Enter culvert geometry and hydraulic data for up to 5 culverts on the "Culvert Data" sheet (and "User Shape" sheets if necessary). Enter up to 10 boundary condition scenarios to be analysed.
Click the "XS Plot" button to verify accuracy of input geometry data. Click the "XS Properties" button to view a table of culvert properties including area, wetted perimeter, and hydraulic radius.
Click the "Calculate" button to generate flow profiles through each of the selected pipes for each of the specified boundary condition scenarios. If input errors are detected, the "Errors" sheet will appear, with information on the errors. Otherwise, results will appear in the "Summary", "Profiles" and "Profile Plot" sheets. The profile shown on the "Profile Plot" sheet can be selected by pressing the "Plot Profile" button on the "Profiles" sheet. Clicking on the "Culvert Data" sheet tab will hide the output sheets and enable a new analysis.
Project Test Project 2
Culvert Data
Pipe No. 1 2 3 4Include (Y/N) Y Y N NStation (m) 100 110 120 130U/S Invert El (m) 100.100 101.700 100.300 100.300D/S Invert El (m) 100.000 101.600 100.000 100.000Length (m) 32.00 32.00 30.00 30.00Roughness n 0.025 0.025 0.028 0.028Ent. Loss Coeff. 0.7 0.7 0.5 0.5Exit Loss Coeff. 1 1 0.5 0.5Shape R R R RRise (m) 1.50 0.90 2.50 2.50Span (m) 2.50 2.50