gn - planhubapp.s3-us-west-2.amazonaws.com

17
ABOVE FINISH FLOOR ACCESS PANEL ACCESSIBLE ACOUSTICAL TILE ADHESIVE ADJUSTABLE, ADJACENT AUTHORITY HAVING JURISDICTION ALUMINUM APPROVED, APPROVAL APPROXIMATE ARCHITECTURAL ASBESTOS CONTAINING MATERIAL BEAM BETWEEN BLOCKING BOARD BOTTOM OF BUILDING CARPET CEILING CENTER LINE CERAMIC TILE CLEAR(ANCE) COLUMN CONCRETE CONCRETE MASONRY UNITS CONSTRUCTION CONSTRUCTION MANAGER CONTINUOUS CONTROL JOINT CORNER GUARD COUNTERFLASHING COUNTER SINK DEGREE DEMOLITION DETAIL DIAMETER DIMENSION DISPENSER DRAWINGS DRINKING FOUNTAIN DOWNSPOUT EACH EXTERIOR INSULATION AND FINISH SYSTEM ELECTRIC(AL) EQUAL EQUIPMENT ELECTRIC WATER COOLER ELECTRICAL PANELBOARD EXISTING EXPANSION EXPANSION JOINT EXTERIOR FINISH FINISHED FLOOR FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FIREPROOF, FIRE PROTECTION FLOOR FLOOR DRAIN FLUORESCENT FIBER REINFORCED GYPSUM FIBER REINFORCED PLASTIC FIBER RETARDANT TREATED FOUNDATION FURNISH GAUGE GENERAL CONTRACTOR GLASS, GLAZING GRAB BAR GYPSUM BOARD HARDWARE HARDWOOD HEIGHT HIGH DENSITY FIBERBOARD HOLLOW CORE HOLLOW METAL HOSE BIB HORIZONTAL HOUR INCANDESCENT INSIDE DIAMETER INSULATION INTERIOR LANDLORD, LEASE LINE AFF AP ACC ACT ADH ADJ AHJ AL APPD APPROX ARCH ACM BM BTWN BLKG BD B.O. BLDG CPT CLG CL CT CLR COL CONC CMU CONST CM CONT CJ CG CFLG CTSK DEG DEMO DTL DIA DIM DISP DWG DF DS EA EIFS ELEC EQ EQUIP EWC EP EXG EXP EJ EXT FIN FF FE FEC FP FLR FD FLUOR FRG FRP FRT FDN FURN GA GC GL GB GYP BD HDW HDWD HT HDF HC HM HB HOR HR INCAN ID INSUL INT LL LAVATORY LINEAR LINEAR FEET LIGHTING MASONRY MATERIAL MAXIMUM MECHANICAL MEDIUM DENSITY FIBERBOARD METAL MEZZANINE MANUFACTURER MINIMUM MISCELLANEOUS MASONRY OPENNING MOUNTED NOMINAL NOT IN CONTRACT NUMBER NOT TO SCALE ON CENTER OPENING OPPOSITE OUTSIDE DIAMTER OWNER FURNISHED/ CONTRACTOR INSTALLED OWNER FURNISHED/ OWNER INSTALLED OVERHEAD OVERHEAD COILING GRILLE PAINT PANEL PARTICLE BOARD PARTITION PLASTIC LAMINATE PLATE PLUMBING PLYWOOD QUANTITY QUARRY TILE RADIUS REFER TO REQUIRED RESILIENT REVISION RISER ROOF DRAIN ROOM ROUGH OPENING RUBBER BASE SCHEDULE SECTION SHEET SIMILAR SIMILAR, OPPOSITE HAND SLOTTED WALL BOARD SOLID CORE SPECIFICATION(S) SQUARE FEET STAINLESS STEEL STAIN, SEAL & VARNISH STANDARD STEEL STRUCTURAL SUSPENDED TEMPERED, TEMPERATURE, TEMPORARY THICK(NESS) TONQUE & GROOVE TOP OF TREAD TYPICAL UNLESS NOTED OTHERWISE VINYL BASE VINYL COMPOSITION TILE VINYL WALL COVERING VERTICAL VERIFY IN FIELD VENT THROUGH ROOF WATER CLOSET WATER HEATER WATERPROOF WITH WITHOUT WOOD LAV LIN LF LTG MAS MATL MAX MECH MDF MTL MEZZ MFR MIN MISC MO MTD NOM NIC NO. NTS O.C. OPG OPP OD OFCI OFOI OH OHCG PT PNL PBD PTN PLAM PL PLBG PLYWD QTY QT RAD REF REQ RES REV R RD RM RO RB SCHED SECT SHT SIM SIM OPP SWB SC SPEC(S) SF STS SSV STD STL STRUCT SUSP TEMP THK T&G T.O. T TYP U.N.O. VB VCT VWC VERT VIF VTR WC WH WP W/ W/O WD LOCAL AUTHORITY: BUILDING DEPARTMENT: CITY OF SAN ANTONIO BUILDING DEPT 1901 SOUTH ALAMO STREET SAN ANTONIO, TX 78204 PH: 210.207.1111 BUILDING CODE: 2018 INTERNATIONAL BUILDING CODE MECHANICAL CODE: 2018 INTERNATIONAL MECHANICAL CODE PLUMBING CODE: 2018 INTERNATIONAL PLUMBING CODE ELECTRICAL CODE: 2017 NATIONAL ELECTRICAL CODE FIRE CODE: 2018 INTERNATIONAL FIRE CODE ENERGY CODE: 2018 INTERNATIONAL ENERGY CONSERVATION CODE ACCESSIBILITY CODE: ADA/ANSI A117.1, 2009 ADDITION PROJECT DESCRIPTION: TENANT FINISH REMODEL FOR RETAIL THERAPEUTIC MASSAGE IN STRIP MALL CENTER ZONING: - TYPE OF USE: BUSINESS TYPE OF OCCUPANCY: B-USE TYPE OF CONSTRUCTION: II-B, SPRINKLERED MINIMUM PLUMBING FIXTURE CALCULATION: FIXTURES REQ'D/PROVIDED: MALE - 1WC/1LAV FEMALE - 1WC/1LAV TOTAL SQUARE FOOTAGE: 1600 SF ALLOWABLE OCCUPANT LOAD: BUSINESS USE: 1600 SF @ 150 SF / PERSON = 11 TOTAL INTERIOR OCCUPANT LOAD: = 11 X ROOM ROOM INDICATOR NORTH ARROW EXTERIOR ELEVATION INTERIOR ELEVATION SECTION CALLOUT DETAIL CALLOUT 1 REVISION TAG FINISH TAG DOOR TAG COLUMN GRID REFERENCE 01 1 WINDOW TAG FURNITURE, FIXTURE, EQUIPMENT TAG KEYED NOTE XXX X XXX XXX XXX X X 1 1 1 WORK POINT 01 WALL TAG MILLWORK ELEVATION XXX X 1 1. IN THE CASE OF A STRIP CENTER RENOVATION WHERE APPROXIMATE DIMENSIONS ARE INDICATED (±), THEY SHALL BE CONSIDERED VARIABLE TO ALLOW FOR EXISTING CONDITIONS. ALL OTHER DIMENSIONS SHALL BE CONSIDERED FIXED UNLESS MODIFIED BY A PROPERLY EXECUTED CHANGE ORDER. 2. IT IS THE GC'S RESPONSIBILITY TO MAKE SURE THAT ALL WORK ON THE PREMISES COMPLIES WITH THE CONSTRUCTION GUIDELINES. 3. ANY DISCREPANCIES WHICH SHOULD BECOME APPARENT DURING THE COURSE OF CONSTRUCTION SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. 4. PROPOSED SUBSTITUTIONS SHALL BE SUBMITTED TO THE ARCHITECT. THE PROPOSAL SHALL INCLUDE MANUFACTURER'S CUT SHEETS, COST CHANGE, TIME CHANGE, AND IMPACT ON ANY OTHER TRADES. APPROVAL WILL TAKE THE FORM OF A CHANGE ORDER. 5. ALL CHANGE ORDERS MUST BE SUBMITTED ON AN AIA CHANGE ORDER FORM WITH THE SIGNATURE OF THE CLIENT IN ADDITION TO THE OWNER, CONTRACTOR AND ARCHITECT. SUBMIT CHANGE ORDERS TO CLIENT FOR REVIEW. PROVIDE FULL INFORMATION REQUIRED FOR EVALUATION OF PROPOSED CHANGES, SUBSTANTIATE COSTS AND ADVISE AS TO EFFECT UPON PROJECT SCHEDULE. NO CHANGE ORDER SHALL BE VALID UNTIL SIGNED BY ALL PARTIES. 6. ANY DEVIATION FROM THE CONSTRUCTION GUIDELINES WITHOUT A PROPERLY EXECUTED CHANGE ORDER SHALL BE THE SOLE FINANCIAL RESPONSIBILITY OF THE CONTRACTOR / SUPPLIER. 7. PROVIDE TEMPORARY PROTECTION FOR INSTALLED PRODUCTS AND FINISHES TO PREVENT DAMAGE. ALL ITEMS DAMAGED DURING CONSTRUCTION SHALL BE REPLACED AT NO COST TO THE OWNER. 8. PROJECT (INTERIOR / EXTERIOR) AND ENTIRE SITE IF APPLICABLE MUST BE CLEANED PRIOR TO PUNCH-LIST INSPECTION AND MUST BE LEFT IN OR RESTORED TO CLEAN CONDITION UPON PROJECT COMPLETION. 9. ALL WORK SHALL BE GUARANTEED FOR ONE FULL YEAR FROM DATE OF COMPLETION AND OBTAINING CERTIFICATE OF OCCUPANCY. 10. HVAC, PLUMBING AND ELECTRICAL SYSTEMS HAVE BEEN DESIGNED TO MEET OWNER REQUIREMENTS. EACH SUB-CONTRACTOR SHALL REVIEW THE DRAWINGS AND SHALL IMMEDIATELY ALERT THE ARCHITECT AS TO ANY MODIFICATIONS THAT MAY BE REQUIRED TO COMPLY WITH LOCAL CODES OR EXISTING CONDITIONS. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT ALL WORK DONE ON THE PREMISES SATISFIES ALL GOVERNING AGENCIES. 11. ARCHITECTURAL DRAWINGS ARE TYPICALLY DRAWN TO A REPRESENTATIVE SCALE WHICH IS NOTED ON EACH INDIVIDUAL DRAWING. THIS SCALING CAUSES THE DRAWING TO BE PROPORTIONAL IN ITS REPRESENTATION OF THE WORK. DRAWING REPRODUCTION METHODS ARE NOT CONSIDERED PERFECT, HOWEVER, AND EACH SUCCESSIVE PLOT, COPY OR BLUEPRINT MAY INTRODUCE A SLIGHT ERROR TO THE DRAWINGS. FOR THIS REASON, NO PERSON SHOULD EVER USE A RULER, ARCHITECT'S SCALE OR ENGINEER'S SCALE TO DETERMINE EXACT DIMENSIONS. NUMERICAL DIMENSIONS ARE GIVEN. IF THESE PROVE TO BE INSUFFICIENT OR CONTRADICTORY, THE CONTRACTOR MUST CONTACT THE ARCHITECT FOR FINAL VERIFICATION. WORK BASED UPON SCALED DIMENSIONS MAY BE SUBJECT TO REPAIR OR REPLACEMENT AT THE SOLE FINANCIAL RESPONSIBILITY OF THE CONTRACTOR. 12. LAST DATED REVISION VOIDS ALL PREVIOUS DRAWINGS. 13. REMOVAL OF WINDOWS, WINDOW FRAMES AND CENTER DOOR POST FOR ENTRY OF EQUIPMENT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 14. FIRE SUPPRESSION AND SPRINKLER DRAWINGS TO BE COORDINATED BY GC AND SUBMITTED UNDER SEPARATE PERMIT. R E G I S T E R E D A R C H I T E C T 1 9 5 5 4 J E F F R E Y K . B A K E R S T A T E O F T E X A S DESIGN PARAMETERS, LLC 6373 SILVER STREAM LN FRISCO, TX 75036 PH: 214.784.5014 WWW.DESIGNPARAMETERS.COM START DATE DRAWN BY CHECKED BY PROJECT NO copyright 2021 10/7/2 021 8:14:1 0 AM GN.0 COVER SHEET TENANT FINISH FOR JKB CEB 09.21.2021 ETM2016 ELEMENTS MASSAGE SAN ANTONIO 17038 FIESTA TEXAS DRIVE SUITE 108 SAN ANTONIO, TX 78256 ABBREVIATIONS GENERAL NOTES BUILDING CODE ANALYSIS VICINITY MAP SYMBOL LEGEND 3D VIEW - ILLUSTRATIVE PURPOSES ONLY MECH, ELEC, & PLBG ENGINEER: JOHN P. TINSLEY, P.E. 19600 E PARKER SQ DR, #B - 100 PARKER, CO 80134 PH: 303 - 646 - 4770 ARCHITECT: DESIGN PARAMETERS, LLC 6373 SILVER STREAM LN FRISCO, TX 75036 PH: 214 - 784 - 5014 x 2 CONTACTS SHEET INDEX SHEET # SHEET NAME CURRENT ISSUE DATE GENERAL GN.0 COVER SHEET 10.07.2021 ARCHITECTURAL A0.0 CODE COMPLIANCE 10.07.2021 A2.1 FRAMING & SLAB PLAN 10.07.2021 A2.2 FIXTURE, FURNITURE & EQUIPMENT PLAN 10.07.2021 A2.3 FINISH PLAN 10.07.2021 A2.4 REFLECTED CEILING PLAN 10.07.2021 A2.6 RESTROOM PLANS & ELEVATIONS 10.07.2021 A4.1 INTERIOR ELEVATIONS 10.07.2021 MECHANICAL M0.0 MECHANICAL SPECIFICATIONS 10.07.2021 M1.0 MECHANICAL PLANS 10.07.2021 PLUMBING P0.0 PLUMBING SPECIFICATIONS 10.07.2021 P1.0 WATER PLAN 10.07.2021 ELECTRICAL E0.0 ONELINE, NOTES & SCHEDULES 10.07.2021 E1.0 POWER PLAN 10.07.2021 E2.0 LIGHTING PLAN 10.07.2021 ENERGY EN1.0 ENERGY COMPLIANCE 10.07.2021 EN2.0 ENERGY COMPLIANCE 10.07.2021 E L E M E NT S M A S S A GE B - US E B - US E B - US E V A CA NT V A CA NT V A CA NT NO. DESCRIPTION DATE 1 PERMIT 10.07.2021

Upload: others

Post on 18-Dec-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

ABOVE FINISH FLOORACCESS PANELACCESSIBLEACOUSTICAL TILEADHESIVEADJUSTABLE, ADJACENTAUTHORITY HAVING JURISDICTIONALUMINUMAPPROVED, APPROVALAPPROXIMATEARCHITECTURALASBESTOS CONTAINING MATERIALBEAMBETWEENBLOCKINGBOARDBOTTOM OFBUILDINGCARPETCEILINGCENTER LINECERAMIC TILECLEAR(ANCE)COLUMNCONCRETECONCRETE MASONRY UNITSCONSTRUCTIONCONSTRUCTION MANAGERCONTINUOUSCONTROL JOINTCORNER GUARDCOUNTERFLASHINGCOUNTER SINKDEGREEDEMOLITIONDETAILDIAMETERDIMENSIONDISPENSERDRAWINGSDRINKING FOUNTAINDOWNSPOUTEACHEXTERIOR INSULATION AND

FINISH SYSTEMELECTRIC(AL)EQUALEQUIPMENTELECTRIC WATER COOLERELECTRICAL PANELBOARDEXISTINGEXPANSIONEXPANSION JOINTEXTERIORFINISHFINISHED FLOORFIRE EXTINGUISHERFIRE EXTINGUISHER CABINETFIREPROOF, FIRE PROTECTIONFLOORFLOOR DRAINFLUORESCENTFIBER REINFORCED GYPSUMFIBER REINFORCED PLASTICFIBER RETARDANT TREATEDFOUNDATIONFURNISHGAUGEGENERAL CONTRACTORGLASS, GLAZINGGRAB BARGYPSUM BOARDHARDWAREHARDWOODHEIGHTHIGH DENSITY FIBERBOARDHOLLOW COREHOLLOW METALHOSE BIBHORIZONTALHOURINCANDESCENTINSIDE DIAMETERINSULATIONINTERIORLANDLORD, LEASE LINE

AFFAPACCACTADHADJAHJALAPPDAPPROXARCHACMBMBTWNBLKGBDB.O.BLDGCPTCLGCLCTCLRCOLCONCCMUCONSTCMCONTCJCGCFLGCTSKDEGDEMODTLDIADIMDISPDWGDFDSEAEIFS

ELECEQEQUIPEWCEPEXGEXPEJEXTFINFFFEFECFPFLRFDFLUORFRGFRPFRTFDNFURNGAGCGLGBGYP BDHDWHDWDHTHDFHCHMHBHORHRINCANIDINSULINTLL

LAVATORYLINEARLINEAR FEETLIGHTINGMASONRYMATERIALMAXIMUMMECHANICALMEDIUM DENSITY FIBERBOARDMETALMEZZANINEMANUFACTURERMINIMUMMISCELLANEOUSMASONRY OPENNINGMOUNTEDNOMINALNOT IN CONTRACTNUMBERNOT TO SCALEON CENTEROPENINGOPPOSITEOUTSIDE DIAMTEROWNER FURNISHED/

CONTRACTOR INSTALLEDOWNER FURNISHED/

OWNER INSTALLEDOVERHEADOVERHEAD COILING GRILLEPAINTPANELPARTICLE BOARDPARTITIONPLASTIC LAMINATEPLATEPLUMBINGPLYWOODQUANTITYQUARRY TILERADIUSREFER TOREQUIREDRESILIENTREVISIONRISERROOF DRAINROOMROUGH OPENINGRUBBER BASESCHEDULESECTIONSHEETSIMILARSIMILAR, OPPOSITE HANDSLOTTED WALL BOARDSOLID CORESPECIFICATION(S)SQUARE FEETSTAINLESS STEELSTAIN, SEAL & VARNISHSTANDARDSTEELSTRUCTURALSUSPENDEDTEMPERED, TEMPERATURE,

TEMPORARYTHICK(NESS)TONQUE & GROOVETOP OFTREADTYPICALUNLESS NOTED OTHERWISEVINYL BASEVINYL COMPOSITION TILEVINYL WALL COVERINGVERTICALVERIFY IN FIELDVENT THROUGH ROOFWATER CLOSETWATER HEATERWATERPROOFWITHWITHOUTWOOD

LAVLINLFLTGMASMATLMAXMECHMDFMTLMEZZMFRMINMISCMOMTDNOMNICNO.NTSO.C.OPGOPPODOFCI

OFOI

OHOHCGPTPNLPBDPTNPLAMPLPLBGPLYWDQTYQTRADREFREQRESREVRRDRMRORBSCHEDSECTSHTSIMSIM OPPSWBSCSPEC(S)SFSTSSSVSTDSTLSTRUCTSUSPTEMP

THKT&GT.O.TTYPU.N.O.VBVCTVWCVERTVIFVTRWCWHWPW/W/OWD

LOCAL AUTHORITY:

BUILDING DEPARTMENT:CITY OF SAN ANTONIOBUILDING DEPT1901 SOUTH ALAMO STREETSAN ANTONIO, TX 78204PH: 210.207.1111

BUILDING CODE: 2018 INTERNATIONAL BUILDING CODEMECHANICAL CODE: 2018 INTERNATIONAL MECHANICAL CODEPLUMBING CODE: 2018 INTERNATIONAL PLUMBING CODEELECTRICAL CODE: 2017 NATIONAL ELECTRICAL CODEFIRE CODE: 2018 INTERNATIONAL FIRE CODEENERGY CODE: 2018 INTERNATIONAL ENERGY CONSERVATION CODEACCESSIBILITY CODE: ADA/ANSI A117.1, 2009 ADDITION

PROJECT DESCRIPTION: TENANT FINISH REMODEL FOR RETAIL THERAPEUTIC MASSAGE IN STRIP MALL CENTER

ZONING: -

TYPE OF USE: BUSINESSTYPE OF OCCUPANCY: B-USETYPE OF CONSTRUCTION: II-B, SPRINKLERED

MINIMUM PLUMBING FIXTURE CALCULATION:

FIXTURES REQ'D/PROVIDED: MALE - 1WC/1LAV FEMALE - 1WC/1LAV

TOTAL SQUARE FOOTAGE: 1600 SF

ALLOWABLE OCCUPANT LOAD:BUSINESS USE: 1600 SF @ 150 SF / PERSON = 11

TOTAL INTERIOR OCCUPANT LOAD: = 11

X

ROOM ROOM INDICATORNORTH ARROW

EXTERIOR ELEVATION

INTERIOR ELEVATION

SECTION CALLOUT

DETAIL CALLOUT

1 REVISION TAG

FINISH TAG

DOOR TAG

COLUMN GRID REFERENCE

01

1

WINDOW TAG

FURNITURE,FIXTURE,EQUIPMENT TAG

KEYED NOTE

XXX

X

XXX

XXX

XXX

X

X

1

1

1

WORK POINT

01 WALL TAG

MILLWORK ELEVATIONXXXX

1

1. IN THE CASE OF A STRIP CENTER RENOVATION WHERE APPROXIMATE DIMENSIONS AREINDICATED (±), THEY SHALL BE CONSIDERED VARIABLE TO ALLOW FOR EXISTING CONDITIONS.ALL OTHER DIMENSIONS SHALL BE CONSIDERED FIXED UNLESS MODIFIED BY A PROPERLYEXECUTED CHANGE ORDER.

2. IT IS THE GC'S RESPONSIBILITY TO MAKE SURE THAT ALL WORK ON THE PREMISES COMPLIESWITH THE CONSTRUCTION GUIDELINES.

3. ANY DISCREPANCIES WHICH SHOULD BECOME APPARENT DURING THE COURSE OFCONSTRUCTION SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT.

4. PROPOSED SUBSTITUTIONS SHALL BE SUBMITTED TO THE ARCHITECT. THE PROPOSAL SHALLINCLUDE MANUFACTURER'S CUT SHEETS, COST CHANGE, TIME CHANGE, AND IMPACT ON ANYOTHER TRADES. APPROVAL WILL TAKE THE FORM OF A CHANGE ORDER.

5. ALL CHANGE ORDERS MUST BE SUBMITTED ON AN AIA CHANGE ORDER FORM WITH THESIGNATURE OF THE CLIENT IN ADDITION TO THE OWNER, CONTRACTOR AND ARCHITECT.SUBMIT CHANGE ORDERS TO CLIENT FOR REVIEW. PROVIDE FULL INFORMATION REQUIREDFOR EVALUATION OF PROPOSED CHANGES, SUBSTANTIATE COSTS AND ADVISE AS TO EFFECTUPON PROJECT SCHEDULE. NO CHANGE ORDER SHALL BE VALID UNTIL SIGNED BY ALL PARTIES.

6. ANY DEVIATION FROM THE CONSTRUCTION GUIDELINES WITHOUT A PROPERLY EXECUTEDCHANGE ORDER SHALL BE THE SOLE FINANCIAL RESPONSIBILITY OF THECONTRACTOR / SUPPLIER.

7. PROVIDE TEMPORARY PROTECTION FOR INSTALLED PRODUCTS AND FINISHES TO PREVENTDAMAGE. ALL ITEMS DAMAGED DURING CONSTRUCTION SHALL BE REPLACED AT NO COST TOTHE OWNER.

8. PROJECT (INTERIOR / EXTERIOR) AND ENTIRE SITE IF APPLICABLE MUST BE CLEANED PRIORTO PUNCH-LIST INSPECTION AND MUST BE LEFT IN OR RESTORED TO CLEAN CONDITION UPONPROJECT COMPLETION.

9. ALL WORK SHALL BE GUARANTEED FOR ONE FULL YEAR FROM DATE OF COMPLETION ANDOBTAINING CERTIFICATE OF OCCUPANCY.

10. HVAC, PLUMBING AND ELECTRICAL SYSTEMS HAVE BEEN DESIGNED TO MEET OWNERREQUIREMENTS. EACH SUB-CONTRACTOR SHALL REVIEW THE DRAWINGS AND SHALLIMMEDIATELY ALERT THE ARCHITECT AS TO ANY MODIFICATIONS THAT MAY BE REQUIRED TOCOMPLY WITH LOCAL CODES OR EXISTING CONDITIONS. IT IS THE GENERAL CONTRACTOR'SRESPONSIBILITY TO ENSURE THAT ALL WORK DONE ON THE PREMISES SATISFIES ALLGOVERNING AGENCIES.

11. ARCHITECTURAL DRAWINGS ARE TYPICALLY DRAWN TO A REPRESENTATIVE SCALE WHICH ISNOTED ON EACH INDIVIDUAL DRAWING. THIS SCALING CAUSES THE DRAWING TO BEPROPORTIONAL IN ITS REPRESENTATION OF THE WORK. DRAWING REPRODUCTION METHODSARE NOT CONSIDERED PERFECT, HOWEVER, AND EACH SUCCESSIVE PLOT, COPY ORBLUEPRINT MAY INTRODUCE A SLIGHT ERROR TO THE DRAWINGS. FOR THIS REASON, NOPERSON SHOULD EVER USE A RULER, ARCHITECT'S SCALE OR ENGINEER'S SCALE TODETERMINE EXACT DIMENSIONS. NUMERICAL DIMENSIONS ARE GIVEN. IF THESE PROVE TO BEINSUFFICIENT OR CONTRADICTORY, THE CONTRACTOR MUST CONTACT THE ARCHITECT FORFINAL VERIFICATION. WORK BASED UPON SCALED DIMENSIONS MAY BE SUBJECT TO REPAIROR REPLACEMENT AT THE SOLE FINANCIAL RESPONSIBILITY OF THE CONTRACTOR.

12. LAST DATED REVISION VOIDS ALL PREVIOUS DRAWINGS.13. REMOVAL OF WINDOWS, WINDOW FRAMES AND CENTER DOOR POST FOR ENTRY OF

EQUIPMENT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.14. FIRE SUPPRESSION AND SPRINKLER DRAWINGS TO BE COORDINATED BY GC AND SUBMITTED

UNDER SEPARATE PERMIT.

REG

ISTERED ARCH

ITEC

T

19554

JEFF

REY K . BAKER

S

TA T E OF T EXA

S

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

10/7

/2021

8:1

4:1

0A

M

GN.0COVER SHEET

TE

NA

NT

FIN

ISH

FO

R

JKB

CEB

09.21.2021

ETM2016

ELE

ME

NT

S M

AS

SA

GE

SA

N A

NT

ON

IO17

03

8 F

IES

TA

TE

XA

S D

RIV

ES

UIT

E 1

08

SA

N A

NT

ON

IO,

TX

782

56

ABBREVIATIONSGENERAL NOTES BUILDING CODE ANALYSIS

VICINITY MAP

SYMBOL LEGEND

3D VIEW - ILLUSTRATIVE PURPOSES ONLY

MECH, ELEC, & PLBG ENGINEER:JOHN P. TINSLEY, P.E.19600 E PARKER SQ DR, #B-100PARKER, CO 80134PH: 303-646-4770

ARCHITECT:DESIGN PARAMETERS, LLC6373 SILVER STREAM LNFRISCO, TX 75036PH: 214-784-5014 x 2

CONTACTS

SHEET INDEXSHEET # SHEET NAME CURRENT ISSUE DATE

GENERAL

GN.0 COVER SHEET 10.07.2021

ARCHITECTURAL

A0.0 CODE COMPLIANCE 10.07.2021

A2.1 FRAMING & SLAB PLAN 10.07.2021

A2.2 FIXTURE, FURNITURE & EQUIPMENT PLAN 10.07.2021

A2.3 FINISH PLAN 10.07.2021

A2.4 REFLECTED CEILING PLAN 10.07.2021

A2.6 RESTROOM PLANS & ELEVATIONS 10.07.2021

A4.1 INTERIOR ELEVATIONS 10.07.2021

MECHANICAL

M0.0 MECHANICAL SPECIFICATIONS 10.07.2021

M1.0 MECHANICAL PLANS 10.07.2021

PLUMBING

P0.0 PLUMBING SPECIFICATIONS 10.07.2021

P1.0 WATER PLAN 10.07.2021

ELECTRICAL

E0.0 ONELINE, NOTES & SCHEDULES 10.07.2021

E1.0 POWER PLAN 10.07.2021

E2.0 LIGHTING PLAN 10.07.2021

ENERGY

EN1.0 ENERGY COMPLIANCE 10.07.2021

EN2.0 ENERGY COMPLIANCE 10.07.2021

ELEMENTS MASSAGEB-USE

B-USE

B-USE

VACANT

VACANT

VACANT NO. DESCRIPTION DATE1 PERMIT 10.07.2021

Washer

Dry

er

RE

FR

IG.

DIA

GO

NA

L 7

6'-5"

MA

X E

GR

ES

S 9

5'-11"

THE LETTERS PROVIDED IN THE UPPER LEFT CORNERS CORRESPOND TO THE FIGURES FROM THE 2012 TAS STANDARDS SECTION 404.2.4.1

30"x48"WHEELCHAIR ACCESS

60"-DIAMETER TURNING RADIUS T-SHAPED TURN SPACE

FRONT APPROACHPULL SIDE

FRONT APPROACHPUSH SIDE(IF CLOSER OR LATCH, NOT BOTH)

FRONT APPROACHPUSH SIDE(W/ BOTH CLOSER AND LATCH)

HINGE APPROACHPULL SIDE (V2)

HINGE APPROACHPULL SIDE (V1)

HINGE APPROACHPUSH SIDE(IF CLOSER OR LATCH, NOT BOTH)

HINGE APPROACHPUSH SIDE(W/ BOTH CLOSER AND LATCH)

LATCH APPROACHPULL SIDE(NO CLOSER)

LATCH APPROACHPULL SIDE (W/ CLOSER)

LATCH APPROACHPUSH SIDE(NO CLOSER)

LATCH APPROACHPUSH SIDE(W/ CLOSER)

(a) (b) (c) (d)

(e) (f) (g) (h)

(i)

(j) (k)

ø 60"

30x48T-TURN

x48

x48

12" MIN

x60

18" MIN

x48

22" MIN

x42

22" MIN

x48

24" MIN

x54

24" MIN

x42

24" MIN

x48

24" MIN

36" MIN

x60

42" MIN

x54

60x59

CLEAR TANK TOILET AREA

4' - 6"

5' -

0"

4' -

0"

3' - 0" 4' - 0"

4' -

0"

6' - 0"

5' -

0"

6' - 6"

4' -

6"

3' -

6"

4' - 10"

4' -

0"

4' - 10"

4' -

0"

5' - 0"

4' -

6"

5' - 0"5' - 0"

3' -

6"

4' -

0"

5' - 0"

5' - 0"

3' -

0"

2' -

0"

1' - 0"

3' - 0"

1' - 0"

4' -

0"

2' - 6"

REG

ISTERED ARCH

ITEC

T

19554

JEFF

REY K . BAKER

S

TA T E OF T EXA

S

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

10/7

/2021

8:1

3:5

8A

M

A0.0CODE COMPLIANCE

TE

NA

NT

FIN

ISH

FO

R

JKB

CEB

09.21.2021

ETM2016

ELE

ME

NT

S M

AS

SA

GE

SA

N A

NT

ON

IO17

03

8 F

IES

TA

TE

XA

S D

RIV

ES

UIT

E 1

08

SA

N A

NT

ON

IO,

TX

782

56

1/4" = 1'-0"2

EGRESS AND CODE COMPLIANCE PLAN1/4" = 1'-0"

1TAS ACCESSIBILITY CLEARANCES

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

TYPE D2

HOLLOW METAL OR WOODDOOR AND FRAME

TYPE D3

STOREFRONT DOOR

TYPE D4

PAIRSTOREFRONT DOOR

TE

MP

ER

ED

TE

MP

ER

ED

TE

MP

ER

ED

TYPE D1

7/16"Dx1/4"W RABBET3-SIDES ON EXTERIOR

FACE OF INSWING

PARTITION LENGTH

MINIMUM MAXIMUM

0' - 0" 12' - 0"

12' - 0" 18' - 0"

18' - 0" 24' - 0"

30' - 0"

NUMBER OF BRACES REQUIRED

0

1

2

3

ADD ONE BRACE PER EACH ADDITIONAL 6'-0" OF PARTITION LENGTH.PROVIDE LATERAL BRACING AT UNSUPPORTED PARTITION ENDS.PROVIDE LATERAL BRACING FOR ALL PARTITIONS WHICH DO NOT EXTEND TO STRUCTURE.

FULL HEIGHT WALL

PARTIAL HEIGHT WALL

EXISTING WALL

FULL HEIGHT WALL WITH SOUND BATTS TO MEET FLAME SPREAD<25 & SMOKE INDEX<450

A2.6

2

W7

W2

W2W2

W1

W1

W5

W5

W5

W5

W3

W1

W1

W1

W1

W1

W1

W1

W2.1

W3

W2.1

W1

W1

W1

W1

W3

W4

11

' -

8 1

/2"

7 1

/4"

11

' - 1

0 3

/4"

4 7

/8"

11

' - 1

1 3

/8"

4 7

/8"

12

' -

0"

4 7

/8"

12

' -

0"

7 1

/4"

11

' -

7"

14

' -

1"

4 7

/8"

7' -

6 3

/8"

4 1

/4"

7 1

/4"

12

' -

0"

4 7

/8"

12

' -

0"

4 7

/8"

12

' -

0"

7 1

/4"

2' -

2 1

/2"

8' -

11

"

4 1

/4"

1' -

8 1

/4"

6' - 8 3/4"

3' -

3 1

/4"

1

2

3

4

5

6

7

8

9

10

11

2' - 0"

CENTERLINES

21' - 4"

TY

P C

L

2' -

1"

W5

REG

ISTERED ARCH

ITEC

T

19554

JEFF

REY K . BAKER

S

TA T E OF T EXA

S

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

10/7

/2021

8:2

0:0

1A

M

A2.1FRAMING & SLAB PLAN

TE

NA

NT

FIN

ISH

FO

R

JKB

CEB

09.21.2021

ETM2016

ELE

ME

NT

S M

AS

SA

GE

SA

N A

NT

ON

IO17

03

8 F

IES

TA

TE

XA

S D

RIV

ES

UIT

E 1

08

SA

N A

NT

ON

IO,

TX

782

56

KEYED NOTES

SHEET NOTESDOOR TYPE LEGEND

FRAME TYPES

HARDWARE SETS

HARDWARE NOTES

LATERAL BRACING

DOOR FRAME

DOOR NO. DOOR LOCATION DOOR SIZE TYPE FINISH HARDWARE SET CLOSER TYPE FINISH

1 ENTRANCE 3'-0" x 7'-0" D4-EXIST H1 YES F3-EXIST ALUM

2 HALLWAY 36" x 96" D1 MASONITE PREFIN ARCH WHITE BIRCH -ROLLED OATS

H2 YES F4 N/A

3 MASSAGE ROOM 36" x 84" PUBLIC D2 MASONITE PREFIN ARCH WHITE BIRCH -ROLLED OATS

H3 NO F1 PREFIN

4 MASSAGE ROOM 36" x 84" PUBLIC D2 MASONITE PREFIN ARCH WHITE BIRCH -ROLLED OATS

H3 NO F1 PREFIN

5 MASSAGE ROOM 36" x 84" PUBLIC D2 MASONITE PREFIN ARCH WHITE BIRCH -ROLLED OATS

H3 NO F1 PREFIN

6 MASSAGE ROOM 36" x 84" PUBLIC D2 MASONITE PREFIN ARCH WHITE BIRCH -ROLLED OATS

H3 NO F1 PREFIN

7 MASSAGE ROOM 36" x 84" PUBLIC D2 MASONITE PREFIN ARCH WHITE BIRCH -ROLLED OATS

H3 NO F1 PREFIN

8 MASSAGE ROOM 36" x 84" PUBLIC D2 MASONITE PREFIN ARCH WHITE BIRCH -ROLLED OATS

H3 NO F1 PREFIN

9 MASSAGE ROOM 36" x 84" PUBLIC D2 MASONITE PREFIN ARCH WHITE BIRCH -ROLLED OATS

H3 NO F1 PREFIN

10 RESTROOM 36" x 84" RESTROOM D2 MASONITE PREFIN ARCH WHITE BIRCH -ROLLED OATS

H4 NO F1 PREFIN

11 BREAK ROOM 36" x 84" STAFF D2 MASONITE PREFIN ARCH WHITE BIRCH -ROLLED OATS

H5 YES F1 PREFIN

DOOR SCHEDULE

TYPE WIDTH DESCRIPTION HEIGHT GYP BD REQUIREMENTS

W1 4 7/8" 3 5/8" METAL STUD TO DECK TO GYP BD CEILING, 6" ABOVE SUSPENDED CEILING OR TO OPEN DECK, TILEBACKER BOARD IN LIEU OF GWB IN RESTROOMS

W2 7 1/4" 3-5/8" STAGGERED METAL STUDSIN 6" METAL TRACK

TO DECK TO GYP BD CEILING, 6" ABOVE SUSPENDED CEILING OR TO OPEN DECK

W2.1 7 1/4" 3-5/8" STAGGERED METAL STUDSIN 6" METAL TRACK

6" ABV CLG TO GYP BD CEILING, 6" ABOVE SUSPENDED CEILING OR TO OPEN DECK

W3 7 1/4" 6" METAL STUDS - 1HR UL U419 TO DECK TO DECK PER UL U419

W4 6 5/8" 6" METAL STUD 6" ABV CLG TO GYP BD CEILING, 6" ABOVE SUSPENDED CEILING OR TO OPEN DECK

W5 4 1/4" 3 5/8" METAL STUD FURRING 18" AFF TO 8'-6" AFF TO GYP BD CEILING, 6" ABOVE SUSPENDED CEILING OR TO OPEN DECK

W7 4 1/4" 3 5/8" METAL STUD FURRING TO DECK TO GYP BD CEILING, 6" ABOVE SUSPENDED CEILING OR TO OPEN DECK

WALL TYPE SCHEDULE WALL LEGEND1. DIMENSIONS SHOWN ARE TO FACE OF GYPSUM WALLBOARD OF NEW AND

EXISTING WALLS UNLESS OTHERWISE NOTED.2. FLOOR DRAINS (REFER TO PLUMBING SHEETS) SHALL BE SET TO BE FLUSH

WITH TOP OF FINISH FLOOR. UNLESS OTHERWISE NOTED.3. FLOORING CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL FLOOR PREP

NECESSARY FOR ALL FLOORING.4. ALL SEALANTS ARE TO BE CLEAR SILICONE UNLESS OTHERWISE NOTED.5. ALL METAL STUD FRAMING IS 20 GAUGE AT 16" O.C. UNLESS NOTED

OTHERWISE. GYPSUM WALLBOARD TO BE 5/8", FIRE CODE TYPE "X",TAPERED EDGE, UNLESS OTHERWISE SPECIFIED IN THESE DOCUMENTS. INSTALL PER MANUFACTURER'S SPECIFICATIONS.

6. GYPSUM WALLBOARD ON ALL BULKHEADS TO EXTEND 6" ABOVE ADJACENT SUSPENDED GRID CEILING.

7. RESTORE OR PROVIDE NEW UL LISTED INSULATION MATERIALS IN DEMISING WALL AFTER INSTALLING TENANT UTILITIES.

8. GC TO COORDINATE WITH FIRE MARSHAL TO DETERMINE FINAL LOCATION OF FIRE EXTINGUISHERS.

9. G.C. TO REFERENCE CONTRACTORS SHOP DRAWINGS FOR INSTALLATION INSTRUCTIONS FOR ALL FIXTURES, BASE CABINETS, AND COUNTERTOPS. G.C. TO COORDINATE WITH FIXTURE CONTRACTOR TO ENSURE PROPER FIT OF ALL COMPONENTS.

10. ALL WOOD BLOCKING, FURRING, & FRAMING SHALL BE FIRE RETARDANT TREATED IN ACCORDANCE WITH AWPA STANDARDS.

11. GENERAL CONTRACTOR TO CUT AND PROVIDE HOLES THROUGH CEILINGS, ROOF'S, WALLS AND FLOORS FOR DUCTS, ETC., IN ACCORDANCE WITH LOCAL FIRE CODE AND AS SPECIFIED. GC ALSO TO PROVIDE ALL DUCT FIRE SEPARATIONS, ENCLOSURES, WRAPPINGS, ETC., AS MAY BE REQUIRED BY LOCAL BUILDING AND FIRE CODES.

12. SLEEVES TO BE PROVIDED BY GENERAL CONTRACTOR IN ALL WALLS, FLOOR AND CEILINGS FOR ALL LINES (DRAIN, REFRIGERATION, ETC.) TO PASS THROUGH AND RESEAL AFTER LINES ARE RUN. PROVIDE ESCUTCHEON PLATES WHERE APPROPRIATE.

13. IT IS THE GC'S RESPONSIBILITY TO DO A SITE VISIT AND VERIFY ALL EXISTING FRAMING/DRYWALL PER THE PLANS. IF EXISTING CONDITIONS DIFFER FROM THE PLANS, IT IS REQUIRED TO MAKE THE OWNER AWARE OF THE SITUATION SO AN ADDENDUM CAN BE ISSUED. IF THE OWNER IS NOT MADE AWARE OF PRIOR TO BID ACCEPTANCE AND THERE IS MISSING FRAMING/DRYWALL, A CHANGE ORDER FOR THIS WORK WILL NOT BE ACCEPTED.

14. LEVEL 4 FINISH THROUGHOUT

1/4" = 1'-0"1

FRAMING & SLAB PLAN

NOTE: GC TO ENSURE EXISTING HARDWARE COMPLIES WITH LOCAL CODES, SUPPLEMENT HARDWARE AS REQUIRED

F1: TIMELY 'S' - SC101 BROWNTONEF2: 2" WELDED METAL FRAME WITH 1/2" STOPSF3: ALUMINUM STOREFRONTF4: EZY JAMB SINGLE RABBET - VERIFY HANDING

H1: ENTRY DOORS: G.C. TO VERIFY EXISTING CONDITION TO BE LIKE NEW. REPLACE AS NEEDED FOR MECHANISM AND FINISH; HANDICAP ACCESSIBLE COMPLIANT PUSH\PULL HARDWARE; EXIT DOORS TO REMAIN UNLOCKED DURING OPERATING HOURS SIGN SHALL BE POSTED ON EGRESS SIDE OF DOOR STATING "THIS DOOR TO REMAIN UNLOCKED DURING OCCUPANCY." SIGN TO HAVE 1" LETTERS ON CONTRASTING BACKGROUND; ALL EXISTING EXTERIOR EXIT DOORS SHALL OPEN OUTWARD, BE SELF CLOSING AND FIT TIGHTLY; MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED; AUTOMATIC FLUSH BOLTS ARE PERMITTED

H2: HALLWAY DOOR: 2 PAIR HINGES HAGER BB1279 4.5x4.5 US26D; (1) CLOSER ASSA ABLOY DC700G-CM, SOFT CLOSE, 90 DEGREE LIMIT STAINLESS STEEL; (6) SILENCERS HAGER 307D GREY; (2) VERTICAL PULL HAGER 915P 36" US26D -NO LATCH

H3: STANDARD ROOM DOOR: 1-1/2 PAIR HINGES HAGER BB1279 4.5x4.5 US26D; (6) SILENCERS HAGER 307D GREY; (1) PASSAGE LEVER HAGER 3510 AUGUST US26D; (1) DOOR STOP HAGER 248F

H4: RESTROOM DOOR: 1-1/2 PAIR HINGES HAGER BB1279 4.5x4.5 US26D; (1) CLOSER ASSA ABLOY DC700G-CM, SOFT CLOSE, 90 DEGREE LIMIT STAINLESS STEEL; (6) SILENCERS HAGER 307D GREY; (1) PRIVACY LEVER HAGER 3540 AUGUST US26D; (1) WALL STOP HAGER 232W US32D

H5: STAFF AREA DOOR: 1-1/2 PAIR HINGES HAGER BB1279 4.5x4.5 US26D; (1) CLOSER ASSA ABLOY DC700G-CM, SOFT CLOSE, 90 DEGREE LIMIT STAINLESS STEEL; (6) SILENCERS HAGER 307D GREY; (1) BTB DUMMY LEVER HAGER 3527 AUGUST US26D - NO LATCH ; (1) DOOR STOP HAGER 248F

H6: OFFICE DOOR: 1-1/2 PAIR HINGES HAGER BB1279 4.5x4.5 US26D; (1) OVERHEAD HOLD OPEN HAGER 6000, SOFT CLOSE, 90 DEGREE LIMIT STAINLESS STEEL; (6) SILENCERS HAGER 307D GREY; (1) OFFICE LEVER HAGER 3550 AUGUST US26D; (1) DOOR STOP HAGER 248F

H7: EXISTING EGRESS DOOR: G.C. TO VERIFY EXISTING CONDITION TO BE LIKE NEW. REPLACE AS NEEDED FOR MECHANISM AND FINISH; HANDICAP ACCESSIBLE COMPLIANT

H8: CLOSET DOOR: 1-1/2 PAIR HINGES HAGER BB1279 4.5x4.5 US26D; (6) SILENCERS HAGER 307D GREY; (1) DUMMY LEVER HAGER 3527 AUGUST US26D - NO LATCH

• ALL HARDWARE TO BE APPROVED FOR ADA ACCESSIBILITY.

• PROVIDE A FACTORY INSTALLED SMOKE GASKET IF FRAME IS IN A RATED PARTITION.

• FINISHES FOR HARDWARE AT INTERIOR OF STORE SHALL BE BRUSHED CHROME. FINISHES AT STOREFRONT SHALL MATCH EXISTING AND NEW STOREFRONT.

• ALL DOOR HARDWARE SHALL BE LEVER OR PUSH TYPE, MOUNTED 30" TO 44" ABOVE THE FLOOR AND BE OPERABLE WITH A MAX EFFORT OF 5 LBS. FOR EXTERIOR DOORS AND 5 LBS. FOR INTERIOR DOORS, AND 15 LBS. AT FIRE DOORS.

• ALL EXIT DOORS MUST BE OPERABLE FROM INSIDE WITHOUT THE USE OF A KEY, THUMB TURN OR SPECIAL KNOWLEDGE OR EFFORT.

• REAR EXIT DOOR SHALL BE 20 MIN FIRE RATED (UNLESS OTHERWISE (NOTED) WITH SMOKE AND DRAFT GASKET ASSEMBLY AND SELF CLOSER. RATING LABEL TO REMAIN VISIBLE ON HINGED EDGE OF DOOR.

• METAL DOORS AND FRAMES ARE TO BE PAINTED WITH (1) COAT OIL BASE PRIMER AND AS MANY COATS AS NECESSARY OF OIL BASE PAINT TO ACHIEVE A SMOOTH, COMPLETE FINISH.

• PAINT AND LABEL EXTERIOR SIDE OF REAR EXIT DOOR PER LANDLORD CRITERIA.

• GC TO ADD / MODIFY HARDWARE ON EXISTING EXTERIOR DOORS TO PROVIDE COMPLETE HARDWARE SETS NOTED.

EXISTING WALL W/RIGID INSULATION. ADD 5/8" GYP TO DECK. FINISH ALL EXISTING & NEW WALLS TO LEVEL 4 FINISH, TYP

EXISTING TENANT DEMISING WALL TO REMAIN. ADD LAYER OF 5/8" GOLDBOND SOUNDBREAK XP OVER EXISTING STUDS TO DECK. INSULATE PER PLAN

1 ELECTRICAL PANEL, RE: ELEC

2

EXIT DOORS SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT THESPECIAL USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT PER IBC 1008.1.8.MANUALLY OPERATED SURFACE-BOLTS AND FLUSH-BOLTS ARE PROHIBITED

PROVIDE SIGN "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING ISOCCUPIED" PER IBC 1010.1.9.3

3

4

5

6

7

ADD 1 LAYER OF 5/8" GOLD BOND SOUNBREAK XP TO DECK IN LIEU OF 5/8" GYP BOARD ON THIS SIDE OF WALL

8

9

MOP SINK AND WATER HEATER. RE: PLUMBING10

FLOOR OUTLET \ DATA, CENTER IN ROOM, U.N.O., RE: ELECTRICAL

11 POWER AND DATA TO DESK, RE: ELEC, RE: MILLWORK SHOPS

GC TO PROVIDE ALTERNATE PRICE TO PLACE SOUND BATT INSUL ALL MASSAGE ROOM WALLS, BETWEEN ROOMS & AT HALLWAYS

1

2

2

2

2

3 4

5

5

5

5

5

5

5

6

7

7

7

7

6

8

8

8

8

10

11

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

mikel
Rectangle
mikel
Text Box
6" ABV CLG

Washer

Dry

er

RE

FR

IG.

F7F7

M-6

M-11

F1

M-4

M-1 F5

F5

F5

M-2

F7

M-10

M-13

F10

AP

M-4

M-4

M-4

M-4

M-4

M-4

M-7.B30M-7

F7F7 F7

F8

M-10

F10

M-10

F10

M-10

F10

M-10

F10

M-10

F10

M-10

F10

F1

F1

F1

F1

F1

F1

REG

ISTERED ARCH

ITEC

T

19554

JEFF

REY K . BAKER

S

TA T E OF T EXA

S

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

10/7

/2021

8:1

4:0

0A

M

A2.2FIXTURE, FURNITURE &

EQUIPMENT PLAN

TE

NA

NT

FIN

ISH

FO

R

JKB

CEB

09.21.2021

ETM2016

ELE

ME

NT

S M

AS

SA

GE

SA

N A

NT

ON

IO17

03

8 F

IES

TA

TE

XA

S D

RIV

ES

UIT

E 1

08

SA

N A

NT

ON

IO,

TX

782

56

SHEET NOTES

KEYED NOTES

MILLWORK SCHEDULE

TYPE 3C QTY DESCRIPTION

RESPONSIBILITY

O.F. C.F. O.I. C.I.

AP EL010 1 ACRYLIC PANEL VIA 3C ●

F8 EL008B 3 NON-METAL LOCKER ● ●

M-1 EL016A 1 RECEPTION DESK VIA 3C ●

M-2 EL018B 1 RECEPTION BACK COUNTER VIA 3C ●

M-4 EL017E 7 MASSAGE ROOM COUNTER\CABINET AND SHELVES VIA 3C ●

M-6 EL044 1 SOAP NOTES COUNTER VIA 3C ●

M-6.W30 EL049A 1 W3018 SOAP NOTES CABINET VIA 3C ●

M-6.W36 EL046A 3 W3618 SOAP NOTES CABINET VIA 3C ●

M-7 EL042A 1 BREAK ROOM KITCHENETTE COUNTER VIA 3C ●

M-7.5 1 WFILLER FOR UPPER CABS VIA 3C ●

M-7.B30 EL037A 2 B3032.5 ADA BASE CABINET VIA 3C ●

M-7.SB EL040A 3 36W ADA SINK BASE W/SKIRT PANEL VIA 3C ●

M-7.U36 EL039A 4 W3618 UPPER CABINET VIA 3C ●

M-7.W30 EL038A 5 W3036 WALL CABINET VIA 3C ●

M-7.W36 EL050A 1 W3636 WALL CABINET VIA 3C ●

M-7W24 EL038A 1 W2436 WALL CABINET VIA 3C ●

M-10 7 24"x4" MASSAGE ROOM SHELF AND 24"x36" MIRROR ● ●

M-11 EL052A 1 STAFF ADA HANDSINK COUNTER VIA 3C ●

M-13 EL044A 1 STAFF BREAK COUNTER VIA 3C ●

FURNITURE SCHEDULE

1. ALL EQUIPMENT SHALL BE N.S.F. APPROVED AND SHALL BE INSTALLED PER LOCAL HEALTH DEPARTMENT REQUIREMENTS.

2. VERIFY ALL DIMENSIONS WITH EQUIPMENT SUPPLIER WHERE ITEMS ARE TO BE BUILT-IN AND / OR CUTOUTS ARE REQUIRED FOR INSTALLATION.

3. ALL EQUIPMENT INDICATED ON THE EQUIPMENT SCHEDULE SHALL BE DELIVERED AND INSTALLED BY THE EQUIPMENT SUPPLIER UNLESS OTHERWISE NOTED. FINAL HOOK-UP IS BY THE GC.

4. NO PIPING, WIRE, CONDUIT, ETC. SHALL BE EXPOSED MORE THAN THE MINIMUM REQUIRED TO INSTALL PROPER FITTINGS AND ESCUTCHEON PLATES.

5. IT IS THE GC'S RESPONSIBILITY TO FIRMLY ANCHOR ANY EQUIPMENT WHICH IS REQUIRED TO BE FIXED. CAULK AND SEAL TO WALLS AND FLOOR AS REQUIRED.

6. GC TO ASSEMBLE AND INSTALL TABLES AS REQUIRED PER MANUFACTURER'S SPECIFICATIONS.

7. DIMENSIONS SHOWN AT PLUMBING FIXTURES ARE TO CENTERLINE.8. COORDINATE LOCATIONS AND QUANTITIES OF SINKS, FLOOR SINKS, FLOOR

DRAINS, PIPE PENETRATIONS, ETC., MEP DRAWINGS. PROVIDE 1/8" PER FOOT SLOPE TO ALL FLOOR DRAINS.

9. PROVIDE PLYWOOD REINFORCING AND WOOD BLOCKING BEHIND ALL WALL MOUNTED SINKS AND ALL WALL MOUNTED TOILET ROOM ACCESSORIES.

10. CONCRETE FLOORS SHALL BE FINISHED SMOOTH AND ALL EXPANSION JOINTS OR CRACKS SHALL BE PROPERLY FILLED, NO OPEN CRACKS OR OPEN EXPANSION JOINTS ALLOWED.

11. VERIFY FINAL EQUIPMENT LOCATIONS AND DIMENSIONS WITH OWNER'S REP., RELATED SUBCONTRACTORS AND/OR EQUIPMENT SUPPLIER PRIOR TO FABRICATING OR INSTALLING ANY MILLWORK.

12. REFER TO FINISH LEGEND FOR INDICATION OF TYPES, COLORS, ETC., OF ALL CERAMIC AND QUARRY TILE. REFER TO FINISH FLOOR PLAN AND ROOM ELEVATIONS FOR EXTENT OF FINISHES.

13. ALL SIGNAGE SHALL COMPLY WITH LOCAL BUILDING CODE AND WITH THE APPLICABLE ANSI PROVISIONS.

14. APPLY A CLEAN, SMOOTH RAISED BEAD OF SILICONE CAULK ON ALL GAPS OR SEAMS BETWEEN IMMOVABLE EQUIPMENT AND WALLS. SEAL SPACES AROUND PIPES OR CONDUIT AT ALL WALL PENETRATIONS.

15. PROVIDE ELASTOMERIC WATER-RESISTANT SEALANT AT ALL FLOOR PENETRATIONS AND JOINTS AT WET AREAS.

16. ALL INTERIOR PUBLIC AREA LIGHTING (EXCEPT FLUORESCENT) SHALL BE DIMMED WITH SLIDE DIMMERS (LUTRON OR EQUAL).

17. ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ALL BULBS AND WARRANT FOR 30 DAYS AFTER TURNOVER.

18. ELECTRICAL CONTRACTOR SHALL BE REQUIRED TO ASSEMBLE LIGHT FIXTURES, REGARDLESS OF WHO SUPPLIES THEM.

19. ELECTRICIAN SHALL PROVIDE DEDICATED POWER TO EXTERIOR SIGNS AND MAKE FINAL ELECTRICAL CONNECTION WHEN SIGNS ARE INSTALLED. NO OTHER LIGHTS OR MOTORS MAY BE ON THE SAME CIRCUIT BREAKER OR MOUNTED NEAR TRANSFORMERS.

20. INDIVIDUAL FIXED OR OPERABLE PANELS THAT MEET ALL OF THE FOLLOWING CRITERIA SHALL HAVE TEMPERED GLASS:

I) EXPOSED AREA OF AN INDIVIDUAL PANE IS GREATER THAN 9 SQUARE FEET, AND:

II) EXPOSED BOTTOM EDGE IS LESS THAN 18 INCHES ABOVE THE FLOOR, AND:

III) EXPOSED TOP EDGE IS GREATER THAN 36 INCHES ABOVE THE FLOOR, AND:

IV) ONE OR MORE WALKING SURFACES ARE WITHIN 36 INCHES HORIZONTALLY OF THE PLANE OF THE GLAZING.

22. INTERIOR FINISHES TO MEET ASTM E84 OR UL723 CLASS B FLAME SPREAD INDEX 26-75 & SMOKE DEVELOPED INDEX 0-450

1/4" = 1'-0"1

FF&E PLAN

TYPE QTY DESCRIPTION

RESPONSIBILITY

O.F. C.F. O.I. C.I.

F1 7 MASSAGE TABLE VIA WAVE ●

F5 3 DESK CHAIR ● ●

F7 6 BREAK ROOM CHAIR ● ●

F10 7 MASSAGE ROOM STOOL VIA WAVE ●

MENU 1 MENU OF SERVICES ● ●

TV1 1 TV MONITOR ● ●

O.F. - OWNER FURNISHED

C.F. - CONTRACTOR FURNISHEDO.I. - OWNER INSTALLED

C.I. - CONTRACTOR INSTALLED

1ANSI/ADA COMPLIANT TRANSACTION COUNTER DESK. SEE OWNER/CORPORATE SPEC

2

3MILLWORK/CASEWORK BY OWNER VIA 3C. REQUIRED TO PROVIDE SHOP DRAWINGS FOR OWNER APPROVAL PRIOR TO FABRICATION, TYP. INSTALLED BY G.C.

4

VINYL DECALS/GRAPHICS BY OWNER, INSTALLED BY G.C.

5

6

PROVIDE ANSI/ADA COMPLIANT RESTROOM SIGNAGE - CHARCOAL GRAY

NEW HI-LO ADA\ANSI COMPLIANT DRINKING FOUNTAIN. RE: PLUMBING

ANSI/ADA COMPLIANT COUNTER/SKIRT BY OWNER

7

848"x96" ACYLIC PANEL (AP-1) MOUNTED WITH CABLE HARDWARE SYSTEM, RE: FINISH SCHEDULE. PROVIDED BY OWNER VIA 3C. INSTALLED BY G.C.

9 GC TO PROVIDE PRICE TO INSTALL OWNERS ARTWORK PACKAGE

10 OWNER PROVIDED/INSTALLED FURNITURE

1

2

3

3

3

3

3

3

3

3

3 3

3

5

4

8

9

10

10 10

10

10

1010

10

10

1010

10

10

10

10

10

1010

3

10

10 10

10

10

3

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

VV

V

VV

VV

TC

C-1

T-1

RF-1

C-1

C-1

C-1

C-1

RF-2

C-1

C-1

RF-1

A4.1

1

A4.1 5

A4.19

A2.6

1

A4.1 13

A4.11714

16

15

18

4

5 3

11

10

12

4

3

2

6

7

8

REG

ISTERED ARCH

ITEC

T

19554

JEFF

REY K . BAKER

S

TA T E OF T EXA

S

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

10/7

/2021

8:1

4:0

1A

M

A2.3FINISH PLAN

TE

NA

NT

FIN

ISH

FO

R

JKB

CEB

09.21.2021

ETM2016

ELE

ME

NT

S M

AS

SA

GE

SA

N A

NT

ON

IO17

03

8 F

IES

TA

TE

XA

S D

RIV

ES

UIT

E 1

08

SA

N A

NT

ON

IO,

TX

782

56

1. FLOORING CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL FLOOR PREP NECESSARY FOR ALL FLOORING.

2. REFER TO INTERIOR ELEVATIONS FOR CLARIFICATIONS.3. RETURN ALL FINISHES TO WINDOW / DOOR FRAMES.4. CONTINUE NEW FLOORING UNDERNEATH ALL SEATING.5. ALL CEMENTITIOUS / SANDED GROUT TO RECEIVE "AQUA MIX SEALERS CHOICE

GOLD" SEALANT.6. ALL SEALANTS ARE TO BE CLEAR SILICONE UNLESS OTHERWISE NOTED.7. ALL HORIZONTAL SEAMS ARE TO BE SEALED (I.E. COUNTERTOPS, TILE AND

STATIONARY FIXTURES, ETC.). USE CLEAR CAULK.

SHEET NOTES

KEYED NOTES

FINISH SCHEDULENOTE: RE: A4.1 FOR WALL FINISHES. FINISHES TRANSITION AT INSIDE CORNERS UNLESS NOTED OTHERWISE

TAG DESCRIPTION MANUFACTURER & COLOR, PATTERN, ETC. FINISH NOTES

CASEWORK

PL-1 PLASTIC LAMINATE WILSONART D427-60 "LINEN" SOLICOR MATTE

PL-2 PLASTIC LAMINATE WILSONART - 7937-38 "RIVER CHERRY" FINE VELVET

PL-3 PLASTIC LAMINATE NEVAMAR - WZ0049-V "CREMA"

PL-4 PLASTIC LAMINATE WILSONART - 7938-38 "NEW AGE OAK"

PL-5 PLASTIC LAMINATE WILSONART - 1849K-35 "LUNA FROST" HD LAMINATE

SS-1 SOLID SURFACE LG - HI-MACS 1/2" -GT910 "EGG WHITE

FLOORING

C-1 CARPET TILE J&J FLOORING - KINETEX "STRATA" 1848 FELDSPAR CONTACT ANDREW FINDLAY [email protected] PEM01

RF-1 "CONCRETE" TILE MANNINGTON SPACIA SS5S3071 - "GALLERY CONCRETE" 12x18x2.5MM CONTACT PENNY FISCHER [email protected] ELEMENTSMASSAGE P-385734 NATIONAL ACCOUNT SA CONTRACT #40001132

RF-2 CLASSIC WALNUT PLANKS MANNINGTON AMTICO AROW7610 6x36 2.5MM BEVELED EDGE CONTACT PENNY FISCHER [email protected] ELEMENTSMASSAGE P-385734 NATIONAL ACCOUNT SA CONTRACT #40001132

T-1 FLOOR TILE CROSSVILLE - NEST "JOYOUS OLIVE" 6"x36" MATTE GROUT: LATICRETE #56 "DESERT KHAKI"; CONTACT GINA [email protected]

T-1A FLOOR TILE TRIM CROSSVILLE - NEST "JOYOUS OLIVE" 3"x15" UNPOLISHED GROUT: LATICRETE #56 "DESERT KHAKI"; CONTACT GINA [email protected]

PAINTS & STAINS

P-1 WHITE INTERIOR LATEX BENJAMIN MOORE - PM-3 "DECORATOR'S WHITE" EGGSHELL TYP.

P-2 CEILING INTERIOR LATEX SHERWIN WILLIAMS - SW7757 "HIGH-REFLECTIVE WHITE" FLAT

P-3 ACCENT WALL PAINT BENJAMIN MOORE - 2125-30"GRAY SHOWER" EGGSHELL ACCENT NICHE

P-4 ACCENT WALL PAINT SHERWIN WILLIAMS - SW7018 "DOVETAIL" EGGSHELL ACCENT CORRIDOR

P-5 ACCENT WALL PAINT SHERWIN WILLIAMS - PROMAR 200 ZERO VOC (OZ W1-6/L1-0/R3-0/Y1-2) (32W1-13/L1-31/R3-16/Y1-10) (64 W1-0/L1-0/R3-0/Y1-0) (128W1-0/L1-0/R3-1/Y1-0)

EGGSHELL ACCENT CANOPY - TO MATCH PANTONE 557C

P-6 ACCENT WALL PAINT SHERWIN WILLIAMS - SW7035 "AESTHETIC WHITE" EGGSHELL RESTROOMS

P-7 ACCENT WALL PAINT SHERWIN WILLIAMS - SW7044 "AMAZING GRAY" EGGSHELL ALTERNATE MASSAGE ROOM WALL

ST-1 WOOD STAIN MINWAX CLASSIC GRAY MW271

WALL BASE

RB-1 RUBBER BASE TARKETT - 469 "MYSTIFY" 4 INCH

RB-2 RUBBER BASE TARKETT - 29 "MOON ROCK" 4 INCH

RB-3 RUBBER BASE TARKETT - 283 "TOAST" 4 INCH

WALL COVERING

STS STAINLESS STEEL

WALL FINISHES

AP-1 ACRYLIC DIVIDER 3FORM - 3/8" VARIA ECORESIN "BRANCH COLOR" - VELLUM F04 (ONE SIDE) S.O. 483995.2 4x8 PANEL, PRINT FACING DESK, CABLE SYSTEM AND ALL HARDWAREPROVIDED BY OWNER VIA 3C

AP-2 ACRYLIC ACCENT 3FORM - CHROMA "ALOE G60+OAT N23+REEF B18+AVALANCHE D01" -VELLUM F04 F&B

S.O. 485697.3 PROVIDED BY OWNER VIA 3C

FRP FRP MARLITE P-100 WHITE PEBBLE MARLITE INSIDE CORNER GUARDS, USE MODEL #M350FP / 3/4" (WHITE).

T-2 WALL TILE OLYMPIA TILE & STONE - SHADEBRICK "LIGHT" 3"x12" GLOSS GROUT: LATICRETE #44 "BRIGHT WHITE"; CONTACT ASHLEY [email protected]

WC-1 WALL COVERING -CORRIDOR

TRIKES - "RIVOLI" - LV-RI-04 FAUVE 54" WIDE - CONTACT MICHELE SILVA CUSTOMER CODE MS-102418-01

WC-2 WALL COVERING - ROOMS MDC - "TAPA" - TFC1286/4766 PEPPER 54" WIDE - NATIONAL PRICING CODE:ALPHA7552CONTACT KEITH DRUCKS [email protected] 847-437-4017

1/4" = 1'-0"1

FINISH PLAN

ELECTRICAL PANELS, RE: ELECTRICAL1

MOP SINK, RE: PLUMBING2

PROVIDE TRANSITION STRIPS AT ALL FINISH CHANGES:TILE TO LVT: SCHLUTER RENO-UCARPET TO LVT, LVT TO LVT: JOHNSONITE CTA-XX-N, COLOR 29 "MOONROCK"

3

1

2

3

3

3

3

3

3

3

3

3

3

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

mikel
Line
mikel
Typewritten Text
[email protected] - 732-413-5099
mikel
Line
mikel
Line
mikel
Typewritten Text
[email protected] - 908-510-1107

TV

F1RECESSED CAN

REFER TO ELECTRICAL LIGHTING SCHEDULES FOR SPECIFICATIONS

F92x2 TROFFERGRID CEILINGS

EMEMERGENCY LIGHT

XEMEXIT SIGN \EMERGENCY LIGHT

F10SIGN LIGHTER12" STAND OFFS

F7LINEAR RECESSEDWALL WASH

F34' TRACK LIGHT

F6PINHOLE LIGHT

F5LED TAPELOBBY CLOUD

F4BGRANDE PENDANT8'-0" AFF

F4AMEDIUM PENDANT9'-0", 8'-6" AFF

A.F

.F.

BH

-110' -

0"A.F.F.

CD-110' - 0"

A.F

.F.

CL-1

12' -

0"

A.F.F.ACT-1

9' - 0"

A.F.F.ACT-1

9' - 0"

A.F.F.ACT-1

9' - 0"

A.F.F.ACT-1

9' - 0"

A.F.F.ACT-1

9' - 0"

A.F.F.CL-1

10' - 0"

A.F.F.ACT-1

9' - 0"

A.F.F.CL-1

9' - 0"A.F.F.ACT-1

9' - 0"

A.F.F.ACT-1

10' - 0"

F9

F9

F9F9

F9F1

F6

F6

F1

F1

F1

F1

F7

F7

F7

F1

F1

F7

F1

F1

F6

F6

F6

F6

F1

F1

F7

F1

F1

F7

F7

F1

F1

F1

F1 F1

F1

F1

F1

F1F1F1

E1/E2

E1/E2

F10

F1

F1F1

F6

F6

E2

F4A

F4A

F4B

2' -

0 1

/4"

7' -

6 1

/2"

2' -

0 1

/4"

2' - 4" 5' - 0" 5' - 0" 1' - 6" 4' - 10 3/4"

3' -

7 1

/8"

3' -

0"

3' -

0"

2' -

9"

2' - 4" 4' - 8"

9' - 6"

3' -

0"

2' -

0"

2' -

6 5

/8"

2' - 0"

1' - 6"2

' -

0"

2' -

0"

EXISTING ROOF OR FLOOR ABOVE

NOTE: REFER TO ELEVATIONS

FOR FINISH INFORMATION

B.O. LIGHT SHELF

RE: 1/A2.4

B.O. CEILING

RE: 1/A2.4

T.O. SLABRE: A2.1,A2.3

HOLD METAL STUDS 1/2" SHORT OF ROOF DECK

TO ALLOW FOR MOVEMENT WITH SLIP

TRACK. PROVIDE CROSS BRACING FOR STABILITY.

LED LIGHT STRIP ON GYP, RE: ELEC

WH

ER

E O

CC

UR

S

18

" A

FF

1' -

0"

AP-1, ACRYLIC PANEL

4 3/8" TYP

4' - 0"

4' - 0" 1' - 0"

1' -

0"

8" COMPASSO TRIM WITH CLIPS TO GYP CEILING SUPPORT SYSTEM

8" COMPASSO TRIM WITH CLIPS TO GYP CEILING SUPPORT SYSTEM

5/8" GYP ON FRAMING

CEILING ELECTRICAL BOX FOR PENDANTS, RE: ELEC

FULL HEIGHT WALL OR STOREFRONT

5/8" GYP ON 3-5/8" FRAMING(WALL NOT USED ON LOCATIONS ABUTTED AGAINST GLASS)

LED LIGHT STRIP ON GYP,

RE: ELEC

AT FRONT/PANELAT BACK/WALL

REG

ISTERED ARCH

ITEC

T

19554

JEFF

REY K . BAKER

S

TA T E OF T EXA

S

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

10/7

/2021

8:1

4:0

3A

M

A2.4REFLECTED CEILING PLAN

TE

NA

NT

FIN

ISH

FO

R

JKB

CEB

09.21.2021

ETM2016

ELE

ME

NT

S M

AS

SA

GE

SA

N A

NT

ON

IO17

03

8 F

IES

TA

TE

XA

S D

RIV

ES

UIT

E 1

08

SA

N A

NT

ON

IO,

TX

782

56

TYPE DESCRIPTION MFR MODEL NOTES

ACT-1 LAY IN CEILING TILE INGRID

ROCKFON TROPIC SQ. -CHICAGOMETALLICALUM CAPGRID 1260/1280EXPOSED

WHITE TILE, GRID &TRIM

BH-1 BULKHEAD BY GC 5/8" GWB ON3-MTL STUD @16" O.C.

LEVEL 4 FINISH

CD-1 CEILING CLOUD BY GC 5/8" GWB ON3-5/8" MTLSTUD @ 16"O.C.

LEVEL 4 FINISH, P-5

CL-1 FLAT CEILING BY GC 5/8" GWB ON3-5/8" MTLSTUD @ 16"O.C.

LEVEL 4 FINISH, P-2

KEYED NOTES

1. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR MANUFACTURER'S INFORMATION AND SPECIFICATIONS CONCERNING FIXTURES SHOWN ON THIS PLAN.

2. GYPSUM WALLBOARD ON ALL BULKHEADS TO EXTEND 6" ABOVE ADJACENT SUSPENDED GRID CEILING.

3. CEILING DIFFUSERS IN GYP CEILINGS TO BE WHITE.4. REFER TO ELECTRICAL SHEETS FOR LIGHT FIXTURE SYMBOLS AND

SPECIFICATIONS.5. PROVIDE A WIRE CEILING HANGER AT EACH OF TWO DIAGONALLY OPPOSED

CORNERS FOR EACH LAY-IN LIGHT FIXTURE AND HVAC REGISTER.

SHEET NOTESCEILING TYPE SCHEDULE

LIGHT FIXTURE KEY

1/4" = 1'-0"1

REFLECTED CEILING PLAN

REQUIRED VENDOR CONTACT - WEDENBAUGH BROWN FOR NATIONAL PRICINGJOSH HUISKEN @ 714.553.5993 [email protected]

1/2" = 1'-0"2

ETM LIGHT SHELF

1SPECTRIO TO VERIFY LOCATIONS AND QUANTITIES OF SPEAKERS & WHITE NOISE DEVICES FOR OPTIMAL LOCATIONS

2 LIGHT COVE LIGHTING, RE: DETAIL THIS SHEET

3 CENTER CEILING CLOUD IN ROOM

4

5GC TO PROVIDE ALTERNATE PRICE TO LAY SOUND BATT INSUL OVER THE TOP OF ALL MASSAGE ROOM GRID CEILINGS

1

1

2

2 3

55

55

55

5

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

A2.6

1

4

5 3

60x59

ø 60"

30x48

x60

18"

MIN

T-1A

P-6

T-1A

T-2

P-6

5' - 0"

TA2C

TA2B

TA1T-1A

T-2

TA2A

TA3

T-1A

T-2

P-6

3' - 0"

36" REAR GRAB BAR 42"-48" SIDE GRAB BAR & VERTICAL GRAB BAR

TO

TO

P

33

" -

36

"

WATER CLOSET(FRONT)

TO ADJACENTPLUMBING FIXTURE

FLUSH HANDLE MUST FACE WIDE SIDE

TOILET TISSUE DISPENSER

SEAT COVER DISPENSER

SANITARY NAPKIN / TAMPON DISPOSAL

URINAL(FRONT)

URINAL(SIDE)

18" X 36" MIRROR SOAP DISPENSER

PAPER TOWEL DISPENSER

WALL-MOUNTED LAVATORY / INSULATE DRAIN

& HOT WATER LINES

TO

RE

FLE

CT

IVE

SU

RF

AC

E

6' -

2"

MIN

TO

RE

FLE

CT

IVE

SU

RF

AC

E

2' -

3"

2' -

10

"

MA

X T

O R

IM

MIN

CLR

DIAPER CHANGING STATION

TO

T.O

. C

HA

NG

ING

S

UR

FA

CE

TO

B.O

. U

NIT

MUST INSTALL BEYOND WC AND SINK REQUIREMENTS

SINGLE COAT HOOK

4' -

0"

45°

CENTERED ON TACTILE CHARACTERS

RESTROOM SIGNAGE

60" MIN CLEAR

17

" -

19

"16" - 18"

TO

TO

P

33

" -

36

"

36" BAR

6"

54" MIN

42" MIN

12" MAX

18"

BA

R3

9"

- 41

"

3' - 4"

44"

MA

X

17"

MA

X

13 1/2" MIN

17"

MA

X

19"

MIN

DISPENSER6" FROM TISSUE

2' -

6"

1' - 3" MIN1' - 6" PREFERED

3' -

4"

MA

X

TO

DIS

PE

NS

ER

48"

MA

X

TO

DIS

PE

NS

ER

48"

MA

X

2' -

6 1

/2"

2' -

10

" 5' -

0"

9"

1220

48"

MIN

1525

60"

MA

X

455

1' -

6"

MIN

4551' - 6" MIN

42" MAX3' - 6"

15"

MIN

7"-9"

48"

MA

X

1' - 0"

2' - 0"

REG

ISTERED ARCH

ITEC

T

19554

JEFF

REY K . BAKER

S

TA T E OF T EXA

S

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

10/7

/2021

8:1

4:0

4A

M

A2.6RESTROOM PLANS &

ELEVATIONS

TE

NA

NT

FIN

ISH

FO

R

JKB

CEB

09.21.2021

ETM2016

ELE

ME

NT

S M

AS

SA

GE

SA

N A

NT

ON

IO17

03

8 F

IES

TA

TE

XA

S D

RIV

ES

UIT

E 1

08

SA

N A

NT

ON

IO,

TX

782

56

KEYED NOTES

1. GC TO PROVIDE AND INSTALL ADA RESTROOM SIGNAGE AS REQUIRED BY LOCAL CODE. REFER TO THIS SHEET FOR MINIMUM REQUIREMENTS. COLOR-CHARCOAL GRAY

2. REFER TO PLUMBING SHEETS FOR FULL PLUMBING AND EQUIPMENT SCHEDULES.3. REFER TO FLOOR PLAN FOR BLOCKING REQUIREMENTS.4. GC TO ENSURE ALL ACCESSORIES ARE INSTALLED TO MEET LOCAL ACCESSIBILITY

REQUIREMENTS.5. GC TO PROVIDE ADEQUATE BLOCKING BEHIND ALL RESTROOM ACCESSORIES AND

EQUIPMENT.

SHEET NOTES

ITEM NO. QTY DESCRIPTION MANUFACTURER MODEL NOTES PROVIDED BY

INSTALLED

BY

TA1 1 B6857 SINGLE ROLL SURFACE MOUNTED DISPENSER -SATIN CHROME

BOBRICK B-6857 SERIES PROVIDE BLOCKING ASREQUIRED

GC GC

TA2A 1 B6806x36 STAINLESS STEEL W/ SNAP FLANGE - SATINCHROME

BOBRICK B-6806 SERIES PROVIDE BLOCKING ASREQUIRED

GC GC

TA2B 1 B6806x42 STAINLESS STEEL W/ SNAP FLANGE - SATINCHROME

BOBRICK B-6806 SERIES PROVIDE BLOCKING ASREQUIRED

GC GC

TA2C 1 B6806x18 STAINLESS STEEL W/ SNAP FLANGE - SATINCHROME

BOBRICK B-6806 SERIES PROVIDE BLOCKING ASREQUIRED

GC GC

TA3 1 B-165 CHANNEL FRAME MIRROR BOBRICK B-165 SERIES PROVIDE BLOCKING ASREQUIRED

GC GC

TOILET ACCESSORIES SCHEDULE

1/2" = 1'-0"2

ENLARGED RESTROOM PLAN

TERMINATE TILE EDGE WITH SCHLUTER STRIP1

GC TO PROVIDE BLOCKING SHOWN AND AS REQUIRED BY MFG & CODE2

3/8" = 1'-0"1

RESTROOM - SIDE WALL3/8" = 1'-0"

3RESTROOM - TOILET WALL

3/8" = 1'-0"4

RESTROOM - WET WALL3/8" = 1'-0"

5RESTROOM - DOOR

1/4" = 1'-0"6

TAS FIXTURE MOUNTING HEIGHTS

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

1

2

2

2

RB-1

P-1

P-5

P-5

P-1

AP

?

P-1

P-5

P-5

P-5

P-1

RB-1

P-1

RB-1

P-1

RB-1

P-1

9' -

0"

RB-3

P-7

RB-2

WC-1

RB-2

P-4

RB-2

P-4

RB-2

P-4

RB-2

P-4

?

P-1

M-7.U36 M-7.U36 M-7.W30 M-7.W30 M-7.U36

M-7.B30 M-7.B30 M-7.SBM-7.SB

7' -

6"

RB-1

P-1

P-1

P-1

FRP

RB-1

P-1

7' -

6"

M-7.W30 M-7W24 M-7.W30M-6.W36M-6.W36

RB-1

P-1 P-1

RB-1

P-1

P-1

RB-1

P-1

FRP

WC-2

RB-3

P-7

RB-3 RB-3

P-7 1' -

0"

3' -

8"

1' - 0"1' - 0"

REG

ISTERED ARCH

ITEC

T

19554

JEFF

REY K . BAKER

S

TA T E OF T EXA

S

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

10/7

/2021

8:1

4:0

7A

M

A4.1INTERIOR ELEVATIONS

TE

NA

NT

FIN

ISH

FO

R

JKB

CEB

09.21.2021

ETM2016

ELE

ME

NT

S M

AS

SA

GE

SA

N A

NT

ON

IO17

03

8 F

IES

TA

TE

XA

S D

RIV

ES

UIT

E 1

08

SA

N A

NT

ON

IO,

TX

782

56

KEYED NOTES

WALL FINISH KEY RE: A2.3 FOR FULL SCHEDULE

TAG DESCRIPTION MANUFACTURER & COLOR, PATTERN, ETC.

AP-1 ACRYLIC DIVIDER 3FORM - 3/8" VARIA ECORESIN "BRANCH COLOR" -VELLUM F04 (ONE SIDE)

AP-2 ACRYLIC ACCENT 3FORM - CHROMA "ALOE G60+OAT N23+REEFB18+AVALANCHE D01" - VELLUM F04 F&B

C-1 CARPET TILE J&J FLOORING - KINETEX "STRATA"

FRP FRP MARLITE P-100 WHITE

P-1 WHITE INTERIOR LATEX BENJAMIN MOORE - PM-3 "DECORATOR'S WHITE"

P-2 CEILING INTERIOR LATEX SHERWIN WILLIAMS - SW7757 "HIGH-REFLECTIVE WHITE"

P-3 ACCENT WALL PAINT BENJAMIN MOORE - 2125-30"GRAY SHOWER"

P-4 ACCENT WALL PAINT SHERWIN WILLIAMS - SW7018 "DOVETAIL"

P-5 ACCENT WALL PAINT SHERWIN WILLIAMS - PROMAR 200 ZERO VOC (OZW1-6/L1-0/R3-0/Y1-2) (32 W1-13/L1-31/R3-16/Y1-10) (64W1-0/L1-0/R3-0/Y1-0) (128 W1-0/L1-0/R3-1/Y1-0)

P-6 ACCENT WALL PAINT SHERWIN WILLIAMS - SW7035 "AESTHETIC WHITE"

P-7 ACCENT WALL PAINT SHERWIN WILLIAMS - SW7044 "AMAZING GRAY"

PL-2 PLASTIC LAMINATE WILSONART - 7937-38 "RIVER CHERRY"

PL-3 PLASTIC LAMINATE NEVAMAR - WZ0049-V "CREMA"

PL-4 PLASTIC LAMINATE WILSONART - 7938-38 "NEW AGE OAK"

PL-5 PLASTIC LAMINATE WILSONART - 1849K-35 "LUNA FROST"

RB-1 RUBBER BASE TARKETT - 469 "MYSTIFY" 4 INCH

RB-2 RUBBER BASE TARKETT - 29 "MOON ROCK" 4 INCH

RB-3 RUBBER BASE TARKETT - 283 "TOAST" 4 INCH

RF-1 "CONCRETE" TILE MANNINGTON SPACIA SS5S3071 - "GALLERY CONCRETE"12x18x2.5MM

RF-2 CLASSIC WALNUTPLANKS

MANNINGTON AMTICO AROW7610 6x36 2.5MM

SS-1 SOLID SURFACE LG - HI-MACS 1/2" -GT910 "EGG WHITE

ST-1 WOOD STAIN MINWAX CLASSIC GRAY MW271

T-1 FLOOR TILE CROSSVILLE - NEST "JOYOUS OLIVE" 6"x36"

T-1A FLOOR TILE TRIM CROSSVILLE - NEST "JOYOUS OLIVE" 3"x15"

T-2 WALL TILE OLYMPIA TILE & STONE - SHADEBRICK "LIGHT" 3"x12"

WC-1 WALL COVERING -CORRIDOR

TRIKES - "RIVOLI" - LV-RI-04

WC-2 WALL COVERING -ROOMS

MDC - "TAPA" - TFC1286/4766

SIMILAR FINISHES ON ELEVATIONS NOT SHOWN, TYP1

GC TO PROVIDE PLYWOOD BLOCKING AS SHOWN AND REQUIRED2

TIMECLOCK. RE: ELEC3

4 ADA/ANSI COMPLIANT SINK SKIRT

5 COAT HOOKS BY OWNER, INSTALLED BY GC

1/4" = 1'-0"1

LOBBY - ENTRANCE1/4" = 1'-0"

2LOBBY - WAITING

1/4" = 1'-0"3

LOBBY - HALLWAY DOOR1/4" = 1'-0"

4LOBBY - RECEPTION DESK

1/4" = 1'-0"5

MASSAGE ROOM - TYPICAL

1/4" = 1'-0"9

HALLWAY - PLAN WEST1/4" = 1'-0"

10HALLWAY - DRINKING FOUNTAIN

1/4" = 1'-0"11

HALLWAY - PLAN EAST1/4" = 1'-0"

12HALLWAY - LOBBY DOOR

1/4" = 1'-0"13

BREAK ROOM - KITCHENETTE1/4" = 1'-0"

14BREAK ROOM - PLAN SOUTH

1/4" = 1'-0"15

BREAK ROOM - DOOR

1/4" = 1'-0"16

BREAK ROOM - COUNTERS1/4" = 1'-0"

17BREAK ROOM - LOCKERS

1/4" = 1'-0"18

BREAK ROOM - LAUNDRY

1/4" = 1'-0"6

MASSAGE ROOM - TYP HEAD WALL1/4" = 1'-0"

7MASSAGE ROOM - TYP DOOR WALL

1/4" = 1'-0"8

MASSAGE ROOM - TYP FOOT WALL

3

44

2

2

2

2

2

5

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

INSIDE CLEAR INSULATIONDIMENSION

EQUIPMENT MARK(SEE SCHEDULES)

12x12

FIRE DAMPER

VOLUME DAMPER (TYP)

RECTANGULAR DUCTSIDE CONNECTION OF

INSUL FLEX ROUND DUCT

SIDE CONNECTION OF

TOP (OR BOTTOM) CONN

ROUND DUCT

OF ROUND DUCT

TRUNK DUCT ELBOW(TURNING VANES REQ'D)

RETURN OR EXHAUST DUCT DN

RETURN OR EXHAUST DUCT UP

0.5A

A

DESCRIPTION

SUPPLY DUCT UP

SUPPLY DUCT DN

SYMBOL

H.V.A.C. LEGEND

EXISTING(E)

DESCRIPTIONSYMBOL

CONNECT NEW TO EXISITNG

RTU

1

SCOPE OF WORK:NEW ELEMENTS MASSAGE.NEW MECHANICAL UNITS.NEW EXHAUST FANS.NEW DUCTWORK AND DISTRIBUTIONTHROUGHOUT.

VENTILATION SCHEDULE(PER IMC, TABLE 403.3)

ROOM NAME(S)

BREAK ROOM

LOBBY

CORRIDOR

MASSAGE ROOM

MASSAGE ROOM

MASSAGE ROOM

MASSAGE ROOM

MASSAGE ROOM

MASSAGE ROOM

MASSAGE ROOM* OUTSIDE AIR PER SQ. FT. CALCULATED BY THE USE OF EQUATION 4-1 AND EQUATION 4-2 OF IMC.NOTES:

OCCUPANCY

CLASSIFICATION

OFFICE SPACES

RECEPTION AREAS

CORRIDORS

PATIENT ROOMS

PATIENT ROOMS

PATIENT ROOMS

PATIENT ROOMS

PATIENT ROOMS

PATIENT ROOMS

PATIENT ROOMS

ROOM

AREA

(SF)

234

232

209

95

95

95

95

95

95

95

PERSONS

PER 1000 SF

5

30

10

10

10

10

10

10

10

Rp

PEOPLE

AIRFLOW

5

5

25

25

25

25

25

25

25

Ra

ZONE

AIRFLOW

0.06

0.06

0.06

Exhaust

AIRFLOW

RATE CFM/SF

TOTAL

PERSONS

2

7

0

1

1

1

1

1

1

1

ZONE

Ez

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

OUTSIDE AIR

PER SQ. FT.

PER IMC*

0.11

0.26

0.08

0.31

0.31

0.31

0.31

0.31

0.31

0.31

OUTSIDE AIR

REQUIRED

(CFM)

25

61

16

30

30

30

30

30

30

30

%OSA OF

SUPPLYING RTU

(CFM)

20.0%

20.0%

20.0%

20.0%

20.0%

20.0%

20.0%

20.0%

20.0%

20.0%

MIN SUPPLY

REQUIRED

(CFM)

124

305

78

148

148

148

148

148

148

148

SUPPLY

PROVIDED

200

600

100

150

150

150

150

150

150

150

SUPPLIED BY

AIR BALANCE SCHEDULE (CFM)TAG

EF-1,2RTU-1TOTALS

SUPPLYAIR--

2,0002,000

RETURNAIR--

1,6001,600

EXHAUSTAIR150--

150

OUTSIDEAIR--

400400

OUTSIDEAIR %

--20--

BUILDING PRESSURE

-150400250

NEW CEILING CASSETTE SCHEDULE

Mark(s)

CS-1

NOTES:

Manufacturer / Model No.

Mitsubishi MLZ-KP18NA

1. Provide thermostat per manufacturer requirements.

NOM.

TONS

1.5

CFM

311

VOLTAGE& PHASE

115/1

ELECTRICAL

MCA

1

MOCP

15

LENGTH(IN)

43-3/8

SIZE

WIDTH(IN)

14-3/16

HEIGHT(IN)

7-5/16

WEIGHT(LBS)

34

NEW CONDENSING UNIT SCHEDULE

Mark(s)

CU-1

NOTES:

Manufacturer / Model No.

Mitsubishi SUZ-KA18NA2

1. All refrigeration piping to be installed and insulated per manufacturer's specifications.

NOM.

TONS

1.5

SEER

22.3

HSPF

12.4

HEATING @ 17F

Max

13.1

Rated

13.1

COOLING

Sens

18

Total

18

VOLTAGE& PHASE

208/1

ELECTRICAL

MCA

14

MOCP

25

LENGTH(IN)

13

SIZE

WIDTH(IN)

33-1/16

HEIGHT(IN)

34-5/8

WEIGHT(LBS)

127

DIFFUSER, REGISTER & GRILLE SCHEDULE

Mark(s)

CD

CD1

RG

SD

Manufacturer / Model No.

Titus TMS or equal

Titus MCD or equal

Titus 355 RL

Titus ML-39 or equal

DESCRIPTION

T-Bar Ceiling Diffuser

Modular Core Ceiling Diffuser

Ceiling Return

Slot Diffuser w/(4) 1"slot

CONSTRUCTION

Steel

Steel

Steel

Aluminum

NOM. CFM

See Plans

See Plans

See Plans

See Plans

SIZE

See Plans

See Plans

See Plans

4 ft long

MOUNTING

T-Bar Lay-in

Surface mount

Per Ceiling Type

Surface mount

REMARKS

Paintable, color per Architect

4-way pattern unless otherwise noted

35 deg. fixed blades

EXHAUST FAN SCHEDULE

MARK(S)

EF-1

EF-2

NOTES:

FAN CONTROL:

MANUFACTURER/MODEL

Greenheck - SPA-110

Greenheck - SPA-110

1. Intergral gravity backdraft damper

7. 12" Manufacturer's roof curb

A. Separate wall switch

LOCATION

Restroom

Mop Sink

8. 18" Manufacturer's ventilated roof curb

B. Switch on with lights

SERVING

Restroom

Mop Sink

2. Ducted from fan outlet to roof

CFM

75

75

C. 24/7 time clock to operate during occupied times

ESPin

0.25

0.25

3. SMACNA approved roof cap

Wattsor HP

49

49

MOTORVoltage &

Phase

115/1

115/1

RPM

750

750

4. Ducted from fan outlet to wall

DamperType

Backdraft

Backdraft

D. Continuous operation

FanControl

B

B

5. Wall exhaust louver, see plans for size

ROOFOPENING

in x in

6"dia thru roof

6"dia thru roof

E. Interlock with equipment (Marks shown)

WEIGHT

lbs.

17

17

6. 1/4" galv. mesh birdscreen

NOTESlbs.

1, 2, 4, 6

1, 2, 4, 6

ROOFTOP UNIT SCHEDULE

Mark(s)

RTU-1

NOTES:

Manufacturer / Model No.

Carrier 50HCQD07D1A5-0F1C0

1. Provide Duct mounted smoke detectors in return duct per code.

2. Provide 14" in. high manufacturer's roof curb, flash and seal to roof.

3. Provide 100% enthalpy controlled economizer, with integral barometric relief set to minimum outside air requirements as shown on Ventilation Schedule.

4. Provide Honeywell programmable thermostat and provide with two remote averaging sensors.

5. Provide louvered hail guards on all units.

NOM.TONS

6

EER

12

COP

3.4

COOLING

Sens

52.71

Total

68.34

AMB.AIR

TEMP

98

EATDB

ºF

80.4

WB

ºF

65.9

HEATING

Sens

67.82

Total

67.82

SUPPLY FAN

CFM

2000

ESP

0.5

SUPPLY

FAN (HP)

0.73

VOLTAGE

& PHASE

208/3

ELECTRICAL

MCA

32

MOCP

50

LENGTH

(IN)

88.125

SIZEWIDTH

(IN)

59.5

HEIGHT

(IN)

41.25

WEIGHT

(LBS)

991

MECHANICAL SPECIFICATIONSTHE DRAWINGS INDICATE DIAGRAMMATICALLY THE EXTENT, GENERALCHARACTER, AND LOCATION OF THE WORK INCLUDED. OFFSETS AND/ORCHANGES IN ELEVATION OF PIPING AND DUCTWORK DUE TO STRUCTURAL OROTHER INTERFERENCES SHALL BE PROVIDED WITHOUT EXTRA COST.

VERIFY AND EVALUATE ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENTOF WORK.

PROVIDE ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THEINSTALLATION OF A COMPLETE AND OPERATING SYSTEM. PROVIDE CONTROLWIRING NECESSARY FOR THE OPERATION OF THE MECHANICAL SYSTEMSINDICATED ON THE MECHANICAL DRAWINGS. THIS SHALL INCLUDE, BUT NOTBE LIMITED TO, THERMOSTATS.

ENTIRE NEW WORK INSTALLATION SHALL CONFORM WITH ALL APPLICABLELAWS, CODES AND REGULATIONS OF MUNICIPAL, STATE AND FEDERALAUTHORITIES INCLUDING: THE INTERNATIONAL BUILDING, MECHANICAL, ANDENERGY CONSERVATION CODES; ANY AND ALL LOCAL AMENDMENTSADOPTED AND ENFORCED BY THE LOCAL JURISDICTION; ASME; ASTM; ASHRAE;SMACNA; AND NFPA.

WHERE REQUIRED BY CODE, ALL WORK MUST BE INSPECTED AND APPROVED BYLOCAL AUTHORITIES. PRIOR TO FINAL ACCEPTANCE, FURNISH THEARCHITECT/OWNER WITH CERTIFICATES OF INSPECTION AND APPROVALS BYLOCAL AUTHORITIES.

PROVIDE ALL DAMPER CONTROL HANDLES, ELECTRIC CONTROLS, AIRCONTROLS, MECHANICAL EQUIPMENT, AND OTHER APPARATUS THAT MUST BEPROVIDED IN AN INACCESSIBLE LOCATION WITH SUITABLE ACCESS DOORS ORCOVERS IN A FRAMED OPENING, WHICH WILL PERMIT PROPER OPERATION ANDSERVICING.

BEFORE ACCEPTANCE AND FINAL PAYMENT, DEMONSTRATE THAT ALLAPPARATUS ARE FUNCTIONING PROPERLY AND EFFICIENTLY. STARTUPS ANDADJUSTMENTS FOR THE FIRST HEATING AND THE FIRST COOLING SEASONSHALL BE INCLUDED IN THE BID.

SYSTEM, MATERIAL, AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIODOF ONE YEAR AFTER THE COMPLETION AND ACCEPTANCE. REPLACE ALLDEFECTIVE WORKMANSHIP, EQUIPMENT AND MATERIALS WITHOUT ADDITIONALCHARGES, INCLUDING REFRIGERANT THAT IS LOST DURING RELATED REPAIRS.

TESTING, ADJUSTING, AND BALANCING SHALL BE PERFORMED INACCORDANCE WITH THE MOST CURRENT ASHRAE HANDBOOK OF HVACAPPLICATIONS, CHAPTER 36. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO:* BALANCING AIR DISTRIBUTION SYSTEMS* ADJUSTING THE TOTAL SYSTEM TO PROVIDE DESIGN QUANTITIES* ELECTRICAL MEASUREMENT* ESTABLISHING QUANTITATIVE PERFORMANCE OF ALL HVAC EQUIPMENT* VERIFYING AUTOMATIC CONTROLS

ADJUST AIR FLOWS FOR TERMINALS TO WITHIN +/- 10%. ADJUST AIR FLOWS INDUCT MAINS TO WITHIN +/- 5%, USING THE PITOT-TUBE TRANSVERSE METHOD.FURNISH TO THE ARCHITECT, FIVE (5) COPIES OF THE TESTING AND BALANCINGREPORT.

DUCTWORK SHALL BE GALVANIZED STEEL, CONSTRUCTED, INSTALLED, ANDSUPPORTED IN ACCORDANCE WITH THE "SMACNA" APPLICABLE MANUALS. ALLDUCTWORK SHALL BE THE LOW VELOCITY TYPE, UNLESS OTHERWISE SPECIFIED.WHERE DUCTWORK IS EXPOSED TO VIEW, SUPPORT WITH THREADED RODHANGER AND UNISTRUT. UNISTRUT SHALL HAVE (HOT-DIPPED GALVANIZED,GREEN) FACTORY FINISH.

ALL DUCT TAKE-OFFS SHALL BE PROVIDED WITH A MANUAL DAMPER. SUFFICIENTMANUAL DAMPERS SHALL BE PROVIDED AND INSTALLED FOR BALANCING OFTHE SUPPLY AIR SYSTEM AND THE OUTSIDE AIR/ RETURN AIR SYSTEMS.

ALL EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THEMANUFACTURER'S PUBLISHED INSTRUCTIONS AND SHALL PROVIDE EXTRAMATERIALS REQUIRED FOR A PROPER INSTALLATION.

DUCT JOINTS FOR LOW PRESSURE DUCTWORK SHALL BE SEALED TO MEET THESMACNA 1" W.C. PRESSURE CLASSIFICATION. SEAL ALL TRANSVERSE JOINTS WITHIRON-GRIP 601 AS MANUFACTURED BY HARDCAST. APPLY PER MANUFACTURER'SINSTRUCTIONS. DUCT TAPE IS NOT AN ACCEPTABLE MEANS OF SEALINGDUCTS. EXCEPTION: DO NOT SEAL EXPOSED DUCTWORK.

DUCT DIMENSIONS SHOWN ARE SHEET METAL OR WHERE LINED INTERNALDIMENSIONS (UNLESS OTHERWISE NOTED). DUCT DIMENSIONS MAY BECHANGED IF THE NET FREE FACE AREA IS MAINTAINED.

ALL DUCT CONNECTIONS TO FAN DRIVEN UNITS SHALL BE MADE WITH 4-IN.LONG FIREPROOF FLEXIBLE DUCT CONNECTOR FOR VIBRATION SOUNDISOLATION.

CONDENSATE PIPING ABOVE THE ROOF SHALL BE PVC PIPE, ASTM D 2665,SOLID-WALL DRAIN, WASTE AND VENT PIPING WITH PVC SOCKET FITTINGSCOMPLYING WITH ASTM D 2665, SOCKET TYPE, MADE TO ASTM D 3311, DRAIN,WASTE, AND VENT PATTERNS. FOR EACH ROOFTOP UNIT, PROVIDE TRAP ATCONDENSATE CONNECTION AND PIPE TO NEAREST ROOF DRAIN OR SCUPPERINLET.

THIS WORK SHALL BE PERFORMED IN A CLEAN AND PROFESSIONAL MANNER.CARE SHALL BE EXERCISED TO MINIMIZE INCONVENIENCE OR DISTURBANCE TOOTHER TRADES DURING CONSTRUCTION. ISOLATE WORK AREAS BY MEANS OFTEMPORARY PARTITIONS AND/OR TARPS TO KEEP DUST AND DEBRIS WITHIN THECONSTRUCTION AREA. CLEAN THE JOB SITE DAILY AND REMOVE FROM THEPREMISES ANY DIRT AND DEBRIS CAUSED BY THE PERFORMANCE OF THE WORKINCLUDED IN THIS CONTRACT.

FIELD VERIFY ALL DIMENSIONS, EXISTING CONDITIONS, AND BUILDING POWER,VOLTAGE, AND PHASE PRIOR TO ORDERING EQUIPMENT AND PROCEEDINGWITH ANY WORK. WHERE DISCREPANCIES OCCUR BETWEEN THESEDOCUMENTS AND EXISTING CONDITIONS, THE DISCREPANCY SHALL BEREPORTED TO THE OWNER AND MECHANICAL ENGINEER IMMEDIATELY FORRESOLUTION.

THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFEKEEPING OF HIS/HEROWN PROPERTY ON THE JOB SITE. THE OWNER OR TENANT ASSUMES NORESPONSIBILITY FOR PROTECTION OF THIS CONTRACTOR'S PROPERTY AGAINSTFIRE, THEFT, OR ENVIRONMENTAL CONDITIONS.

WHERE CONDUIT, CABLES, DUCTWORK OR PIPING PASSES THROUGH FIRERATED FLOORS, WALLS, OR PARTITIONS, THE SLEEVES SHALL BE COMPLETELYSEALED WITH A FIRE STOP MATERIAL THAT IS U.L. LISTED (EQUAL TO DOWCORNING) AND ACCEPTED BY THE BUILDING DEPARTMENT AND FIREDEPARTMENT AS BEING SUITABLE FOR THE SERVICE. THIS MATERIAL SHALL BEINSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHEDINSTRUCTIONS IN ORDER TO MAINTAIN THE FIRE RATING OF THE PENETRATEDWALL, FLOOR, OR PARTITION. INSTALLATION SHALL BE ATHROUGH-PENETRATION FIRESTOP SYSTEM INSTALLED AS TESTED INACCORDANCE WITH ASTM E 814 AND UL 1479. THE FIRE RATING SHALL MATCHTHE RATING OF THE BARRIER BEING PENETRATED.

SUBMIT (1) PDF FILE OR SIX (6) SETS OF SHOP DRAWINGS, CONTROL DIAGRAMS,AND EQUIPMENT CUTS TO THE MECHANICAL ENGINEER FOR APPROVAL PRIORTO STARTING RELATED WORK. UPON COMPLETION OF CONSTRUCTION,SUPPLY THE MECHANICAL ENGINEER WITH ONE COMPLETE SET OF FULL SIZEAS-BUILT DRAWINGS AND ONE FULL SIZED PDF FILE. PROVIDE THE OWNER WITH(1) PDF AND THREE (3) SETS OF OPERATION AND MAINTENANCE MANUALS FOREACH TYPE OF EQUIPMENT INSTALLED.

SUBMISSION OF PROPOSAL IN CONNECTION WITH THIS WORK SHALL IMPLYTHAT THE BIDDER HAS EXAMINED THE JOB SITE. NO EXTRA CHARGE WILL BEALLOWED FOR CHANGES AS A RESULT FROM FAILURE TO EXAMINE THE JOBSITE.

THIS CONTRACTOR SHALL SECURE AND PAY ALL FEES AND PERMITS PERTAININGTO THIS CONTRACT, SHALL BE RESPONSIBLE FOR WORKER'S IDENTIFICATIONAND BADGING, SAFETY, AND LIABILITY INSURANCE. PROVIDE BARRICADES,WARNING SIGNS, AND TRASH REMOVAL FOR THE SAFETY OF THE WORKERSUNDER THIS CONTRACTOR'S EMPLOY.

THIS CONTRACTOR SHALL ASSUME ALL ADDED EXPENSES TO ALL TRADESASSOCIATED WITH THE INSTALLATION OF SUBMITTED AND APPROVEDALTERNATE EQUIPMENT.

DUCT INSULATION:

RECTANGULAR SUPPLY AND RETURN DUCTWORK CONCEALED ABOVE CEILINGSSHALL BE, INSULATED WITH A MINIMUM INSTALLED R-VALUE OF 6, INTERNALLYLINED WITH ACOUSTICAL LINER EQUAL TO JOHNS MANVILLE LINACOUSTIC RCFIBERGLASS DUCT LINER WITH REINFORCED COATING SYSTEM 1-1/2 INCHESTHICK, R-6.3, NFPA 90A AND 90B COMPLIANT.

ROUND SUPPLY AND RETURN AIR DUCTWORK CONCEALED ABOVE CEILINGSSHALL BE INSULATED WITH FIBERGLASS DUCT INSULATION WITH FSK FACINGEQUAL TO JOHNS MANVILLE MICROLITE, 100# DENSITY, 2 INCHES THICK, WITHA MINIMUM INSTALLED R-VALUE OF 6. INSTALL PER MANUFACTURER'S PUBLISHEDINSTRUCTIONS. DUCTWORK THAT IS ACOUSTICALLY LINED DOES NOT REQUIREEXTERIOR INSULATION WHERE THE ACOUSTICAL LINING MEETS THE MINIMUMREQUIRED R-VALUE.

EXTERIOR DUCTWORK SHALL BE INSULATED WITH A MINIMUM INSTALLEDR-VALUE OF 8. WHERE EVAPORATIVE COOLING IS PRESENT THE DUCTWORKSHALL BE EXTERNALLY INSULATED AND WRAPPED IN A PROTECTIVE PVC ORMETAL SHEATHING.

EXPOSED DUCTWORK WITHIN CONDITIONED SPACE SHALL NOT BE EXTERNALLYINSULATED. CLEAN AND PREP FOR PAINTING (PAINT BY OTHERS). IN HUMIDREGIONS, ALL DUCTWORK SHALL BE INTERNALLY LINED OR EXTERNALLYINSULATED AND WRAPPED WITH A PROTECTIVE, PAINTABLE METAL COVERINGOR A PVC COVER.

OUTSIDE AIR DUCTS SHALL BE INSULATED; WHERE EXPOSED, THE INSULATIONSHALL BE INTERNAL ANTIMICROBIAL AND ANTIFUNGAL LINER.

WHERE DUCTWORK IS NOTED TO BE INSULATED DIFFERENTLY ON THEDRAWINGS (i.e. EXTERNAL INSULATION ON RECTANGULAR DUCTWORK), THECORRESPONDING INSULATION SPECIFICATIONS ABOVE SHALL APPLY.

GREASE EXHAUST DUCT SHALL BE CONSTRUCTED OF 16 GAGE WELDED BLACKIRON AND SHALL BE EXTERNALLY WRAPPED IN 2 LAYERS OF U.L. LISTED GREASEDUCT WRAP UP TOP ROOF PENETRATION. HORIZONTAL GREASE EXHAUSTDUCT SHALL BE PROVIDED WITH RATED CLEANOUTS PER MECHANICAL CODE.

CODE COMPLIANCE STATEMENTTHIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES:

· INTERNATIONAL MECHANICAL CODE : 2018

· INTERNATIONAL ENERGY CONSERVATION CODE (IECC) : 2018

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014FX: 303.362.7361

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

JPT

SCF

09.30.2021

KVA21-145/ETM2016

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

PROFESS I ONAL ENG I N EER

87066L I C E N S E D

JOHN TINSLEY

S T A T E O F T E X A S

FIRM NUMBER: 7684kVA Consulting

19600 E Parker Square Dr., B100, Parker, CO 80134(303) 646-4770 Direct | [email protected]

TEN

AN

T FI

NIS

H F

OR

ELE

ME

NTS

MA

SS

AG

ES

AN

AN

TON

IO17

038

FIE

STA

TE

XA

S D

RIV

ES

UIT

E 1

08S

AN

AN

TON

IO, T

X 7

8256

M0.0MECHANICAL SPECIFICATIONS

MECHANICAL SHEET NOTES1. VERIFY FINAL LOCATION OF ROOFTOP UNITS WITH STRUCTURAL

PRIOR TO ANY WORK.2. MAINTAIN 10'-0" HORIZONTAL CLEARANCE TO ALL MECHANICAL

FRESH AIR INTAKES FROM EXHAUST DISCHARGE POINT.3. VERIFY FINAL LOCATION OF THERMOSTATS WITH TENANT PRIOR TO

ANY WORK.4. PROVIDE 4" DRYER VENT TO EXHAUST TO ROOF. CENTER OF DUCT

OF SHALL BE 18" ABOVE FINISHED FLOOR. DUCTING SHALL BE INACCORDANCE TO THE MANUFACTURER'S RECOMMENDATIONS, ALLAPPLICABLE CODES, AND THE AHJ; IMC SECTION 504. ALLPENETRATIONS SHALL BE IN ACCORDANCE WITH ALL APPLICABLECODES. PROVIDE A BACKDRAFT DAMPER AT DUCT TERMINATION.

5. PROVIDE REMOTE DUCT SENSORS IN RETURNS.6. UNDERCUT DOOR 1".

#

SCALE:

1M1.0

MECHANICAL PLAN1/4"=1'-0"

8"ØCD150CFM

24X24RG

8"ØCD150CFM

8"ØCD150CFM

8"ØCD150CFM

8"ØCD150CFM

8"ØCD150CFM

8"ØCD150CFM

8"ØCD150CFM

8"ØCD150CFM

24X24RG

24X24RG

24X24RG

24X24RG

24X24RG

24X24RG

24X24RG

48"SD250CFM

CS

1

CU

1

48"SD250CFM

EF

1

EF

22

2

8"ØCD150CFM

24X24RG

8"ØCD150CFM

24X24RG

8"ØCD150CFM

1

3

4

5

6

RTU

1

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014FX: 303.362.7361

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

JPT

SCF

09.30.2021

KVA21-145/ETM2016

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

PROFESS I ONAL ENG I N EER

87066L I C E N S E D

JOHN TINSLEY

S T A T E O F T EX A S

FIRM NUMBER: 7684kVA Consulting

19600 E Parker Square Dr., B100, Parker, CO 80134(303) 646-4770 Direct | [email protected]

TEN

AN

T FI

NIS

H F

OR

ELE

ME

NTS

MA

SS

AG

ES

AN

AN

TON

IO17

038

FIE

STA

TE

XA

S D

RIV

ES

UIT

E 1

08S

AN

AN

TON

IO, T

X 7

8256

M1.0MECHANICAL PLAN

EXISTING. VERIFY LOCATION, SIZE, ANDCAPACITY.

(E)

CLEANOUT TO GRADE

11. ELBOW DOWN2. PRV (PRESSURE REDU VL)

ABOVE FINISH FLOORAFF

FLOOR DRAIN

ROOF DRAIN

VENT THRU ROOFVTR

RD

FD

COTG

BALANCE VALVE W/MEMORY

SYMBOL

BRONZE CHECK VALVE

BRONZE CONTROL VALVE

AGA LISTED GAS COCK

FEBCO 825Y OR EQUALBACKFLOW PREVENTER)

9"THERMOMETER ±1%

BRONZE UNION

RPBP (REDUCED PRESS

9.

7.

8.

5.

6.

3.

4.

DESCRIPTION

COLD WATER

ABBREV.

CW

SIDE T CONNECTION

BOTTOM T CONNECTION

TOP T CONNECTION

BRONZE STRAINER

SHOCK ABSORBER

ELBOW UPPIPE ANCHOR

CIRCUIT SETTER

MANUAL AIR VENTPRESSURE GAGE

16.

19.

17.18.

21.20.

12.

13.

15.

14.

3

15

BRONZE/STAINLESS BALL VALVE

VALVES, FITTINGS, ETC

11

1.

1312 14

1 2

19

END CAP10.

1716 18

4 5 6

2120

7 8 9 10

PLUMBING LEGEND

TOTAL DEVELOPED LENGTHTDL

CONNECT NEW TO EXISTING

SS SS

CD CD CD

FW FW FW

G G

GW GW

HWR HWR HWR

HWS HWS HWS

V V V

TW TW TW

ST ST

DV DV

O2 O2

CO2

(E)SS

(E)GW

(E)G

F F

SO SO

NO2

N N

HOT WATERHW

HOT WATER CIRCULATIONHWC

FILTERED WATERFW

TEMPERED WATERTW

SANITARY SEWERSS

GREASY WASTEGW

EXISTING SANITARY SEWER(E)SS

EXISTING GREASY WASTE(E)GW

WASTE VENTV

NATURAL GASG

CONDENSATE DRAINCD

EXISTING NATURAL GAS(E)G

HOT WATER SUPPLY, HYDRONICHWS

HOT WATER RETURN, HYDRONICHWR

STORM SEWERST

SAND/OIL WASTESO

COLD WATER SUPPLY, HYDRONICCWS

COLD WATER RETURN, HYDRONICCWR

INDIRECT WASTE LINEIDW

FIRE LINEF

OXYGEN LINEO2

CARBON DIOXIDE LINECO2

NITROGEN LINEN

NITROUS OXIDE LINENO2

COLD WATER RETURN, HYDRONICDV

CA CA COMPRESSED AIRCA

PLUMBING SPECIFICATIONS1.1 SUMMARY: PROVIDE PLUMBING WHERE SHOWN ON THE DRAWINGS, ASSPECIFIED HEREIN, AND AS NEEDED FOR A COMPLETE AND PROPERINSTALLATION INCLUDING, BUT NOT NECESSARILY LIMITED TO:

DOMESTIC HOT AND COLD WATER PIPING SYSTEMS

DRAIN, WASTE, AND VENT SYSTEMS

PLUMBING FIXTURES AND TRIM AS SHOWN ON THE DRAWINGS

FUEL GAS PIPING SYSTEM

STORM DRAINAGE SYSTEMS

DOCUMENTS AFFECTING WORK OF THIS SECTION INCLUDE, BUT ARE NOTNECESSARILY LIMITED TO GENERAL CONDITIONS, SUPPLEMENTARYCONDITIONS, AND SECTIONS IN DIVISION 1 OF THE ARCHITECTURALSPECIFICATIONS.

1.2 SUBMITTALS: COMPLY WITH PERTINENT PROVISIONS OF DIVISION 1 ANDTHE ARCHITECTURAL SCOPE.

PRODUCT DATA: WITHIN 30 CALENDAR DAYS AFTER THE CONTRACTOR HASRECEIVED THE OWNER'S NOTICE TO PROCEED, SUBMIT:

MATERIALS LIST OF ITEMS PROPOSED TO BE PROVIDED UNDER THIS SECTION

MANUFACTURER'S SPECIFICATIONS, CATALOG CUTS, AND OTHER DATANEEDED TO PROVE COMPLIANCE WITH THE SPECIFIED REQUIREMENTS.

SHOP DRAWINGS AND OTHER DATA AS REQUIRED TO INDICATE METHOD OFINSTALLING AND ATTACHING EQUIPMENT, EXCEPT WHERE SUCH DETAILS AREFULLY SHOWN ON THE DRAWINGS.

STERILIZATION CERTIFICATE: UPON COMPLETION OF DOMESTIC WATERPIPING SYSTEM, THE ADDED PORTION OF THE SYSTEM SHALL BE STERILIZED.UPON COMPLETION THE CONTRACTOR SHALL DELIVER TO THE ARCHITECTTWO (2) COPIES OF AN ACCEPTABLE "CERTIFICATE OF PERFORMANCE" FORTHIS ACTIVITY.

UPON COMPLETION OF THE WORK OF THIS SECTION, DELIVER TO THEARCHITECT FOUR (4) COPIES OF ALL SHOP DRAWINGS (EQUIPMENT ANDFIXTURE SUBMITTALS), OPERATION AND MAINTENANCE MANUALS ANDAS-BUILT (RECORD) DRAWINGS. ALL MANUALS SHALL INCLUDE AMAINTENANCE SCHEDULE FOR ALL REQUIRED EQUIPMENT (I.E. PUMPS, WATERFILTERS). ALL MANUALS SHALL BE COMPILED IN ACCORDANCE WITH THEPROVISIONS OF DIVISION 1 OF THESE SPECIFICATIONS.

1.3 QUALITY ASSURANCE: USE ADEQUATE NUMBERS OF SKILLED WORKERSWHO ARE THOROUGHLY TRAINED AND EXPERIENCED IN THE NECESSARYCRAFTS AND WHO ARE COMPLETELY FAMILIAR WITH THE SPECIFIEDREQUIREMENTS AND THE METHODS NEEDED FOR PROPER PERFORMANCE OFTHE WORK OF THIS SECTION.

CODES AND REGULATIONS: IN ADDITION TO COMPLYING WITH THESPECIFIED REQUIREMENTS, COMPLY WITH THE PERTINENT REGULATIONS OFGOVERNMENTAL AGENCIES HAVING JURISDICTION; INCLUDING THEINTERNATIONAL BUILDING, PLUMBING, FUEL GAS, AND ENERGYCONSERVATION CODES; AND ANY AMENDMENTS TO ABOVE CODESREQUIRED BY THE LOCAL AUTHORITIES. IN THE EVENT OF CONFLICT BETWEENOR AMONG SPECIFIED REQUIREMENTS AND PERTINENT REGULATIONS, THEMORE STRINGENT REQUIREMENT WILL GOVERN WHEN SO DIRECTED BY THEARCHITECT.

1.4 DELIVERY, STORAGE, AND HANDLING: COMPLY WITH THE PERTINENTPROVISIONS OF DIVISION 1.

1.5 GENERAL REQUIREMENTS: WHERE REQUIRED BY CODE, ALL WORK MUSTBE INSPECTED AND APPROVED BY LOCAL AUTHORITIES. PRIOR TO FINALACCEPTANCE, FURNISH THE ARCHITECT/OWNER WITH CERTIFICATES OFINSPECTION AND APPROVALS BY LOCAL AUTHORITIES. BEFORE ACCEPTANCEAND FINAL PAYMENT, DEMONSTRATE THAT ALL APPARATUS ARE FUNCTIONINGPROPERLY AND EFFICIENTLY. SYSTEM, MATERIAL, AND WORKMANSHIP SHALL BEGUARANTEED FOR A PERIOD OF ONE YEAR AFTER THE COMPLETION ANDACCEPTANCE. REPLACE ALL DEFECTIVE WORKMANSHIP, EQUIPMENT ANDMATERIALS WITHOUT ADDITIONAL CHARGES, INCLUDING REFRIGERANT THATIS LOST DURING RELATED REPAIRS.

PART 2 - PRODUCTS

2.1 PIPE SCHEDULE:

DRAIN, WASTE, AND VENT SYSTEM: PVC PIPE, ASTM D 2665, SOLID-WALLDRAIN, WASTE AND VENT PIPING WITH PVC SOCKET FITTINGS COMPLYINGWITH ASTM D 2665, SOCKET TYPE, MADE TO ASTM D 3311, DRAIN, WASTE,AND VENT PATTERNS. SCHEDULE 40 CAST IRON PIPING SHALL BE PROVIDEDFOR ALL WASTE AND VENT PIPING WITHIN A RETURN OR SUPPLY AIR PLENUM.

WATER PIPING: ABOVE GROUND: PROVIDE TYPE "L" HARD DRAWN COPPERWITH WROUGHT COPPER FITTINGS JOINED WITH LEAD FREE SOLDER. CROSSLINKED, HIGH DENSITY POLYETHYLENE (PEX) OR CPVC IS ACCEPTABLE AS ANAPPROVED ALTERNATE WHERE ALLOWED BY CODE, APPROVED BY THEOWNER, AND ALLOWED BY THE AUTHORITY HAVING JURISDICTION ANDINSTALLED PER MANUFACTURER REQUIREMENTS. BELOW GROUND: PROVIDETYPE "K" SOFT ANNEALED COPPER WITH NO SOLDERED JOINTS. WHEREALTERNATES SUCH AS PEX OR CPVC IS USED THE OWNER MUST SPECIFICALLYAGREE TO IT IN WRITING. WHERE THERE IS A PLENUM CARE MUST BE TAKENTO ENSURE THE INSTALLATION UTILIZES PLENUM RATED AND ACCEPTEDMATERIALS AND INSTALLATION METHODS UTILIZE ONLY PLENUM RATEDMATERIALS. WHEN USING PEX PROVIDE COLOR CODING BY USING BLUE FORCOLD WATER AND RED FOR HOT WATER PIPING.

INDIRECT DRAINS: PROVIDE TYPE "L" COPPER WITH WROUGHT COPPERFITTINGS JOINED WITH 95/5 TIN-ANTIMONY OR LEAD FREE SOLDER. WHENSIZE ALLOWS PROVIDE DWV TYPE FITTINGS. PROVIDE LINES FULL SIZE OF ANYEQUIPMENT CONNECTIONS.

NATURAL GAS PIPING: PROVIDE SHUT-OFF VALVE DOWNSTREAM OF AND ASCLOSE AS PRACTICAL TO EACH GAS METER. PROVIDE SCHEDULE 40 BLACKIRON PIPE WITH MALLEABLE IRON FITTINGS. PIPING 2" AND UNDER SHALL HAVESCREWED FITTINGS, 2-1/2" AND LARGER, AND ALL CONCEALED GAS PIPINGSHALL BE WELDED. VALVES UP TO 2" SHALL BE BRASS. PROVIDE DIRT LEG,SHUT-OFF VALVE, PRESSURE REDUCING VALVE, AND UNION AT EACHAPPLIANCE CONNECTION. UNDERGROUND PIPING SHALL BE PROTECTEDAGAINST CORROSION.

STORM DRAINAGE PIPING: HUBLESS CAST IRON SOIL PIPE. PITCH HORIZONTALLEADERS AT 1/8" PER FOOT FALL IN DIRECTION OF FLOW UNLESS OTHERWISENOTED.

2.2 MATERIALS: CAST IRON SOIL PIPE AND FITTINGS:

FOR COPPER PIPING, PROVIDE WROUGHT COPPER OR DWV TYPE FITTINGSFOR THE APPROPRIATE PIPING SYSTEM. ALL EXPOSED PIPING IN KITCHENS ANDOTHER FOOD PREPARATION AREAS SHALL BE COPPER.

2.3 VALVES: GATE VALVES: EQUAL TO WATTS GV SERIES, BRONZE, 200-PSIWOG. GLOBE VALVES: EQUAL TO WATTS GLV SERIES, BRONZE, 200-PSI WOG.BALL VALVES: EQUAL TO WATTS B-600 SERIES, STANDARD PORT, BRONZE. 1/4"- 2" VALVES SHALL BE 600 PSI WOG. 2-1/2" - 4" SHALL BE 400 PSI WOG.

2.4 FLASHING: WHERE PIPES OF THIS SECTION PASS THROUGH THE ROOF,FLASH WITH SEMCO #1100-4 SEAMLESS 4 LB. FLASHING, WITH STEELREINFORCED "VARI-PITCH" BOOT AND CAST IRON COUNTER FLASHINGSLEEVE.

2.5 PIPE HANGERS:

WATER PIPING: PROVIDE FEE AND MASON #212 SPLIT RING HANGERS WITHSUPPORTING RODS. PROVIDE SEMCO "TRISOLATORS".

SOIL AND WASTE PIPING: PROVIDE FEE AND MASON #212 ADJUSTABLE RINGHANGERS WITH SUPPORTING RODS. USE FEE AND MASON #212 RISERCLAMPS AS REQUIRED.

2.6 CLEANOUTS: ZURN Z-1400 "LEVEL-TROL" ADJUSTABLE FLOOR CLEANOUT,DURA-COATED CAST IRON BODY, WITH GAS AND WATERTIGHT ABS TAPEREDTHREAD PLUG, AND ROUND SCORIATED SECURED TOP ADJUSTABLE TO THEFINISHED FLOOR. FINISHED FLOORS: PROVIDE ZURN ZN-1400 WITHAPPROPRIATE SUFFIX FOR FLOOR FINISH. FLOORS WITH WATERPROOFINGMEMBRANE: PROVIDE "FLUSH-WITH-FLOOR" TYPE CLEANOUTS, WITHADJUSTABLE WATERTIGHT COVERS AND INTEGRAL ANCHORING FLANGE WITHCLAMPING COLLAR. FINISHED WALLS: PROVIDE ZURN ZS-1469 WITH STAINLESSSTEEL ACCESS PLATE AND SCREW.

2.7 TRAPS: FOR LAVATORIES AND SINKS, EXCEPT SERVICE SINKS, PROVIDE LOSANGELES PATTERN CAST BRASS TRAPS WITH BRASS NUTS.

2.8 WATER HAMMER ARRESTORS: PROVIDE WHERE REQUIRED BY CODE.

2.9 FIXTURES AND EQUIPMENT: PROVIDE PLUMBING FIXTURES, TRIM, ANDEQUIPMENT AS INDICATED ON THE PLUMBING PLANS.

2.10 INSULATION: INSULATE HOT, COLD, AND RECIRCULATED HOT WATERPIPING FROM SUPPLYING LOCATION/DEVICE TO THE TERMINATION OF THEWATER FIXTURE SUPPLY PIPE WITH A MINIMUM OF 1-IN. THICK FIBERGLASSINSULATION WITH PLENUM RATED JACKET. INSULATION SHALL BE EQUAL TOJOHNS MANVILLE MICO-LOK, WITH A MAXIMUM CONDUCTIVITY OF 0.27 BTUPER IN/HR * SF * degF. COLD WATER PIPING INSULATION SHALL HAVE VAPORBARRIER. AT ALL HANGER AND SUPPORT LOCATIONS, PROVIDE 8-IN. LONG,20 GAUGE GALVANIZED IRON INSULATION GUARDS. INSULATION AT THESELOCATIONS SHALL BE RIGID. IECC TABLE 403.11.3

PROTECT EXPOSED PIPING FOR ALL ADA ACCESSIBLE FIXTURES WITHINSULATION EQUAL TO TRU BRO.

STORM DRAINAGE PIPING SHALL BE INSULATED WITH 1-1/2" THICK FIBERGLASSINSULATION WITH VAPOR BARRIER AND PLENUM RATED PVC JACKET.INSULATION SYSTEM SHALL BE EQUAL TO JOHNS MANVILLE MICRO-LOK, WITHZESTON PVC JACKETING, 30 MIL THICKNESS. VAPOR BARRIER SHALL BEPROVIDED WITH A MASTIC COMPATIBLE WITH PVC, AND TWO LAYERS OFHI-LO TEMP INSULATION INSERTS SHALL BE UTILIZED TO MAINTAIN THEINTEGRITY OF THE VAPOR BARRIER. INSERTS AND JACKET SHALL MEET ASTME84 FOR MAXIMUM FLAME SPREAD AND SMOKE DEVELOPED RATING OF25/50. EXPOSED VERTICAL STORM DRAINAGE PIPING SHALL NOT BEINSULATED.

2.11 SLEEVES: WHERE PIPES PASS THROUGH CONCRETE, PROVIDE "SPERZEL"RUSTPROOF "CRETE-SLEEVE" OF THE SIZE REQUIRED. WHERE PIPES PASSTHROUGH FIRE RATED PARTITIONS AS DESIGNATED ON THE ARCHITECTURALPLANS, PROVIDE FIRE SEALS AROUND PIPES, WHICH ARE EITHER UL LISTED ORFM APPROVED.

2.12 OTHER MATERIALS: PROVIDE OTHER MATERIALS NOT SPECIFICALLYDESCRIBED BUT REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, ASSELECTED BY THE CONTRACTOR SUBJECT TO THE APPROVAL OF THEARCHITECT.

PART 3 - EXECUTION

3.1 SURFACE CONDITIONS: EXAMINE THE AREAS AND CONDITIONS UNDERWHICH WORK OF THIS SECTION WILL BE PERFORMED. CORRECTCONDITIONS DETRIMENTAL TO TIMELY AND PROPER COMPLETION OF THEWORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARECORRECTED.

3.2 INSTALLATION OF PIPING AND EQUIPMENT:

PROCEED AS RAPIDLY AS THE BUILDING CONSTRUCTION WILL PERMIT.THOROUGHLY CLEAN ITEMS BEFORE INSTALLATION. CAP PIPE OPENINGS TOEXCLUDE DIRT UNTIL FIXTURES ARE INSTALLED AND FINAL CONNECTIONSHAVE BEEN MADE. CUT PIPE ACCURATELY, AND WORK INTO PLACE WITHOUTSPRINGING OR FORCING, PROPERLY CLEARING WINDOWS, DOORS, ANDOTHER OPENINGS. EXCESSIVE CUTTING OR OTHER WEAKENING OF THEBUILDING WILL NOT BE PERMITTED. SHOW NO TOOL MARKS OR THREADS ONEXPOSED PLATED, POLISHED, OR ENAMELED CONNECTIONS FROM FIXTURES.TAPE ALL FINISHED SURFACES TO PREVENT DAMAGE DURINGCONSTRUCTION. MAKE CHANGES IN DIRECTION WITH FITTINGS; MAKECHANGES IN MAIN SIZES WITH ECCENTRIC REDUCING FITTINGS. UNLESSOTHERWISE NOTED, INSTALL WATER SUPPLY AND RETURN PIPING WITH FLATSIDE OF ECCENTRIC FITTINGS FACING UP. RUN HORIZONTAL SANITARYPIPING AT A UNIFORM GRADE OF 1/4" PER FOOT, UNLESS OTHERWISENOTED. RUN HORIZONTAL WATER PIPING WITH AN ADEQUATE PITCHUPWARDS IN DIRECTION OF FLOW TO ALLOW COMPLETE DRAINAGE.PROVIDE SUFFICIENT SWING JOINTS, BALL JOINTS, EXPANSION LOOPS, ANDDEVICES NECESSARY FOR A FLEXIBLE PIPING SYSTEM, EVEN IF NOTSPECIFICALLY SHOWN ON THE DRAWINGS. SECURELY BOLT ALL EQUIPMENT,ISOLATORS, HANGERS, AND SIMILAR ITEMS IN PLACE. SUPPORT EACH ITEMINDEPENDENTLY FROM THE STRUCTURE. DO NOT USE WIRE FOR HANGINGOR STRAPPING PIPES. PROVIDE COMPLETE DIELECTRIC ISOLATION BETWEENFERROUS AND NONFERROUS METALS. FOR INSULATED PIPE, PROVIDE SLEEVESOF ADEQUATE SIZE TO ACCOMMODATE THE FULL THICKNESS OF PIPECOVERING, WITH CLEARANCE FOR PACKING AND CAULKING. CAULK THESPACE BETWEEN SLEEVE AND PIPE OR PIPE COVERING, USING ANON-COMBUSTIBLE, PERMANENTLY PLASTIC, WATERPROOF, NON-STAININGCOMPOUND WHICH LEAVES A SMOOTH FINISHED APPEARANCE, OR PACKWITH NON-COMBUSTIBLE, NON-ASBESTOS COTTON, ROPE, OR FIBERGLASSTO WITHIN 1/2" OF BOTH WALL FACES, AND PROVIDE THE WATERPROOFCOMPOUND DESCRIBED ABOVE.

3.3 FINISH AND ESCUTCHEONS: SMOOTH UP ROUGH EDGES AROUNDSLEEVES WITH PLASTER OR SPACKLING COMPOUND. PROVIDE 1" WIDECHROME OR NICKEL PLATED ESCUTCHEONS ON ALL PIPES EXPOSED TO VIEWWHERE PASSING THROUGH WALLS, FLOORS, PARTITIONS, CEILINGS, ORSIMILAR LOCATIONS. SIZE THE ESCUTCHEONS TO FIT PIPE AND COVERING.HOLD ESCUTCHEONS IN PLACE WITH SET SCREW.

3.4 CLEANOUTS: SECURE THE ARCHITECT'S APPROVAL OF LOCATIONS FORCLEANOUTS IN FINISHED AREAS PRIOR TO INSTALLATION. PROVIDECLEANOUTS OF SAME NOMINAL SIZE AS THE PIPES THEY SERVE; EXCEPTWHERE CLEANOUTS ARE REQUIRED IN PIPES LARGER THAN 4", PROVIDE 4"CLEANOUTS. MAKE CLEANOUTS ACCESSIBLE. AFTER PRESSURE TESTS AREMADE AND APPROVED, THOROUGHLY GRAPHITE THE CLEANOUT THREADS.PROVIDE CLEANOUTS IN ALL LOCATIONS (NOT NECESSARILY INDICATED ONDRAWINGS) REQUIRED BY THE APPLICABLE CODES.

3.5 VALVES: PROVIDE VALVES IN DOMESTIC WATER SUPPLY SYSTEMS. LOCATEAND ARRANGE SO AS TO GIVE COMPLETE REGULATION OF FIXTURES.PROVIDE VALVES IN AT LEAST THE FOLLOWING LOCATIONS: IN BRANCHESAND/OR HEADERS OF WATER PIPING SERVING A GROUP OF FIXTURES; FORSHUTOFF OF BRANCH MAINS; FOR FLUSHING AND STERILIZING THE SYSTEM;WHERE SHOWN ON THE DRAWINGS. LOCATE VALVES FOR EASY ACCESSIBILITYAND MAINTENANCE

3.6 WATER HAMMER ARRESTORS: PROVIDE WATER HAMMER ARRESTORS ONHOT WATER LINES AND COLD WATER LINES. INSTALL IN UPRIGHT POSITION ATALL QUICK CLOSING VALVES, SOLENOIDS, ISOLATED PLUMBING FIXTURES,AND SUPPLY HEADERS AT PLUMBING FIXTURE GROUPS. LOCATE AND SIZE INACCORDANCE WITH THE PLUMBING AND DRAINAGE INSTITUTE STANDARDWH-201. INSTALL WATER HAMMER ARRESTORS BEHIND ACCESS PANELS.

3.7 BACKFLOW PREVENTION: PROTECT PLUMBING FIXTURES AND FAUCETSAGAINST POSSIBLE BACK-SIPHONAGE. ARRANGE FOR TESTING OF BACKFLOWDEVICES AS REQUIRED BY THE GOVERNMENTAL AGENCY HAVINGJURISDICTION.

3.8 PLUMBING FIXTURE INSTALLATION: SET FIXTURES LEVEL AND IN PROPERALIGNMENT WITH RESPECT TO WALLS AND FLOORS AND WITH FIXTURESEQUALLY SPACED. PROVIDE SUPPLIES IN PROPER ALIGNMENT WITH FIXTURESAND WITH EACH OTHER. PROVIDE FLUSH VALVES IN ALIGNMENT WITH THEFIXTURE, WITHOUT VERTICAL OR HORIZONTAL OFFSETS. GROUT WALL ANDFLOOR MOUNTED FIXTURES WATERTIGHT WHERE THE FIXTURES ARE INCONTACT WITH WALLS AND FLOORS.

3.9 DISINFECTION OF POTABLE WATER POTABLE WATER SYSTEMS SHALL BEPURGED OF DELETERIOUS MATTER AN DISINFECTED PRIOR TO UTILIZATION.THE METHOD TO BE FOLLOWED SHALL BE THAT PRESCRIBED BY THE HEALTHAUTHORITY OR WATER PRUVEYOR HAVING JURISDICTION.

3.10 OTHER TESTING AND ADJUSTING: PROVIDE PERSONNEL ANDEQUIPMENT, AND ARRANGE FOR AND PAY THE COSTS OF ALL REQUIREDTESTS AND INSPECTIONS REQUIRED BY GOVERNMENTAL AGENCIES HAVINGJURISDICTION. WHERE TESTS SHOW MATERIALS OR WORKMANSHIP TO BEDEFICIENT, REPLACE OR REPAIR AS NECESSARY, AND REPEAT THE TESTS UNTILTHE SPECIFIED STANDARDS ARE ACHIEVED. ADJUST THE SYSTEM TO OPTIMUMSTANDARDS OF OPERATION.

CODE COMPLIANCE STATEMENTTHIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES:

· INTERNATIONAL PLUMBING CODE : 2018

· INTERNATIONAL ENERGY CONSERVATION CODE (IECC) : 2018

SCALE: NONE

WATER HEATER DETAIL1P0.0

ET1

DIELECTRICUNION (TYP.)

3/8" THREADED ROD TOSTRUCTURE ABOVE, DO

NOT PENETRATE PAN.(TYPICAL OF 4)

3/4"HWTO FIXTURES

3/4"CW

26 GAGE GALV. DRAINPAN, 4" DEEP SOLDEREDWATERTIGHT.

UNISTRUT P1000SUPPORT BELOW PAN,SPOT-WELD TO PAN.(TYP. TWO PLACES)

3/4" RELIEF VALVEDISCHARGE TO AIR GAP

AT FLOOR DRAIN

3/4"PAN DISCHARGE.ROUTE TO AIR GAP AT

FLOOR DRAIN

ASME P&TRELIEF VALVE

WH1

BALL VALVE

VR

INSTALL VACUUMRELIEF VALVE

PROVIDE HEAT TRAPS PERCODE.

1/2"HWC

CHECK VALVE1

CP

SCOPE OF WORK:NEW ELEMENTS MASSAGE.NEW PLUMBING FIXTURES THROUGHOUT.

PLUMBING FIXTURE SCHEDULE

MARK(S)

WH-1

ET-1

CP-1

WC

LW

FD

EWC

MS

KS

HS

DESCRIPTION

WATER HEATERS, EXPANSION TANKS, RECIRCULATION PUMPS

WATER HEATER

EXPANSION TANK

RECIRCULATION PUMP

TOILETS AND URINALS

WATER CLOSET / ADA

LAVATORIES

LAVATORY, WALL MOUNT

FLOOR DRAINS & SINKS, TRENCH DRAINS, PRIMERS

FLOOR DRAIN

DRINKING FOUNTAINS

DRINKING FOUNTAIN

SERVICE SINKS

MOP SINK

SINKS

KITCHEN SINK

HAND SINK

MANUFACTURER / MODEL NO.

State Model PCE20 10MSA

State Model ETC-2X

Taco Model 006

Kohler K-3713

Kohler K-1722

Zurn ZB-1400

Elkay Model EMABFTL8WSSK EZH2O

Fiat model TTB 2424

SUPPLIED BY OWNER THRU MILLWORKCONTRACT, INSTALLED BY GC

SUPPLIED BY OWNER THRU MILLWORKCONTRACT, INSTALLED BY GC

CW

3/4"

3/4"

3/4"

1/2"

1/2"

-

1/2"

1/2"

1/2"

1/2"

HW

3/4"

-

-

-

1/2"

-

-

1/2"

1/2"

1/2"

WASTE

-

-

-

3"

1-1/2"

2"

1-1/2"

2"

1-1/2"

1-1/2"

VENT

-

-

-

2"

1-1/2"

1-1/2"

1-1/2"

1-1/2"

1-1/2"

1-1/2"

REMARKS

4.5 KW single element (208v/1ph), 20 gallon, 22"Ø

1.96 gallon, 150 PSIG, 210ºF rated, NSF bladder, 5 yr. warranty

Cartridge circulator. Balance to provide 2.5 GPM against 7 feet of H20. Time clock to control during occupied hours.Provide Taco temperature controlled aquastat to control pump.

Elongated bowl, 1/2"CW supply, ADA Compliant

Kohler K-97282-4install Conbraco MVD temperature limiting device set to 110 degrees below sink.

Deep seal trap, round top, medium duty grate. Install "waterless" trap primerequal to Proset trap guard with elastomeric memory material in all floordrains. Follow all Manufacturer instructions for installation of the trap guard.

Self-contained wall hung, 2-station drinking fountain, with bottle filler.

24" x 24" terrazzo neocorner floor mount sink,Fiat model 830AA utility faucet w/ vacuum breaker and pail hookdeep seal trap, acid-resist interior and grate, cast iron

FAUCET SUPPLIED BY OWNER THRU MILLWORK, INSTALLED BY GC

FAUCET SUPPLIED BY OWNER THRU MILLWORK, INSTALLED BY GCinstall Conbraco MVD temperature limiting device set to 110 degrees below sink.

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014FX: 303.362.7361

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

JPT

SCF

09.30.2021

KVA21-145/ETM2016

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

PROFESS I ONAL ENGI N EER

87066L I C E N S E D

JOHN TINSLEY

S T A T E O F T E X A S

FIRM NUMBER: 7684kVA Consulting

19600 E Parker Square Dr., B100, Parker, CO 80134(303) 646-4770 Direct | [email protected]

TEN

AN

T FI

NIS

H F

OR

ELE

ME

NTS

MA

SS

AG

ES

AN

AN

TON

IO17

038

FIE

STA

TE

XA

S D

RIV

ES

UIT

E 1

08S

AN

AN

TON

IO, T

X 7

8256

P0.0PLUMBING SPECIFICATIONS

PLUMBING GENERAL NOTES1. HOT WATER RECIRCULATION LINES MUST CONNECT A MAXIMUM OF

6" FROM HOT WATER STUB-IN POINTS FOR FIXTURES PER IECCREQUIREMENTS.

PLUMBING SHEET NOTES1. CONNECT NEW COLD WATER TO EXISTING COLD WATER INTO

SPACE. FIELD VERIFY EXISTING CONDITIONS, FINAL POINTS OFCONNECTION AND LENGTHS OF RUNS PRIOR TO ANY WORK.

2. CONNECT NEW SANITARY SEWER TO EXISTING SANITARY SEWER INSPACE. FIELD VERIFY EXISTING CONDITIONS, FINAL POINTS OFCONNECTION, LENGTHS OF RUNS, INVERT AND DIRECTION OFFLOW PRIOR TO ANY WORK.

3. PROVIDE NEW VENT TO ROOF IF NONE ARE EXISTING. FIELD VERIFYEXISTING CONDITIONS, FINAL POINTS OF CONNECTION ANDLENGTHS OF RUNS PRIOR TO ANY WORK.

4. CONNECT COLD WATER TO REFRIGERATOR PER MANUFACTURERREQUIREMENTS.

5. PROVIDE WALL CLEANOUT AT LOCATION TO BE FIELD VERIFIED.

#

SCALE:

2P1.0

WASTE/VENT ISOMETRICNTS

Was

her

Dry

er

RE

FRIG

.

SCALE:

1P1.0

PLUMBING PLAN1/4"=1'-0"

WB

KS

LW WC

MS

WH-1

HS

EWC

1 1"

1"

1"

1"

1"3/4"

3/4"

SSSS

SSSS

SS

SS

1/2"

2

2

5

3/4"

1/2"

1/2"

1/2"

1/2"

3"

3"

2"

3"

3/4"

3/4"

SS2"

SS

SS

SS

SS

SS

V

WC

V LW

VHSSS

VKS

2

2"

3"

3"

3"

2"

2

SS

SS

VMS

V

WB

EWC

V

V

V

V

V

V

V

V

V

V

V

V

V

V

V

V

V

V

V

V

V

3

3"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"3"

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014FX: 303.362.7361

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

JPT

SCF

09.30.2021

KVA21-145/ETM2016

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

PROFESS I ONAL ENGI N EER

87066L I C E N S E D

JOHN TINSLEY

S T A T E O F T E X A S

FIRM NUMBER: 7684kVA Consulting

19600 E Parker Square Dr., B100, Parker, CO 80134(303) 646-4770 Direct | [email protected]

TEN

AN

T FI

NIS

H F

OR

ELE

ME

NTS

MA

SS

AG

ES

AN

AN

TON

IO17

038

FIE

STA

TE

XA

S D

RIV

ES

UIT

E 1

08S

AN

AN

TON

IO, T

X 7

8256

P1.0PLUMBING PLAN

ONE LINE DIAGRAM GENERAL NOTES:

1. E.C. TO FIELD VERIFY EXISTING CONDITIONS

2. ALL EQUIPMENT IS EXISTING UNLESS NOTED AS NEW (N).

3. ALL EXTERIOR EQUIPMENT TO BE WEATHERPROOF

4. FIELD VERIFY INSTALLATION REQUIREMENTS WITH UTILITY CO. PRIOR TOANY ROUGH-IN.

5. SERVICE EQUIPMENT SHALL BE LEGIBLY LABELED IN THE FIELD, INACCORDANCE WITH THE NEC 110.24 (A):

5.1. MAXIMUM AVAILABLE FAULT CURRENT.5.2. THE DATE THE FAULT CURRENT CALCULATION WAS PERFORMED.5.3. THE LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND

THE ENVIRONMENT INVOLVED.

SCALE:

1E0.0

ONE-LINE DIAGRAMNONE

FIRE ALARM SYSTEM NOTESFIRE ALARM SYSTEM IS TO BE DESIGN/BUILD BY THECONTRACTOR.

TTB TELEPHONE TERMINAL BOARD

#

D

EMERGENCY FIXTURE - SHADED

SINGLE POLE SWITCH, OR #-POLE

or COMBO EXIT - SEE SCHEDULE

EXIT SIGN - SHADED INDICATES FACE

DIMMER SWITCH

AFF ABOVE FINISH FLOOR

GROUNDED DUPLEX RECEPTACLE FLOOR/CEILING MOUNTED TELEPHONE OUTLET

X-##

J

TO

T

K

S DUCT FIRE DETECTOR

ABBREVIATIONS

EWC

RECESSED FLUORESCENT LIGHT FIXTURE

SURFACE MOUNTED FLUORESCENT FIXTURE

WALLWASHER or ADJUSTABLE DOWNLIGHT

CEILING FIXTURE

CCTE.C.

ACWP

EFGFI

APPEAR NEXT TO DEVICES)(ARROWS NOT USED IF CIRCUIT NUMBERS CIRCUIT '##' HOMERUN TO PANEL 'X'

PORCELAIN LAMP HOLDER

TRANSFORMER

S

ABOVE COUNTER - VERIFY HEIGHT

GROUND FAULT INTERRUPTING

CIRCUITELECTRICAL CONTRACTOR

WEATHER PROOF

EXHAUST FANELECTRIC WATER COOLER

SPEAKER

FAA

WALL MOUNTED JUNCTION BOX

ELECTRICAL PANEL BOARD

THERMAL OVERLOAD SWITCH

EQUIPMENT DISCONNECT SWITCH

EQUIPMENT FUSED DISCONNECT SWITCH

J

S

SPECIAL PURPOSE RECEPTACLE

FLOOR/CEILING MOUNTED RECEPTACLE

GROUNDED QUADRAPLEX RECEPTACLE

JUNCTION BOX

FACP

FIRE ALARM REMOTE ANNUNICATOR

S-SMOKE, T-HEAT DETECTOR

PANEL

TELEPHONE/DATA OUTLET, PROJECT STANDARD

FIRE ALARM PANEL

TELEPHONE OUTLET

DATA OUTLET

POWER AND LIGHTING

ELECTRICAL LEGEND

LOW VOLTAGE SYSTEMS

GROUNDED SWITCHED DUPLEX RECEPTACLE

GROUNDED SPLIT-WIRED RECEPTACLE FLOOR/CEILING MOUNTED DATA OUTLET

TELEPHONE TERMINAL BOARD

REFERENCE SYMBOLS

FEEDER - SEE SCHEDULE

KEYED NOTE

XFMR

kVA

TRANSFORMER WITH GROUNDING ANDOVERCURRENT DEVICES SEETRANSFORMER SCHEDULE

#/W

XX

#

AG ABOVE COUNTER GFI - VERIFY HEIGHT

T

##

EQUIPMENT - SEE SCHEDULE#

BATTERY PACK EMERGENCY LIGHT

(ER)

(E)

EXISTING TO BE RELOCATED

EXISTING TO REMAIN

(R) RELOCATE/RELOCATED LOCATION

(EX) EXISTING TO BE REMOVED

AHJ AUTHORITY HAVING JURISDICTION

AFI ARC FAULT INTERRUPTING

NOTE: NOT ALL ITEMS APPEAR ON DRAWINGS. SYMBOLS MAY DIFFER FROM EXISTINGAND DEMO WORK OR DEVICES REFERENCED FROM DRAWINGS BY OTHERS.

CATV/MONITOR A/V OUTLET

GENERAL PROJECT NOTESNOTE: SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL CONSTRUCTION REQUIREMENTS

1. THE CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A COMPLETE,OPERATIONAL AND PROPERLY FUNCTIONING ELECTRICAL SYSTEM

2. MATERIALS AND INSTALLATION SHALL COMPLY WITH CODES, LAWS AND ORDINANCES OF FEDERAL,STATE AND LOCAL GOVERNING BODIES HAVING JURISDICTION.

3. MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY U.L., ETL, CSA OR ANOTHERRECOGNIZED TESTING LAB. ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. SHALL BE NEW, UNLESSSPECIFICALLY INDICATED AS EXISTING TO BE REUSED.

4. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO GOVERNMENTAL AGENCIES AND UTILITYCOMPANIES SHOP DRAWINGS REQUIRED BY THESE AGENCIES FOR APPROVAL. THE CONTRACTOR SHALLSECURE AND PAY FOR ALL PERMITS, GOVERNMENTAL FEES, TAXES AND LICENSES NECESSARY FOR THEPROPER EXECUTION AND COMPLETION OF THE ELECTRICAL WORK. THIS CONTRACTOR SHALL SECUREAND PAY ALL FEES AND PERMITS PERTAINING TO THIS CONTRACT, SHALL BE RESPONSIBLE FOR WORKER'SIDENTIFICATION AND BADGING, SAFETY, AND LIABILITY INSURANCE. PROVIDE BARRICADES, WARNINGSIGNS, AND TRASH REMOVAL FOR THE SAFETY OF THE WORKERS UNDER THIS CONTRACTOR'S EMPLOY.

5. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER/OWNER OF ANY MATERIALS ORAPPARATUS BELIEVED TO BE INADEQUATE, UNSUITABLE, IN VIOLATION OF LAWS, ORDINANCES, RULESOR REGULATIONS OF AUTHORITIES HAVING JURISDICTION.

6. THE CONTRACTOR SHALL PREPARE THE DOCUMENTS, INCLUDING DRAWINGS, REQUIRED TO OBTAINAPPROVAL OF THE EQUIPMENT AND LOCATIONS OF THE DEVICES THAT COMPRISE THE BUILDING FIREALARM LIFE SAFETY SYSTEM. THE DRAWINGS AND CUT SHEETS SHALL BE PROVIDED TO A PROFESSIONALENGINEER FOR REVIEW AND APPROVAL. THE APPROVED DRAWINGS WILL BE STAMPED, SIGNED ANDRETURNED TO E.C. TO SUBMIT TO THE BUILDING DEPARTMENT.

7. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS, VISIT THE SITE, ANDTHOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS, LOCAL JURISDICTIONAL CODESAND REQUIREMENTS, AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO DO SO WILLNOT RELIEVE THE CONTRACTOR OF THE OBLIGATIONS OF THE CONTRACT. SUBMISSION OF PROPOSALIN CONNECTION WITH THIS WORK SHALL IMPLY THAT THE BIDDER HAS EXAMINED THE JOB SITE. NOEXTRA CHARGE WILL BE ALLOWED FOR CHANGES AS A RESULT FROM FAILURE TO EXAMINE THE JOB SITE.

8. THE CONTRACTOR SHALL PROVIDE TEMPORARY POWER AND WIRING FOR THE PERFORMANCE OF ALLTRADES, FOR THE ENTIRE PERIOD OF CONSTRUCTION AND SHALL REMOVE ALL TEMPORARY WIRING ATTHE COMPLETION OF CONSTRUCTION.

9. THE EXISTING POWER, SIGNAL AND COMMUNICATION SYSTEMS ARE TO REMAIN IN SERVICE TOPROVIDE FOR THE OWNER'S FUNCTION. SHOULD IT BECOME NECESSARY TO SHUT-DOWN ANY SYSTEMOR PORTION OF A SYSTEM, APPROVAL IN WRITING MUST BE OBTAINED FROM THE OWNER AND SHALLONLY APPLY FOR THE PERIOD AND TIME AGREED UPON. THE BID IS TO INCLUDE THE COST OF ANYTEMPORARY WIRING AND PREMIUM TIME REQUIRED FOR THE SHUTDOWN.

10. ALL MATERIALS AND EQUIPMENT SHALL BE ERECTED, INSTALLED, CONNECTED, CLEANED, ADJUSTED,TESTED, CONDITIONED, AND PLACED IN SERVICE IN ACCORDANCE WITH THE MANUFACTURER'SDIRECTIONS AND RECOMMENDATIONS.

11. ALL CUTTING, DRILLING AND PATCHING OF MASONRY, STEEL OR IRON WORK BELONGING TO THEBUILDING MUST BE DONE BY THIS CONTRACTOR IN ORDER THAT HIS WORK MAY BE PROPERLYINSTALLED, BUT UNDER NO CONDITIONS MAY STRUCTURAL WORK BE CUT, EXCEPT AT THE DIRECTIONOF THE ARCHITECT-DESIGNER OR THEIR REPRESENTATIVE.

12. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OFELECTRICAL FIXTURES AND ELECTRICAL DEVICES. MOUNTING HEIGHTS SHALL CONFORM TOADA/ICC/ANSI STANDARDS.

13. ALL WORK REQUIRED FOR THE INSTALLATION AS SHOWN ON DRAWINGS INCLUDING LABOR,EQUIPMENT AND MATERIALS SHALL BE IN STRICT COMPLIANCE WITH THE BUILDING STANDARDS.

14. PROVIDE COMPLETE METAL RACEWAY SYSTEMS AND ENCLOSURES FOR ALL WIRING THROUGHOUT THEEXTENT OF THE REQUIRED SYSTEM.

15. ALL TELE/ DATA BOXES SHALL BE PROVIDED WITH A 1/2” CONDUIT AND BUSHING WITH PULL STRINGRUN 6” ABOVE FINISHED CEILING OR CEILING GRID. ELECTRICAL METALLIC TUBING (EMT) SHALL BE USEDFOR ALL WALL OUTLETS & TELEPHONE WIRING RUNNING BELOW RAISED FLOOR OR ABOVE HARDCEILINGS.

16. ALL RECEPTACLES NOTED AS ISOLATED GROUND (IG) OR DEDICATED OR CIRCUITED AS DEDICATEDSHALL BE PROVIDED WITH A DEDICATED GROUND AND NEUTRAL. ALL RECEPTACLES IN BATHROOMS,KITCHENS, ROOFTOPS, OUTDOORS, AND WITHIN 6FT. OF A SINK SHALL BE GFCI (OR SERVED BY A GFICIRCUIT BREAKER) PER NEC 210.8(B). THE E.C. SHALL PROVIDE GFCI OUTLETS (OR CIRCUIT BREAKERS) INALL LOCATIONS REQUIRED BY THE NEC. ALL RECEPTACLES IN DWELLING UNITS, GUEST ROOMS, ANDCHILD CARE FACILITIES (AS SPECIFIED BY ARTICLE 406 OF THE NEC) SHALL BE LISTED ASTAMPER-RESISTANT RECEPTACLES.

17. MINIMUM CONDUIT SIZE SHALL BE 3/4" UNLESS OTHERWISE INDICATED. CONDUITS LARGER THAN 2"DIAMETER OR CONDUITS OF ANY SIZE ROUTED OUTDOORS SHALL BE INTERMEDIATE METAL CONDUIT(IMC)

18. FLEXIBLE CONDUIT CONNECTIONS TO RECESSED LIGHTING FIXTURES SHALL BE MADE WITH FLEXIBLESTEEL CONDUIT, 3/8 INCH MINIMUM.

19. FINAL CONNECTIONS TO MOTORS SHALL BE MADE WITH LIQUID TIGHT FLEXIBLE STEEL CONDUIT, 1/2INCH MINIMUM.

20. WIRE NO. 8 AND SMALLER INSTALLED IN DRY LOCATIONS SHALL BE TYPE THWN OR THHNTHERMOPLASTIC 600V INSULATED COPPER CONDUCTORS. NO WIRE SMALLER THAN NO.12 SHALL BEUSED FOR LIGHTING OR POWER WIRING. WIRE NO. 8 AND LARGER SHALL BE STRANDED. ALLCONDUCTORS INSTALLED IN EXTERIOR OR WET LOCATIONS SHALL BE TYPE THWN 600V INSULATEDCOPPER CONDUCTORS.

21. ALL NEW CIRCUIT BREAKERS FOR NEW OR EXISTING PANEL BOARDS SHALL MATCH EXISTING OR NEWBUILDING STANDARD PANEL BOARD MANUFACTURER AND BREAKER TYPE. THE CONTRACTOR SHALLPROVIDE NEW ACCURATE AND DETAILED TYPE WRITTEN PANEL DIRECTORIES PER NEC 408.4 FOR ALLNEW OR MODIFIED PANELS. NUMBERED CIRCUITS ARE FOR CONVENIENCE OF DESIGN ONLY. E.C. TOFIELD VERIFY ACTUAL CIRCUIT NUMBERS USED AND CORRECTLY INDICATE ON "AS-BUILT" DRAWINGS.THE E.C. SHALL REMOVE ALL ABANDONED CIRCUITS.

22. PROVIDE #10 FOR BRANCH CIRCUITS OVER 75' AT 120V AND OVER 150' AT 277V. E.C. TO FIELD VERIFYBRANCH CIRCUIT LENGTHS AND SIZE CONDUCTORS FOR VOLTAGE DROP.

23. EACH SWITCH, LIGHT, RECEPTACLE AND ALL OTHER DEVICES SHALL BE PROVIDED AND INSTALLED WITH AGALVANIZED OR SHERARDIZED PRESSED STEEL JUNCTION BOX OF NOT LESS THAN NO. 14 U.S. GAUGESTEEL. CONDUITS SHALL BE FASTENED WITH LOCKNUTS AND BUSHINGS AND ALL UNUSED KNOCKOUTSMUST BE LEFT SEALED. THERE MUST BE SUFFICIENT ROOM FOR WIRES AND BUSHINGS AND DEEP BOXESSHALL BE INSTALLED WHERE REQUIRED. BOXES SHALL BE SECURELY AND ADEQUATELY SUPPORTED.

24. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SPECIAL OUTLET BOXES THAT MAY BE REQUIRED TOENCLOSE RECEPTACLES.

25. IN SUSPENDED CEILINGS SUPPORT CONDUIT AND JUNCTION BOXES DIRECT FROM THE STRUCTURALSLAB, DECK, OR FRAMING PROVIDED FOR THAT PURPOSE. LIGHTING BRANCH CIRCUIT CONDUITSSHALL NOT BE CLIPPED TO THE CEILING SUPPORT WIRES OR SPLINE UNLESS THE CEILING SYSTEM HASBEEN SPECIFICALLY DESIGNED FOR THAT PURPOSE.

26. PROVIDE LOCAL DISCONNECT SWITCHES FOR ALL MOTORS (PLENUM APPROVED WHERE REQUIRED).

27. THE E.C. SHALL INCLUDE IN HIS COST THE REMOVAL OF ALL EXISTING ELECTRICAL DEVICES, CONDUITS,FIXTURES AND EQUIPMENT THAT IS NOT TO BE REUSED DISCARD ALL EQUIPMENT AS REQUIRED. E.C.SHALL BE RESPONSIBLE FOR DISCONNECTING PRIMARY SERVICE AND TEMPORARY POWER.

28. PROVIDE WARRANTY GUARANTEED FOR A PERIOD OF ONE YEAR AFTER COMPLETION ANDACCEPTANCE. REPLACE ALL DEFECTIVE WORKMANSHIP, EQUIPMENT AND MATERIALS WITHOUTADDITIONAL CHARGES.

29. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFEKEEPING OF HIS/HER OWN PROPERTY ON THEJOB SITE. THE OWNER OR TENANT ASSUMES NO RESPONSIBILITY FOR PROTECTION OF THISCONTRACTOR'S PROPERTY AGAINST FIRE, THEFT, OR ENVIRONMENTAL CONDITIONS.

30. WHERE CONDUIT, CABLES, DUCTWORK OR PIPING PASSES THROUGH FIRE RATED FLOORS, WALLS, ORPARTITIONS, THE SLEEVES SHALL BE COMPLETELY SEALED WITH A FIRE STOP MATERIAL THAT IS U.L. LISTED(EQUAL TO DOW CORNING) AND ACCEPTED BY THE BUILDING DEPARTMENT AND FIRE DEPARTMENT ASBEING SUITABLE FOR THE SERVICE. THIS MATERIAL SHALL BE INSTALLED IN ACCORDANCE WITH THEMANUFACTURER'S PUBLISHED INSTRUCTIONS IN ORDER TO MAINTAIN THE FIRE RATING OF THEPENETRATED WALL, FLOOR, OR PARTITION. INSTALLATION SHALL BE A THROUGH-PENETRATION FIRESTOPSYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH ASTM AND UL . THE FIRE RATING SHALL MATCHTHE RATING OF THE BARRIER BEING PENETRATED.

31. SUBMIT ONE (1) PDF OR SIX (6) SETS OF SHOP DRAWINGS, CONTROL DIAGRAMS, AND EQUIPMENTCUTS TO THE ENGINEER FOR APPROVAL PRIOR TO STARTING RELATED WORK. SHOP DRAWINGS SHALLINCLUDE MANUFACTURER'S NAMES, CATALOG NUMBERS, CUTS, DIAGRAMS AND OTHER SUCHDESCRIPTIVE DATA AS MAY BE REQUIRED TO IDENTIFY AND REVIEW THE EQUIPMENT. SUBMITTALS SHALLBE IN LOGICAL GROUPS, PARTIAL SUBMITTALS WILL NOT BE REVIEWED.

32. UPON COMPLETION OF CONSTRUCTION, SUPPLY THE ENGINEER WITH ONE COMPLETE SET OF FULLSIZE AS-BUILT DRAWINGS. PROVIDE THE OWNER WITH THREE (3) SETS OF OPERATION ANDMAINTENANCE MANUALS FOR EACH TYPE OF EQUIPMENT INSTALLED.

33. THIS CONTRACTOR SHALL ASSUME ALL ADDED EXPENSES TO ALL TRADES ASSOCIATED WITH THEINSTALLATION OF SUBMITTED AND APPROVED ALTERNATE EQUIPMENT.

34. THE CONTRACTOR SHALL COORDINATE THE LAYOUT OF THE FIRE ROOM WITH ALL OTHER DISCIPLINES,ESPECIALLY THE FIRE ALARM AND FIRE PROTECTION DESIGN-BUILD CONTRACTORS PRIOR TO ANYWORK.

35. IF ANY CHANGES ARE MADE TO ACCOMMODATE FIELD CONDITIONS NOTIFY THE ENGINEERIMMEDIATELY OF WHAT THE CHANGES WERE, THE REASON FOR THE CHANGES, AND THE COSTIMPACTS.

MAIN

LEVE

L FLO

OR P

LAN

Transformer ScheduleOvercurrentProtection480V, 3Ø

20A50A70A125A175A225A350A

Notes: Primary shall be 3-wire and secondary shallbe 4-wire unless noted otherwise. All transformers45kVA and below shall be suspended unless notedotherwise. All transformers over 45kVA shall befloor mounted unless noted otherwise. Primaryand secondary feeders shall be sized per the circuitbreaker size and shall be 3-wire on the primary and4-wire on the secondary. For example all 45kVA480/208V transformers with a 480V primary will befed with a 70/3 on the primary and a 150/4 on thesecondary (the bonding and grounding shall beper NEC 250.30A).

kVA - Ground15 - #830 - #645 - #675 - #2

112.5 - #2150 - 1/0225 - 2/0

OvercurrentProtection208V, 3Ø

50A100A150A250A400A500A800A

Based on NEC:

FEEDER SCHEDULE

3000/W2000/W1600/W1200/W1000/W

800/W750/W600/W500/W400/W350/W300/W250/W225/W200/W175/W150/W125/W110/W100/W90/W80/W70/W60/W50/W40/W30/W20/W

Service Ground Table

150G200G300G500G800G>800G

8[W-500kcmil, 3/0G, 3-1/2"C]6[W-400kcmil, 3/0G, 3"C]5[W-400kcmil, 3/0G, 3"C]4[W-350kcmil, 3/0G, 3"C]3[W-400kcmil, 2/0G, 3"C]3[W-300kcmil, 1/0G, 3"C]3[W-250kcmil, 1/0G, 3"C]2[W-350kcmil, #1G, 3"C]2[W-250kcmil, #2G, 3"C]2[W-3/0, #3G, 2"C]2[W-2/0, #3G, 2"C]W-350kcmil, #4G, 3"CW-250kcmil, #4G, 3"CW-4/0, #4G, 2"CW-3/0, #6G, 2"CW-2/0, #6G, 2"CW-1/0, #6G, 2"CW-1/0, #6G, 2"CW#1, #6G, 1-1/2"CW#1, #6G, 1-1/2"CW#2, #8G, 1-1/4"CW#3, #8G, 1-1/4"CW#4, #8G, 1-1/4"CW#4, #8G, 1-1/4"CW#6, #10G, 1"CW#8, #10G, 1" CW#10, #10G, 3/4"CW#12, #12G, 3/4"C

#6#4#21/02/03/0

Equipment Ground Table

20EG60EG100EG200EG300EG400EG

#12#10#8#6#4#3

Ampacities are based on NEC table 310.15(B)(16) utilizing the 60 degree column up to100 Amps and the 75 degree column above 100 Amps Service ground conductor sizes

are per NEC table 250.66 and equipment ground is per NEC table 250.122.

Based on NEC:

The master electrician shall be responsible for ensuring that no feeders or branch circuitsare installed in a manner or sized in such a way as to violate the NEC.

Where discrepancies occur between the Feeder schedule and the grounding charts, thechart shall overrule the feeder schedule and the NEC shall overrule all schedules.

The service ground chart indicates the minimum service ground based on #G where # isthe ampacity from the chart above, and the equipment ground chart indicates the

minimum equipment grounding conductor size #EG where # is the rating/ setting of theovercurrent device protecting the conductors and equipment.

All conductors shall be COPPER, unless denoted by "AL"

14[W-350kcmil, 3"C]7[W-500kcmil, 400kcmil G, 3-1/2"C]

8[W-250kcmil, 250kcmilG, 3"C]4[W-500kcmil, 250kcmil G, 3-1/2"C]

4[W-350kcmil, 4/0G, 3"C]3[W-400kcmil, 3/0G, 3"C]3[W-350kcmil, 2/0G, 3"C]

2[W-500kcmil, 2/0G, 3-1/2"C]2[W-350kcmil, 1/0G, 3"C]2[W-250kcmil, #1G, 3"C]2[W-4/0, #2G, 2-1/2"C]

W-500kcmil, #2G, 3-1/2"CW-350kcmil, #4G, 3"CW-300kcmil, #4G, 3"C

W-250kcmil, #4G, 2-1/2"CW-4/0, #6G, 2"CW-3/0, #6G, 2"CW-2/0, #6G, 2"CW-2/0, #6G, 2"CW-1/0, #6G, 2"CW-1/0, #6G, 2"C

W#1, #8G, 1-1/2"CW#2, #8G, 1-1/4"CW#2, #8G, 1-1/4"CW#4, #8G, 1-1/4"C

W#6, #8G, 1" CW#8, #10G, 3/4"C

W#10, #10G, 3/4"C

COPPERALUMINUM

This table indicates minimum conductor size for feeders of the ampacity indicated where#/W indicates the ampacity/ numbers of wire. A #S/W indicates no ground.

ALUMINUM COPPER#4#21/03/04/0250

ALUMINUM COPPER#10#8#6#4#2#1

CODE COMPLIANCE STATEMENTTHIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES:· NATIONAL ELECTRIC CODE (NEC) : 2017· INTERNATIONAL ENERGY CONSERVATION CODE (IECC) : 2018

SCOPE OF WORK:NEW ELEMENTS MASSAGE.EXISTING SERVICE TO REMAIN.NEW PANELBOARD TO SPACE FROM EXISTINGSERVICE.NEW POWER AND LIGHTING THROUGHOUT.

PANEL SCHEDULE: PROJECT:LOCATION:JOB NO.:COMMENTS: BUS RATING:MAIN O.C. DEVICE:MOUNTING: CIR

NO.

13579

11131517192123252729313335373941

NOTES:

1.

CIRCUIT

AMPS

202020202020202020202020202020202020505050

CONNECTED LOAD:

Elements Theraputic MassageTenant Space2021-145New Panelboard

BREAKER

POLE

111111111111111111333

PHASE A (VA):PHASE B (VA):PHASE C (VA):

TOTAL LOAD (VA):

200A200A MCBSurface

CONNECTED

LOAD (VA)

900 900 900 900 900 900 900 180 720 900

1200 799 900 900 900 799

3840 3840 3840

13,759 15,723 14,409 43,891

E

NEC DEMAND

FACTOR

1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.25 1.00 1.00 1.00 1.25

1.00 1.00 1.00

DESCRIPTION OF

LOAD SERVED

Massage RoomMassage RoomMassage RoomMassage RoomMassage RoomMassage RoomMassage Room

Reception PrinterReceptionist Desk

Conv. ReceptShow Window

LightingMassage RoomMassage RoomMassage Room

LightingSpareSpareRTU-1RTU-1RTU-1

PHASE

ABCABCABCABCABCABCABC

VOLTAGE L-L:VOLTAGE L-G:SYSTEM: S.C.RMS RATING:

DESCRIPTION OF

LOAD SERVED

TTBITRefrigeratorOfficeMicrowaveWashine MachineDryerDryerSignagePanel ReceptacleRestroomBreak RoomEWCExhaust FansTelevisionsSpareWH-1WH-1CU-1CU-1Bussed Space

DEMAND LOAD:PHASE A (VA):PHASE B (VA):PHASE C (VA):

TOTAL DEMAND LOAD (VA):

2081203Ø, 4-WIRE

22,000 AIC

NEC DEMAND

FACTOR

1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.25 1.00 1.00 1.00 1.00

1.00 1.00 1.00 1.00

13,959 15,851 14,609 44,419

CONNECTED

LOAD (VA)

360 360 750 540

1000 750

1500 1500 1200 180 513 900 360 500 500

2250 2250 1680 1680

123.30

October 7, 2021

Circuit Font Key:Normal: New Load/BreakerBold: New Load/Exist BrkrItalic:Exist Load/Brkr

CIRCUIT

POLE

11111122111111112222

A

BREAKER

AMPS

2020202020203030202020202020202030302525

CIR

NO.

24681012141618202224262830323436384042

FAULT CURRENT CALCULATION TABLE

NOTES:1.2.

3.4.5.

6.

LOCATION (n)1500

2000A SERVICEPANEL E

All Calculations use Bussman "Point-To-Point" Method.Variables:

The E.C. shall report any discrepancies to the Engineer.Aluminum Conductors, MC Cabling, and Series Rated Panels are not allowed.The E.C. shall verify the Available Fault Current from the Electrical Utility and shall report theactual Fault Current available to the Engineer if different from shown. Fault Currents are basedon Utility information or %Z=1.4 if none are provided.The E.C. shall field verify the Feeder Lengths and report any discrepancy to the engineer.Conductor Lengths listed in this table are engineering estimates and are not intended to representactual lengths for bidding or other calculations. The E.C. shall inform the Engineer immediatelyif the actual lengths are less than that listed.

# of RUNSUtility Transformer

41

L=Feeder Length (LF)f(n) = (1.73 x L x F(n-1))/(C x # of runs x Voltage) in Amperes

CONDUCTOR

6003/0

VOLTAGE208208208

C=Conductor "C" Value

L(ft)

5090

C

28,03312,844

f

0.293.53

October 7, 2021

M

0.780.22

M(n) =1 ÷ (1+f(n))F(n)=F(n-1) x M(n)

F 78,20060,61913,373

T

L2PANEL

GRADE LEVEL

200A/3P200A JJN

METERUTILITYM

PANELE

200A/3P200A JJN

UTILITYMETERM

PAD MOUNTED UTILITY1500kVA TRANSFORMER208/120V, 3-PHASE, 4W

200/4

200/4

200/4

4(4-600KCM)

2000A BUSSED GUTTER, 208/120V, 3ɸ,4W, 65KAIC, NEMA 3R

(N)

(N)

(N)

(N)

(N)

(N)

>800G

2000 KRP-C2000A/3P

NG

EXISTINGGROUND PERNEC 250

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014FX: 303.362.7361

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

JPT

SCF

09.30.2021

KVA21-145/ETM2016

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

PROFESS I ONAL ENG I N EER

87066L I C E N S E D

JOHN TINSLEY

ST A T E O F T EX A S

FIRM NUMBER: 7684kVA Consulting

19600 E Parker Square Dr., B100, Parker, CO 80134(303) 646-4770 Direct | [email protected]

TEN

AN

T FI

NIS

H F

OR

ELE

ME

NTS

MA

SS

AG

ES

AN

AN

TON

IO17

038

FIE

STA

TE

XA

S D

RIV

ES

UIT

E 1

08S

AN

AN

TON

IO, T

X 7

8256

E0.0ONE-LINE, NOTES &

SCHEDULES

POWER PLAN KEYED NOTES:

1. SHOW WINDOW - PROVIDE FLUSH MOUNTED DUPLEX OUTLET IN CEILING OR WALLWITHIN 18" MAXIMUM ABOVE STOREFRONT FOR SHOW WINDOW LIGHTING INACCORDANCE WITH NEC 210.62.

2. TELEPHONE BOARD LOCATION (TTB) - THE E.C. SHALL PROVIDE AND INSTALLBACKBOARD, INSTALL TIGHT TO CEILING AND PAINT TO MATCH WALL. PROVIDE 1”CWITH PULL STRING BACK TO THE BUILDING TELEPHONE/ DATA SERVICE ENTRANCE.PROVIDE DEDICATED NEMA 5-20R RECEPTACLE +84"AFF ON TTB AND CIRCUIT ASSHOWN. FIELD VERIFY LOCATION, MOUNTING HEIGHT AND ORIENTATION ANDADDITIONAL REQUIREMENTS WITH TENANT PRIOR TO BID OR ANY WORK.

3. IT EQUIPMENT - PROVIDE DEDICATED CIRCUIT WITH DEDICATED GROUND ANDNEUTRAL CONDUCTOR. FIELD VERIFY FINAL LOCATION, MOUNTING HEIGHT,ELECTRICAL REQUIREMENTS WITH EQUIPMENT PROVIDER PRIOR TO ROUGH-IN.

4. SAW CUT - REMOVE AND REPLACE OF EXISTING CONCRETE SLAB TOACCOMMODATE POWER WIRING AND CONDUITS FOR DEVICES IN FREESTANDINGWALL/MILLWORK. FIELD VERIFY FINAL LOCATION OF DEVICES AND WIRINGREQUIREMENTS. PROVIDE HARD WIRED CONNECTIONS OR GFCI PROTECTED FLOORRECEPTACLE AT THE DISCRETION OF THE OWNER AND EQUIPMENT PROVIDER.FLOOR RECEPTACLES TO BE HUBBEL RF406ALU.

5. WASHING MACHINE - PROVIDE DEDICATED 20A OUTLET WITH DEDICATED GROUNDAND NEUTRAL CONDUCTORS. FIELD VERIFY FINAL LOCATION AND REQUIREMENTSWITH PROVIDER PRIOR TO ROUGH-IN.

6. DRYER - PROVIDE DEDICATED 30A/2P 4-WIRE OUTLET WITH 3#10,#10G, ¾”C. FIELDVERIFY FINAL LOCATION, OUTLET TYPE AND CONFIGURATION AND REQUIREMENTSWITH PROVIDER PRIOR TO ROUGH-IN.

7. PROVIDE (1) 1" CONDUIT FOR POWER AND (3) 1" CONDUITS FOR DATA 24" AFF IN ASTRAIGHT LINE PARALLEL TO THE DESK AS DIMENSIONED ON ARCHITECTURAL PLANS.WIRE INTO OWNER PROVIDED (THRU MILLWORK CONTRACT) LEGRAND DS400DESIGNER GRAY WIREMOLD RACEWAY FROM FLOOR TO UNDERSIDE OF DESK WITH(4) DUPLEX RECEPTACLES AND (6) CAT5E TERMINATED DATA PORTS.

8. TV/MONITOR - PROVIDE POWER AND DATA/CATV JACKS AS REQUIRED IN CEILINGAND PROVIDE RACEWAY TO VIDEO SOURCE. FIELD VERIFY REQUIREMENTS WITHTENANT AND TV PROVIDER. FIELD VERIFY FINAL LOCATION WITH ARCHITECT PRIORTO ANY ROUGH-IN.

9. PROVIDE EATON TRUSBAC15GY OR EQUAL COMBINATION USB-A, USB-C, & DUPLEXRECEPTACLE AT LOCATION INDICATED.

Was

her

Dry

er

RE

FRIG

.

+3'-2"+3'-2"

+2'-0"+3'-2"+3'-2"

+2'-0"

+3'-2" +3'-2"

+2'-0"

+3'-2"+3'-2"

+2'-0"

+3'-2" +3'-2"

+2'-0"

+3'-2"+3'-2"

+2'-0"

+3'-2" +3'-2"

+2'-0"

VV

V

VV

VV

USB

USB

USB

USB

US

B

US

B

USB

USB

USB

USB

USB

TV

TC

+3' - 0"

+3' - 0"

+1' - 6"

+3' - 6"

+3' - 6"

+7' - 0"

+7' - 0"

+1' - 6"+1' -

6"

+1' -

6"

+3' -

6"

+3' -

6"

+9' -

0"

+2' - 6"

+2' - 6"

+2' - 6"

+2' - 6"

+2' - 6"

+2' - 6"

+2' - 6"

+1' - 6"

+1' - 6"

+1' -

6"

+1' -

6"

SCALE:

1E1.0

POWER PLAN1/4"=1'-0"

POWER PLAN GENERAL NOTES:

1. PROVIDE OUTLET WITHIN 25' OF EQUIPMENT IN ACCORDANCE WITH NEC 210-63.PROVIDE WEATHERPROOF GFI OUTLET ON ROOFTOPS WITHIN 25' OF ROOFTOPEQUIPMENT.

2. FIELD VERIFY FINAL LOCATION OF ALL EQUIPMENT WITH PROVIDER PRIOR TOROUGH-IN.

3. ALL RECEPTACLES IN BATHROOMS, KITCHENS, ROOFTOPS, OUTDOORS, AND WITHIN6FT. OF A SINK SHALL BE GFCI (OR SERVED BY A GFI CIRCUIT BREAKER) PER NEC210.8(B). THE E.C. SHALL PROVIDE GFCI OUTLETS (OR CIRCUIT BREAKERS) IN ALLLOCATIONS REQUIRED BY THE NEC.

4. ALL RECEPTACLES IN DWELLING UNITS; GUEST ROOMS; CHILD CARE FACILITIES;PRESCHOOLS AND ELEMENTARY SCHOOLS; OFFICES, CORRIDORS AND WAITINGROOMS IN CLINICS, MEDICAL AND DENTAL OFFICES AND OUTPATIENT FACILITIES;SUBSET OF ASSEMBLY OCCUPANCIES PER 518.2 TO INCLUDE WAITINGTRANSPORTATION, GYMNASIUMS, SKATING RINKS, AND AUDITORIUMS;DORMITORIES - (AS SPECIFIED BY ARTICLE 406.12 OF THE NEC) SHALL BE LISTED ASTAMPER-RESISTANT RECEPTACLES.

5. PROVIDE CONNECTION TO TENANT SIGN. FIELD VERIFY ELECTRICAL REQUIREMENTSAND FINAL LOCATION WITH PROVIDER, TENANT AND LANDLORD. PROVIDEPHOTOCELL ON/TIMECLOCK OFF CONTROLS. PROVIDE ALL COMPONENTSREQUIRED FOR A COMPLETE INSTALLATION.

6. NUMBERS NEXT TO DEVICES REFER TO CIRCUIT DESIGNATION IN PANEL 'E' UNLESSNOTED.

7. ALL TELE/DATA LOCATIONS SHALL INCLUDE 4" SQUARE J-BOX AND 3/4" CONDUIT TOCEILING SPACE. ALL TELEPHONE/DATA CABLE IS TO BE PLENUM RATED WIRE OR SHALLBE INSTALLED IN CONDUIT ABOVE CEILING OR IN WALLS.

8. PROVIDE ALL DEMOLITION WORK AS REQUIRED TO ACCOMMODATE THE NEWWORK AS INDICATED ON THE ELECTRICAL PLANS. FIELD VERIFY EXISTINGCONDITIONS. PROVIDE ANY ADDITIONAL WORK NECESSARY AS REQUIRED TOPRESERVE EXISTING DEVICES AND BRANCH CIRCUIT COMPONENTS TO REMAIN.REFER TO THE ARCHITECTURAL PLANS FOR DEMOLITION SCOPE OF WORK AND VISITTHE SITE PRIOR TO BID TO DETERMINE THE ELECTRICAL SCOPE OF WORK REQUIRED.

9. ALL RECEPTACLE AND SWITCH FACEPLATES TO BE COLORED WHITE PER ELEMENTSMASSAGE STANDARD.

#

121121

47

17

19

1919

15

9

1

9

9

9

3

9

5

9

7

9

13

9

11

9

9

1

3

9

11

13

5

7

1

1 1

3

3

3

5

5 5

7

7

7

9

9 9

13

13 13

11

11

11

6 14,16

5 12

2

3TTB

IT

4

2

6

10

24

24242424

24

EQUIPMENT SCHEDULEKEY

RTU-1

CU-1

CS-1

WH-1

NOTES:1.2.3.

EQUIPMENT

ROOFTOP UNITS6-TONCONDENSING UNIT

CEILING CASSETTE

WATER HEATER

Field verify final location and electrical requirements of all equipment with provider prior to rough-in.Provide line voltage controls and wiring as required. Field verify control requirements with provider.Provide HACR breakers for all circuits serving equipment.

LOADHP,KW,FLA

32 MCA50 MOCP14 MCA

25 MOCP1 MCA

15 MOCP4500W

VOLTS

208

208

120

208

Ø

3

1

1

1

BRANCH CKT.CONDUCTORS

4#6,#10G

3#10,#10G

2#12,#12G

3#10,#10G

CONDUIT

1"

3/4"

3/4"

3/4"

DISCONNECTSWITCH60A/3P

WP30A/2P

WPVERIFY

Sto

FUSE--

--

VERIFY

NA

October 7, 2021CIRCUIT

E-37,39,41

E-38,40

POWER BYCU-1

E-34,36

NOTES

1

1

1

1

9 9

26

CS

1

CU

1

RTU

1

4

4

4

4

4

4

4

8

PANEL E

24

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014FX: 303.362.7361

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

JPT

SCF

09.30.2021

KVA21-145/ETM2016

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

PROFESS I ONA L ENGI N EER

87066L I C E N S E D

JOHN TINSLEY

S T A T E O F T E X A S

FIRM NUMBER: 7684kVA Consulting

19600 E Parker Square Dr., B100, Parker, CO 80134(303) 646-4770 Direct | [email protected]

TEN

AN

T FI

NIS

H F

OR

ELE

ME

NTS

MA

SS

AG

ES

AN

AN

TON

IO17

038

FIE

STA

TE

XA

S D

RIV

ES

UIT

E 1

08S

AN

AN

TON

IO, T

X 7

8256

E1.0POWER PLAN

F9

F9

F9F9

F9 F1

F6

F6

F1

F1

F1

F1

F7

F7

F7

F1

F1

F7

F1

F1

F6

F6

F6

F6

F1

F1

F7

F1

F1

F7

F7

F1

F1

F1

F1 F1

F1

F1

F1

F1F1F1

E1/E2

E1/E2

F10

F1

F1F1

F6

F6

E2

F4A

F4A

F4B

F1

F1

VV

V

VV

VV

SCALE:

1E2.0

LIGHTING PLAN1/4"=1'-0"

LIGHTING PLAN GENERAL NOTES:

1. CONNECT EGRESS LIGHTING FIXTURES AND EXIT SIGNS TO AREA LIGHTINGCIRCUIT AHEAD OF ANY SWITCH PER NEC 700-12(F) INCLUDING ANY NIGHTLIGHTS. FIXTURES SHOWN SHADED OR LABELED ARE EMERGENCY EGRESS (EM)WITH BATTERY PACK, NIGHT LIGHT (NL) OR BOTH (EM/NL). REMOVE ANY HOUSEPANEL CIRCUITS SERVING EXISTING EMERGENCY AND EXIT LIGHTS ANDRECONNECT TO THE TENANT PANEL.

2. PROVIDE OUTLET IN ACCESSIBLE LOCATION AT TENANT ENTRANCE FOR SIGN PERNEC 600-5.

3. NUMBERS NEXT TO DEVICES REFER TO CIRCUIT DESIGNATION IN PANEL 'E' UNLESSNOTED. PROVIDE WITH COMPATIBLE DIMMERS - TYPICAL ALL SWITCHES.

4. PER IECC 405.2, OCCUPANCY SENSOR CONTROLS SHALL BE CAPABLE OFMONITORING OCCUPANT ACTIVITY TO CONTROL LIGHT LEVELS BOTH WHENOCCUPIED OR UNOCCUPIED, AND MONITORING AMBIENT LIGHT BOTHELECTRIC AND DAYLIGHT TO CONTROL DESIRED LIGHT LEVEL. FOR EACHCONTROL STRATEGY, CONFIGURATION AND RECONFIGURATION OFPERFORMANCE PARAMETERS SHALL INCLUDE: BRIGHT AND DIM SETPOINTS,TIMEOUTS, DIMMING FADE RATES, SENSOR SENSITIVITY ADJUSTMENTS, ANDWIRELESS ZONING CONFIGURATIONS. EXEMPT AREAS ARE SECURITY OREMERGENCY AREAS; INTERIOR EXIT STAIRWAYS, RAMPS AND PASSAGEWAYS;EMERGENCY EGRESS LIGHTING THAT IS NORMALLY OFF.

5. PER IECC 405.2.1, OCCUPANCY SENSOR CONTROLS SHALL BE INSTALLED IN THEFOLLOWING SPACES: CLASSROOMS/LECTURE/TRAINING ROOMS,CONFERENCE/MEETING/MULTIPURPOSE ROOMS, COPY/PRINT ROOMS,LOUNGES/BREAKROOMS, ENCLOSED OFFICES, OPEN OFFICES, RESTROOMS,STORAGE ROOMS, LOCKER ROOMS, WAREHOUSE STORAGE AREAS, AND OTHERSPACES 300 SQUARE FEET OR LESS ENCLOSED BY FLOOR-TO-CEILING HEIGHTPARTITIONS.

6. PER IECC 405.2.1.1, OCCUPANT SENSOR CONTROL FUNCTION, EXCLUDINGWAREHOUSES AND OPEN OFFICE SPACES, SHALL AUTOMATICALLY TURN OFFLIGHTS WITHIN 20 MINUTES AFTER ALL OCCUPANTS HAVE LEFT THE SPACE. THEYSHALL BE MANUAL ON OR CONTROLLED TO AUTOMATICALLY TURN ON THELIGHTING TO NOT MORE THAN 50% POWER (CORRIDORS, STAIRWAYS,RESTROOMS, PRIMARY ENTRANCES AND LOBBIES, AND AREAS WHERE MANUALOPERATION WOULD ENDANGER THE OCCUPANTS OR SECURITY OF THE ROOMOR OCCUPANTS ARE EXEMPT). THEY SHALL ALSO INCORPORATE MANUALCONTROLS TO ALLOW OCCUPANTS TO TURN OFF THE LIGHTING.

7. PER IECC 405.2.2, ANY AREA OF THE BUILDING NOT PROVIDED WITH ANOCCUPANT SENSOR CONTROL COMPLYING WITH SECTION 405.2.1.1 SHALL BEPROVIDED WITH TIMECLOCK CONTROLS COMPLYING WITH SECTION 405.2.2.1.EXCEPTION: WHERE MANUAL CONTROL PROVIDES LIGHT REDUCTION INACCORDANCE WITH SECTION 405.2.2.2, TIMECLOCK CONTROLS SHALL NOT BEREQUIRED IN THE FOLLOWING: SPACES WHERE PATIENT CARE IS DIRECTLYPROVIDED; SPACES WHERE AN AUTOMATIC SHUT-OFF WOULD ENDANGEROCCUPANT SAFETY OR SECURITY; LIGHTING INTENDED FOR CONTINOUSOPERATION; SHOP AND LABORATORY CLASSROOMS.

8. DAYLIGHT RESPONSIVE CONTROLS COMPLYING WITH IECC 405.2.3.1 SHALL BEPROVIDED WITHIN DAYLIGHT ZONES IN SPACES TOTALING MORE THAN 150W OFGENERAL LIGHTING WITHIN SIDELIT AND TOPLIT ZONES. PATIENT CAREFACILITIES, APPLICATION LIGHTING, AND SIDELIT ZONES IN FIRST FLOORS ABOVEGRADE IN GROUP A-2 AND GROUP M OCCUPANCIES ARE EXEMPT. TOPLITZONES AND SIDELIT ZONES MUST BE CONTROLLED INDEPENDENTLY FROM EACHOTHER. DAYLIGHT RESPONSIVE CONTROLS MUST BE CONFIGURED SUCH THATTHEY MAY BE CALIBRATED FROM WITHIN THE SPACE, AND CALIBRATIONMECHANISMS MUST BE IN A LOCATION WITH EASY ACCESS. WHERE LOCATED INOFFICES, CLASSROOMS, LABORATORIES AND LIBRARY READING ROOMS,CONTROLS SHALL DIM LIGHTS CONTINUOUSLY FROM FULL LIGHT TO 15% OFFULL OUTPUT OR LOWER. DAYLIGHT RESPONSIVE CONTROLS MUST BECONFIGURED TO BE ABLE TO SHUT OFF ALL CONTROLLED LIGHTS. LIGHTS INSIDELIT ZONES FACING DIFFERENT CARDINAL DIRECTIONS (NORTH, SOUTH,EAST, WEST) MUST BE CONTROLLED INDEPENDENTLY FROM EACH OTHER.

8.1. SIDELIT DAYLIGHT ZONES EXTEND INTO THE SPACE 1 TIMES THE HEIGHT OFTHE FENESTRATION TO THE NEAREST WALL, WHICHEVER IS SHORTER, ANDARE AS WIDE AS THE FENESTRATION PLUS 2'-0" ON THE END OR TO THENEAREST WALL PER IECC 405.2.3.2.

8.2. TOPLIT DAYLIGHT ZONES EXTEND IN ALL DIRECTIONS FROM THE EDGE OFTHE ROOF FENESTRATION UP TO 0.7 TIMES THE CEILING HEIGHT, OR TOTHE NEAREST OBSTRUCTION 0.7 TIMES THE CEILING HEIGHT PER IECC405.2.3.3.

9. ALL RECEPTACLE AND SWITCH FACEPLATES TO BE COLORED WHITE PER ELEMENTSMASSAGE STANDARD.

LIGHTING PLAN KEYED NOTES:

1. WALLBOX DIMMER/OCCUPANCY SENSOR SWITCH - PROVIDE COOPER - EATONOSW-D-010-* OR EQUAL RATED FOR CONNECTED LOAD TYPE AND WATTAGE.OCCUPANCY SENSOR SHALL EITHER BE MANUAL ON, OR AUTO ON TO 50%POWER, EXCEPT WHERE EXEMPTED PER IECC C405.2.1.1. SENSORS MUST BE SETTO TURN OFF WITHIN 20 MINUTES OF LEAVING SPACE PER C405.2.1.1(1).

2. WALLBOX DIMMER SWITCH - PROVIDE COOPER - EATON SF10P-* OR EQUAL BYCOOPER RATED FOR CONNECTED LOAD TYPE AND WATTAGE.

3. TENANT SIGN - PROVIDE DEDICATED CIRCUIT AND FINAL CONNECTIONS ASREQUIRED. FIELD VERIFY ELECTRICAL REQUIREMENTS AND FINAL LOCATION WITHPROVIDER, TENANT AND LANDLORD. PROVIDE PHOTOCELL ON/TIMECLOCK OFFCONTROLS.

4. PROVIDE J-BOX FOR CONNECTION OF SPEAKER VOLUME CONTROL DEVICE ONWALL WITH JUNCTION BOX AND 1/2" CONDUIT WITH PULLSTRING SECUREDABOVE CEILING. VERIFY FINAL LOCATIONS WITH TENANT PRIOR TO ANY WORK.

5. FIXTURE TYPE F7 IN MASSAGE ROOMS TO BE CONTROLLED BY SPECIAL KEYPADDEVICE SPECIFIED BY OWNER.

6. FIELD VERIFY EXISTING CONDITIONS PRIOR TO ANY WORK AND PROVIDE NEWEXTERIOR EMERGENCY EGRESS LIGHT TO MATCH BUILDING STANDARD IF NONEARE EXISTING AT LOCATION.

7. FIXTURE TO BE CIRCUITED AS A NIGHT LIGHT.8. LOCATION OF TIMECLOCK CONTROLS FOR ANY REQUIRED LIGHTING AND

SIGNAGE.9. PROVIDE DAYLIGHTING CONTROLS FOR FIXTURES IN AREAS INDICATED.

DAYLIGHTING CONTROLS TO USE LEVITON ODC0P-D0W OR SIMILAR DIMMINGPHOTOCELL. PHOTOCELL CONTROLS MUST REDUCE LIGHT LEVELS PER IECCC405.2.3, C405.2.3.1, C405.2.3.2, AND ANY AHJ SPECIFIC REQUIREMENTS.

#

SWITCH LEGS

C ELECTRONIC WALL SWITCH TIME-CLOCK.PROVIDE WITH OVERRIDE SWITCH;

OVERRIDE NOT TO EXCEED 2 HOURS

CONTROLCIRCUIT

E-23

SPARE

LIGHTING CONTACTOR WITH ROOM FORALL INTERIOR LIGHTING CIRCUITS -PROVIDE AS REQUIRED WITH MINIMUM 2SPARES

SCALE:

2E2.0

LIGHTING CONTROL DIAGRAMNTS

E-31

14

5

23

14

5

23

14

5

23

14

5

23

14

5

23

14

5

23

14

5

23

223

1

1

x

x

x

x

x

x

x

x

y

a

a1

a1

a1a1

a1 a1

a1a1

a a

b

b

b

96

J3

abcd

a1

c

LUMINAIRE SCHEDULEKEY

INTERIOR FIXTURES

F1

F4A

F4B

F5

F6

F7

F9

F10

E1

E2

NOTES: (Notes apply to all fixtures where applicable)

1.

2.

3.

4.

5.

6.

7.

DESCRIPTION

RECESSED DOWNLIGHT

DECORATIVE PENDANT

DECORATIVE PENDANT

LED TAPE

PINHOLE LIGHT

LINEAR RECESSED LIGHT

WITH OCCUPANCY SENSOR

2X2 RECESSED LED LIGHT

ROUND LINEAR LED

EXIT SIGNAGE

EMERGENCY LIGHT

EMERGENCY FIXTURES - All Fixtures Indicated as Emergency shall be provided with a 90-Minute Battery Pack and all Fluorescent Fixtures

indicated as Emergency shall be provided with a 1300 Lumen, 90-Minute Battery Pack.

VERIFY VOLTAGES - The E.C. shall verify voltages on drawings prior to ordering or any work, the engineer shall be notified of any descrepancies

in the voltage of the circuiting on the drawings and the luminiare schedule prior to any purchase or work.

VERIFY LAMPING - The E.C. shall verify lamping with the manufacturer prior to ordering and notify the engineer of any lamping descrepancies.

PROVIDE A COMPLETE INSTALLATION - The E.C. shall provide all labor and material to provide a complete and functional system per the design intent as dictated by the

switching type and location (including dimmer switches and compatible ballasts or transformers), ceiling type and location, circuiting, voltages, and lamping types.

BALLAST DISCONNECT - All electric discharge luminaires shall comply with 2008 nec 410.130 and shall have a means of disconnect for the ballast.

DUAL LEVEL SWITCHING - For fixtures with more than one switch designation shown on plans provide fixtures with additional ballasts for dual level light

control by separate switching of inboard and outboard lamps as required to conform to IECC Requirements.

CONTACT JOSH HUISKEN AT WEDENBAUGH BROWN, 714.553.5993 [email protected], FOR COMPLETE LIGHTING PACKAGE

MFR. & CAT.NO.

AMERLUX

HDL-HP-R-NC-A17-T-13-120-0-10V/RD-A17-T-MWW-SP-30

TECH LIGHTING

700TDCLOPMWYS-LED830

TECH LIGHTING

700TDCLOPGWYS-LED-830

OPTIC ARTS

FLEXDC-40-30K-24-30

AMERLUX

HDL-HP-R-NC-A17-T-13-120-0-10V/HP-RPA-A17-T-MW-SP-30

ALW

LP2RT-TGRID-S8-RGBW-DMX-EXT/F-AL-UNV-OS

LITHONIA

EPANL-2X2-400LM-80CRI-35K-MIN10-ZT-MVOLT

PINNACLE

M-A-830-LO-4-WH06-U-OL1-1-O-W

EXITRONIX

S900-WB-SR-G-WH

EXITRONIX

LED-51-WH-G2

LAMP

13W LED

50W MAX

50W MAX

1W/FT

13W LED

5W/FT

32.2W LED

14W LED

INCL

INCL

VOLTS

120

120

120

120

120

120/277

120

120

120

120

October 7, 2021

MOUNTING

INFORMATION

VERIFY W/ARCH

VERIFY W/ARCH

VERIFY W/ARCH

VERIFY W/ARCH

VERIFY W/ARCH

VERIFY W/ARCH

VERIFY W/ARCH

VERIFY W/ARCH

VERIFY W/ARCH

VERIFY W/ARCH

NOTE

xy

dd

F5 F5

18

EF

1

EF

2

31

317

8

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014FX: 303.362.7361

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

JPT

SCF

09.30.2021

KVA21-145/ETM2016

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

PROFESS I ONA L ENGI N EER

87066L I C E N S E D

JOHN TINSLEY

S T A T E O F T E X A S

FIRM NUMBER: 7684kVA Consulting

19600 E Parker Square Dr., B100, Parker, CO 80134(303) 646-4770 Direct | [email protected]

TEN

AN

T FI

NIS

H F

OR

ELE

ME

NTS

MA

SS

AG

ES

AN

AN

TON

IO17

038

FIE

STA

TE

XA

S D

RIV

ES

UIT

E 1

08S

AN

AN

TON

IO, T

X 7

8256

E2.0LIGHTING PLAN

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014FX: 303.362.7361

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

JPT

SCF

09.30.2021

KVA21-145/ETM2016

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

PROFESS I ONAL ENG I N EER

87066L I C E N S E D

JOHN TINSLEY

S T A T E O F T E X A S

FIRM NUMBER: 7684kVA Consulting

19600 E Parker Square Dr., B100, Parker, CO 80134(303) 646-4770 Direct | [email protected]

TEN

ANT

FIN

ISH

FO

R

ELEM

ENTS

MAS

SAG

ESA

N A

NTO

NIO

1703

8 FI

ESTA

TEX

AS D

RIV

ESU

ITE

108

SAN

AN

TON

IO, T

X 78

256

EN1.0ENERGY COMPLIANCE FORMS

DESIGN PARAMETERS, LLC6373 SILVER STREAM LN

FRISCO, TX 75036PH: 214.784.5014FX: 303.362.7361

WWW.DESIGNPARAMETERS.COM

START DATE

DRAWN BY

CHECKED BY

PROJECT NO

copyright 2021

JPT

SCF

09.30.2021KVA21-145/ETM2016

NO. DESCRIPTION DATE1 PERMIT 10.07.2021

PROFESS I ONA L ENGI N EER

87066L I C E N S E D

JOHN TINSLEY

S T A T E O F T E X A S

FIRM NUMBER: 7684kVA Consulting

19600 E Parker Square Dr., B100, Parker, CO 80134(303) 646-4770 Direct | [email protected]

TEN

ANT

FIN

ISH

FO

R

ELEM

ENTS

MAS

SAG

ESA

N A

NTO

NIO

1703

8 FI

ESTA

TEX

AS D

RIV

ESU

ITE

108

SAN

AN

TON

IO, T

X 78

256

EN2.0ENERGY COMPLIANCE FORMS