hide 1 aluminum - microsoft...hide 1 aluminum on-deck the most commonly used air vent head for...

3
Hide 1 Alu. DN – Inch 40 - 1 1/2" 50 - 2" 65 - 2 1/2" 80 - 3" 100 - 4" 125 - 5" 150 - 6" 200 - 8" 250 - 10" 300 - 12" A (mm) 175 228 250 274 316 386 460 533 680 800 B (mm) 120 140 160 200 220 250 285 343 406 460 a (mm) 131 180 190 212 239 292 358 400 510 585 D Flange connection acc. to any standard. Weight (kg) 2 3 3,5 4 6 11 18 30 44 77 Heating (Watt) 75 75 75 75 75 120 120 180 180 180 Max inlet speed m/s 1) 27 23 20 26 21 24 22 21 22 22 Inlet air flow in m 3 /h 1) 122 162 238 470 594 1060 1400 2375 3888 5598 Max inlet speed m/s 2) 28 26 20 30 21 25 22 23 21 22 Inlet air flow in m 3 /h 1) 127 184 239 543 594 1104 1400 2601 3711 5598 HIDE 1 ALUMINUM on-deck The most commonly used air vent head for ships. Made for installation outside on-deck. Ventilating all tanks on board for cargo, ballast water, wastewater, fresh water, lubricating oil, fuel oil, etc. Prevents water from entering the tanks. Options: Flame-/Bug-/Rat- sceen Heating /Winterization With mud chamber. Prevents mud from entering the valve (See Mud Chamber) Connection alternatives: Flanged, threaded or with weld butt Coating Other materials: Hot dip galvanized steel, stainless etc. For pressure drop and flow rate, visit our web page HIDE valves are approved by all the most common classification societies For pressure drop and flow rate, visit our web page www.gjerde.com A a B D Performance, weight and size 1) No screen 2) With screen 6 JOHN GJERDE BROCHURE 2016

Upload: others

Post on 07-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HIDE 1 ALUMINUM - Microsoft...HIDE 1 ALUMINUM on-deck The most commonly used air vent head for ships. Made for installation outside on-deck. Ventilating all tanks on board for cargo,

Hide 1 Alu.DN – Inch

40 - 1 1/2" 50 - 2" 65 - 2 1/2" 80 - 3" 100 - 4" 125 - 5" 150 - 6" 200 - 8" 250 - 10" 300 - 12"

A (mm) 175 228 250 274 316 386 460 533 680 800

B (mm) 120 140 160 200 220 250 285 343 406 460

a (mm) 131 180 190 212 239 292 358 400 510 585

D Flange connection acc. to any standard.

Weight (kg) 2 3 3,5 4 6 11 18 30 44 77

Heating (Watt) 75 75 75 75 75 120 120 180 180 180

Max inlet speed m/s1) 27 23 20 26 21 24 22 21 22 22

Inlet air flow in m3/h1) 122 162 238 470 594 1060 1400 2375 3888 5598

Max inlet speed m/s2) 28 26 20 30 21 25 22 23 21 22

Inlet air flow in m3/h1) 127 184 239 543 594 1104 1400 2601 3711 5598

HIDE 1 ALUMINUMon-deck

The most commonly used air vent head for ships. Made for installation outsideon-deck. Ventilating all tanks on board for cargo, ballast water, wastewater,fresh water, lubricating oil, fuel oil, etc. Prevents water from entering the tanks.

Options: � Flame-/Bug-/Rat- sceen � Heating /Winterization � With mud chamber. Prevents mud from entering the valve

(See Mud Chamber) � Connection alternatives: Flanged, threaded or with weld butt � Coating � Other materials: Hot dip galvanized steel, stainless etc. � For pressure drop and flow rate, visit our web page � HIDE valves are approved by all the most common classification

societies � For pressure drop and flow rate, visit our web page www.gjerde.com

Aa

B

D

Performance, weight and size

1) No screen 2) With screen

6 JOHN GJERDE BROCHURE 2016

Page 2: HIDE 1 ALUMINUM - Microsoft...HIDE 1 ALUMINUM on-deck The most commonly used air vent head for ships. Made for installation outside on-deck. Ventilating all tanks on board for cargo,

0

500

1000

1500

2000

2500

3000

0 100 200 300 400 500 600 700

Pres

sure

dro

p m

mW

G

Flow rate (m3/h)

DN100 no flame screen

DN125 no flame screenDN150 no flame screen

DN200 no flame screen

Dn250 no flame screen

Dn300 no flame screen

-

500

1 000

1 500

2 000

2 500

3 000

0 10 20 30 40 50 60 70 80 90 100

Pres

sure

dro

p m

mW

G

Flow rate (m3/h)

DN40 no flame screen

DN50 no flame screen

DN65 no flame screen

DN80 no flame screen

DN100 no flame screenDN125 no flame screen

Page 3: HIDE 1 ALUMINUM - Microsoft...HIDE 1 ALUMINUM on-deck The most commonly used air vent head for ships. Made for installation outside on-deck. Ventilating all tanks on board for cargo,

0

500

1000

1500

2000

2500

3000

0 100 200 300 400 500 600

Pres

sure

dro

p m

mW

G

Flow rate (m3/h)

DN100 with flame screenDN125 with flame screenDN150 with flame screenDN200 with flame screenDn250 with flame screenDn300 with flame screen

0

500

1000

1500

2000

2500

3000

0 10 20 30 40 50 60 70 80 90 100

Pres

sure

dro

p m

mW

G

Flow rate (m3/h)

DN40 with flame screenDN50 with flame screenDN65 with flame screenDN80 with flame screenDN100 with flame screenDN125 with flame screen