Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · offi[email protected] · www.commendusa.com www.commend.com Datasheet Version 1.1/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice. P 1 | 3 DATASHEET This module enables the management of remote inputs and outputs in complex systems far from the central. Data is transmitted fully digital via 2-wire lines to the central. Managing of 8 inputs with 5 steps and 8 outputs, thereof 4 make- and 4 change-over contacts. Status-LEDs for all inputs and outputs show the function at a glance, additionally the line from the ET 8E8A to the central is continuously monitored. Mounting is possible in a 19“ rack on a DIN rail or with the supplied mounting rail for wall mounting. ET 8E8A Remote input- / output unit with 8 inputs (5 steps) and 8 outputs (4 make and 4 change over contacts). 1. Remote Input-/Output Unit ET 8E8A ET 8E8A 1

Upload: jeff-hobbs

Post on 23-Feb-2016

213 views

Category:

Documents


0 download

DESCRIPTION

http://www.sourceav.com/Files/Commend/Data_Sheets_Inputs_and_Outputs/DS-ET8E8A-CU-EN-V11-1207.pdf

TRANSCRIPT

Page 1: Document

Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · [email protected] · www.commendusa.com

www.commend.comDatasheet Version 1.1/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice. P 1 | 3

DATASHEET

This module enables the management of remote inputs and outputs in complex systems far from the central. Data is transmitted fully digital via 2-wire lines to the central. Managing of 8 inputs with 5 steps and 8 outputs, thereof 4 make- and 4 change-over contacts. Status-LEDs

for all inputs and outputs show the function at a glance, additionally the line from the ET 8E8A to the central is continuously monitored. Mounting is possible in a 19“ rack on a DIN rail or with the supplied mounting rail for wall mounting.

ET 8E8A

Remote input- / output unit with 8 inputs (5 steps) and 8 outputs (4 make and 4 change over contacts).

1.

Remote Input-/Output Unit ET 8E8A

ET 8E8A

1

Page 2: Document

ET 8E8A

Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · [email protected] · www.commendusa.com

www.commend.comDatasheet Version 1.1/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice. P 2 | 3

DATASHEET

Technical Data – Benefi ts

TECHNICAL DATA

Inputs: 8 inputs for fl oating contacts

Outputs: 8 relay outputs 30 V/3 A

Status indication: Status-LEDs for all inputs and outputs

Operating temperature range: –20° C bis +60° C (-4° F to 140° F)

Storage temperature range: –20° C to +60° C (-4° F to 140° F)

Relative humidity: up to 95 %

Plug: plugable screw terminals

Cabling: star feed, 2-wire, twisted

Power supply: from central option: external, fl oating supply for greater line length (8–24 VAC or 10–35 VDC, 500 mA)

Measurements: 105 x 105 x 62 mm (4.14 x 4.14 x 2.44 inch) (incl. mounting rail)

Weight incl. package: 350 g (0.8 lbs)

LINE LENGTHET8E8A – SUBSCRIBER CARD

Cable type:AWG:

ø 0.5 mm24

ø 0.6 mm22

ø 0.8 mm20

F-YAY (Instal lation cable PVC, 100 nF/km,30.5 nF/1,000 ft)

750 m (2,460 ft)

1,000 m (3,281 ft))

2,000 m (6,562 ft)

F-YAY with external Supply

2,000 m (6,562 ft)

2,000 m (6,562 ft)

2,000 m (6,562 ft)

J-02YS(St)Y (Cat. 5 ca-ble, foamed polyethyle-ne, 45 nF/km,13.7 nF/1,000 ft)

750 m (2,460ft) (1,000 m / 3,281 ft with max. 4 relays),

1,000 m (3,281 ft)

2,000 m (6,562 ft)

J-02YS(St)Y with external Supply

3,000 m (9,843 ft)

3,000 m (9,843 ft)

3,000 m (9,843 ft)

SYSTEM REQUIREMENTS

GE 200 with G2-GED-4 or GE 700 with G7-GED-4

Central software min. Pro 05.0

EXTENT OF SUPPLY

1 Input-/Output unit including:

Mounting rail, screws and dowels for wall mounting

Short reference

BENEFITS

Ideal for remote inputs and outputs

Star feed cabling via 2-wires to central

Fully digital transmission of data to the central

Can be connected to every 2-wire subscriber

8 inputs with 5 steps

8 outputs with 4 make contacts and 4 change-over contacts

Screw terminals for use with cables up to 1.5 mm² (16 AWG)

Status–LEDs for all outputs

Status–LEDs for all inputs

Rack mounting on DIN rail

Wall mounting with included mounting rail

Line fault monitoring from ET 8E8A to central

Page 3: Document

ET 8E8A

Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · [email protected] · www.commendusa.com

www.commend.comDatasheet Version 1.1/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice. P 3 | 3

DATASHEET

Installation

PRECAUTIONS

ESD precautions must be observed.

The station may only be installed by authorised service engineers.

MOUNTING INSTRUCTIONS

Do not expose the station to extreme temperature (under –20° C/-4° F or above +60° C/140° F).

Each card G2-GED-4 or G7-GED-4 can handle one ET 8E8A, that corresponds to 8 x ET 8E8A in a GE 200 or 12 x ET 8E8A in a GE 700.

MEASUREMENTS

Bottom view with mounting rail for wall mounting.Measuring units: mm (inch), not scale!

CONNECTION DIAGRAM

BAP

WR

2P

WR

1

IN8

S 1

S 2

S 3

S 4

S 8

S 7

S 6

S 5

IN7

IN6

IN5

IN4

IN3

IN2

IN1

GND

GND

GND

GND

GND

GND

GND

GND

AB

Optional: external, floatingsupply for greater line lengthPlug in transformer8-24 V AC or 10-35 V DC (500 mA)

Subscribercentral

Inputs 1 to 8

Outputs 1 to 8e.g.: door opener

power supply

86 (

3.39

)

35 (

1.38

)

105

(4.1

4)

105 (4.14)

98 (3.86)

18 (0.71) 18 (0.71) 18 (0.71) 18 (0.71)(0.28)

7(0.28)

7(0.28)

7