/A

Table 1: Test Instrumentation

4. Additional information

(none)

ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14

Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 4 of 10

5. Test Results

The results were obtained after stabilization of the sample in accordance with the requirementsset forth in section 5.0 of IES LM79-2008.

Goniophotometer Spectroradiometer

Total luminous flux (lm) 11763 -

Luminous efficacy (lm/W) 98 -

Correlated color temperature (CCT) - 5629

Color rendering index (CRI - Ra) - 73,34

Chromaticity (x / y) - 0,3295 / 0,3482

Table 2: Photometric results

Input power (W) 119,5

Input voltage (VAC) 230,1

Input current (A) 0,5319

Input frequency (Hz) 50

Table 3: Electrical results

Orientation (burning position) during test horizontal

Prior operation time (minutes) 91

Stabilization time (minutes) 30

Total operating time (minutes) 157

Ambient temperature (°C) 24,0

Table 4: Additional Parameters

ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14

Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 5 of 10

6. Results goniophotometer

6.1. Illuminance plots

Figure 3: Isolux diagram (mounting height 3m)

ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14

Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 6 of 10

0 2-2 4 m-4 m

0 0

2 m 2 m

-2 -2

16

1616

16 32

32

32

32

64 64

64

64

64

64

64

125

125

125

125

125

125

250

250

250

250

ti lt angle :

swivel angle:

0,0

0,0

°

°

mounting height:

orientation :

3,0

0,0

m

°

light loss factor : 1,0

6.2. Candela plots

Figure 4: 3D - luminous intensity distribution ( point of view 1 )

Figure 5: 3D - luminous intensity distribution ( point of view 2 )

ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14

Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 7 of 10

Figure 6: Polar candela distribution

Figure 7: Cartesian candela distribution

ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14

Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 8 of 10

C0,0-C180,0 C90,0-C270,0

90°90°

75°

60°

45°

30° 15° 0° 15° 30°

45°

60°

75°

2000

3000

4000

cd

0

1000

2000

3000

4000

5000

0°45° 45°90° 90°135° 135°180° 180°

C0,0 C90,0

I (cd)

beam angle

7. Results spectroradiometer

7.1. Relative spectral distribution

Figure 8: Relative spectral distribution

ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14

Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 9 of 10

0 2 4 6 8 10 12

0

0,1

0,2

0,3

0,4

0,5

0,6

0,7

0,8

0,9

1

Wavelength [nm]

Re

lative

sp

ectr

al d

istr

ibu

tio

n

350 400 450 500 550 600 650 700 750 800 850 900 950 1000

0,0

0,1

0,2

0,3

0,4

0,5

0,6

0,7

0,8

0,9

1,0

Wavelength [nm]

Re

lative

sp

ectr

al d

istr

ibu

tio

n

7.2. Chromaticity diagram

Figure 9: Chromaticity diagram

Tristimulus Value

x 0,3295

y 0,3482

The location on the diagram of the tristimulus coordinates are indicated by the blue axes on cross.

ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14

Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 10 of 10