© 2012 IBM Corpora.on
IBM Storwize V7000 Unified Overview
IBM Systems Storage
© 2012 IBM Corpora.on Agenda
§ Overview § Architecture & Concepts § Hardware & Components § Cabling § SoDware & Features overview § Ac.ve Cloud Engine § Planning & Implementa.on § Online code upgrade § Security & Authen.ca.on § An.-‐Virus support § Backup & Recovery (Snapshot, NDMP & Tivoli Storage Manager) § Hierarchical Storage Manager § Asynchronous Remote Replica.on § File Clone § WAN caching (Statement Of Direc.on)
2 Many thanks to Jim Kelly, Justin Heather & Sandy Leadbeater for their suggestions, comments and corrections
This presenta=on is focused on Storwize V7000 Unified. To find more informa=on and details on Storwize V7000, please check this slide deck:
hTp://caTail.boulder.ibm.com/caTail/?source=v#[email protected]/files/EB77F620BCAF3DDA9C7C458F093F23B6
© 2012 IBM Corpora.on
3
IBM Active Cloud
Engine™
File Support
Easy Tier
RAID
Innovative GUI
SAN
Virtualization
Snapshots
One Year Later… Technology Integra=on Con=nues Storwize V7000 Unified Storage
Leveraging the best of IBM storage technologies in a midrange disk system
Clustered Systems
© 2012 IBM Corpora.on What’s different?
§ Ac.ve/Ac.ve Unified Namespace across all file modules § IBM Ac.ve Cloud Engine™ technology delivers automated storage efficiency capabili.es – True policy-‐based management of files – With user-‐defined policies!
§ Based on highly successful Storwize V7000 block storage system § Fully integrated user interface for block and file data simplifies management
– Not a “unified” launcher for two different interfaces § Simple USB key based ini.al setup
– Extends successful Storwize V7000 approach § Built-‐in IBM Tivoli Storage Manager client simplifies
– backup to TSM server – and Hierarchical Storage Management to tape or virtual tape library with dedu-‐plica.on – System also supports NDMP for third-‐party backup clients
4
© 2012 IBM Corpora.on
OVERVIEW
5
© 2012 IBM Corpora.on
§ Network File Serving – NFS v2/v3, CIFS, HTTP, FTP & SCP – Clustered parallel file system – Quotas Management ● User, group and fileset level quotas ● SoD limits, hard limits, grace periods
§ Block Access – FCP, FCoE & iSCSI – Disk Storage Virtualisa.on Engine
§ Scalability and Performance – 2 file modules – Up to 960 hard disk drives + external virtualisa.on – Directly aTached to Storwize V7000*
§ Informa.on Lifecycle Management – Policy driven placement, movement, migra.on &
dele.on of files – Storage .ering (Disk-‐to-‐Disk-‐to-‐Tape) – Integrated HSM agent to migrate inac.ve files to
tape or Deduplica.on VTL
Overview
6
Clustered parallel file system Active Cloud Engine
CIFS NFS HTTPS FTP
Storage Virtualisa=on Engine iSCSI FCP
SCP NDMP
NIS/ AD
NFS
HTTPS
CIFS
DFS IP layer
iSCSI
SAN layer
FCP
Shared Integrated Disk
Storage Pools
IBM Storwize V7000U
(*) to the first IO group, clustering of Storwize V7000 mul.ple control enclosures s.ll requires FCP and/or FCoE connec.vity
© 2012 IBM Corpora.on Overview (cont.)
§ Data Protec.on & Security – File Access Protocols ● Up to 256 snapshots per file system and/or filesets ● Asynchronous IP Remote replica.on for file access ● Integrated TSM 6.2 Backup/Archive client or NDMP ● “Scan on access” & “scan on demand” An.virus
– Block Access Protocols ● Point-‐In-‐Time Copy (FlashCopy/snapshot) ● Virtual Disk Mirroring ● Sync. & Async. Remote Replica.on for block access ● FlashCopy Manager for Windows, VMware, Linux, AIX, Solaris & HP-‐UX ● VMware Site Recovery Manager
§ Centralized Management & Administra.on – GUI & CLI – Centralized alert & event log – Event no.fica.ons via email or SNMP – Performance Monitoring
§ RAS – Centralized monitoring of en.re system via System Health Center – Call home and remote service features – Fully redundant capability in all components for High Availability
7
© 2012 IBM Corpora.on SoZware & Hardware Components
8
CIFS NFS HTTPS FTP SCP NDMP Cluster Manager
Clustered Trivial Database (CTDB)
File Access Protocols
Hardware Servers: IBM System x 3650M3 (x2) Storage: Storwize V7000
Base Opera=ng System RedHat Enterprise Linux 6 (64bit)
WAN caching Panache
HSM HSM agent
Backup & Recovery TSM client
Security
Disaster Recovery Remote Replica.on
Parallel File System &
Ac=ve Cloud Engine IBM GPFS
An=-‐Virus Scan GUI (web) & CLI Management Interfaces
Monitoring agents
AD/LDAP/NIS server
TSM server
TSM server
AV server
Remote Storwize V7000U
Storwize V7000U Admins
Call home IBM Support
Backup & Migra=on Protocol
• Symantec Netbackup • Legato Networker • CommVaultSampana
• Symantec • McAfee
Rapid Data Recovery Snapshots
ILM Remote Storwize
V7000U
© 2012 IBM Corpora.on Understanding the IO stack
Server
Client/Server Server
Block Access
“Som
e form
of” Unifie
d Storage A LUN = a file
In the File System
Na=ve File Access
Network Ab
ache
d Storage File System
Logical Volume
Volume/Disk Group
Na=ve Block Access
LUN/Volume
Disk Sub
system
Storage Pool/Aggregate
RAID Array
Disk Subsystem/Appliance Controller
Device/RAID Adapters/Controller (With or without ASIC & CPU)
Disk Drawers
Disk Drives
9
NetApp &
IBM Nseries
WAFL
FCP & iSCSI
Na=
ve Block Access NFS & CIFS
Na=
ve File Access
Server
Filer presen=ng a LUN on top of his File System
Via FCP of iSCSI FCP & iSCSI
Block Ac
cess
File Access
File System
Logical Volume
Volume/Disk Group
File Access
File System
Logical Volume
Volume/Disk Group
Each layer adds latency... Why emulating FCP & iSCSI here?
... When you could be doing it natively several milliseconds earlier? Directly from here
© 2012 IBM Corpora.on
ARCHITECTURE & CONCEPTS
11
© 2012 IBM Corpora.on Storwize V7000 Unified Architecture
External Local Area Network (1GbE & 10GbE)
Each File Module has the Interface, Storage & Management role func=ons Installed & Ac=vated
(*) only the management role func.on is ac.ve on 1 File Module and Standby on the other File Module All Interface & Storage role func.ons are ac.ve at the same .me on both File Modules
241
System Storage
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
File Module
Storage Module
File Module
Global Name Space
Single Management Interface
To manage both file & block access
12
Ac=ve Tiering
1 2
3 4
Storwize V7000 UnifiedManagement role Ac.ve* Storage role
Interface role 1 2
3 4
Storwize V7000 Unified Management role Standby* Storage role
Interface role
No Single Point Of Failure
© 2012 IBM Corpora.on
13
Storwize V7000 Storage module (2076-1/3xx)
Control Enclosure
Architecture
Storwize V7000 Unified File module (2073)
Storwize V7000 Unified File module (2073)
Storwize V7000 Storage module (2076-2xx) 0-4 Expansion Enclosure(s)
Storwize V7000 Storage module (2076-2xx) 0-5 Expansion Enclosure(s)
SAS 2 x 4 x 6Gbps
SAS 2 x 4 x 6Gbps
Point-‐to-‐point FCP 2 x 8Gbps
Point-‐to-‐Point FCP 2 x 8Gbps
iSCSI 4 x 10GbE
iSCSI &
Management 4 x 1GbE
FCP 4 x 8Gbps
2 x 10GbE
2 x 1GbE
Management, NFS, CIFS, HTTPS, FTP, SCP, NDMP, remote replica=on …
2 x 10GbE
2 x 1GbE
Management, NFS, CIFS, HTTPS, FTP, SCP, NDMP, remote replica=on …
Na=ve block Access File Access File Access
Each File Module has a direct FC connec.on to each Controller
in a Storage Module
© 2012 IBM Corpora.on Terminology
§ A File is made up of metadata and data
§ A Fileset is a logical sub-‐tree of a file system – Provides more granularity, flexibility and manageability for features
such as Quota management, Snapshots, Policies, etc. – In many respects behaves like an independent file system
§ A File System is created using Network Shared Disk (a LUN) from 1 or more storage pools
§ A Storage pool is a group of NSDs within a file system
§ A Network Shared Disk (NSD) a Logical Unit Number (LUN) assigned to a number of File Modules
14
© 2012 IBM Corpora.on Storage Pools
§ Storage pools are a collec.on of resources allowing you to group mul.ple Network Shared Disks (NSD) & mul.ple storage subsystems into a single file system
§ Storage pools allow you to perform complex opera.ons such as moving, mirroring, or dele.ng files across mul.ple storage devices, providing storage virtualiza.on and a single management context
§ Storage pools provide you with a method to par..on file system storage for considera.ons such as – Improved price-‐performance by matching the cost of storage to the value of the data
– Improved performance by • Reducing the conten.on for premium storage
• Reducing the impact of slower devices • Allowing you to retrieve archived data when needed
– Improved reliability by providing for • Replica.on based on need • BeTer failure containment
• Crea.on of new storage pools as needed
15
© 2012 IBM Corpora.on Storage Pools (cont.)
There are 2 types of storage pools § Internal Storage Pools
– Meant for managing online storage resources – Maximum of 8 internal storage pools per file system
• 7 are available as op.onal user pools • 1 is required required as the system storage pool
– The Ac.ve Cloud Engine assigns file data to internal storage pools under these circumstances • During file crea.on the storage pool is determined by ACE’s the file placement policy
• ATributes of the file, such as file size or access .me, match the rules of a policy that directs the file to be migrated to a different storage pool
§ External Storage Pools – Intended for use as near-‐line storage, archival and/or backup opera.ons – Requires the use of a external storage management applica.on such as TSM – TSM/HSM is responsible for moving files on & off Internal Storage Pools from GPFS ● Files are recalled from the Library Manager upon the request of an applica.on opening it
© 2012 IBM Corpora.on Logical Structure of a File System
17
§ Up to 256 File Systems per Storwize V7000 Unified cluster
§ Max. 8PB per file system
§ Up to 3,000* filesets per File System
§ Up to 65,536 (216) sub-‐directories per directory
§ Up to 263 files per file system (4,294,967,296 = 232 currently tested)
§ File aTributes include folder name → File data can be moved to different storage pools
within the file system
File System
File Sets
Folders (*) Up to 3,000 dependent and 1,000 independent filesets: • An independent file set has a separate inode space, but shares physical storage with the remainder of the file system • A dependent file set shares the inode space, quota limits and snapshot capability of the containing independent file set
© 2012 IBM Corpora.on
18
Automa=c Tiered Storage
§ Informa9on Lifecycle Management means Tiering between internal Disk Pools
§ Hierarchical Storage Management means Tiering with external storage pool (usually tape) with file pointer leD in the File System
§ At mul.ple levels – Storage Pool level (A group of LUNs) – Fileset level (Define sub-‐trees of a File-‐System)
§ Using Policies for rule based management of files – Placement – Migra.on – Dele.on – Exclusion
§ Delivering – Scalability è billions of files – One global File-‐System name space across independent storage pools – Hierarchical storage based on files ● Files in the same directory can be in different pools ● Files placed in storage pools at create .me using policies ● Files moved between pools via automated policy-‐driven .ered storage
– Hierarchical to both disk & tape – Allows classifica.on of data according to Service Level Agreements
Tier 3
© 2012 IBM Corpora.on
HARDWARE & COMPONENTS
19
© 2012 IBM Corpora.on Base Configura=on
§ 6 up to 24 RU solu.on – When clustering mul.ple Storwize V7000 storage modules via a redundant SAN fabric
(via FCP or FCoE), we are be able to scale up to 84 RU (+ SAN connec.vity)
§ File modules are provided in a pair (cluster) § Same code as SONAS
– Storwize V7000U is like a SONAS appliance’s storage pod with Storwize V7000 control enclosure as a back-‐end storage subsystem, and the interface/management nodes embedded in the storage nodes
§ Each file module has all func.ons – Management node è a node is ac.ve while the other is
standby
– Interface node è both nodes are ac.ve – Storage node è both nodes are ac.ve and directly aTached to Storwize V7000
§ Direct redundant LAN connec.vity between both file modules
20
© 2012 IBM Corpora.on Full Configura=on & Scalability
§ Storwize V7000 Unified (Up to 84 Rack Units) – 2 File Modules – 4 Storage Modules – 960 internal hard disk drives (SSD, SAS & NL-‐SAS)
§ SONAS appliance (Up to 17 racks) – 30 Storage Nodes – 60 Interface Nodes – 7,200 internal hard disk drives (SAS & NL-‐SAS)
§ SONAS gateway (1 base rack + Disk Subsystems) – 10 Storage Nodes – 8 Interface Nodes – 10 XIV or SAN Volume Controller or Storwize V7000
§ GPFS – Max. Design Capacity: 134,217,728 Yobibytes (2107 Bytes) – Max. file size equals file system size – Up to 256 file systems per cluster – Up to 9,223,372,036,854,780,000 files (263) per file system – Up to 8192 nodes 21
(*) CIFS not supported with external virtualised capacity
è Far from using the full scalability of either SONAS or GPFS
1 2
3 4
Storwize V7000 Unified
241
System Storage
241
System Storage
System Storage
85
41
129
System Storage
85
41
129
241
System Storage
241
System Storage
241
System Storage
241
System Storage
System Storage
85
41
129
241
System Storage
1 2
3 4
Storwize V7000 Unified
© 2012 IBM Corpora.on
PCI
1
2
PCI
3
4
AC
DC
AC
DC
10Gb/s
1 2
3 4
Storwize V7000 Unified
§ IBM System x 3650M3 (2U) § Quad Core Intel® Xeon® E5620 (Westmere)
– 8 threads, 2.40 GHz, 12MB cache, 80W
§ 72GB DDR3 memory
Storwize V7000 Unified File Module
23
Management Ethernet (IMM)
Unused
Internal IP Network 2 x GbE ports
Directly connected to the partner File Module
External IP Network 2 x 10GbE ports Emulex CNA
External IP Network 2 x GbE ports
Internal SAN 2 x 8Gbps FC ports QLogic HBA directly connected to the Storage Module
DVD drive
2 x 500GB NL-‐SAS mirrored drives
Redundant PSU
Free/Unused PCIe slots
© 2012 IBM Corpora.on Storwize V7000 Unified Storage Module Storwize V7000 Enclosure
24
241
System Storage
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
600 GB 10K6Gb SAS
FRU 85Y5864
System Storage
85
41
129
§ Storwize V7000 enclosure (2U) – 2 Storage Bridge Bay (SBB) canisters for the electronics – Redundant power supplies ● 764W per PSU in the control enclosures ● 500W per PSU in the enclosure enclosures
– Internal drive bays ● Enclosure for 12 x 3.5” drives (NL-‐SAS)
● Enclosure for 24 Small Form-‐Factor 2.5” drives (SSD, SAS & NL-‐SAS)
Note: Both types may be mixed freely in the same subsystem.
© 2012 IBM Corpora.on
§ 1st enclosure is configured with 2 controller canisters – Intel Jasper Forest processor (SKU 4, EC3539, 4 cores, 8MB cache, 2.13 GHz, 65W) – 8 GB DDR3 memory
– Internal 32GB MLC SSD for boot and fire-‐hose dump – Both controller canisters communicate over an internal 8xPCIe Gen2 link in the mid-‐plane
Storwize V7000 Unified Storage Module Storwize V7000 control canister
25
CAUTION
31
42
Disconnect allsupply power forcomplete isolation
Disconnect allsupply power forcomplete isolation
42
31
CAUTION
31
42
42
31
CAUTION
Disconnect allsupply power forcomplete isolation
CAUTION
Disconnect allsupply power forcomplete isolation
231
4
21
1 2
2 1
13
2412
2 14 3 2 14 3
21 4321 43
12
1 2
LNK
Tx/Rx
10Gb/s
LNK
Tx/Rx
10Gb/s
Four 2/4/8Gbps Fibre Channel ports
Two USB2 ports Two 1Gbps
Ethernet ports
Two 6Gbps SAS ports (connec.ons to expansions)
Top node canister
Redundant Power Supply Unit (PSU) Note: also Power Cooling Module (PCM)
& BaTery
Op=onal Two 10Gbps Ethernet ports
Bobom node canister Note: iden.cal to the top node
canister, but installed upside down
© 2012 IBM Corpora.on Storwize V7000 Unified Storage Module
26
§ Up to 9 expansion enclosures may be aTached to the control enclosure – An expansion enclosure is configured with two
SBOD canisters (Switched Bunch Of Drives) – Each SBOD canister contains the following
components: ● 36-‐port SAS expander to aTach the internal drives
and provide an enclosure management processor
● Two 4x6Gbps mini-‐SAS connectors for chaining enclosures
● Both SBOD canisters communicate via internal I2C busses in the enclosure mid-‐plane
§ The storage module could be clustered via a redundant SAN fabric to another 3 control enclosures – Each control enclosures could be aTached to up
to 9 expansion enclosures
§ Up to 480 3.5” drives, 960 SFF drives or a mixture of both behind a Storwize V7000 Storage Module
241
System Storage
241
System Storage
System Storage
85
41
129
System Storage
85
41
129
241
System Storage
241
System Storage
241
System Storage
241
System Storage
System Storage
85
41
129
241
System Storage
© 2012 IBM Corpora.on Array’s Considera=ons with Storwize V7000 Unified
§ When using 8+P (RAID5), or 8+P+Q (RAID6) with Storwize V7000 Unified – The GPFS file system could use a block size of 256KiB (default), 1MiB or 4MiB when
accessing its file volumes (NSD) on Storwize V7000 file modules
– An Array on the internal drives (Hard Disk Drives) of Storwize V7000 storage module would have a default stripe unit size of 256KiB at an array level, or an op.onal stripe unit size of 128KiB (when using CLI)
27
RAID Topology
RAID Type
Stripe Unit
Stripe Width
Stripe Size
8+P 5 256KiB 8 2MiB 128KiB 8 1MiB
8+P+Q 6 256KiB 8 2MiB 128KiB 8 1MiB
© 2012 IBM Corpora.on
CABLING
28
© 2012 IBM Corpora.on Internal Cabling of Storwize V7000 Unified Between File Modules & with the Storage Module
§ A pair of direct Ethernet connec.ons (1Gbps) between each File Modules – Clustering connec.vity
§ Each File module has a direct FC (8Gbps) connec.on to a port per node canister in the Storage Module – 32Gbps of bandwidth between File and Storage Modules
§ 2 FC ports (8Gbps) per node canister in the Storage Module can be used for external FC connec.on – Host/Server connec.vity for na.ve block access using FC protocol (target SCSI port) – Back-‐End virtualised external storage (ini.ator port) – Remote Replica.on of Volumes (LUNs) with another Storwize V7000 Storage Module
29
File Module 1 File Module 2
Storage Module
PCI
1
2
PCI
3
4
AC
DC
AC
DC
10Gb/s
CAUTION
31
42
Disconnect allsupply power forcomplete isolation
Disconnect allsupply power forcomplete isolation
42
31
CAUTION
31
42
42
31
CAUTION
Disconnect allsupply power forcomplete isolation
CAUTION
Disconnect allsupply power forcomplete isolation
231
4
21
1 2
2 1
13
2412
2 14 3 2 14 3
21 4321 43
12
1 2
LNK
Tx/Rx
10Gb/s
LNK
Tx/Rx
10Gb/s
AC
DC
AC
DC
AC
DC
PCI
1
2
PCI
3
4
AC
DC
ATTENTIONPower supply filler is
required for system coolingRemove only when
installing 2nd power supplyAC
DC
© 2012 IBM Corpora.on External Cabling of Storwize V7000 Unified
§ Up to 120Gbps of Front-‐End bandwidth – 44 Gbps for File Access protocols, NDMP, management & IP remote replica.on – 76Gbps for Block Access protocols & management
31
File Module 1 File Module 2 Storage Module
PCI
1
2
PCI
3
4
AC
DC
AC
DC10G
b/s
PCI
1
2
PCI
3
4
AC
DC
AC
DC
10Gb/s
CAUTION
31
42
Disconnect allsupply power forcomplete isolation
Disconnect allsupply power forcomplete isolation
42
31
CAUTION
31
42
42
31
CAUTION
Disconnect allsupply power forcomplete isolation
CAUTION
Disconnect allsupply power forcomplete isolation
231
4
21
1 2
2 1
13
2412
2 14 3 2 14 3
21 4321 43
12
1 2
LNK
Tx/Rx
10Gb/s
LNK
Tx/Rx
10Gb/s
External IP Local Area Network (1GbE & 10GbE)External IP Local Area Network (1GbE & 10GbE)
2x10GbE 2x10GbE2x1GbE2x1GbE 2x10GbE2x1GbE
2x10GbE2x1GbE
NFS, CIFS, HTTPS, FTP, SCPNDMP, Management & Remote Replication
44Gbps bandwidth
iSCSI & Management44Gbps bandwidth
4x8Gbps
FCP32Gbps bandwidth
External SAN
© 2012 IBM Corpora.on
SOFTWARE & FEATURES OVERVIEW
33
© 2012 IBM Corpora.on
Volume
MDisk Target
Storwize V7000
MDisk Source
Storwize V7000 Unified Features § Block Access Protocols
– FCP & iSCSI – Disk Storage Virtualisa.on Engine
● Expand or shrink Volumes on-‐line
● Thin-‐provisioned Volumes
● On-‐line Volume Migra.on ● EasyTier: Automa.c reloca.on of hot and cold extents
– Data protec.on & Security ● Point-‐In-‐Time Copy (FlashCopy/snapshot)
> Full , Par.al, Space Efficient, Incremental, Cascaded, Consistency Groups & Reverse
● Virtual Disk Mirroring
● Synchronous & Asynchronous Remote Replica.on ● FlashCopy Manager for Windows, VMware, Linux, AIX,
Solaris & HP-‐UX
§ VMware – vCenter Server management plug-‐in & VAAI support
– Storage Replica.on Adaptor for SRM 34
§ Centralized Management & Administra.on – GUI & CLI – Performance Monitoring – Centralized alert & event log – Event no.fica.ons via email, Syslog or SNMP
– Call home and remote service features – Authen.ca.on service for Single Sign-‐On & LDAP
§ Network File Serving – NFS v2/v3, CIFS, HTTP, FTP & SCP – Clustered parallel file system – Ac.ve Cloud Engine
● Policy driven placement, movement, migra.on & dele.on of files ● Parallel Scan Engine ● Storage .ering (Disk-‐to-‐Disk-‐to-‐Tape)
● Integrated HSM agent to migrate inac.ve files to tape or Dedup VTL ● WAN caching (SoD)
– Ac.ve Directory, or LDAP or NIS support ● Local Authen.ca.on Support
– Quotas Management – Data protec.on & Security
● Up to 256 snapshots per file system ● Asynchronous IP Remote replica.on for file access ● Integrated TSM 6.2 Backup/Archive client or NDMP ● “Scan on access” & “scan on demand” An.virus
Hot-‐spots Op=mized performance and throughput
Automa=c Reloca=on
SSDs HDDs SSDs HDDs
Volume
Volume copy 2
Storwize V7000
Volume copy 1
Up to 256
Tier 3
© 2012 IBM Corpora.on Unified Graphical User Interface
35
File Management Integrated into Naviga=on
Storage pools may be used for both block & file
workloads
File storage management completely integrated
© 2012 IBM Corpora.on Unified Graphical User Interface
36
© 2012 IBM Corpora.on Unified Graphical User Interface
37
© 2012 IBM Corpora.on Unified Graphical User Interface
38
© 2012 IBM Corpora.on
Storage Pools
ACE provides ILM & HSM tools to define file level policies that determine where the data is physically stored to match the cost of your storage resources to the value of your data regardless of its placement in the logical directory structure
§ File placement policies determine which storage pool files are ini.ally placed in § File placement rules are determined by aTributes known when a file is created such as file name,
user name, group name or the fileset § Once files exist in a file system, file management policies allow you to move, mirror or delete files § You can use file management policies to move data from one pool to another without changing the
files loca.on in the directory structure
Ac=ve Cloud Engine tools for ILM & HSM
§ A fileset is a logical subtree of the file system namespace and provides a way to par..on the namespace into smaller, more manageable units
§ Mul.ple levels of rules can be applied because the complete policy rule set is evaluated for each file when the policy engine executes
§ Storage pools allow you to group mul.ple physical storage devices within a file system (SSD, SAS, Fibre Channel, NL-‐SAS, SATA, etc.)
41
ACE
Tier 3
File System
Filesets