gas generators and...

16
Gas Generators and Co-generation MARCH 2011

Upload: others

Post on 24-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

Gas Generators and Co-generationMARCH 2011

Page 2: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

Meeting your emergency, standby, prime and continuous power generation needs with superior quality generator sets and complete power systems.

Broadcrown is a leading global manufacturer of high quality generator sets and a provider of complete power generation systems.

We have over 30 years experience in power generation. We are trusted to deliver a wide range of standard and bespoke systems – from diesel generators to Uninterruptible PowerSupplies (UPS) – plus turnkey power supply solutions, worldwide.

Broadcrown was one of the first power generation companies to be approved to ISO 9001 standards and quality drives every aspect of our business.

Our superior designs use high quality components throughout; not just in the generator sets but also the baseframes, canopies, containers and control panels.

Our full product range of single units extends from 11kVA to 4042kVA. All units can be combined to meet the requirements of larger projects for a broad range of applications delivering standby, prime or continuous power.

We will work with you to implement any product modifications that you may need specifically for your project.

Our generator set range includes:

• Diesel and gas powered• Trailer mounted, diesel powered• Gas and co-generation• Oil and gas• Marine• Medium speed• Gas turbines• Bespoke• Rental

We also provide a wide range of static and rotary Uninterruptible Power Supply (UPS) systems.

Page 3: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

1

OpTIOnSA comprehensive selection of mechanical and electrical options are available for every range.

We develop and supply canopies, weatherproof enclosures and container packages for outdoor all-weather use in the harshest of environments with acoustic performance to meet the most stringent specification.

aCOuSTIC paCkaGeS

All generator sets are supplied with a comprehensive digital control panel offering a user-friendly interface as standard. Further options are available providing even greater control system flexibility.

COnTROl panelS

Gas generators and co-generationSuperior quality generator sets from 11kVA to 4042kVA.

We offer a very wide range of high quality gas generator sets. We also offer a totally bespoke service to enable you to comply with the most onerous technical specification. Contact our sales department or local regional sales office.

BeSpOke SOluTIOnS

This brochure provides the main specifications and the options available for models in our gas and co-generation product ranges.

More information on our comprehensive product range plus technical updates can be found on our website www.broadcrown.com

Page 4: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

All generator model designations begin with the prefix BC. The following letter(s) are used to indicate the manufacturer of the engine on which the generator is based.For example — Lister: BClMAN: BCMnPerkins: BCpGuascor: BCGuCummins: BCCMTU: BCMuWaukesha: BCWa

The next part of the designation is a number which represents the rating of the generator followed by a frequency, thus — [max continuous rating in kWe] – 50

The final part of the designation indicates the fuel type, thus —nG: Natural GasBG: Biogas [landfill, anaerobic digester etc.]pG: Propane

Generator set designations and definition of ratings

BC MN 70 50 NG-STanDaRD

pRefIx

Summary

enGIneManufaCTuRe

L: Lister, MN: MAN P: Perkins, GU: Guascor,

WA: WaukeshaC: Cummins, MU: MTU

MaxIMuM kWe(1.0pf)

fRequenCy50Hz or 60Hz

fuel TypeNG: Natural gas, BG: Biogas or PG: Propane

2

Page 5: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

The Broadcrown standard 50Hz gas ranges incorporate natural gas power ratings from 9kWe to 3234kWe. The standard 60Hz gas ranges incorporate natural gas power ratings from 9.3kWe to 2849kWe.

As an independent design and manufacturer, both our 50Hz and 60Hz standard ranges use high quality engines and superior components from several world-renowned manufacturers. As a manufacturer-direct provider we can also work with you to develop complete bespoke solutions to meet your precise needs.

Broadcrown offers a comprehensive range of optional features for all ranges while maintaining common concepts across the power bands making installation and maintenance straightforward.

We ensure that our multi-generator packages are straightforward to use by offering a range of configurable electronic controllers. These increase in sophistication from simple auto-start function to multi-set paralleling and load sharing installations.

Our concentration on high quality, throughout, ensures that all our generator sets run efficiently and economically with low emissions over the course of a long working life providing excellent value for money.

Standard gas generators Broadcrown gas generator sets are manufactured to the same exacting standards as the diesel generator sets we have been designing and producing for over 30 years.

3

Page 6: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

4

9kWe to 3234kWe (11kVa to 4042kVa) generator setsnaTuRal GaS RanGe 50Hz 500mg/Nm3 NOx

single units can be combined for greater power

3 pHaSe 380/220 – 415/240VContinuous Rating

(COp)engine Specifications

Genset Model Engine Manufacturer kWe kVA Engine Model Cylinder Arrangement

Cubic Capacity(litres)

Fuel Cons100% Load (m3/h)

Alternator Model

BCl 9-50-nG Lister Petter 9 11 LPWG3 3 in line 1.4 2.9 BCAI164CBCl 12-50-nG Lister Petter 12 15 LPWG4 4 in line 1.8 4.3 BCAI164DBCl 10-50-pG * Lister Petter 10.5 13 LPWG3 3 in line 1.4 1.8 BCAI164CBCl 14-50-pG * Lister Petter 14 18 LPWG4 4 in line 1.8 2.3 BCAI164EBCMn 35-50-nG MAN 35 44 E0834 E312 4 in line 4.6 11 UCI 224 DBCMn 45-50-nG MAN 45 56 E0834 E312 4 in line 4.6 12 UCI 224 EBCMn 51-50-nG MAN 51 64 E0834 E302 4 in line 4.6 15 UCI 224 FBCMn 53-50-nG MAN 53 66 E0836 E312 6 in line 6.9 11 UCI 224 FBCMn 64-50-nG MAN 64 80 E0834 LE302 4 in line 4.6 15 UCI224GBCMn 71-50-nG MAN 71 89 E0836 E302 6 in line 6.9 21 UCI 274 CBCMn 105-50-nG MAN 105 131 E0836 LE202 6 in line 6.9 29 UCI 274 EBCMn 133-50-nG MAN 133 166 E2876 E302 6 in line 12.8 38 UCI 274 GBCMn 143-50-nG MAN 143 179 E2876 E312 6 in line 12.8 40 UCI 274 GBCMn 200-50-nG MAN 200 250 E2876 LE302 6 in line 12.8 55 HCI 444 CBCMn 238-50-nG MAN 238 298 E2842 E312 12 vee 21.9 67 HCI 444 DBCMn 252-50-nG MAN 252 315 E2848 LE322 8 vee 14.6 68 HCI 444 EBCMn 380-50-nG MAN 380 475 E2842 LE312 12 vee 21.9 93 HCI 544 C/DBCMn 399-50-nG MAN 400 500 E2842 LE322 12 vee 21.9 104 HCI 544 DBCp 306-50-nG Perkins 306 383 4006-23TRS1 6 in line 22.9 85 HCI 444 FBCp 375-50-nG Perkins 374 467 4006-23TRS2 6 in line 22.9 101 HCI 544 C/DBCp 425-50-nG Perkins 425 531 4008-30-TRS1 8 in line 30.6 116 HCI 544 D/EBCp 500-50-nG Perkins 500 625 4008-30TRS2 8 in line 30.6 135 HCI 544 FBCp 875-50-nG Perkins 875 1094 4016-61TRS1 16 vee 61.1 237 HCI 634 KBCp 1000-50-nG Perkins 1000 1250 4016-61TRS2 16 vee 61.1 268 PI 734 A/BBCGu 500-50-nG Guascor 500 625 HGM 240 8 in line 24.0 115 HCI544FBCGu 600-50-nG Guascor 600 750 SFGLD 360 12 vee 35.9 154 HCI634HBCGu 810-50-nG Guascor 810 1012 SFGLD 480 16 vee 47.9 206 PI734ABCGu 955-50-nG Guascor 955 1194 SFGLD 560 16 vee 56.3 241 PI734BBDGu 1020-50-nG Guascor 1020 1275 SFGM 560 16 vee 56.3 255 PI734BBCGu 1200-50-nG Guascor 1200 1500 HGM 560 16 vee 56.3 286 PI734DBCC 995-50-nG Cummins 995 1244 QSK 60 16 vee 60.3 240 PI 734 A/BBCC 1160-50-nG Cummins 1160 1450 QSK 60 16 vee 60.3 276 PI 734 CBCC 1400-50-nG Cummins 1400 1750 QSK 60 16 vee 60.3 316 PI 734 EBCC 1540-50-nG Cummins 1540 1925 QSV 91 18 vee 91.6 382 PI 734 FBCC 1750-50-nG Cummins 1750 2188 QSV 91 18 vee 91.6 423 PI 734 GBCC 2000-50-nG Cummins 2000 2500 QSV 91 18 vee 91.6 459 LV 804 SBCMu 849-50-nG MTU 849 1061 8V 4000 G63 8 vee 38.1 204 HCI 634 KBCMu 1286-50-nG MTU 1286 1608 12V 4000 G63 12 vee 57.2 308 PI 734 DBCMu 1711-50-nG MTU 1711 2139 16V 4000 G63 16 vee 76.3 411 PI 734 GBCMu 2145-50-nG MTU 2145 2681 20V 4000 G63 20 vee 95.3 516 LV 804 SBCWa 1016-50-nG Waukesha 1016 1270 16V150LTD 16 vee 47.9 232 PI734BBCWa 2156-50-nG Waukesha 2156 2695 APC2000 12 vee 109.5 496 LV804SBCWa 3234-50-nG Waukesha 3234 4042 APC3000 18 vee 164.2 745 on enquiry

RaTInG DefInITIOnS

Continuous (COp)Fuel Stop Power; Not overloadable, in accordance with ISO 3046/1 /BS5514/1, based on natural gas fuel. * Propane Fuel

STanDaRD RefeRenCe COnDITIOnS

Output ratings are based on generators operating at 25oC (77oF) air inlet temperature, 100 kPa barometric pressure and 30% relative humidity. For de-rating, please consult Broadcrown Sales Department. Fuel Consumptions vary according to emissions requirements.Territory restrictions may apply to some products.

Page 7: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

32kWe to 2000kWe (40kVa to 2500kVa) generator setsBIO GaS RanGe 50Hz

optimal performance with excellent fuel economy

3 pHaSe 380/220 – 415/240VContinuous Rating

(COp)engine Specifications

Genset Model Engine Manufacturer kWe kVA Engine Model Cylinder Arrangement

Cubic Capacity(litres)

Fuel Cons100% Load (m3/h)

Alternator Model

BCMn 32-50-BG MAN 32 40 E0834 E312 4 in line 4.6 14 UCI 224 DBCMn 51-50-BG MAN 51 64 E0836 E312 6 in line 6.9 22 UCI 224 FBCMn 105-50-BG MAN 104 130 E0836 LE202 6 in line 6.9 44 UCI 274 EBCMn 124-50-BG MAN 124 155 E2876 TE302 6 in line 12.8 56 UCI 274 FBCMn 190-50-BG MAN 190 238 E2876 LE302 6 in line 12.8 80 UCI 274 GBCMn 252-50-BG MAN 252 315 E2848 LE322 8 vee 14.6 109 HCI 444 EBCMn 342-50-BG MAN 342 428 E2842 LE312 12 vee 21.9 148 HCI 544 CBCMn 361-50-BG MAN 361 451 E2842 LE322 12 vee 21.9 158 HCI 544 CBCp 306-50-BG Perkins 306 383 4006-23TRS1 6 in line 22.9 139 HCI 444 FBCp 375-50-BG Perkins 374 467 4006-23TRS2 6 in line 22.9 165 HCI 544 C/DBCp 425-50-BG Perkins 425 531 4008-30-TRS1 8 in line 30.6 189 HCI 544 D/EBCp 500-50-BG Perkins 500 625 4008-30TRS2 8 in line 30.6 219 HCI 544 FBCp 600-50-BG Perkins 600 750 4012TESI 12 vee 45.8 282 HCI 634 GBCp 875-50-BG Perkins 875 1094 4016-61TRS1 16 vee 61.1 320 HCI 634 KBCp 1000-50-BG Perkins 1000 1250 4016-61TRS2 16 vee 61.1 358 PI 734 ABCGu 300-50-nG Guascor 300 375 SFGLD 180 6 in line 18.0 122 HCI444FBCGu 400-50-nG Guascor 400 500 SFGLD 240 8 in line 24.0 165 HCI544EBCGu 500-50-nG Guascor 500 625 HGM 240 8 in line 24.0 184 HCI544FBCGu 605-50-nG Guascor 605 756 SFGLD 360 12 vee 35.9 245 HCI634GBCGu 810-50-nG Guascor 810 1012 SFGLD 480 16 vee 47.9 329 HCI634KBCGu 955-50-nG Guascor 955 1194 SFGLD 560 16 vee 56.3 385 PI734BBCGu 1020-50-nG Guascor 1020 1275 SFGM 560 16 vee 56.3 407 PI734CBCGu 1200-50-nG Guascor 1200 1500 HGM 560 16 vee 56.3 456 PI734DBCC 1160-50-BG Cummins 1160 1450 QSK60 16 vee 60.3 * PI7 34CBCC 1400-50-BG Cummins 1400 1750 QSK60 16 vee 60.3 * PI 734 EBCC 1540-50-BG Cummins 1540 1925 QSV91 18 vee 91.6 * PI 734 FBCC 1750-50-BG Cummins 1750 2188 QSV91 18 vee 91.6 * PI 734 GBCC 2000-50-BG Cummins 2000 2500 QSV91 18 vee 91.6 * LV 804 S

RaTInG DefInITIOnS

Continuous (COp)Fuel Stop Power; Not overloadable, in accordance with ISO 3046/1 /BS5514/1, based on biogas approx 60% CH4 / 40% CO2. * Provisional consumption provided on receipt of gas

analysis.

STanDaRD RefeRenCe COnDITIOnS

Output ratings are based on generators operating at 25oC (77oF) air inlet temperature, 100 kPa barometric pressure and 30% relative humidity. For de-rating, please consult Broadcrown Sales Department. Fuel consumptions vary according to emissions requirements.Territory restrictions may apply to some products.

5

Page 8: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

6

9.3kWe to 2849kWe (11.6kVa to 3561kVa) generator setsnaTuRal GaS RanGe 60Hz 500mg/Nm3 NOx

superior designs, precision components

3 pHaSe 440/254 – 480/277VContinuous Rating

(COp)engine Specifications

Genset Model Engine Manufacturer kWe kVA Engine Model Cylinder Arrangement

Cubic Capacity(litres)

Fuel Cons100% Load (m3/h)

Alternator Model

BCL 9-60-NG Lister 9.3 11.6 LPWG3 3 in line 1.4 3.7 BCAI 164 CBCL 12-60-NG Lister 12.5 15.6 LPWG4 4 in line 1.8 5.3 BCAI 164 DBCL 11-60-PG * Lister 11.7 14.6 LPWG3 3 in line 1.4 1.8 BCAI 164 CBCL 16-60-PG * Lister 15.8 19.8 LPWG4 4 in line 1.8 2.3 BCAI 164 DBCMN 43-60-NG MAN 43 54 E0834 E312 4 in line 4.6 14 UCI 224 DBCMN 50-60-NG MAN 50 62 E0834 E312 4 in line 4.6 15 UCI 224 DBCMN 59-60-NG MAN 59 74 E0834 E302 4 in line 4.6 16 UCI 224 FBCMN 61-60-NG MAN 61 76 E0836 E312 6 in line 6.9 23 UCI 224 FBCMN 81-60-NG MAN 81 101 E0836 E302 6 in line 6.9 23 UCI 274 CBCMN 105-60-NG MAN 105 131 E0836 LE202 6 in line 6.9 30 UCI 274 DBCMN 162-60-NG MAN 162 202 E2876 E312 6 in line 12.8 45 UCI 274 GBCMN 200-60-NG MAN 200 250 E2876 LE302 6 in line 12.8 56 HCI 444 CBCMN 266-60-NG MAN 266 332 E2842 E312 12 vee 21.9 75 HCI 444 DBCMN 280-60-NG MAN 280 350 E2848 LE322 8 vee 14.6 78 HCI 444 DBCMN 418-60-NG MAN 418 522 E2842 LE322 12 vee 21.9 108 HCI 544 CBCGU 335-60-NG Guascor 335 419 SFGLD 180 6 in line 18.0 87 HCI444FBCGU 435-60-NG Guascor 435 544 SFGLD 240 8 in line 24.0 117 HCI544EBCGU 675-60-NG Guascor 675 844 SFGLD 360 12 vee 35.9 174 HCI634HBCGU 870-60-NG Guascor 870 1087 SFGLD 480 16 vee 47.9 234 HCI634JBCGU 1060-60-NG Guascor 1060 1325 SFGM 560 16 vee 56.3 270 PI734ABCGU 1305-60-NG Guascor 1305 1631 HGM 560 16 vee 56.3 315 PI734CBCC 1000-60-NG Cummins 1000 1250 QSK 60 16 vee 60.3 228 PI 734 ABCC 1100-60-NG Cummins 1100 1375 QSK 60 16 vee 60.3 250 PI 734 ABCC 1250-60-NG Cummins 1250 1563 QSK 60 16 vee 60.3 313 PI 734 BBCC 1400-60-NG Cummins 1400 1750 QSK 60 16 vee 60.3 362 PI 734 CBCC 1750-60-NG Cummins 1750 2188 QSV 91 18 vee 91.6 437 PI 734 EBCC 2000-60-NG Cummins 2000 2500 QSV 91 18 vee 91.6 482 PI 734 FBCWA 1117-60-NG Waukesha 1117 1396 16V150LTD 16 vee 47.9 261 PI734BBCWA 1897-60-NG Waukesha 1897 2371 APC 2000 12 vee 109.5 426 on requestBCWA 2849-60-NG Waukesha 2849 3561 APC 3000 18 vee 164.2 720 on request

RaTInG DefInITIOnS

Continuous (COp)Fuel Stop Power; Not overloadable, in accordance with ISO 3046/1 /BS5514/1, based on natural gas fuel. * Propane Fuel

STanDaRD RefeRenCe COnDITIOnS

Output ratings are based on generators operating at 25oC (77oF) air inlet temperature, 100 kPa barometric pressure and 30% relative humidity. For de-rating, please consult Broadcrown Sales Department. Fuel Consumptions vary according to emissions requirements. Other 60Hz combinations may be available.Territory restrictions may apply to some products.

Page 9: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

38kWe to 2000kWe (48kVa to 2500kVa) generator setsBIO GaS RanGe 60Hz

the ultimate in reliable power generation

3 pHaSe 440/254 – 480/277VContinuous Rating

(COp)engine Specifications

Genset Model Engine Manufacturer kWe kVA Engine Model Cylinder Arrangement

Cubic Capacity(litres)

Fuel Cons100% Load (m3/h)

Alternator Model

BCMn 38-60-BG MAN 38 48 E0834 E312 4 in line 4.6 17 UCI 224 DBCMn 55-60-BG MAN 55 69 E0836 E312 6 in line 6.9 24 UCI 224 FBCMn 105-60-BG MAN 105 131 E0836 LE202 6 in line 6.9 45 UCI 274 EBCMn 190-60-BG MAN 190 238 E2876 LE302 6 in line 12.8 77 UCI 274 GBCMn 252-60-BG MAN 252 315 E2848 LE322 8 vee 14.6 116 HCI 444 EBCMn 342-60-BG MAN 342 428 E2842 LE312 12 vee 21.9 153 HCI 544 CBCGu 335-60-BG Guascor 335 419 SFGLD180 6 in line 18.0 140 HCI 444FBCGu 435-60-BG Guascor 435 544 SFGLD 240 8 in line 24.0 187 HCI 544EBCGu 675-60-BG Guascor 675 844 SFGLD 360 12 vee 35.9 278 HCI 634HBCGu 870-60-BG Guascor 870 1087 SFGLD 480 16 vee 47.9 373 HCI 634JBCGu 1005-60-BG Guascor 1005 1256 HGM 560 ** 16 vee 56.3 379 PI734ABCGu 1060-60-BG Guascor 1060 1325 SFGM 560 16 vee 56.3 433 PI734ABCGu 1305-60-BG Guascor 1305 1631 HGM 560 16 vee 56.3 504 PI734CBCC 1000-60-nG Cummins 1000 1250 QSK 60 16 vee 60.3 * PI 734 ABCC 1100-60-nG Cummins 1100 1375 QSK 60 16 vee 60.3 * PI 734 CBCC 1250-60-nG Cummins 1250 1563 QSK 60 16 vee 60.3 * PI 734 EBCC 1400-60-nG Cummins 1400 1750 QSK 60 18 vee 91.6 * PI 734 FBCC 1750-60-nG Cummins 1750 2188 QSV 91 18 vee 91.6 * PI 734 GBCC 2000-60-nG Cummins 2000 2500 QSV 91 18 vee 91.6 * LV 804 S

RaTInG DefInITIOnS

Continuous (COp)Fuel Stop Power; Not overloadable, in accordance with ISO 3046/1 /BS5514/1, based on biogas approx. 60% CH4 40% CO2.

* Provisional consumption provided on receipt of gas analysis.** 1200rpm operation

STanDaRD RefeRenCe COnDITIOnS

Output ratings are based on generators operating at 25oC (77oF) air inlet temperature, 100 kPa barometric pressure and 30% relative humidity. For de-rating, please consult Broadcrown Sales Department. Fuel Consumptions vary according to emissions requirements.Territory restrictions may apply to some products.

7

Page 10: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

as a designer and manufacturer of generator sets, we have extensive experience in bespoke design, over the past 30 years, which ensures that we can build and modify generating or co-generation packages to suit your individual criteria.

These packages are specially designed to match exact site conditions and incorporate the same base gas generator set but with the addition of carefully selected project-specific items such as:

• Exhaust flues• Acoustic enclosures• Plate heat exchanger for water

systems• Shell & tube heat exchanger for

exhaust gas heat recovery• MV or HV alternator• Step-up transformer• Absorption chiller for ‘trigeneration’ • Comprehensive control and

monitoring plc panel

All Broadcrown’s co-generation packages achieve high system efficiencies to ensure that they qualify for full Climate Change Levy exemption on the electricity produced, and an Enhanced Capital Allowance.

Our co-generation packages are comprehensively project managed by our in-house Broadcrown experts and they are installed and commissioned by our own engineers, so that you have just one point of contact for the duration of the project.

Co-generation (Combined Heat & power) Broadcrown specialises in small-scale, high quality co-generation (CHP) packages runningoff natural gas, digester gas or landfill gas.

8

Page 11: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

comprehensive range of options available 9

35kWe to 3234kWe (37kVa to 3404kVa) generator setsCHp RanGe 50Hz 500mg/Nm3 NOx

RaTInG DefInITIOnS

Continuous (COp)Fuel Stop Power; Not overloadable, in accordance with ISO 3046/1 /BS5514/1, based on natural gas fuel.

STanDaRD RefeRenCe COnDITIOnS

Output ratings are based on generators operating at 25oC (77oF) air inlet temperature, 100 kPa barometric pressure and 30% relative humidity. For de-rating, please consult Broadcrown Sales Department. Emissions typically 500mg/Nm3 Nox. Fuel consumptions vary according to emissions requirements.For 60 Hz applications or alternative voltages please consult Broadcrown Sales Department.Territory restrictions may apply to some products.

3 pHaSe 380/220 – 415/240VContinuous Rating

(COp)Typical available Heat (kWth)

Genset Model Engine Manufacturer

kWe kVA(0.95PF)

Engine Model Jacket Water & Lub Oil Cooler

Exhaust (cooled to 120 degrees)

JW/Charge Cooler HT

Sum ofUsable Heat

Sum of Usable Energy (kW)

BCMn 35-50-nG MAN 35 37 E0834 E312 29 26 — 55 90BCMn 53-50-nG MAN 53 56 E0836 E312 41 37 — 78 131BCMn 64-50-nG MAN 64 67 E0834 LE302 55 34 — 89 154BCMn 105-50-nG MAN 104 109 E0836 LE202 68 64 6 138 242BCMn 200-50-nG MAN 200 210 E2876 LE302 99 143 21 263 463BCMn 252-50-nG MAN 252 265 E2848 LE322 150 145 26 321 573BCMn 380-50-nG MAN 380 400 E2842 LE312 230 237 — 467 847BCMn 399-50-nG MAN 400 421 E2842 LE322 236 222 55 513 913BCp 306-50-nG Perkins 306 322 4006-23TRS1 152 205 — 357 663BCp 375-50-nG Perkins 374 394 4006-23TRS2 162 239 — 401 775BCp 425-50-nG Perkins 425 447 4008-30-TRS1 189 279 — 468 893BCp 500-50-nG Perkins 500 526 4008-30TRS2 211 316 — 527 1027BCp 875-50-nG Perkins 875 921 4016-61TRS1 487 539 — 1026 1901BCp 1000-50-nG Perkins 1000 1053 4016-61TRS2 445 646 — 1091 2091BCC 995-50-nG Cummins 995 1047 QSK 60 — 573 509 1082 2077BCC 1160-50-nG Cummins 1160 1221 QSK 60 — 730 688 1418 2578BCC 1400-50-nG Cummins 1400 1474 QSK 60 — 741 759 1660 2900BCC 1540-50-nG Cummins 1540 1621 QSV 91 — 1050 610 2240 3200BCC 1750-50-nG Cummins 1750 1842 QSV 91 — 1600 640 2293 3290BCC 2000-50-nG Cummins 2000 2105 QSV 91 — 1144 1149 2246 4293BCMu 849-50-nG MTU 849 894 8V 4000 G63 455 475 — 930 1779BCMu 1286-50-nG MTU 1286 1354 12V 4000 G63 719 693 — 1412 2698BCMu 1711-50-nG MTU 1711 1801 16V 4000 G63 925 931 — 1856 3567BCMu 2145-50-nG MTU 2145 2258 20V 4000 G63 1125 1216 — 2341 4486BCWa 1016-50-nG Waukesha 1016 1069 16V150LTD 616 466 — 1082 2098BCWa 2156-50-nG Waukesha 2156 2269 APC2000 946 1252 — 2198 4354BCWa 3234-50-nG Waukesha 3234 3404 APC3000 1476 1846 — 3322 6556

Page 12: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

Specifications and Options Broadcrown offers a comprehensive range of mechanical and electrical options for all generator sets.

power management and load transfer panelsWe can provide bespoke power management systems as well as a range of automatic load transfer panels. These incorporate either 3 pole or 4 pole electrically and mechanically interlocked contactors or circuit breakers (from 25 amps to 6300 amps) which are CE or UL Compliant.

Special requirementsIf you do not see exactly what you want, contact our sales department or local regional sales office.

We can meet special requirements such as:• Generator sets in excess of 2150kWe

continuous power• Multi-set installations• HV generation• Stringent noise levels• Special acoustic enclosure design• Alternative engine and alternator

combinations

We will work with you to get you precisely the right power solution.

10

Page 13: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

acoustic packages Our acoustic packages are designed to operate in the harshest outdoorenvironments providing excellent security and acoustic performance.

acoustic canopies and enclosuresWe can provide a standard range of acoustic canopies for generator sets up to 700kVA.

finish All our steel canopy components are pre-treated and polyester powder coated (to a typical thickness of 70-80μm) in RAL9001 white and all baseframes are finished in RAL9005 black. These finishes, along with zinc-plated fasteners and neoprene seals, combine to produce a very durable and attractive finish.

performance Our canopies are designed to meet the requirements of EU Legislation 2000/14/EC. This performance level is met by the extensive use of fire-retardant polyurethane foam and efficient management of cooling air. Exhaust noise is minimized by high-performance silencers, mounted internally.

Typical features may include: • Gull-wing or side opening doors • Panel/breaker access door with

viewing window • Heavy duty locks on all doors • Weather cap on exhaust discharge • Emergency Stop button relocated to

canopy exterior • Lifting and holding down points • Fork Lift pockets (up to Canopy 4A) • Single roof lifting point (available on

certain models only)

11

Page 14: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

12

Control panelsOur control panels combine the ultimate in sophisticated operation with straightforward user interfaces.

Our control panels use modular and standard components specifically designed for bespoke generator sets or CHp units.

Control panelAll control panels can be set or remote mounted. They provide the highest degree of reliability and user friendly operation. The control panel contains an integrated generator set controller that combines all the necessary control, protection and instrumentation for a generator set in one compact unit. A comprehensive display of instrumentation, alarms and parameters is shown on a graphical LCD screen with the various alarms and control settings easily adjustable.

entry levelThe entry level is a remote start system, however, generator sets can be provided with alternative control panels offering Automatic Mains Failure (AMF) capability and synchronising facilities.

additional modelsFurther models include multi-set synchronisation and load-sharing functions together with single set-to-mains supply synchronisation, and multi-set-to-mains supply synchronisation. Protection is also available by the addition of an integrated protection relay for generator sets operating in parallel with the mains supply.

ControllersBroadcrown offers generator set controllers with additional facilities dependent on the model, such as MODBUS protocol for remote interrogation by BMS/SCADA systems, a 100+ record data log/history file for recording alarms/control events and an engine service interval timer to indicate engine service due date.

Please refer to the detailed specifications to check standard features and see what options are available.

BC 7210

Page 15: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

Broadcrown is independently owned and managed. When you contact us you are talking to friendly people who will work with you to meet your specific needs.

Our generator set range includes:• Diesel and gas powered• Trailer mounted, diesel powered • Gas and co-generation• Oil and gas• Marine• Medium speed • Gas turbines• Bespoke• Rental

We also provide a wide range of static and rotary Uninterruptible Power Supply (UPS) systems.

production facilitiesAll Broadcrown products are designed and manufactured in our purpose-built factories at our corporate headquarters in Hixon, England and in Newtown, Wales.

Brochures are available for all our products and services on our website, www.broadcrown.com

Broadcrown, broadcrown, their respective logos, the “crown” logo, as well as corporate and product identity used herein are trademarks of Broadcrown and may not be used without permission. BROADCROWN is a registered trademark of Broadcrown Holdings Plc.

Page 16: Gas Generators and Co-generationwrachtan.zut.edu.pl/project_agreg_kog/Broadcrown-9-xxkWe--chp/BC-Gas... · power generation needs with superior quality generator sets and complete

GROUP HEADQUARTERS

Broadcrown ltdairfield Industrial estate Hixon, Stafford Staffs ST18 0pfengland

tel: +44 (0) 1889 272200 fax: +44 (0) 1889 272220email: [email protected] www.broadcrown.com

INTERNATIONAL NETWORKOur growing international network of distributors backed by the Broadcrown Regional Support Centres of Miami, Singapore, Nigeria, South Africa, India and China, provides worldwide product availability and after sales support including training.

Broadcrown (China) ltdRoom 1503, Tower B, SOHO Newtown, 88 Jianguo Avenue, Chaoyang Dist., Beijing, China 100022tel: +86 (0) 10 8589 3698 fax: +86 (0) 10 8589 5771email: [email protected] www.broadcrownchina.com

Broadcrown Singapore pte ltd3791 Jalan Bukit Merah, #05-08, E-Centre @ Redhill, Singapore 159471tel: +65 6235 3630 fax: +65 6732 4355email: [email protected] www.broadcrownsingapore.com Broadcrown (West africa) ltd4/6 Kudirat Abiola Way, Alausa, Ikeja, Lagos, Nigeriatel: +234 1 761 7107 email: [email protected] www.broadcrownwestafrica.com

Broadcrown Sa (pty) limitedOffice Address: Unit 1 Atom Park, Neutron Street, Stikland 7530, South AfricaPostal Address: PO Box 1065, Durbanville 7551, South Africatel: +27 21 946 3463 fax: +27 21 946 3953 email: [email protected] www.broadcrownsouthafrica.com

Broadcrown Inc.9705 NW 108th Avenue, Suite 10, Miami, Florida 33178, USAtel: +1 305 888 1414 fax: +1 305 888 1801email: [email protected] www.broadcrownusa.com

Broadcrown India (pVT) ltdR-06 A, 3rd Floor, MGF Plaza, Mehrauli-Gurgaon Road, Gurgaon – 122002, Haryana, Indiaemail: [email protected] www.broadcrownindia.com

www.broadcrown.com