gas turbine sgt-600 - siemens484a8f1a1… · combined cycle power generation siemens combined cycle...

2
Easy to maintain, reliable, and robust twin-shaft designed core engine, consisting of gas generator plus a free spinning power turbine 1 DLE combustion system Well-proven and reliable dry low emissions (DLE) combustor with low emissions. 2 Power turbine Two-stage uncooled free power turbine offers nominal shaft speed up to 7,700 rpm. For mechanical drive, it may operate at 50 to 105 percent of the nominal speed. The blades use inter- locking shrouds for extra robustness. 3 Compressor 10-stage axial flow transonic compressor with three balancing planes accessible from the outside. 1 2 3 Key benefits 25-MW gas turbine 34.6% simple cycle efficiency More than 330 units sold (> 9 million equivalent operating hours) Robust, reliable design High fuel flexibility – High exhaust energy Well-proven dry low emissions (DLE) combustion system < 15 Ppmvd On-load fuel changeover (gas to liquid fuel and liquid fuel to gas) Low lifecycle costs Gas turbine SGT-600 For power generation and mechanical drive applications A small footprint, high fuel flexibility, and third-generation DLE make the SGT-600 the perfect choice. Typical applications include industrial power generation in combined heat and power (CHP), and combined cycle power plants (CCPP), onshore oil and gas power generation, and mechanical drives. High fuel flexibility Available with both conventional and DLE combustion systems Gaseous and liquid fuels on-load changeover Third-generation DLE system Best-in-class NO x emission levels Important features Low emissions maintained on different fuels Maximized uptime Robust industrial design Small environmental footprint High lifetime profitability Customer service and maintenance 24-hour gas generator swap Maximized serviceability – on-site maintenance or gas generator removal for off-site maintenance Service plan with just 17 scheduled maintenance days over a 17-year service cycle Minimized load-to-load downtime Remote diagnostic service with online monitoring, expert perfor- mance data analysis, and fleet data comparisons 24-hour global help desk siemens.com/gasturbines PGDG-T10012-00-7600-Factsheet-SGT-600.indd 1 04.05.18 12:35

Upload: others

Post on 18-Oct-2020

14 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Gas turbine SGT-600 - Siemens484a8f1a1… · Combined cycle power generation Siemens combined cycle power plant SCC-600 1 x 1 SCC-600 2 x 1 Net power output 35.9 MW(e) 73.3 MW(e)

Easy to maintain, reliable, and robust twin-shaft designed core engine, consisting of gas generator plus a free spinning power turbine

1 DLE combustion system Well-proven and reliable dry low emissions (DLE) combustor with low emissions.

2 Power turbine Two-stage uncooled free power turbine offers nominal shaft speed up to 7,700 rpm. For mechanical drive, it may operate at 50 to 105 percent of the nominal speed. The blades use inter-locking shrouds for extra robustness.

3 Compressor 10-stage axial flow transonic compressor with three balancing planes accessible from the outside.

123

Key benefits

• 25-MW gas turbine• 34.6% simple cycle efficiency• More than 330 units sold

(> 9 million equivalent operating hours)

• Robust, reliable design• High fuel flexibility –

High exhaust energy• Well-proven dry low emissions (DLE)

combustion system < 15 Ppmvd• On-load fuel changeover

(gas to liquid fuel and liquid fuel to gas)

• Low lifecycle costs

Gas turbine SGT-600For power generation and mechanical drive applications

A small footprint, high fuel flexibility, and third-generation DLE make the SGT-600 the perfect choice. Typical applications include industrial power generation in combined heat and power (CHP), and combined cycle power plants (CCPP), onshore oil and gas power generation, and mechanical drives.

High fuel flexibility• Available with both conventional

and DLE combustion systems• Gaseous and liquid fuels on-load

changeover• Third-generation DLE system• Best-in-class NOx emission levels

Important features• Low emissions maintained

on different fuels• Maximized uptime• Robust industrial design• Small environmental footprint• High lifetime profitability

Customer service and maintenance• 24-hour gas generator swap• Maximized serviceability – on-site

maintenance or gas generator removal for off-site maintenance

• Service plan with just 17 scheduled maintenance days over a 17-year service cycle

• Minimized load-to-load downtime• Remote diagnostic service with

online monitoring, expert perfor-mance data analysis, and fleet data comparisons

• 24-hour global help desk

siemens.com/gasturbines

PGDG-T10012-00-7600-Factsheet-SGT-600.indd 1 04.05.18 12:35

Page 2: Gas turbine SGT-600 - Siemens484a8f1a1… · Combined cycle power generation Siemens combined cycle power plant SCC-600 1 x 1 SCC-600 2 x 1 Net power output 35.9 MW(e) 73.3 MW(e)

–30 –20 –10 0 10 20 30 40 50 60

Published by Siemens AG 2016

Power and Gas Division Distributed Generation Freyeslebenstrasse 1 91058 Erlangen, Germany

Article No. PGDG-T10012-00-7600 Printed in Germany Dispo 34806 TH 566-160138 FS 0816Subject to changes and errors. The information given in this document only contains general descriptions and/or perfor-mance features which may not always specifi-cally reflect those described, or which may undergo modification in the course of further devel opment of the products. The requested performance features are binding only when they are expressly agreed upon in the con-cluded contract.

Note: At ISO conditions. All combined cycle per-formance is based on dual pressure, no reheat. Above dimensions exclude inlet filter housing and exhaust stack. For power generation, AC generator is included. For mechanical drive, driven equipment is excluded.

Simple cycle power generation Mechanical drive applicationsPower output 24.5 MW(e) 25.3 MWFuel Natural gas, liquid fuel, dual fuelFrequency 50/60 HzGross efficiency 33.6% 34.6%Heat rate 10,720 kJ/kWh 10,390 kJ/kWhTurbine speed 7,700 rpm 3,850 – 8,085 rpmPressure ratio 14.0 : 1Exhaust gas flow 81.3 kg/sExhaust temperature 543° C (1,009° F)NOx emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensionsPower generation package Mechanical drive package

Approx. weight 150,000 kg (330,693 lb) 59,000 kg (130,072 lb)Length 18.8 m (61.7 ft) 11.7 m (38.4 ft)Width 4.6 m (15.0 ft) 4.0 m (13.1 ft)Height 4.0 m (13.1 ft) 4.0 m (13.1 ft)

Combined cycle power generationSiemens combined cycle power plant

SCC-600 1 x 1 SCC-600 2 x 1

Net power output 35.9 MW(e) 73.3 MW(e)Net plant efficiency 49.9% 50.9%Net heat rate 7,220 kJ/kWh 7,071 kJ/kWhNumber of gas turbines 1 2

Gas turbines from 4 to 400 MW

Above performances at ISO conditions, gaseous fuel

SGT-600 performance

Power generation packageThe SGT-600’s ability to handle sudden load changes and its high exhaust temperature makes it ideal for simple cycle, combined cycle, cogeneration, and other heating applications.• Small footprint for easy fitting• Modular and flexible package design• Single-lift capability

Mechanical drive packageSGT-600 mechanical drive packages offer long lifecycles and can withstand extreme climates ranging from hot deserts to arctic cold, oil platforms, and harsh industrial environments:• Variable power turbine speed: 50 to 105%• High load on low-power turbine speed• Maintains efficiency at partial load• Low emissions at partial load

Nominal performance

Shaf

t pow

er o

utpu

t [M

W]

Power turbine speed [rpm]

Power MD Power PG Heat rate MD Heat rate PGNominal performance mechanical drive at 15° C

50 o

r 60

Hz

60 H

z50

Hz 400 MW

53 to 66/54 to 62 MW

19/19 MW

48 to 54 MW

13 to 14 MW/13 to 15 MW

38/39 MW

8/8 to 9 MW

33/34 MW

7/8 MW

27 to 32/28 to 34 MW

5/6 MW

24/25 MW

4 to 6 MW

117 MW

307 MW187 MW

296 MW242 MW

SGT5-8000H

Industrial Trent 60

SGT-500

SGT-800

SGT-400

SGT-750

SGT-300

SGT-700

SGT-200

Industrial RB211

SGT-100

SGT-600

Industrial 501-K

SGT6-2000E

SGT5-4000FSGT5-2000E

SGT6-8000HSGT6-5000F

Base load Reserve peak load [MJ/kWh]

3850 4850 5850 6850 78508

12

16

20

24

28

Pow

er [M

W]

Heat

rate

[MJ/k

Wh]

Ambient temperature [° C]

30

28

26

24

22

20

18

16

11.811.611.411.211.010.810.610.410.2

14.0

13.012.0

11.511.0

10.6

Heat rate [MJ/kWh]

PGDG-T10012-00-7600-Factsheet-SGT-600.indd 2 04.05.18 12:35