Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · [email protected] · www.commendusa.com
www.commend.comDatasheet Version 1.1/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice. P 1 | 3
DATASHEET
This module enables the management of remote inputs and outputs in complex systems far from the central. Data is transmitted fully digital via 2-wire lines to the central. Managing of 8 inputs with 5 steps and 8 outputs, thereof 4 make- and 4 change-over contacts. Status-LEDs
for all inputs and outputs show the function at a glance, additionally the line from the ET 8E8A to the central is continuously monitored. Mounting is possible in a 19“ rack on a DIN rail or with the supplied mounting rail for wall mounting.
ET 8E8A
Remote input- / output unit with 8 inputs (5 steps) and 8 outputs (4 make and 4 change over contacts).
1.
Remote Input-/Output Unit ET 8E8A
ET 8E8A
1
![Page 2: Document](https://reader036.vdocuments.us/reader036/viewer/2022081822/568bd5eb1a28ab20349a3847/html5/thumbnails/2.jpg)
ET 8E8A
Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · [email protected] · www.commendusa.com
www.commend.comDatasheet Version 1.1/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice. P 2 | 3
DATASHEET
Technical Data – Benefi ts
TECHNICAL DATA
Inputs: 8 inputs for fl oating contacts
Outputs: 8 relay outputs 30 V/3 A
Status indication: Status-LEDs for all inputs and outputs
Operating temperature range: –20° C bis +60° C (-4° F to 140° F)
Storage temperature range: –20° C to +60° C (-4° F to 140° F)
Relative humidity: up to 95 %
Plug: plugable screw terminals
Cabling: star feed, 2-wire, twisted
Power supply: from central option: external, fl oating supply for greater line length (8–24 VAC or 10–35 VDC, 500 mA)
Measurements: 105 x 105 x 62 mm (4.14 x 4.14 x 2.44 inch) (incl. mounting rail)
Weight incl. package: 350 g (0.8 lbs)
LINE LENGTHET8E8A – SUBSCRIBER CARD
Cable type:AWG:
ø 0.5 mm24
ø 0.6 mm22
ø 0.8 mm20
F-YAY (Instal lation cable PVC, 100 nF/km,30.5 nF/1,000 ft)
750 m (2,460 ft)
1,000 m (3,281 ft))
2,000 m (6,562 ft)
F-YAY with external Supply
2,000 m (6,562 ft)
2,000 m (6,562 ft)
2,000 m (6,562 ft)
J-02YS(St)Y (Cat. 5 ca-ble, foamed polyethyle-ne, 45 nF/km,13.7 nF/1,000 ft)
750 m (2,460ft) (1,000 m / 3,281 ft with max. 4 relays),
1,000 m (3,281 ft)
2,000 m (6,562 ft)
J-02YS(St)Y with external Supply
3,000 m (9,843 ft)
3,000 m (9,843 ft)
3,000 m (9,843 ft)
SYSTEM REQUIREMENTS
GE 200 with G2-GED-4 or GE 700 with G7-GED-4
Central software min. Pro 05.0
•
•
EXTENT OF SUPPLY
1 Input-/Output unit including:
Mounting rail, screws and dowels for wall mounting
Short reference
•
•
BENEFITS
Ideal for remote inputs and outputs
Star feed cabling via 2-wires to central
Fully digital transmission of data to the central
Can be connected to every 2-wire subscriber
8 inputs with 5 steps
8 outputs with 4 make contacts and 4 change-over contacts
Screw terminals for use with cables up to 1.5 mm² (16 AWG)
Status–LEDs for all outputs
Status–LEDs for all inputs
Rack mounting on DIN rail
Wall mounting with included mounting rail
Line fault monitoring from ET 8E8A to central
•
•
•
•
•
•
•
•
•
•
•
•
![Page 3: Document](https://reader036.vdocuments.us/reader036/viewer/2022081822/568bd5eb1a28ab20349a3847/html5/thumbnails/3.jpg)
ET 8E8A
Commend, Inc. · 63 Ramapo Valley Road, Suite 201 · Mahwah, New Jersey 07430 · Tel. (201) 529-2425 · Fax (201) 529-0008 · [email protected] · www.commendusa.com
www.commend.comDatasheet Version 1.1/1207 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice. P 3 | 3
DATASHEET
Installation
PRECAUTIONS
ESD precautions must be observed.
The station may only be installed by authorised service engineers.
•
•
MOUNTING INSTRUCTIONS
Do not expose the station to extreme temperature (under –20° C/-4° F or above +60° C/140° F).
Each card G2-GED-4 or G7-GED-4 can handle one ET 8E8A, that corresponds to 8 x ET 8E8A in a GE 200 or 12 x ET 8E8A in a GE 700.
•
•
MEASUREMENTS
Bottom view with mounting rail for wall mounting.Measuring units: mm (inch), not scale!
CONNECTION DIAGRAM
BAP
WR
2P
WR
1
IN8
S 1
S 2
S 3
S 4
S 8
S 7
S 6
S 5
IN7
IN6
IN5
IN4
IN3
IN2
IN1
GND
GND
GND
GND
GND
GND
GND
GND
AB
Optional: external, floatingsupply for greater line lengthPlug in transformer8-24 V AC or 10-35 V DC (500 mA)
Subscribercentral
Inputs 1 to 8
Outputs 1 to 8e.g.: door opener
power supply
86 (
3.39
)
35 (
1.38
)
105
(4.1
4)
105 (4.14)
98 (3.86)
18 (0.71) 18 (0.71) 18 (0.71) 18 (0.71)(0.28)
7(0.28)
7(0.28)
7