GB GE/FO230408 This starts and monitors the generating set, and stops it in the event of an anomaly through solenoid valve or electromagnet. It shows the main parameters of the generating set on the display. This has provision for automatic operation. Possibility of combination with ATS - 100 or ATS - 200 control unit to obtain power switching control. Texts in: Italian English German French Spanish Portuguese ® Manual start/stop buttons Remotestartinput Possibility of starting the generator when the chargeofthebatteryislow Available fully program- mable input for anomaly (times, polarities, stop- ping possibility and mes- sageabouttheanomaly) Glow plugs preheating management Clock for programming the starting or the stop- pingoftheengine Weeklyselftest Complete with 13 in- struments (synchronous readingof6) Anomaly historical record (Including data from the last 100 anoma- lies) Indication of preventi- ve maintenance SELF-CONTAINED GENERATING SET CONTROL UNIT TYPE CAM-110 SELF-CONTAINED GENERATING SET CONTROL UNIT TYPE CAM-110

Upload: others

Post on 04-Jan-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: GB GE/FO230408 SELF-CONTAINED GENERATING SET CONTROL … · GB GE/FO230408 This starts and monitors the generating set, and stops it in the event of an anomaly through solenoid valve

GB GE/FO230408

This starts and monitors the generating set,and stops it in the event of an anomalythrough solenoid valve or electromagnet.

It shows the main parameters ofthe generating set on the display.

This has provision for automatic operation.Possibility of combination with ATS - 100or ATS - 200 control unit to obtain powerswitching control.

Texts in:

Italian

English

German

French

Spanish

Portuguese®

M a n u a l s t a r t / s t o pbuttons

Remotestartinput

Possibility of startingthe generator when thechargeofthebatteryislow

Availablefullyprogram-mable input for anomaly(times, polarities, stop-ping possibility and mes-sageabouttheanomaly)

Glow plugs preheatingmanagement

Clock for programmingthe starting or the stop-pingoftheengine

Weeklyselftest

Complete with 13 in-struments (synchronousreadingof6)

Anomaly h is tor ica lrecord (Including datafrom the last 100 anoma-lies)

Indication of preventi-ve maintenance

SELF-CONTAINED GENERATING SETCONTROL UNIT

TYPE CAM-110

SELF-CONTAINED GENERATING SETCONTROL UNIT

TYPE CAM-110

Page 2: GB GE/FO230408 SELF-CONTAINED GENERATING SET CONTROL … · GB GE/FO230408 This starts and monitors the generating set, and stops it in the event of an anomaly through solenoid valve

BRIEF INSTRUCTIONSBRIEF INSTRUCTIONS

Via Naviglio Alto,24/A 43100 PARMA (ITALY) - Tel. 0521.772021 / Fax 0521.270218 e-mail: [email protected]

- BATTERY POWER

SUPPLY

- DEGREE OF PROTECTION

• FRONT IP64

• REAR IP00

- DIMENSIONS (LxHxP)mm 157 x 109 x 52

9 ÷ 32 VDC

GENERATOR VOLTMETER

GENERATOR AMMETER

FREQUENCY METER

WATTMETER

VARMETER

COSPHIMETER

KILOWATT-HOUR

PARTIAL HOUR METER

TOTAL HOUR METER

STARTING COUNTER

TACHOMETER

FUEL LEVEL

INDICATOR

CAN Bus

Possibility of connection with engine equippedwith control unit for electronic control ofthe injection system

CAN Bus ENGINE

TECHNICAL DATADISPLAYED INSTRUMENTSDISPLAYED INSTRUMENTS

CAM-110

®

OFF

AUT

MAN

PROG

G

RESET

MAN AUT OFF PROG

V A

STOP START

HZ

RPM%%

PRESS TO STOP THEENGINE WHEN THECONTROL UNIT IS INMANUAL OPERATION

DISPLAY

CUMULATIVEALARM WITHENGINE STOP

THE CALLIS CLOSED

PRESS TORESET THECONTROL UNIT

PRESS TO STARTTHE ENGINEWHEN THECONTROL UNITIS IN MANUALOPERATION

ENGINE ISRUNNING

THE OPERATIONMODE OF THECONTROL UNIT IS:• MANUAL• AUTOMATIC• OFF• USERPROGRAMMING

GENERATORVOLTAGEIS PRESENT

PREVENTIVEMAINTENANCE.CUMULATIVE ALARMWITHOUT STOP

PRESS TOSELECT THEOPERATION MODE:• MANUAL• AUTOMATIC• OFFAND USERPROGRAMMING

PRESS BRIEFLYTO SHOW THEINSTRUMENTS,HOLD DOWNTO VERIFYTHE LED TEST.GENERAL ALARMSILENCING

MAN