hks - m-da-h-f4 · 2016. 4. 7. · performance specification for determining sizes and hazard...
TRANSCRIPT
M-DA-H-F4
Dreh-Antriebe
Rotary actuators
HKS Unternehmensgruppe
Leipziger Straße 53-55D-63607 Wächtersbach-Aufenau
Phone: +49 (0)6053 / 6163 - 0Extension Sales: -29Telefax: +49 (0)6053 / 6163 - 39
E-Mail: [email protected]: www.hks-partner.com
Copyright © 2006 by HKS
Advantages- high collection performance by max. availibility of rotary actuator- compact and ergonomical design of rotary actuator- very long lifetime- almost maintenance free
- emptying process with reduced dust and noise emissions and low stress container handling- splined shaft ends for max torque transmission- safety features conforming to EU standards- foot mounting for smallest clearance- working pressure up to 3000 PSI- torques up to 440,000 IN-LBS- usable for all lifting devices- all rotation angles possible- steep emtying angle
HKS rotary actuatorsSIMPLE - ROBUST - DEPENDABLE
Lastenheft zur Größenbestimmung und Gefahrenanalyse
3
PLZ, OrtCity, ZIP-code
StraßeStreet
TelefonTelephone
TelefaxTelefax
Technische DatenTechnical data
FirmaCompany
Datum / UnterschriftDate /Signature
2. Schwenkwinkel effektiv in GradEffective angle of rotation in deg.
2.1 Gesamt-Schwenkwinkel in GradTotal angle of rotation in deg.
3 Einbaulage horizontalHorizontal installation
3.1 Einbaulage vertikalVertical installation
4 Schwenkzeit T Sek.Rotation time Sec.
4.1 Taktfolge Z / MinuteNo. of Cycles / minute
4.2 Arbeitsstunden pro Tag StdWorking hours/day h
1.1 Hebelarm r mLeverage in
1.2 Gewicht G kgWeight lb
1.3 Axiallast Ga kgAxial load lb
1.4 Radiallast Gr kgRadial load lb
1.6 Drehmoment Vorgabe NmSpecification of torque in-lb
5 HydraulikanlageHydraulic system
5.1 Effektiver Arbeitsdruck p1 barEffective working pressure psi
5.2 Max. zul. Systemdruck p2 barMax. permitted system pressure psi
5.3 Förderstrom Q l /MinuteDelivery rate gpm
5.4 Anlagentemperatur C1 °CelsiusSystem temperature °F
5.5 Umgebungstemperatur C2 °CelsiusSurrounding temperature °F
5.6 BetriebsmediumMedium used
7 Bedingungen am EinsatzortConditions at working place
SonstigesOthers
Empfohlener AntriebRecommended actuator
oder Biegemoment Nmor bending moment in-lb
LasthalteventilLoad-holding vale
Performance specification for determining sizes and hazardanalysis
KundeCustomer HKS
Fax: +49 (0) 6053 6163-39
Email: [email protected]
*Nur gültig mit Unterschrift und Datum*Only valid with signature and date
16,650 INCH-LBS 1,180 Nm Oil ports in the feet
4
18,000 INCH-LBS 2,000 Nm through holes in the feet
5
19,500 INCH-LBS 2,225 Nm
6
19,300 INCH-LBS 2,180 Nm
7
23,000 INCH-LBS 2,625 Nm
8
26,000 INCH-LBS 2,950 Nm
9
42,000 INCH-LBS 4,800 Nm
10
55,700 INCH-LBS 6,300 Nm with cushioning in both end positions
11
63,000 INCH-LBS 7,100 Nm
12
13
80,000 INCH-LBS9,000 Nm
165,000 INCH-LBS 18,700 Nm
14