Photo/isometric drawing provided by manufacturer i-SIP Building System Description of Product This is an assessment of the Innovaré Systems Ltd Structural Insulated Panel System developed for wall and roofing. The assessment is for a typical four storey domestic property and external treatment should be dealt with separately. Key Factors Assessed Mechanical Resistance & Stability Safety in case of Fire Health, Hygiene and Environmental Safety in Use Protection against noise Energy Economy and heat retention Durability serviceability and identification Validity This certificate was first issued on 18 th September 2018 and is valid until 18 th September 2019 Issue Dated 18 th September 2018 Certificate No: EWW812

Upload: others

Post on 02-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: i-SIP Building System · BRE fire test report number 241998 & 241094 . Thermal Performance U -Value Matrix . RBA Acoustics Sound Insulation Test Report 3874/SIT2 . ATTMA Air Permeability

Photo/isometric drawing

provided by manufacturer

i-SIP Building System

Description of Product

This is an assessment of the Innovaré Systems

Ltd Structural Insulated Panel System

developed for wall and roofing. The

assessment is for a typical four storey domestic

property and external treatment should be

dealt with separately.

Key Factors Assessed

Mechanical Resistance & Stability

Safety in case of Fire

Health, Hygiene and Environmental

Safety in Use

Protection against noise

Energy Economy and heat retention

Durability serviceability and identification

Validity

This certificate was first issued on 18th September 2018 and is valid until 18th September 2019

Issue Dated 18th September 2018

Certificate No: EWW812

Page 2: i-SIP Building System · BRE fire test report number 241998 & 241094 . Thermal Performance U -Value Matrix . RBA Acoustics Sound Insulation Test Report 3874/SIT2 . ATTMA Air Permeability

The structurally insulated panels (SIPs) comprise OSB/3, EPS insulation and structural timber to form loadbearing walls and

roofs in buildings.

The panels have been verified as suitable as load bearing partitions and external walls for a typical four storey domestic

property with a tiled duo-pitched roof and suitable wall cladding.

The system can also be used in residential, commercial and institutional buildings both in loadbearing applications and as a

non-loadbearing infill panel to a structural frame subject to the submission and verification of additional structural

calculations on an individual project basis.

i-SIPs are available in the following thicknesses: 111, 136, 162, 206 and 257mm.

Maximum standard panel dimensions: 6.00 x 2.77 m.

Design loadings have been taken to cover the building being located in any part of England or Wales with a maximum altitude of 100m and basic wind velocity of 25m/s.

Roof construction consists of factory produced cassettes consisting of Engineered timber joists receiving particle board or

plywood sheathing.

Suspended floors consist of factory produced cassettes consisting of Engineered timber joists receiving particle board or

plywood boarding.

Wall construction consists of panels which have been checked with intermediate restraint (from an intermediate floor

construction).

Excluded from the check are the following items which should all be designed on a project specific basis:

• Drifted snow analysis

• Pitched roofs

• Ridge beams

• Purlins

• Eaves beams

• Flat roof cassettes

• Suspended floor cassettes

• Steelwork

• Lintels

• Balconies

• Staircases

• Foundations

• Overall resistance to uplift/overturning and the racking resistance of the structure

Page 3: i-SIP Building System · BRE fire test report number 241998 & 241094 . Thermal Performance U -Value Matrix . RBA Acoustics Sound Insulation Test Report 3874/SIT2 . ATTMA Air Permeability

 

  

The Innovaré Systems Limited i-SIP Structural Insulated Panel System relies on other construction products, materials and

components to form a complete wall, floor and roof element.

Structural design of the building /element incorporating the SIP shall be in accordance with the relevant Eurocode.

Details of additional protection measures to resist moisture/contaminants from the ground and from moisture outside the

building are site specific: to be determined by location, subsoil and exposure conditions.

The installation must be undertaken by competent installers trained, registered and monitored by Innovaré Systems Limited

and in strict accordance with their designs, details and specifications.

The thermal insulation performance of this system should be considered in context of the contribution made to the overall

performance of the wall structure.

Appropriate thermal analysis will be provided in each instance to demonstrate continued compliance with Approved

Document L 2013.

The following items should be designed on a project specific basis:

Ridge beams

Purlins

Eaves beams

Steelwork

Foundations

Overall racking resistance of the structure

First floor structure

Notification that the structures have been completed and signed off by the manufacturer and are in accordance with the

individual design.

For LABC Warranty purposes:

1) The product is to be used and installed in strict accordance with the BBA certification.

2) The external cavity must be drained and ventilated, and the width must be in accordance with Chapter 7 of LABC

Warranty’s Technical Manual.

3) The SIP panels must be protected by a breather membrane within the cavity,

4) The system must be installed by trained operatives and to a height not exceeding 4 stories including a room in roof.

Page 4: i-SIP Building System · BRE fire test report number 241998 & 241094 . Thermal Performance U -Value Matrix . RBA Acoustics Sound Insulation Test Report 3874/SIT2 . ATTMA Air Permeability

LABC consider that, the i-SIP Building System will meet the functional requirements of the Building

Regulations (listed below) if the criteria detailed in this certificate are met;

The Building Regulations 2010 (as amended) England & Wales

Regulation 7 Materials and workmanship

Note: The system is acceptable.

AD A Structure

Note: Subject to limitations detailed in Conditions section.

AD B Fire Safety

Note: Subject to limitations detailed in Conditions section.

AD L1 Conservation of fuel and power

Note: The thermal insulation performance of this system should be considered in the

context of the contribution made to the overall performance of the building.

The Building Regulations 2010 (as amended) England

AD B Fire Safety

Note: Subject to limitations detailed in Conditions section.

AD L1 Conservation of fuel and power

Note: The thermal insulation performance of this system should be considered in the

context of the contribution made to the overall performance of the building.

The Building Regulations 2010 (as amended) Wales

AD B Fire Safety

Note: Subject to limitations detailed in Conditions section.

AD L1 Conservation of fuel and power

Note: The thermal insulation performance of this system should be considered in the

context of the contribution made to the overall performance of the building.

The Building (Scotland) Regulations 2004 (as amended)

If you would like to discuss a specific use of the product in Scotland it will require an additional

assessment under the Scottish Building Regulations and accordingly you should contact the LABSS

STAS Administrator at www.labss.org

Page 5: i-SIP Building System · BRE fire test report number 241998 & 241094 . Thermal Performance U -Value Matrix . RBA Acoustics Sound Insulation Test Report 3874/SIT2 . ATTMA Air Permeability

LABC Warranty

LABC Warranty conditionally accepts the use of i-SIP Building System, when installed and used in

accordance with the Scope and Conditions of this Certificate. Visit www.labcwarranty.co.uk for our

LABC Warranty Technical Manual requirements and Warranty conditions of acceptance.

ISO 9001:2015 Management Certificate

BBA Certificate 08/SO40

BRE fire test report number 241998 & 241094

Thermal Performance U-Value Matrix

RBA Acoustics Sound Insulation Test Report 3874/SIT2

ATTMA Air Permeability Test Certificate 10139206R

DBM Consultants Design Calculations no. 8179