handbook for magnaflux y6 electromagnetic yoke nov 11 english printable version

4
L-10 MAGNETISING COIL Developed for testing shafts, spindles and similar components. Features: Ideal for inspecting for transverse cracks Components are magnetised and demagnetised with the same coil 110V operation Wet or dry Magnetic Particle Inspection (MPI) method can be used Footswitch provides continuous control Magnetic particle colours available: Dry method – grey, black, red Wet method – black, red, fluorescent Y6 YOKE KITS In kit form, the Y6 Yoke is supplied complete with black magnetic ink, white contrast paint and a wire brush and duster, all housed in a strong attractive carrying case. A light source, attached to one leg of the Y6 Yoke, is activated by the magnetic field and switches on automatically during testing. Ideal for darker corners. Light source for Y6 Yoke – part number 002L115. HANDB MAG Y6 ELECTROM PART NUMBERS: 0 Handbook for Magnaflux Y6 Electromagnetic Yoke BOOK FOR GNAFLUX MAGNETIC YOKE 001Y022, 001YO20, 001Y004

Upload: nobody121

Post on 04-Jan-2016

26 views

Category:

Documents


10 download

DESCRIPTION

Y6 Handbook

TRANSCRIPT

L-10 MAGNETISING COIL Developed for testing shafts, spindles and similar components. Features: � Ideal for inspecting for transverse cracks � Components are magnetised and

demagnetised with the same coil � 110V operation � Wet or dry Magnetic Particle Inspection

(MPI) method can be used � Footswitch provides continuous control Magnetic particle colours available: � Dry method – grey, black, red � Wet method – black, red, fluorescent

Y6 YOKE KITS In kit form, the Y6 Yoke is supplied complete with black magnetic ink, white contrast paint and a wire brush and duster, all housed in a strong attractive carrying case. A light source, attached to one leg of the Y6 Yoke, is activated by the magnetic field and switches on automatically during testing. Ideal for darker corners. Light source for Y6 Yoke – part number 002L115.

HANDBOOK FOR

MAGNAFLUX

Y6 ELECTROMAGNETIC YOKE

PART NUMBERS: 001Y022, 001YO20, 001Y004

Handbook for Magnaflux Y6 Electromagnetic Yoke

HANDBOOK FOR

MAGNAFLUX

Y6 ELECTROMAGNETIC YOKE

001Y022, 001YO20, 001Y004

PREPARED INKS Flash point

(°C min) (PMCC)

Viscosity @ 21°C

(cS)

Specific gravity

Particle size (µm)

Settlement volume (%V/V) (as supplied)

Magnaglo 410HF* A prepared ink consisting of Magnaglo MG410 in a high flash kerosene of low odour

93

3.45

0.81

7 to 25

0.12

Magnaglo 14HF* A prepared ink consisting of Magnaglo 14A in a high flash kerosene of low odour

93

3.45

0.81

2 to 25

0.25

Magnavis 7HF* A prepared ink consisting of Magnaflux 7C in a high flash kerosene of low odour

93

3.45

0.81

0.6 to 2.5

2.5

*Available in both aerosol and bulk format

DRY POWDERS 1 Grey Maximum working temperature 315°C

Magnaflux dry powders offer a range of colour to give good contrast on as wide a variety of finishes as possible. In the event of contrast not being ideal for inspection, a thin layer of Magnaflux WCP-2 White Contrast Paint can be applied prior to testing. All powders are of closely controlled particle size and shape and have desirable magnetic properties. For best results application should be as a cloud applied near the surface while the current is flowing. Excess powder settling out can be blown off.

3A Black Maximum working temperature 230°C 8A Red Maximum working temperature 175°C

WCP-2 White Contrast Paint

Magnaflux WCP-2 is a quick-drying white contrast paint which can be applied as a thin coating prior to testing where enhanced contrast is required.

SPECIFICATIONS Magnaflux, Magnaglo and Magnavis concentrates, prepared inks and dry powders meet the requirements of ASTM E-1444 with oil suspended inks and concentrates meeting AMS specifications, plus appropriate industrial and Government specifications, Certifications are available on request.

Certificate of Conformity

Certified that the above item conforms to and meets the requirements of the following: EC Directives Specifications 73/23/EEC ASME V ART7 89/392/EEC ASTM E-709 91/368/EEC ASTM E-1444 89/336/EEC (Emissions) EN-ISO 9934-3 92/31/EEC (Emissions) MIL-STD-271 Certificate is issued under the auspices of the Equipment Product Manager (2011): Magnaflux (A Division of ITW Ltd), Faraday Road, South Dorcan Industrial Estate, Swindon, Wiltshire, SN3 5HE, UK. Tel: +44 (0)1793 524566 Fax: +44 (0)1793 490459 Email: [email protected] www.magnaflux.com

MAGNETIC FIELD RISK Persons susceptible to strong magnetic fields, including those with pacemakers, are advised not to use or approach this equipment without seeking professional advice.

Y6 Yoke Serial number:

TECHNICAL SPECIFICATION AC voltage (V) 50 110 115 230 Frequency (Hz) 50 50 60 50 DC voltage (V) - 12 - 12 Supply current (A) in air AC 15 3.5 3.5 2.3

DC - 8.5 8.5 2.5 Weight (Kg) lifted at 140mm pole spacing AC 10.5 10.5 10.5 10.5

DC - 32.0 - 32.0 Part number 001Y022 001Y004 - 001Y020

AC Tangential Field Strength in kA/m at the central point between the poles on a 500 x 250 x 10 mm steel plate

Pole spacing 35mm 12kA/m 140mm 2kA/m 250mm 1.4kA/m

The light source and leg assembly, which is activated by the magnetic field, is switched on automatically during testing. Ideal for dark corners. Part number: 002L115. CERTIFIED TEST WEIGHTS Available for both AC and DC. AC Test Weight (4.5Kg) Part Number: 026T018B DC Test Weight (18Kg) Part Number: 026T018A

USING THE Y6 YOKE

Note 1: This Yoke can be supplemented by a magnetising coil for inspecting mounted spindles, rear axles and other light parts for transverse cracks only.

Note 2: Fluorescent magnetic ink with high

intensity black light improves the sensitivity of both the Y6 Yoke and L10 Magnetising Coil

1. Place the Yoke on the workpiece perpendicular to the direction of the cracks. Double jointed articulated legs can be moved in two directions at each joint.

2. You can then adjust the spacing between the legs from about 25 to 250mm and contour the feet to produce a good flat contact point on parts with irregular shapes.

3. Trigger the switch, apply the inspection medium, either wet or dry, and surface crack indications form immediately. You can proceed rapidly in a series of steps each finding cracks in a 150 x 150mm area.

WARNINGS � DO NOT smoke while performing NDT � DO NOT operate the Y6 Yoke for longer than 3 seconds ON followed by 10 seconds

OFF, that is a 23% duty cycle � If the Yoke is too hot to hold in the bare hand it is a sign that the duty cycle has been

exceeded. Wait for the Yoke to cool before continuing. � DO NOT use any means to permanently operate the Yoke switch � DO NOT use the supply cable to pull, lift or carry the equipment � When the Yoke is switched OFF the magnetic attraction to the tested component will

be weakened and either the part or the Yoke could fall and cause injury 4. Laminar magnetic iron provides maximum efficiency with light weight. The trigger

switch is easily operated without changing hand positions. 5. As magnetic contact exists only between the Yoke and the test piece, the switch,

completely enclosed by a rubber gasket, is the only break in the electrical circuit. Thus arcing on the part itself is impossible.

PARTS LIST

Item Description Part number Quantity 1 Cable, 3 core 001C065 3.75 metre 2 Bush 014B027 1 3 Leg/foot assembly 70617A3 2 4 Switch kit:

� Switch � Rubber cover � Insulated metal cover � Screws

005K026

1

5 Cable cover 17771A3 1

WARNING DO NOT REPLACE ANY PARTS WITH OTHER THAN THOSE RECOMMENDED BY MAGNAFLUX.

SAFETY DATA FLAMMABILITY The Y6 Yoke is intended to be used in conjunction with appropriate chemicals as a Non Destructive means of Testing (NDT) for defects, such as cracks, on a wide range of manufactured components. Some chemicals may produce a flammable atmosphere at the point of use and it is important that the testing is carried out in a well ventilated place and that all sources of ignition are excluded. Good quality NDT chemicals such as Magnaflux magnetic inks and powders are formulated to minimise the risk of a flammable atmosphere when correctly used. ELECTRICAL Ensure that the protective conductor (earth) is continuous from the Y6 laminations through suitable connections to the electrical supply. Recommendations: � A Residual Current Circuit Breaker (RCCB) or Earth Leakage Circuit Breaker (ELCB)

should be used if the Yoke supply is greater than 50V � If the switch area of the Yoke becomes wet with kerosene or water it should be

disconnected from its supply until the area has dried � In damp conditions select either a 42V or 48V Yoke, or a 110V Yoke operated from a

supply that is centre tapped to earth (55V-0-55V) � If the Y6 shows signs of malfunctioning or if cracks appear in the casing, the Yoke

should be removed from service immediately and examined by a qualified electrician. Cracking is usually caused by dropping the Yoke or by twisting the articulated legs.

MAINTENANCE Before using the Yoke: � Ensure it is physically undamaged � Ensure the cable is free from cuts which expose the wiring � Tighten the articulated joints if they are excessively loose It is a legal requirement in many countries that the electrical safety of equipment is checked periodically, commensurate with use, but at least once a year. The basic tests required are to check the condition and effectiveness of the electrical insulation and the continuity of the protective conductor (earth). These tests can be performed using as Portable Appliance Tester (PAT) or Portable Appliance Checker (PAC).