high voltage, inc. products presentation short version
TRANSCRIPT
Cable FaultLocatorsw/TDR
Oil/Fluid Dielectric
Testers
Very Low Frequency AC VLF E Series & VLF Series
W/TD & PD Diagnostics
Portable AC HipotsHigher kVA AC Test
Sets
DC Hipots & Megohmmeters
HV Divider
Aerial Lift Testers
HVI Products Are Designed to Surpass All Othersin Features, Specifications, and Ease in Use
HVI - The World’s Source ForHigh Voltage Test Equipment
2
PFT Series Portable AC HipotsImproved Design Making AC Testing Easier
Models AvailablePFT-103CM 0-10 kV @ 3 kVA
PFT-301CM 0-30 kV @ 1 kVA
PFT-303CM 0-30 kV @ 3 kVA
PFT-503CM 0-50 kV @ 3 kVA
PFT-1003CM 0-100 kV @ 3 kVA
Higher kVA testers available:
HPA Series AC Dielectric Test Sets
FPA Series Field Portable AC Test Sets
PFT-301CM
30 kVac @ 1 kVAPFT-1003CM
100 kVac3 kVA
HPA-507.5FC1
0-50 kVac @ 7.5 kVACorona < 10pc
HPA-30020FC3
0-300 kVac @ 20 kVA
The HPA Series AC test sets are designed for AC testing applications requiring higher power than offered by our portable PFT Series. Models from 5 kVac - 300 kVac from 5 kVA – 40 kVA are available and in many control configurations.
3
HPA Series - AC Dielectric Test Sets
5 kVA – 40 kVA w/Multiple Control Options
High voltage tanks are also available for the OEM.
FPA-12/066F0 – 6 kVac @ 1 amp
0 – 12 kVac @ .5 ampFault Burn Mode
Isolated Return GuardShielded Output Cable
4
FPA Series Field Portable AC Testers
Designed for field testing higher capacitance
loads: Motors & Generators Rubber Goods Switchgear Bus Ducts Bushings
Next Model to Look For
FPA-30/1515F0 – 15 kVac @ 1 amp
0 – 30 kVac @ 0.5 amp
Other high kVA AC Test Sets for field use can be found in the HPA Series and the ALT Series
5
ALT Series - Aerial Lift Testers
ALT-120/60 (F)Most powerful, full featured boom and liner tester on the market. No tester offers more power, longer duty cycle, better packaging, and more features.
Output: 0 - 60/120 kVac @ 7 kVA
Duty Rating: 7 kVA @ 1 hour, 4 kVA continuous
• Internal inductive compensation• Internal voltmeter divider• Detachable interconnect cable• Smaller size – lower weight
Also popular for AC testing isolated phase bus and other high capacitance loads
6
PTS Series– DC Hipots
Models AvailablePTS-20 0-20 kV @ 10 mAPTS-37.5 0-37.5 kV @ 10 mAPTS-75 0-75 kV @ 10 mAPTS-80 0-80 kV @ 10 mAPTS-100 0-100 kV @ 10 mAPTS-130 0-130 kV @ 10 mA PTS-200 0-200 kV @ 5 mAPTS-300 0-300 kV @ 5 mAPTS-600 0-600 kV @ 5 mA
PTS-80 PTS-100
Top model for DC bucket truck testing
Smaller & Lighter – Rugged & Reliable – More Full FeaturedTwo Instruments In One: Hipot & HV Megohmmeter
7
DTS Series - Oil Dielectric Testers
Portable - Well Built - Rugged Design
Oil Test CupsASTM D877 ASTM 1816
IEC 156
DTS-60D0 – 60 kVac @ 800 VA
500/2000/3000 V/sec. rate of rise
DTS-100D0 – 100 kVac @ 800 VA
500/2000/3000 V/sec. rate of rise
8
DTS-60A
0 – 60 kVac @ 800 VA
Fully programmable and automatic in
operation, including built-in printer.
DTS Series - Oil Dielectric TestersAutomatic/Programmable Model
9
CDS Series - Cable Fault FindersSurge Generators/Thumpers
Models AvailableCDS-2010U 0-5/10/20 kV output taps
1000 joules, 400 mA burn current
CDS-3616U 0-9/18/36 kV output taps1600 joules, 280 mA burn current
CDS-3632U 0-9/18/36 kV output taps3200 joules, 280 mA burn current
Custom 100 kV units available
CDS-2010UCan discharge 1000 joules at just 5 kV. Find your fault without making more.
Full featured design offers: Three output voltage taps Fully variable hipot output Higher burn current TDR/radar ready
30 kVac
44 kVac62 kVac
90 kVac
50, 65, & 120 kVac
200 kVac
VLF Series Original Oil Design
VLF WithstandVLF Tan Delta
VLF Partial Discharge
Mature, well established, durable product line
CE Marked
The most models available with the highest voltage
and power ratings.
Smallest VLF
11
VLF E Series - Solid State DesignFully Automatic, Programmable, Complete
Data Logging & Reporting, & Wireless
Test Modes• VLF Test• DC Test• Sheath Test• Fault Burn
Tan Delta Option for Cable Diagnostic Testing
Model: VLF-34E0 – 34 kVac peak Sinusoidal
0.1 Hz – 0.01 Hz, .5 uF – 5 uFWireless Control via XBee
12
VLF Cable TestingWithstand - Tan Delta - Partial Discharge
VLF Withstand: VLF used alone to apply over voltage for a simple proof/stress test to verify cable integrity. Cause defects to fail during test and make the repair or replacement, avoiding in-service failures.
VLF Tan Delta: VLF applies slight over voltage to cable while TD measurement system evaluates extent of overall insulation and accessory deterioration. Helps to prioritize cable replacement and/or injection.
VLF Partial Discharge: VLF applies slight over voltage to cable while PD detection instruments indicate locations and severity of electrical noise.
Use one, two, or all three to learn what you need about your cable to make an educated decision as to corrective action or expected cable life.
Tangent Delta & Partial DischargeDiagnostic Cable Testing with VLF
TD & PD Cable Measurement SystemProduced by Power Diagnostix – Germany
TD & PD70 kVac peak Models to 200 kV
TD E Series - Tan δProvided by High Voltage, Inc.
TD-34E 0 – 34 kV TD-65E
0 – 65 kV
Cable Testing PackagesVLF - Tan Delta - Partial Discharge - Fault Locating
VLF-200CM mobile package w/TD & PD
VLF-200CM with 20kw generator
From 15 kV industrial/commercial, to 35 kV wind farm, to 200 kV utility transmission applications, HVI can supply and package the appropriate VLF, TD, and PD test equipment, as well as cable fault locators w/TDR, listening devices, cable reels, etc.
VLF & Thumper Package Economical & Easy Test Van
15
Ω-Check® Concentric Neutral Resistance Tester
How good are your neutrals? Now there is an easy way to check them.
Intact neutrals are vital to the stability, reliability, & safety of a distribution system.
16
DVR Series - HV AC/DC Dividers
Models DVR-150 1-150 kV DC or AC to 1 kHz sinusoidal
Models DVR-300 1-300 kV DC or AC to 1 kHz sinusoidal
Many Need a DVR:Calibration Labs
HV Producers MeteringHV Apparatus OEM’s
17
+/- 120 kVdc @
10 mA
50 kVac @ 3 kVAShielded Cable Output
100 kVac/50 kVacDual Bushing Output
10 kVA Continuous
70 kVdc pri - secIsolation
Transformer
OEM & Lab AC/DC HV Power Supplies & Isolation Transformers
DC Power Packs5 kVdc – 100 kVdc3 mAdc – 20 mAdc
18