p22-6(4pp)gb(0212) - coromatic ab · 2018-02-01 · dealer contact details: documentation...
TRANSCRIPT
Output Ratings Ratings and Performance Data
Leroy Somer
Prime Standby Engine Make & Model:
Alternator manufactured for FG Wilson by:
Alternator Model:
Control Panel:
Circuit Breaker Type:
Engine Speed: RPM
Base Frame:
zH 06zH 05:ycneuqerF
Fuel Tank Capacity:
Dimensions and Weights
Length (L)mm (in)
Width (W)mm (in)
Height (H)mm (in)
Drykg (lb)
Wetkg (lb)
Dry = With Lube Oil Wet = With Lube Oil and Coolant
Ratings in accordance with ISO 8528, ISO 3046, IEC 60034, BS5000 and NEMA MG-1/22. Generating set pictured may include optional accessories.
www.FGWilson.com
//
//
Fuel Consumption:
(100% Load) - Prime
Ratings at power factor.
Image for illustration purposes only.
- Standby
Available Options
FG Wilson offer a range of optional features to tailor our generating sets to meet your power needs. Options include:
A wide range of Sound Attenuated Enclosures
A variety of generating set control panels
Additional alarms and shutdowns
For further information on all of the standard and optional features accompanying this product please contact your local Dealer or visit: www.FGWilson.com
LL1114M
20.0 kVA 16.0 kW 22.0 kVA 17.6 kW
22.5 kVA 18.0 kW 25.0 kVA 20.0 kW
P22-6
Heavy Duty Fabricated Steel
3 Pole MCB
18001500
66 (17.4)
5.8 (1.5)5.3 (1.4)
6.5 (1.7)5.9 (1.6)
1500 (59.1) 620 (24.4) 1115 (43.9) 447 (985) 454 (1001)
0.8 DCP-10
Perkin® 404D-22G
400V, 50 Hz
480V, 60 Hz
Prime Rating These ratings are applicable for supplying continuous electrical power(at variable load) in lieu of commercially purchased power. There is nolimitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.
Standby Rating These ratings are applicable for supplying continuous electrical power (atvariable load) in the event of a utility power failure. No overload ispermitted on these ratings. The alternator on this model is peakcontinuous rated (as defined in ISO 8528-3).
Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m(328 ft) A.S.L. 30% relative humidity.Fuel consumption data at full load with diesel fuel with specific gravity of0.85 and conforming to BS2869: 1998, Class A2.
Please refer to the output ratings technical data section forspecific generator set outputs per voltage.
Voltage, Frequency
Exhaust System
Silencer Type:
Silencer Model & Quantity:
Pressure Drop Across Silencer System: kPa (in Hg)
Silencer Noise Reduction Level: dB
Maximum Allowable Back Pressure: kPa (in Hg)
Exhaust Gas Flow: m³/min (cfm)
Exhaust Gas Temperature: °C (°F)
60 Hz50 Hz
- Prime
- Standby
- Prime
- Standby
Lubrication System
Oil Filter Type:
Total Oil Capacity: l (US gal)
Oil Pan: l (US gal)
Oil Type:
Oil Cooling Method:
Cooling System
Cooling System Capacity: l (US gal)
Water Pump Type:
Heat Rejected to Water & Lube Oil:
kW (Btu/min)
Heat Radiation to Room: Heat radiated from engine and alternator
kW (Btu/min)
Radiator Fan Load: kW (hp)
Radiator Cooling Airflow: m³/min (cfm)
External Restriction to Cooling Airflow: Pa (in H2O)
Designed to operate in ambient conditions up to 50°C (122°F).Contact your local FG Wilson Dealer for power ratings at specific site conditions.
60 Hz50 Hz
- Prime
- Standby
- Prime
- Standby
Engine Technical Data Air Systems
No. of Cylinders / Alignment:
Cycle:
Bore / Stroke: mm (in)
Induction:
Engine Speed: rpm
Performance
Gross Engine Power: kW (hp)
BMEP: kPa (psi)
Fuel System
Fuel Filter Type:
Recommended Fuel:
Fuel Consumption: l/hr (US gal/hr)
Prime
50 Hz
60 Hz
110% 100% 75% 50%
Load Load Load Load
60 Hz
50 Hz
Standby Load Load Load Load
50%75%100%110%
(Based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)
Air Filter Type:
Combustion Air Flow: m³/min (cfm)
Max. Combustion Air Intate Restriction: kPa (in H2O)
60 Hz50 Hz
Cooling Method:
Governing Type:
Governing Class:
Compression Ratio:
Displacement: l (cu. in)
Moment of Inertia: kg m² (lb/in²)
Engine Electrical System:
Weight: kg (lb)
60 Hz50 Hz
- Standby
- Prime
- Standby
- Prime
- Standby
- Prime
- Dry
- Wet
- Voltage / Ground
- Battery Charger Amps
440 (824)445 (833)
510 (950)505 (941)
4.3 (153)3.6 (129)
4.8 (168)3.9 (139)
10.2 (3.0)10.2 (3.0)
21.529
1.60 (0.472)0.70 (0.207)
263-0765 (1)
Industrial
N/A
8.9 (2.4)
10.6 (2.8)
Spin-On, Full Flow
API CH4 15W-40
6.5 (1.7)6.5 (1.7)
Centrifugal
19.9 (1132)
22.2 (1262)
17.0 (967)
19.6 (1115)
6.3 (358)5.7 (324)
7.4 (421)7.1 (404)
0.4 (0.5)0.2 (0.3)
41.4 (1462)33.0 (1165)
125 (0.5)125 (0.5)1500 1800
Class A2 Diesel
Replaceable Element
4 / In Line
4 Stroke
84.0 (3.3)/100.0 (3.9)
Naturally Aspirated
Water
ISO 8528
Mechanical
23.3:1
2.2 (135.2)
2.72 (9308)
12/Negative
65
242 (534)
251 (554)
675.0 (97.9) 662.0 (96.0)
731.0 (106.0)743.0 (107.8)
22.0 (30.0)
24.3 (33.0)
18.7 (25.0)
20.6 (28.0)
3.3 (0.9)4.5 (1.2)5.8 (1.5)6.5 (1.7)
2.9 (0.8)3.9 (1.0)5.3 (1.4)5.9 (1.6)
3.6 (1.0)
3.1 (0.8)
4.9 (1.3)
4.3 (1.1)
6.5 (1.7)
5.9 (1.6)
Replaceable Element
1.7 (61)1.5 (51)
1.7 (61)1.5 (51)
3.0 (12.0)3.0 (12.0)
Alternator Physical Data
Manufactured for FG Wilson by:
Model:
No. of Bearings:
Insulation Class:
Winding Pitch Code:
Wires:
Ingress Protection Rating:
Excitation System:
AVR Model:
Overspeed: rpm
Voltage Reguation: (Steady state)
Wave Form NEMA = TIF:
Wave Form IEC = THF:
Total Harmonic content LL/LN:
Radio Interference:
Radiant Heat: kW (Btu/min)
- 50 Hz
- 60 Hz
Voltage Technical Data 50 Hz
Voltage Prime: Standby:
kVA kW kVA kW
AlternatorPerformance Data:
Data Item
Motor Starting
Capability* kVA
Short Circuit
Capacity %
Reactances: Per Unit
Xd
X'd
X"d
Reactances shown are applicable to prime ratings. *Based on 30% voltage dip at 0.6 power factor.
Leroy Somer
Suppression is in line with European Standard EN61000-6
Voltage Technical Data 60 Hz
Voltage Prime: Standby:
kVA kW kVA kW
Output Ratings Technical Data 50 Hz
Voltage Prime: Standby:
Output Ratings Technical Data 60 Hz
Voltage Prime: Standby:
60 Hz50 Hz
Alternator Operating Data
6.71V042/51 0.224 16.020.0
6.71V032/00 0.224 16.020.0
60.61 .710.0 0.222380/220V
- ---
3.4403.4203.0902.870
0.2700.2700.2500.230
0.1370.1360.1230.114
52485255
R220
SHUNT
IP23
12
2/3 - 6
H
1
LL1114M
0.02V721/02 0.522 18.022.5
2.8 (159)
2.7 (154)
4.0%
2.0%
50
+/- 1.0%
2250
415/240V 400/230V 380/220V
220/127V
Dealer contact details:
Documentation
Generating Set Standards
Warranty
General Information
P22-6/4PP/0414/GB
FG Wilson manufactures product in the following locations:Northern Ireland • Brazil • China • India • USAWith headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.
FG Wilson is a trading name of Caterpillar (NI) Limited.
In line with our policy of continuous product development, we reserve the right to change specification without notice.