Page 1: HUM CO - gridserver.comhumcomarine.com.s167923.gridserver.com/wp-content/uploads/07E… · corrosion. Unfortunately, their sheer bulk reduced a ship’s capacity and increased its

1074 Kenran Industrial Dr.St. Louis, MO 63137Phone: 1-800-381-9968

Fernstrum Gridcooler

HUMCOEngine Room

590

7

Page 2: HUM CO - gridserver.comhumcomarine.com.s167923.gridserver.com/wp-content/uploads/07E… · corrosion. Unfortunately, their sheer bulk reduced a ship’s capacity and increased its

1074 Kenran Industrial Dr.St. Louis, MO 63137Phone: 1-800-381-9968

Fernstrum Gridcooler

HUMCOEngine Room

Keel cooling first appeared inthe early 1800s when a coppertube was hung over the side of aboat to condense steam. This laterevolved into pieces of channelwelded onto the hull. These channelcooling systems offered importantadvantages over raw water cooling.They eliminated silt and sandbuildup in engine jackets andprotected engines against salt watercorrosion. Unfortunately, their sheerbulk reduced a ship’s capacity andincreased its drag. They were alsoprone to external fouling. Today, keelcoolers are closed circuit coolingunits mounted to a vessel’s hullbeneath the waterline. This closedcooling system eliminated the needfor an inboard heat exchanger, rawwater pumps and strainers as well ashigh maintenance.

Engine jacket water is piped directly to the FERNSTRUMGRIDCOOLER keel cooler, which cools the water andthen sends it back to the engine. The GRIDCOOLERkeel cooler is in constant contact with the sea water fortransfer of heat.

Keel cooler mounted below the water line.

Our GRIDCOOLER® keel coolers are the smallest, most efficient keelcoolers available. The rectangular tube design is more efficient anddurable than grooved round tubing.

Our 100% parts inspection process and rigorous testing proceduresinsure that all GRIDCOOLER keel coolers are built with the sameexacting standards.

Decades long service life and our high customer satisfaction haveproven our coolers’ durability for over 60 years.

With a vast array of standard options and custom configurationsavailable, we can recommend a cooling system that meets the uniqueneeds of your engine on your vessel in your operating environment.

With decades of experience in the marine engine cooling market, oursales and engineering staff can give you advice on cooler placement,installation and service. Should you require an emergency replacementunit, we can have it shipped to you within three business days or less.

\ Ship Hull\ 591

7

Page 3: HUM CO - gridserver.comhumcomarine.com.s167923.gridserver.com/wp-content/uploads/07E… · corrosion. Unfortunately, their sheer bulk reduced a ship’s capacity and increased its

1074 Kenran Industrial Dr.St. Louis, MO 63137Phone: 1-800-381-9968

Fernstrum Gridcooler

HUMCOEngine Room

STACKED GRIDCOOLER keel coolers produce twicethe amount of cooling with less space required.

To ensure that you get precisely what you need, webegin by asking a lot of questions. We’ll need toknow your engine make and model number,power rating, heat rejection, freshwaterflow rate, and the temperaturerequirements of the water entering andleaving the cooler. If you don’t have allthis information, we’ll get it for you - we maintain current files onall major marine engine manufacturers. We’ll also need your vessel’shull design, it’s minimum speed at full rated power, and the maximum water temperature in which it willoperate. With this data, we can determine exactly what size GRIDCOOLER® keel coolers your vessel will need- under it’s most severe operating conditions.

E-OPTION GRIDCOOLER keel coolers have zinc anodesmounted at the ends of the units. This modification is availableupon request at no additional charge and works well for fishingvessels where entanglement of nets is a concern.

592

7

Page 4: HUM CO - gridserver.comhumcomarine.com.s167923.gridserver.com/wp-content/uploads/07E… · corrosion. Unfortunately, their sheer bulk reduced a ship’s capacity and increased its

1074 Kenran Industrial Dr.St. Louis, MO 63137Phone: 1-800-381-9968

Fernstrum Gridcooler

HUMCOEngine Room

L-OPTION GRIDCOOLER keel coolers withextended support plates reduce the number ofhull penetrations needed for installation.

Z-OPTION GRIDCOOLER keel coolers havelower profile flange connections with allmounting hardware and mating flangesincluded. L-Option support plates are includedas standard in this configuration.This design eases installation ondouble hulled vessels and mayeliminate the need for cofferdams.

593

7

Page 5: HUM CO - gridserver.comhumcomarine.com.s167923.gridserver.com/wp-content/uploads/07E… · corrosion. Unfortunately, their sheer bulk reduced a ship’s capacity and increased its

1074 Kenran Industrial Dr.St. Louis, MO 63137Phone: 1-800-381-9968

Fernstrum Gridcooler

HUMCOEngine Room

Amusement Park RidesATBBargesBridge Erection BoatsBuoysCasino Boats

Air Conditioning UnitsBowthrustersElectronics

Commercial FishingCrab BoatsDredgesFerriesLanding CraftLife Boats

Oil Spill Recovery BoatsOSVPatrol BoatsPilot BoatsPSVPump Stations

GearsGenerator Sets

Hydraulic SystemsPropulsion Engines

Push BoatsRecreational BoatsFishing BoatsShrimp BoatsSubmarinesTug Boats

PumpsWinches

keel cooler is a unique heat exchanger thatcomes as a completely assembled unit, silver wire brazed and factory tested to assure dependability. It is not a kitthat requires additional assembly before installation. The rectangular shaped tubing used in its construction isstructurally strong and has a higher heat transfer rate than round tubing. The GRIDCOOLER keel cooler is a durable,compact unit designed to meet the engine manufacturer’s cooling requirements and your operating conditions.

Washington Island Ferry Line, Washington Island in Door County, WI has been using Fernstrum GRIDCOOLER keel coolers on theirvessels for over 30 years. They’ve held up year round through extensive winter service in Lake Michigan ice as well as may hours ofsummer operation and are still providing excellent daily service without incident.

When the Washington Island Ferry Line built their new ice breaking ferry boat, the Arni J. Richter,Fernstrum’s quality, durability and excellent service made them the obvious choice.

“When you consider what a substandard keel cooler can cost in lost time and dollars, and maybea dry docking, installing a Fernstrum GRIDCOOLER keel cooler is an easy decision.”

Dick Purinton,President/General ManagerWashington Island Ferry Line - Washington Island, Wisconsin

Hermasa have been using the Fernstrum Gridcoolers very successfully for over 10 years in their tugboats.

Alexandre Maciel,HERMASA

South America