grating lawson aquatics™ parallel gratin neptune-benson ... · technical data sheet 5/8” male...

3
5/8” MALE END VIEW All drawing dimensions supplied by Neptune-Benson, are for reference only. All cad files were created using AutoCAD file format (*dwg) and are presented as a service to our customers. Errors sometimes occur during this process and with software incompatibility upon opening a file. Neptune- Benson, and/or any authorized distributor of our products will not be held responsible for problems arising from files which have been converted and does not warranty the documents against deficiencies or typographical errors of any kind. We recommend that all measurements are verified with actual physical product before any custom fabrication in the field occurs. 3/8” Opening to accept male end 3/8” 5/8” TOP VIEW – GRATING BAR FEMALE END VIEW 6” 6” Radial supports to be placed no more than 6” apart center to center, on larger side of the radius gutter ASSEMBLY – PLAN VIEW A A SECTION A-A 18” ASSEMBLY 3/8” 1-3/8” 18” 1-3/8” SECTION A-A 6” ASSEMBLY 1-3/8” 6” GRATING SIZES Part Number (White) Description PA-R**-WT Grate Parallel **” Note: ** represents width in inches (available 6” to 18” in increments of 1”) Expansion joint to be placed approximately every 15 feet, expansion joint width1/4” GRATE SURFACE DETAIL 24” 3/16” R 06/20/19 Toll: (800) 832-8002 Tel: +1 (401) 821-2200 Fax: (401) 821-7129 www.evoqua.com/neptune-benson GRATING Neptune-Benson® Parallel Grating – Radial 6”-18”

Upload: others

Post on 17-Mar-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GRATING Lawson Aquatics™ Parallel Gratin Neptune-Benson ... · Technical Data Sheet 5/8” MALE END VIEW GRATING Lawson Aquatics™ Parallel Grating – Radial 6”-18” All drawing

Technical Data Sheet

5/8”

MALE END VIEW

Lawson Aquatics™ Parallel Grating – Radial 6”-18” GRATING

All drawing dimensions supplied by Neptune-Benson, are for reference only. All cad files were created using AutoCAD file format (*dwg) and are presented as a service to our customers. Errors sometimes occur during this process and with software incompatibility upon opening a file. Neptune-Benson, and/or any authorized distributor of our products will not be held responsible for problems arising from files which have been converted and does not warranty the documents against deficiencies or typographical errors of any kind. We recommend that all measurements are verified with actual physical product before any custom fabrication in the field occurs.

3/8”

Opening to accept male end 3/8”

5/8”

TOP VIEW – GRATING BAR

FEMALE END VIEW

6”

6”

Radial supports to be placed no more than 6” apart center to center, on larger side of the radius gutter

ASSEMBLY – PLAN VIEW

A

A

SECTION A-A 18” ASSEMBLY

3/8”

1-3/8”

18” 1-3/8”

SECTION A-A 6” ASSEMBLY

1-3/8”6”

GRATING SIZES

Part Number (White) Description

PA-R**-WT Grate Parallel **”

Note: ** represents width in inches (available 6” to 18” in increments of 1”)

Expansion joint to be placed approximately every 15 feet, expansion joint width1/4”

GRATE SURFACE DETAIL

24” 3/16”

R 06/20/19

GRATINGLawson Aquatics® Perpendicular Grating

Toll: (800) 832-8002 Tel: +1 (401) 821-2200 Fax: (401) 821-7129 www.evoqua.com/neptune-benson

GRATINGLawson Aquatics® Perpendicular Grating

Toll: (800) 832-8002 Tel: +1 (401) 821-2200 Fax: (401) 821-7129 www.evoqua.com/neptune-benson

GRATINGNeptune-Benson® Parallel Grating – Radial 6”-18”

Page 2: GRATING Lawson Aquatics™ Parallel Gratin Neptune-Benson ... · Technical Data Sheet 5/8” MALE END VIEW GRATING Lawson Aquatics™ Parallel Grating – Radial 6”-18” All drawing

Lawson Aquatics™ Parallel Grating – Radial 6” – 18”

Technical Data Sheet

GRATING

QuietFlow® GratesDesigned to capture and disperse water surgein a matter of inches and speed flow rate.

FEATURES

Unique ergonomically‐designed diamond ridge pattern todeflect standing water two ways, ensuring that decks are safer.

Wet or Dry – with rigid, non‐slip comfort under foot.§ QuietFlow grate complies with federal ADA regulations.§ Available in 3 standard colors – White, Gray, and Bone.§ Ten year warranty.

SPECIFICATIONS

Size 6”to18”widthsin1”incrementsMaterial PVCSurface Non‐SkidsurfaceGrate White,Gray,andBoneOpenArea 37.5%

RatingASTMG‐154750HoursUVASTMC‐1028staticcoefficientoffriction,wetanddryASTME‐661092loadtofailureanddeflection@200#

SuperGrip™ Grates

RADIUS 

Sections of UV stabilized PVC grating in 24” long pieces connected end  to  end  to  accommodate  the  length  of  the  radius  sections.  The width  is  in multiples of one  inch,  from 6”  to 18” wide.   For sizes  6‐10”  there  shall  be  cross  supports  spaced  at  6”  (max) intervals around the perimeter to span the gutter opening, and to accept the parallel bars. Place supports at 4” OC for sizes 11‐18”.  The  cross  supports are designed  to maintain  the  space between the  pieces  not  to  exceed  0.375”.    The  parallel  radius  bars  are designed  to attach directly  into  the  straight  sections  for a  clean transition.    Field  bend  radii  12  feet  and  greater.  Radii  between 12’‐5’ must be factory bent and field installed. Not recommended for radii smaller than 5’. 

STRAIGHT 

Sections of UV stabilized PVC grating  in on foot  lengths x widths of 6” to  18”  in  one  inch  increments.    Individual  pieces  snap  together  to accommodate  the  length of  the straight sections.   The  top surface of both types of parallel grating shall have a raised diamond ridge design to create good friction, wet or dry, ensuring that decks are safer with rigid, non‐slip comfort underfoot. 

Leading  commercial/competition  pool  designers,  aquatics  consultants and contractors require that equal consideration be given to  each  and  every  element  used  to  create  and  deliver  spectacular, highly functional pool facility. 

To meet the requirements of indoor and outdoor commercial pools, competition pools and the most distinctive pool designs in the aquatics industry, Neptune-Benson has designed a high tech, high performance system of parallel grating, either straight or radius, that follows the contours of any rim-flow pool design. Our Quiet-Flow parallel grating is designed to capture water surge in a matter of inches, and speed flow and disperse rate. The result is a significantly quieter, faster pool without the excessive cost of building sloped or wider gutters.

R 06/20/19

GRATINGLawson Aquatics® Perpendicular Grating

Toll: (800) 832-8002 Tel: +1 (401) 821-2200 Fax: (401) 821-7129 www.evoqua.com/neptune-benson

GRATINGLawson Aquatics® Perpendicular Grating

Toll: (800) 832-8002 Tel: +1 (401) 821-2200 Fax: (401) 821-7129 www.evoqua.com/neptune-benson

GRATINGNeptune-Benson® Parallel Grating – Radial 6”-18”

Page 3: GRATING Lawson Aquatics™ Parallel Gratin Neptune-Benson ... · Technical Data Sheet 5/8” MALE END VIEW GRATING Lawson Aquatics™ Parallel Grating – Radial 6”-18” All drawing

Lawson Aquatics™ Parallel Grate – Radial 6” – 18”Technical Data Sheet

GRATING

ScenarioA

WidthIn.

BRadiusFt.

CSupportSpacing

FactoryBend

FieldBend

1 6”‐11” 5’‐15’ 6”OC YES NO2 12”‐

18” 5’‐15’ 4”OC YES NO3 6”‐11” >15’ 6”OC ON

REQUEST YES4 12”‐

18” >15’ 4”OC ONREQUEST YES

(C) 6” OC (MAX.)

R < 15’ (B)

R < 15’ (B)

(C) 4” OC (MAX.)

(C) 6” OC (MAX.)

R > 15’ (B)

R > 15’ (B)

(C) 4” OC (MAX.)

SUPPORT BARS

GRATING BARS

(A) 6”-11”

(A) 12”-18”

(A) 6”-11”

(A) 12”-18”

1

2

3

4

R 06/20/19

GRATINGLawson Aquatics® Perpendicular Grating

Toll: (800) 832-8002 Tel: +1 (401) 821-2200 Fax: (401) 821-7129 www.evoqua.com/neptune-benson

GRATINGLawson Aquatics® Perpendicular Grating

Toll: (800) 832-8002 Tel: +1 (401) 821-2200 Fax: (401) 821-7129 www.evoqua.com/neptune-benson

GRATINGNeptune-Benson® Parallel Grating – Radial 6”-18”