hf calibration coefficients (from data and db) status report murat ali guler, kadir ocalan (metu)...
TRANSCRIPT
![Page 1: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/1.jpg)
HF Calibration coefficients HF Calibration coefficients (from Data and DB) Status Report(from Data and DB) Status Report
Murat Ali Guler, Kadir Ocalan (METU)
Ferhat Ozok, Kerem Cankocak (Iowa)
HF meeting 29 July 2008
![Page 2: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/2.jpg)
Electromagnetic Channel Hadronic Channel
LED data Run 977
![Page 3: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/3.jpg)
Electromagnetic Channel Hadronic Channel
Source Data Gains from DBS
![Page 4: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/4.jpg)
Electromagnetic Channel Hadronic Channel
![Page 5: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/5.jpg)
Electromagnetic Channel
Hadronic Channel
= 33,35,38,39, =3
= 40, =63,67
= 32,38,39,40 =3
= 40 =63,67
![Page 6: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/6.jpg)
Low intensity LED Run 53000 (1350 V)
SPEi :
the single
photoelectron
response
Ci=(<N
pe>* SPE
i )-1
<Np.e
>~ 0.28/GeV
calib.cefff ~1/gaincalib.cefff ~1/gain
![Page 7: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/7.jpg)
Rechit occupancies from Cruzet 3 data
![Page 8: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/8.jpg)
HF Rechits in Cruzet 3 data
![Page 9: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/9.jpg)
Jet construction in Cruzet3
![Page 10: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/10.jpg)
LED run 53000
Low RMS
![Page 11: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/11.jpg)
(SPEV2
/SPEV1
)=(V2/V1)
= 5.08
Comparison of gains at different HV
![Page 12: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/12.jpg)
Electromagnetic Channel
Hadronic Channel
C1100
/C1150
Comparison of the calib Coefficients which are in DB
![Page 13: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/13.jpg)
C1100
/C1250
![Page 14: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/14.jpg)
C1100
/C1350
![Page 15: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/15.jpg)
C1150
/C1250
![Page 16: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/16.jpg)
C1150
/C1350
![Page 17: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/17.jpg)
C1250
/C1350
![Page 18: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/18.jpg)
Next step:Next step:
- we need more data (Low intensity LED runs) for HFM (and also HFP)
- more analysis of Cruzet data
-
![Page 19: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/19.jpg)
Backup slidesBackup slides
![Page 20: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/20.jpg)
Validation studies for HF Calibration
Documentation of Single Photoelectron Peak measurements and source for the calibration:
CMS IN 2006/037; 9'th ICATTP, World Scientiic pp 339-342 (2006); CMS IN 2006/044; CMS IN 2006/045; CMS IN 2006/138; CMS IN 2007/012 ;CMS IN 2007/018; CMS IN-2008/015; and more..
Preliminary results fromPreliminary results from
- SPE vs Data Base comparison- SPE vs Data Base comparison
- analysis of HF LED runs using SPE gains and Data Base gains- analysis of HF LED runs using SPE gains and Data Base gains
-Cosmic ray data analysis -Cosmic ray data analysis
calib. coefficients in DB 1150V calib. coefficients in DB 1150V gain ratio PMT(1250V)/PMT(1150V) =1.5gain ratio PMT(1250V)/PMT(1150V) =1.5 calib.cefff ~1/gaincalib.cefff ~1/gaincalib. coeff(1250V) = calib.coeff(1150V) * 0.66calib. coeff(1250V) = calib.coeff(1150V) * 0.66
![Page 21: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/21.jpg)
HF- hadronic channels
HF+ hadronic channels
HF Calibration coefficients from Data Base (GeV/fC) HF Calibration coefficients from Data Base (GeV/fC) frontier://Frontier/CMS_COND_20X_HCALfrontier://Frontier/CMS_COND_20X_HCAL
HF- electromagnetic channels
HF+ electromagnetic channels
Mean ~0.22 GeV/fCRMS ~0.06 GeV/fC
Mean ~0.20 GeV/fCRMS ~0.04 GeV/fC
Mean ~0.35 GeV/fCRMS ~0.09 GeV/fC
Mean ~0.31 GeV/fCRMS ~0.06 GeV/fC
![Page 22: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/22.jpg)
Electromagnetic channels (long fibers) Hadronic channels (short fibers)
Comparison of the calibration constants (Ci) of LED and DB gains (C_src)
Ci= (<N
pe>* SPE
i )-1 where <N
i> is the mean number of generated
photoelectrons/GeV and SPEi is the single photoelectron response of the ith channel
(similar method as in CMS IN 2007/018)
<Np.e
>~ 0.28/GeV from analysis of 100 GeV electron data taken in 2004 test beam.
HF+ Run 977 (100 K events) at low LED intensity (1350 V)
![Page 23: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/23.jpg)
Electromagnetic channels Hadronic channels
Mean = 0.92RMS=0.12
Mean = 0.91RMS=0.12
![Page 24: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/24.jpg)
RMS ~ 0.48 GeV
RMS ~ 0.75 GeV
RMS ~ 0.68 GeV RMS ~ 0.68
GeV
RMS ~ 0.43 GeV
Cruzet 3 Run 51403 (CSC, DT, HCAL trigger)
![Page 25: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/25.jpg)
HF Calibration coefficients from Data Base HF Calibration coefficients from Data Base frontier://Frontier/CMS_COND_20X_HCALfrontier://Frontier/CMS_COND_20X_HCAL
Electromagnetic channels (long fibers)
Cruzet 3 run 51403
(Shift in binning !)
Reflections of the gains in the cosmic muon data
![Page 26: HF Calibration coefficients (from Data and DB) Status Report Murat Ali Guler, Kadir Ocalan (METU) Ferhat Ozok, Kerem Cankocak (Iowa) HF meeting 29 July](https://reader036.vdocuments.us/reader036/viewer/2022081513/5697bfc51a28abf838ca6d85/html5/thumbnails/26.jpg)
HF Calibration coefficients from Data Base HF Calibration coefficients from Data Base frontier://Frontier/CMS_COND_20X_HCALfrontier://Frontier/CMS_COND_20X_HCAL
hadronic channels (short fibers)
Cruzet 3 run 51403
(Shift in binning !)
Reflections of the gains in the cosmic muon data