hartmann controls hartmann controls advantages advantages dynamic, progressive company dynamic,...
TRANSCRIPT
HARTMANN CONTROLSHARTMANN CONTROLS ADVANTAGESADVANTAGES Dynamic, progressive companyDynamic, progressive company 100% North American Quality products100% North American Quality products Dedicated sales and technical supportDedicated sales and technical support Certification workshop trainingCertification workshop training Aggressive pricing on all our productsAggressive pricing on all our productsPOWERED BY THOUGHT !POWERED BY THOUGHT ! DRIVEN BY TECHNOLOGY!DRIVEN BY TECHNOLOGY!
PRO-ACCPRO-ACCACCESS CONTROLACCESS CONTROL
EZ-ACCEZ-ACCHARTMANN CONTROLS
Enterprise SystemEnterprise System Basic SystemBasic System
INTRODUCTIONINTRODUCTION
Founded in 1998, Hartmann Founded in 1998, Hartmann Controls is a privately held, Controls is a privately held, 100% Canadian company that 100% Canadian company that develops and manufactures its develops and manufactures its own line of controllers and own line of controllers and software.software.
PRO-ACCPRO-ACCACCESS CONTROLACCESS CONTROL
EZ-ACCEZ-ACCHARTMANN CONTROLS
Enterprise SystemEnterprise System Basic SystemBasic System
FOUNDEDFOUNDED
Our products are sold in Our products are sold in
Canada, USA, Mexico, Australia,Canada, USA, Mexico, Australia,
India, Central and South AmericaIndia, Central and South America
PRO-ACCPRO-ACCACCESS CONTROLACCESS CONTROL
EZ-ACCEZ-ACCHARTMANN CONTROLS
Enterprise SystemEnterprise System Basic SystemBasic System
SOLD INSOLD IN
Some of the facilities that use HartmannSome of the facilities that use Hartmann
Controls products are;Controls products are;
Toronto District School Board uses Hartmann to control Toronto District School Board uses Hartmann to control more than 104 buildings all over TCPIPmore than 104 buildings all over TCPIP
Niagara Casino uses a custom system to Niagara Casino uses a custom system to control 5 million Cardholderscontrol 5 million Cardholders
PRO-ACCPRO-ACCACCESS CONTROLACCESS CONTROL
EZ-ACCEZ-ACCHARTMANN CONTROLS
Enterprise SystemEnterprise System Basic SystemBasic System
SAMPLE CUSTOMERSSAMPLE CUSTOMERS
EZ-ACCEZ-ACC
HARTMANN CONTROLSPRO-ACCPRO-ACC
ACCESS CONTROLACCESS CONTROLEZ-ACCEZ-ACC
EZ-ACC
Enterprise SystemEnterprise System Basic SystemBasic System
MAKING MAKING ACCESS CONTROL ACCESS CONTROL
SIMPLE !!!SIMPLE !!!
Simplicity is Efficiency !Simplicity is Efficiency !
PRO-ACCPRO-ACCACCESS CONTROLACCESS CONTROL
EZ-ACCEZ-ACCHARTMANN CONTROLS
Enterprise SystemEnterprise System Basic SystemBasic System
User friendly, non threatening GUIUser friendly, non threatening GUI 14 screens total to navigate14 screens total to navigate Point and click, drag and drop Point and click, drag and drop
operationoperation Convenient and versatile Convenient and versatile
administrationadministration
EZ-ACC
EZ-ACC CONTINUEDEZ-ACC CONTINUED
2 Door controller (up to 16 Doors),2 Door controller (up to 16 Doors), 1000 users maximum1000 users maximum Supports several reader technologies Supports several reader technologies
(Proximity, Biometrics, RF, Bar code, (Proximity, Biometrics, RF, Bar code,
mag stripe)mag stripe) Supports USB and TC/PIP Supports USB and TC/PIP
communication channels communication channels
PRO-ACCPRO-ACCACCESS CONTROLACCESS CONTROL
EZ-ACCEZ-ACC
EZ-ACC
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
EZ-ACC OVERVIEWEZ-ACC OVERVIEW
Panel FeaturesPanel Features Removable headersRemovable headers All headers neatly All headers neatly
organized and organized and clearly markedclearly marked
Communication LEDCommunication LED Active relay LEDActive relay LED 12vdc Power LED12vdc Power LED
PRO-ACCPRO-ACCACCESS CONTROLACCESS CONTROL
EZ-ACCEZ-ACCHARTMANN CONTROLS
Enterprise SystemEnterprise System Basic SystemBasic System
EZ-ACC PANELEZ-ACC PANEL
A new installationA new installation
produces a Simpleproduces a Simple
one page wizard one page wizard
Quick and EZQuick and EZ
PRO-ACCPRO-ACCACCESS CONTROLACCESS CONTROL
EZ-ACCEZ-ACCHARTMANN CONTROLS
Enterprise SystemEnterprise System Basic SystemBasic System
EZ-ACC WIZARDEZ-ACC WIZARD
Simple graphicsSimple graphics
and the basicand the basic
point and click,point and click,
drag and dropdrag and drop
feature isfeature is
employedemployed
throughout.throughout.
PRO-ACCPRO-ACCACCESS CONTROLACCESS CONTROL
EZ-ACCEZ-ACCHARTMANN CONTROLS
Enterprise SystemEnterprise System Basic SystemBasic System
EZ-ACC GRAPHICSEZ-ACC GRAPHICS
Designed and engineered for ease ofDesigned and engineered for ease of
installation and administration, EZ-ACCinstallation and administration, EZ-ACC
is the most user friendly, and mostis the most user friendly, and most
COST EFFECTIVECOST EFFECTIVE door access system door access system
on the marketon the market
PRO-ACCPRO-ACCACCESS CONTROLACCESS CONTROL
EZ-ACCEZ-ACC
EZ-ACC
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
EZ-ACC SUMMARYEZ-ACC SUMMARY
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
PRO-ACC is the next generation HARTMANN-CONTOLS Access Systems
Global Anti-pass backGlobal Anti-pass back
Active MapsActive Maps
10 Clients10 Clients
Control 4000 doorsControl 4000 doors
65000 Card Holders65000 Card Holders
Connectivity Via Connectivity Via
TCP/IP, USB, DialupTCP/IP, USB, Dialup
Alarm InterfacingAlarm Interfacing
And the list Goes OnAnd the list Goes On
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
PRO-ACC INTODUCTIONPRO-ACC INTODUCTION
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
•Panels are simply daisy chained via cat5 cable.
•TCP/IP, USB, Dialup Connectivity supported.
•Each channel supports any mix of panels.
•Up to 10 Workstations can be used to administer system
•System is fully distributed meaning all panels run completely independent of Server Software with the exception of Global Anti-Pass Back.
PRO-ACC TOPOLOGYPRO-ACC TOPOLOGY
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
Snap off headersSnap off headers Communication LedCommunication Led Led on all inputs and outputsLed on all inputs and outputs 12V and 5V led12V and 5V led AC LedAC Led All headers nicely organized and All headers nicely organized and
clearly marked.clearly marked. All controllers come in a custom All controllers come in a custom
enclosure with enough room for a enclosure with enough room for a 12V7AH battery and wiring.12V7AH battery and wiring.
They have on board They have on board communications and Power supply communications and Power supply for themselves as well as readers for themselves as well as readers and small peripherals. (Single and small peripherals. (Single Panel Design)Panel Design)
No more messing with multiple or old oversized panels to get your doors running.
PRO-ACC PANELSPRO-ACC PANELS
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
A new installation A new installation produces a one page produces a one page wizard which once wizard which once filled out will have your filled out will have your first panel and card up first panel and card up and running in and running in seconds.seconds.
New Installer Quote:
“Installing your system was as easy as pushing a button”
PRO-ACC WIZARDPRO-ACC WIZARD
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
Although our focus has been to keep it simple the PRO-ACC does not fall short on features.
With control of up to 40 communication channels via RS485, TCP/IP or dialup you can configure a system controlling hundreds of readers on buildings around the world.
With onboard capability for 65000 cardholders, 255 access privilege groups, 200 time zones and more our panels stand with the best.
PRO-ACC OVERVIEWPRO-ACC OVERVIEW
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
The PRO-ACC system is fully distributed meaning the panels once configured run 100% stand alone and each store up to 2000 transactions.
The PRO-ACC controls Doors (up to 4000), Elevators (up to 64 floors each), Input (alarm) points, and output points.
PRO-ACC OVERVIEWPRO-ACC OVERVIEW
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
HCDC- 4 (4 Door Controller) Supports 4 card readers HCDC- 4 (4 Door Controller) Supports 4 card readers
• • On Board Power Supply for powering panel and readers. On Board Power Supply for powering panel and readers. • Battery Back-Up Circuitry by 12VDC 7 Ah battery • Battery Back-Up Circuitry by 12VDC 7 Ah battery • 4 Dedicated Request to Exit Inputs, 4 Dedicated Door Contact Inputs, 4 • 4 Dedicated Request to Exit Inputs, 4 Dedicated Door Contact Inputs, 4
Dedicated Door Lock Outputs for easy setup Dedicated Door Lock Outputs for easy setup • 4 Auxiliary Outputs Controlled by Door Alarms, Card • 4 Auxiliary Outputs Controlled by Door Alarms, Card Shunting or Time Zones. Shunting or Time Zones. • On board firmware clock. • On board firmware clock. • Power Requirements: 12-16VAC @ 40VA transformer.• Power Requirements: 12-16VAC @ 40VA transformer.• Relays are Form C contact rated at 10A 125VAC.• Relays are Form C contact rated at 10A 125VAC.• On board Visual LED’s to indicate communications, Active • On board Visual LED’s to indicate communications, Active Relays, AC source, as well as state of inputs making it very service friendly. Relays, AC source, as well as state of inputs making it very service friendly.
The HCDC-4 is a stand-alone unit. Each Door Panel has a unique address . All panels The HCDC-4 is a stand-alone unit. Each Door Panel has a unique address . All panels operate fully independent of the server or other panels on the network once its database operate fully independent of the server or other panels on the network once its database is updated. is updated.
PRO-ACC 4 DOOR PRO-ACC 4 DOOR CONTROLLERCONTROLLER
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
HCDC- 2 (2 Door Controller) Supports 2 card readers HCDC- 2 (2 Door Controller) Supports 2 card readers
• • On Board Power Supply for powering panel and readers. On Board Power Supply for powering panel and readers. • Battery Back-Up Circuitry by 12VDC 7 Ah battery • Battery Back-Up Circuitry by 12VDC 7 Ah battery • 2 Dedicated Request to Exit Inputs, 2 Dedicated Door Contact Inputs, 2• 2 Dedicated Request to Exit Inputs, 2 Dedicated Door Contact Inputs, 2
Dedicated Door Lock Outputs, for easy setupDedicated Door Lock Outputs, for easy setup• 2Auxiliary Outputs Controlled by Door Alarms, Card • 2Auxiliary Outputs Controlled by Door Alarms, Card Shunting or Time Zones. Shunting or Time Zones. • On board firmware clock. • On board firmware clock. • Power Requirements: 12-16VAC @ 40VA transformer.• Power Requirements: 12-16VAC @ 40VA transformer.• Relays are Form C contact rated at 10A 125VAC.• Relays are Form C contact rated at 10A 125VAC.• On board Visual LED’s to indicate communications, Active • On board Visual LED’s to indicate communications, Active Relays, AC source, as well as state of inputs making it very service Relays, AC source, as well as state of inputs making it very service friendly. friendly.
The HCDC-2 is a stand-alone unit. Each Door Panel has a unique address . All The HCDC-2 is a stand-alone unit. Each Door Panel has a unique address . All panels operate fully independent of the server or other panels on the network once panels operate fully independent of the server or other panels on the network once its database is updated. its database is updated.
PRO-ACC 2 DOOR PRO-ACC 2 DOOR CONTROLLERCONTROLLER
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
HCEC- 8 (8 Floor Elevator Controller) Floor controlHCEC- 8 (8 Floor Elevator Controller) Floor control
•• Battery back up Circuitry Battery back up Circuitry •• On board firmware clockOn board firmware clock
•• Power Requirements: 12-16VAC @ 40VA transformer Power Requirements: 12-16VAC @ 40VA transformer•• Option Stand By battery 12VDC 7.0Ah Option Stand By battery 12VDC 7.0Ah• Control up to 64 floor by adding HCEC8 (8 floor Expanders).• Control up to 64 floor by adding HCEC8 (8 floor Expanders).•• Relays are Form C contact rated at 10A 125VAC Relays are Form C contact rated at 10A 125VAC•• On board LED to indicate communications, Active Relays, AC source, as On board LED to indicate communications, Active Relays, AC source, as well as the state of the inputs making it very service friendly. well as the state of the inputs making it very service friendly.
The Elevator Controller is a stand-alone unit similar to our door controllers. Each The Elevator Controller is a stand-alone unit similar to our door controllers. Each panel has a unique address. When a valid card is presented, all relays that card is panel has a unique address. When a valid card is presented, all relays that card is good for will be activated for the programmed time. good for will be activated for the programmed time.
PRO-ACC ELEVATOR PRO-ACC ELEVATOR CONTROLLERCONTROLLER
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
HCSIOC- 8 (Smart Input / Output Controller) 8 Input and Output controller.HCSIOC- 8 (Smart Input / Output Controller) 8 Input and Output controller.•• 8 Unsupervised Input Control. 8 Unsupervised Input Control.•• 8 Relay Outputs. 8 Relay Outputs.•• On board firmware clock. On board firmware clock.•• Battery back up Circuitry. Battery back up Circuitry.•• Power Requirements: 12-16VAC @ 40VA transformer. Power Requirements: 12-16VAC @ 40VA transformer.•• Option Stand By battery 12VDC 7.0Ah. Option Stand By battery 12VDC 7.0Ah.•• Relays are Form C contact rated at 10A 125VAC. Relays are Form C contact rated at 10A 125VAC.•• On board LED to indicate communications, Active Relays, AC source, as On board LED to indicate communications, Active Relays, AC source, as well as the state of the inputs making it very service friendly. well as the state of the inputs making it very service friendly. The Smart I/O8 is a stand-alone unit similar to our door controllers. Each I/O Panel has a The Smart I/O8 is a stand-alone unit similar to our door controllers. Each I/O Panel has a unique address. Inputs are programmed to arm according to an assigned time zone. Outputs unique address. Inputs are programmed to arm according to an assigned time zone. Outputs can be programmed to activate according to an assigned time zone or to follow input for buzzer can be programmed to activate according to an assigned time zone or to follow input for buzzer activation, etc. This Panel operates fully independent of the server or other panels on the activation, etc. This Panel operates fully independent of the server or other panels on the networknetwork
PRO-ACC I/O PRO-ACC I/O CONTROLLERCONTROLLER
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
Quick Overview of System FeaturesQuick Overview of System Features 4000 Door Capacity4000 Door Capacity 65,000 Card capacity65,000 Card capacity 200 Timezones200 Timezones 255 Access Privileges255 Access Privileges 32 Holidays32 Holidays Supports Multiple Reader Technologies (Proximity, Wiegand, Biometrics, Supports Multiple Reader Technologies (Proximity, Wiegand, Biometrics,
Magstripe, Barcode)Magstripe, Barcode) Multiple card formats and facility codesMultiple card formats and facility codes Global Anti-PassbackGlobal Anti-Passback Timed Anti-PassbackTimed Anti-Passback Emailing of alarms and eventsEmailing of alarms and events Up to 100 Controllers per communication channel, up to 40 communication Up to 100 Controllers per communication channel, up to 40 communication
channelschannels Multi Site ControlMulti Site Control
PRO-ACC FEATURESPRO-ACC FEATURES
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
Photo Badging & VerificationPhoto Badging & Verification Time & AttendanceTime & Attendance Active Graphical MapsActive Graphical Maps Multi LanguageMulti Language Elevator ControllersElevator Controllers DVR and CCTV Integration (Bosh, Toshiba, Samsung, Open Eye)DVR and CCTV Integration (Bosh, Toshiba, Samsung, Open Eye) Communicate via Direct USB to RS422, LAN / WAN and Dial-upCommunicate via Direct USB to RS422, LAN / WAN and Dial-up On-board power supplyOn-board power supply Visual Diagnostic LED’sVisual Diagnostic LED’s Quick Connect TerminalsQuick Connect Terminals Separate Door and Request to Exit InputsSeparate Door and Request to Exit Inputs Integrated Backup / Purge UtilityIntegrated Backup / Purge Utility
Quick Overview of System FeaturesQuick Overview of System Features
PRO-ACC FEATURES PRO-ACC FEATURES CONTINUEDCONTINUED
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
The PRO-ACC system has been installed in some very prestigious sites such as NASA, North The PRO-ACC system has been installed in some very prestigious sites such as NASA, North West Tel, Several US Banks, Niagara Casino just to mention some.West Tel, Several US Banks, Niagara Casino just to mention some.
To date our largest installation is the Toronto District School board located in Ontario Canada. To date our largest installation is the Toronto District School board located in Ontario Canada. It is one of the largest 4 school boards in North America. They have approximately 600 It is one of the largest 4 school boards in North America. They have approximately 600 buildings spread out across the Toronto district.buildings spread out across the Toronto district.
The PRO-ACC system is currently controlling 104+ buildings with all panels networked back to The PRO-ACC system is currently controlling 104+ buildings with all panels networked back to the central PRO-ACC server. There are thousands of users and cardholders are being added the central PRO-ACC server. There are thousands of users and cardholders are being added and removed daily. They are planning to add most of their buildings to this system.and removed daily. They are planning to add most of their buildings to this system.
To date the School board Is very pleased with the performance of the PRO-ACC system and we To date the School board Is very pleased with the performance of the PRO-ACC system and we have had no complaints of any kind.have had no complaints of any kind.
If PRO-ACC can control such a large site successfully we are sure you will be pleased with the If PRO-ACC can control such a large site successfully we are sure you will be pleased with the system Performance for your site.system Performance for your site.
PRO-ACC OVERVIEWPRO-ACC OVERVIEW
PRO-ACC Top 10 FeaturesPRO-ACC Top 10 Features
1.)1.) Door Controls are available in 2 and 4 reader configuration (Saves $ and space Door Controls are available in 2 and 4 reader configuration (Saves $ and space on larger jobs)on larger jobs)
2.)2.) Time & Attendance Calculator (Using In and Out readers)Time & Attendance Calculator (Using In and Out readers)
3.)3.) PRO-ACC Software is always included PRO-ACC Software is always included-No license fees, no add on modules and always free updates from the web-No license fees, no add on modules and always free updates from the web
4.)4.) Alarm InterfaceAlarm Interface-Configure a reader to allow certain individuals to Arm and Disarm the Alarm panel with -Configure a reader to allow certain individuals to Arm and Disarm the Alarm panel with there access card. When activated an audible and visual notification is given. Review there access card. When activated an audible and visual notification is given. Review your history reports to who armed and disarmed the system.your history reports to who armed and disarmed the system.
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
5.) Customize the Logon menu with your own corporate logo5.) Customize the Logon menu with your own corporate logo
6.) DVR Integration6.) DVR Integration-Fully integrates with Open Eye, Bosch, Honeywell, Samsung, PC Open & Toshiba -Fully integrates with Open Eye, Bosch, Honeywell, Samsung, PC Open & Toshiba -Trigger a camera on an event to display in the PRO-ACC Video window, for quick -Trigger a camera on an event to display in the PRO-ACC Video window, for quick investigation of an abnormal incident.investigation of an abnormal incident.- Click on an events date and time to call out to the DVR to see what was recorded. - Click on an events date and time to call out to the DVR to see what was recorded. Review the video eventsReview the video events
7.) Import Function7.) Import Function-The Import function allows you to quickly take an existing database in a CSV format and -The Import function allows you to quickly take an existing database in a CSV format and import it into our system. This speeds up the process for setting up your cardholders. import it into our system. This speeds up the process for setting up your cardholders. This can also be used to tie into an HR system eliminating repetitive cardholder entry.This can also be used to tie into an HR system eliminating repetitive cardholder entry.
PRO-ACC TOP 10 PRO-ACC TOP 10 FEATURES 2FEATURES 2
PRO-ACC Top 10 FeaturesPRO-ACC Top 10 Features
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
8.) First Card In8.) First Card In- this feature will not unlock the door until the first valid user presents a card. This is - this feature will not unlock the door until the first valid user presents a card. This is great protection from having your door unlock on a schedule (snow day feature!)great protection from having your door unlock on a schedule (snow day feature!)
9.) Timed Anti-Pass Back9.) Timed Anti-Pass Back- Extremely flexible features, which prevent sharing of cards for a predetermined time. - Extremely flexible features, which prevent sharing of cards for a predetermined time. An example would be for paid parking; once the cad is used, it would not be able to An example would be for paid parking; once the cad is used, it would not be able to work on that reader for the predetermined time.work on that reader for the predetermined time.
10.) Site Code Update10.) Site Code Update-When dong takeovers of an existing system with readers and cards and you do not -When dong takeovers of an existing system with readers and cards and you do not know the site/facility code, simply enter ‘0” into our system for site, code and we will know the site/facility code, simply enter ‘0” into our system for site, code and we will create a file when the cards are used. When card’s have been used simply click on create a file when the cards are used. When card’s have been used simply click on Update Site codes to properly assign all “0” site codes to appropriate site code that was Update Site codes to properly assign all “0” site codes to appropriate site code that was registered.registered.
PRO-ACC TOP 10 PRO-ACC TOP 10 FEATURES 3FEATURES 3
PRO-ACC Top 10 FeaturesPRO-ACC Top 10 Features
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
Simplicity Simplicity On all fronts from configuring what is needed to installing to On all fronts from configuring what is needed to installing to
administering to servicing.administering to servicing. CompetitiveCompetitive
The most competitive full-featured system.The most competitive full-featured system. DependabilityDependability
Over 99 % Quality AssuranceOver 99 % Quality Assurance In house software and hardware developmentIn house software and hardware development
AvailabilityAvailability North American Manufactured makes product readily availableNorth American Manufactured makes product readily available Typically shipped within 48 hoursTypically shipped within 48 hours
SupportSupport After hours support 8am to 11pm 7 days a week.After hours support 8am to 11pm 7 days a week.
PRO-ACC SUMMARYPRO-ACC SUMMARY
PRO-ACC SUMMARYPRO-ACC SUMMARY
PRO-ACCPRO-ACC EZ-ACCEZ-ACCACCESS CONTROLACCESS CONTROL
HARTMANN CONTROLSEnterprise SystemEnterprise System Basic SystemBasic System
Powered by Thought!
Driven by Technology!
We look forward to any questions or comments you may have to help us serve you better.
Hartmann Controls, Ontario, Canada
www.hartmann-controls.com
North America Toll Free- 1-877-411-0101
Thank YOUThank YOU