  • 8/19/2019 Gama Dimat Catalog Be17

    1/16

    Solutions born from

    experience

     Product Guide

  • 8/19/2019 Gama Dimat Catalog Be17

    2/16

    DIMAT

  • 8/19/2019 Gama Dimat Catalog Be17

    3/16

      , is situated in Barcelona and since it was

    set up in 1967 it has been a leading designer and

    manufacturer of communications and networking

    solutions for power utilities.

      is a company of the Group, whose

    headquarters are in Zamudio (Vizcaya) and is made

    up of a group of companies with its own technology,

    suppliers of terminals and services for the electrical,

    energy, rail and telecommunications sectors.

    This new general catalogue of includes,

    from systems and equipment that demonstrates its

    efficiency and reliability, to the state-of-the-art

    equipment made with the latest technology and

    guaranteed by long design experience. They are all

    competitive offers that include unique products with

    industry-leading reliability developed with its own

    technology.

    Furthermore, as an indication of its innovative

    commitment, has a highly qualified R+D

    team that makes up over 30% of the company staff,

    and is active member of several recognized

    international organizations (CIGRE, IEC, IEEE…).

     All this, borne out by our clients with installations all

    over the world, assures and explains why is

    still one of the world leaders in the field of 

    telecommunication terminals for utilities, always being

    the first to market new products and technology.

    Javier Osés

    General Manager 

  • 8/19/2019 Gama Dimat Catalog Be17

    4/16

    4

    OPU-1

    Modular design and extensive features

     The use of the most advanced technology indigital signal processing together with DIMAT'swide experience in digital and analog power-line carrier terminals have resulted in a highlyflexible, robust and reliable Universal Power-Line Carrier terminal.

     The modular design of the OPU-1 terminal andadvanced features ensure a perfect fit to everyuser need. It can integrate a great variety of interfaces that allow the transmission of all typeof services through high-voltage lines.

     This modularity allows OPU-1 terminals totransmit analog, digital or both analog anddigital channels simultaneously, includingteleprotection if be the case.

    When working with analog channels, the OPU-1terminal can transmit one or two 4 kHz standardchannels in each direction. The effective bandof the channel can be used for the transmissionof data at high speed, various VF telegraphchannels, teleprotection signals or for a speech-plus service.

    When working with a digital channel, the OPU-1terminal can support two different digitalmodulation schemes (QAM or OFDM).

    When using QAM, it offers a transmission rateof 81 kbit/s in a bandwidth of 16 kHz, in eachdirection. Thanks to the use of a built-in echo

    canceller, the transmission and reception bandscan be superimposed, resulting in a totalbandwidth of 16 kHz. A bandwidth of 8 kHz isalso possible, single for superimposed bandsor in each direction for non-adjacent bands.

    UniversalPower-Line Carrier Terminal

    With the OFDM digital modulation scheme, theOPU-1 terminal can support a maximum

    transmission rate of 256 kbit/s in a bandwidthof 32 kHz, in each direction.

     The OPU-1 terminal can transmit in separatedbands using different frequency slots in thesame high-voltage line or even independentlines. In this case, an additional high-frequencyline filter is required. Apart from frequencycongestion solution, this additional filter allowsspecial topology applications like Teed lines.

     The digital user interface can be chosen froma number of different possibilities: Ethernet,G.703, V.35, V.11 and V.24/V.28.

    One remarkable feature of the OPU-1 terminalis the automatic fall-back rate when there is

    unfavourable line noise and/or signal reflectionconditions. When the line conditions improve,the transmission rate is automatically re-established. This feature can be disabled fromthe programming software if necessary.

    Furthermore, the OPU-1 terminal offers thepossibility of using the FEC (Forward ErrorCorrection) built-in optional functionality whenthe link quality is unsatisfactory. The link qualitymeasurement is based on the G.821 standardconcepts.

    When using the OPU-1 terminal for theinterconnection of different line segments, abuilt-in Ethernet bridge selects the frames to

    be transmitted to the remote end, thus makinga more efficient use of the communicationschannel.

    OPU-1

    4

  • 8/19/2019 Gama Dimat Catalog Be17

    5/16

    5

    DIMAT

     The terminal has an internal service channelthat can be connected in cascade with the

    internal service channel of different OPU-1 links. This is a useful feature that makes the remotemanagement of the OPU-1 terminals possiblewhen not all of them have the possibility of connection to an IP network.

     The OPU-1 terminals, furthermore, include anSNMP agent that makes it possible to remotelymonitor them via IP network, from anymanagement platform.

    Key features:

    · Modular design· Simultaneous transmission of analog and

    digital channels including teleprotection

    · Frequency range of 36 kHz to 512 kHz (from24 kHz to 1 MHz upon request)

    · QAM or OFDM for best compromise betweenSNR, BW and transmission rate

    · Independent bands to overcome congestionsolution and special topology applications

    · 10 ms internal latency in QAM mode· Fully programmable (full coverage of the

    transmission frequency range with a singleset of capacitors)

    · Automatic fall back/increase rates· Integrated optional Reed-Solomon FEC· Integrated G.821 statistics· Ethernet user interface with built-in bridge

    functionality

    · Redundant power supply (optional)· 1 or 2 standard 4 kHz channels in each

    direction plus a large variety of analog options:speech module, asynchronous programmablemodem, synchronous and asynchronousconfigurable modem, 2 or 4-commandteleprotection system using tones in a 4 kHzor 2 kHz bandwidth, digital transit filter, inputan output combiner, etc.

    · 81 kbit/s in 16 kHz bandwidth (QAM) plus anoptional internal TDM multiplexer

    · 256 kbit/s in 32 kHz bandwidth in eachdirection (OFDM)

    · 20, 40 or 80 W PEP, shared between theanalog and digital channels

    · Compact 19"/9 s.u. shelf for 20 W and 40 W· An additional 19"/3 s.u. shelf for 80 W or an

    extra line filter· SNMP agent

    · Web Management system with LANconnection

    · Cascaded internal service channel· IRIG-B port for GPS time synchronization· Chronological register (1000 alarms and

    events) with 1 ms resolution

    Its modular

    design and

    extensive features

    ensure a perfect

    fit to every user

    need

    Rear view

  • 8/19/2019 Gama Dimat Catalog Be17

    6/16

    6

    OPC-2

     A simple and reliable solution for PLCnetworks with frequency congestion

     The OPC-2 is a highly flexible platform that isconceived with a dual purpose: Power-LineCarrier functionality or, alternately, Narrow-BandHigh-Frequency Teleprotection functionality.

     The required OPC-2 functionality is establishedby simply configuring some microswitches inthe management & process unit and line filtermodules.

     The output power (20, 40 or 80 W P.E.P.)determines the OPC-2 platform version. 20 Wand 40 W versions are integrated in a single 6s.u. shelf, while an additional 3 s.u. shelf isrequired in 80 W versions.

     All OPC-2 versions can be equipped with aredundant power-supply module.

    Power-Line Carrier Functionality 

     The Power-Line Carrier functionality is a well-proven, cost effective solution to enableelectrical power utilities to use high-voltagelines to transmit different types of information(telecontrol data, speech and teleprotectionsignals) over long distances, using one or twostandard 4 kHz channels in each direction.

     A large variety of optional modules can beadded to an OPC-2 platform with PLC

    functionality. Examples include: a speechmodule, a 2 or 4-command teleprotectionsystem, an asynchronous programmablemodem, a digital transit filter and an input/outputcombiner. When equipped with the optionalsynchronous and asynchronous configurablemodem, the effective band of the channel canbe used exclusively for transmission of synchronous or asynchronous data at a speedof up to 28.8 kbit/s.

    Multi-function platform

    HF Teleprotection Functionality 

     The High-Frequency Teleprotection functionalityenables electrical power utilities to transmitteleprotection commands between protectionrelays over high-voltage lines in a single 4 kHzbandwidth, using 2 kHz for transmission and2 kHz for reception.

     The OPC-2 plat form allows three nominaltransmission times to be programmed. Thesystem meets the security and dependabilityrequirements specified in IEC 60834-1Recommendation for the three types of teleprotection command schemes: Permissivetripping schemes, Intertripping schemes (Director transfer tripping) and Blocking protectionschemes.

    OPC-2

  • 8/19/2019 Gama Dimat Catalog Be17

    7/16

    7

    DIMAT

    PLC application characteristics

    · Versions for data transmission (D-type) or forspeech-plus transmission (T-type)· Single and twin-channel versions· Erect or inverted, adjacent or non-adjacentprogrammable bands

    · Available band of 300 to 3850 Hz with pilottone out of band

    · Service telephony channel· Optional modules:

    - Asynchronous programmable modem- Synchronous and asynchronousconfigurable modem

    - 2 or 4-command teleprotection system bytones for a 4 kHz bandwidth

    - 2 or 4-command teleprotection system byFSK channels for a 4 kHz bandwidth

    - Speech

    - Digital transit filter- Input/Output combiner

    · Meets International Recommendation  IEC 60495, regarding PLC equipment

    TP application characteristics

    · 2-command and 4-command versions· Only one standard 4 kHz channel (2 kHz for Tx and 2 kHz for Rx) is needed· Guard and command frequencies located inthe 300-2000 Hz band

    · High dependability and extremely high security· Meets Recommendation IEC 60834-1regarding teleprotection systems

    · Intended for blocking, direct tripping and

    permissive tripping schemes as well as fortelesignalling· Three programmable nominal transmissiontimes depending on application

    · From 1 to 4 command inputs (optocoupled)· From 1 to 4 command outputs by solid-staterelay, with voltage-free contact and currentlimitation

     A single platform

    with two

    applications:Power-Line Carrier

    functionality 

    (telecontrol data,

    speech and

    teleprotection

    signals) or Narrow-

    Band High-

    Frequency 

    Teleprotection

    functionality 

    Rear view

    Key features

    · Intelligent bandwidth use· A single 6 s.u. shelf for 20 or 40 W· Single side-band (SSB) with suppressed carrier· Frequency range of 36 kHz to 508 kHz· Fully programmable (full coverage of thetransmission frequency range thanks to theset of capacitors)

    · IRIG-B port for GPS time synchronization· Chronological register (1000 alarms andevents) with 1 ms resolution

    · Web Management System with LANconnection for both functionalities

    · Internal channel for end-to-end supervision· Redundant power supply (optional)· 3 programmable alarm relays and 1 relay perpower supply

  • 8/19/2019 Gama Dimat Catalog Be17

    8/16

    OPL-1

    High reliability and robustness

     The OPL-1 analog Power-Line Carrier terminalis an extremely compact equipment where allthe basic operating elements are contained inonly four main modules.

     The basic terminal has one standard 4 kHz channelwith an output power (PEP), measured at thecoaxial-connector output, of 20 W or 40 W.

     The twin-channel version of the OPL-1 terminalcan be supplied on demand, the use of bothchannels having to be specified.

    Both types, single-channel and twin-channel,allow teleprotection commands proceedingfrom an external analog teleprotection unit tobe transmitted.

     As far as optional equipment is concerned,apart from the speech module and the externalanalog teleprotection unit, an asynchronous

    programmable narrowband modem can beadded to the OPL-1 terminal. Furthermore, an AF transit option can be configured from theManagement System.

    Key features

    · Compact design· A single 5 s.u. shelf · 20 W or 40 W PEP· Single side-band (SSB) with suppressed carriermodulation

    · Single-channel and, optionally, twin-channel· Frequency range of 40 kHz to 500 kHz· Fully programmable (full coverage of thetransmission frequency range thanks to theset of capacitors)

    · 3 programmable alarm relays· IRIG-B port for GPS time synchronization· Chronological register (1000 alarms andevents) with 1 ms resolution

    · Internal channel for end-to-end supervision· Local management system based on a Webinterface

    · Integrated options: speech, AF transit and anasynchronous programmable modem

    · Optional external analog teleprotection unit· Optional external connection by means of cabinet-mounting terminal blocks

    Compact AnalogPower-Line Carrier Terminal

    OPL-1

    8

    OPD-2+

    31.2 kbit/s using the same bandwidth ofanalog PLC systems

     The DIMAT OPD-2+ system is the result of thecombination of the well-proven OPC-2 terminaltogether with a high-performance digitalmultiplexer. Thanks to that, the DIMAT OPD-2+

    makes the most of the advantages of the voiceand data multiplexing in the 4+4 kHz or 8+8kHz bandwidth of the single or twin-channelanalog PLC's.

     There are two models of the OPD-2+ terminal,single-channel and twin-channel, with a rangeof output power of 20, 40 or 80 W PEP.

    OPD-2+ single-channel terminals can beequipped with up to four ports, two for dataand two for voice, with a transmission speedof up to 31.2 kbit/s in total.

    OPD-2+ twin-channel terminals can beequipped with twice the ports of the single-

    channel terminal, with a transmission speed of up to 31.2+31.2 kbit/s, or even with the portsof the single-channel terminal plus one 4 kHzanalog audio channel, for the cases on whichdigital signals and analog signals have to betransmitted in the same link.

     The OPD-2+ can also be equipped with a built-in teleprotection system of up 4 commands.

    Key features

    · Built-in multiplexer for voice and data· 20 W, 40 W and 80 W PEP· Frequency range of 36 kHz to 508 kHz· QAM modulation combined with single side-band modulation with suppressed carrier

    modulation· Fully programmable (full coverage of thetransmission frequency range thanks to theset of capacitors)

    · Erect or inverted, adjacent or non-adjacentprogrammable bands

    · 31.2 kbit/s in single-channel terminals and31.2 kbit/s + 31.2 kbit/s in twin-channelterminals

    · IRIG-B port for GPS time synchronization· Chronological register (1000 alarms andevents) with 1 ms resolution

    · Web management system with LANconnection (the management of the multiplexerfunctions is carried out locally and by meansof a Windows-based software)

    · Internal channel for end-to-end supervision· Redundant power supply (optional)

    · 3 programmable alarm relays and 1 relay perpower supply

    · Optional built in teleprotection system of upto 4 commands

    DigitalPower-Line Carrier Terminal

    OPD-2+

  • 8/19/2019 Gama Dimat Catalog Be17

    9/16

    9

    DIMAT

    DIMAT also has

    additional terminals

    for Power-lineCarrier Systems

    OPD-1

    79 kbit/s fully available for the user in abandwidth of 16 kHz

    Digital Power-Line Carrier technology provideshigh performance against channel impairments,high traffic-handling capacity, and easyintegration into existing analog Power-Line

    Carrier networks. It represents a simple andreliable solution to the increasing demand forcommunication channels in power utilities andto the problem of frequency spectrumcongestion of Power-Line Carrier networks.

    DIMAT OPD-1 terminals have a gross bit rateof 81 kbit/s, being 79 kbit/s available for theuser.

     The base configuration of the OPD-1 terminalincludes two ports: one for synchronous dataat a maximum transmission speed of 72 kbit/s,and the other for asynchronous data at amaximum speed of 14400 bit/s.

     The number of available ports can be increasedto a maximum of 11 using an optional internalmultiplexer. This consists of up to threeadditional modules with up to three ports each.

     These ports can be either for speech or data,providing maximum flexibility for each customer.

    Upgrade options include a built-in teleprotectionsystem of up to 4 commands that does notreduce the transmission capacity.

    Key Features

    · Frequency range of 40 kHz to 500 kHz· QAM with Trellis coding modulation· Fully programmable (full coverage of the

    transmission frequency range thanks to theset of capacitors)

    · Superimposed or non-adjacent 16 kHztransmission and reception bands

    · Programmable at 3 different gross bit rates:81 kbit/s, 40.5 kbit/s and 27 kbit/s

    · 79 kbit/s, 39.5 kbit/s or 26.3 kbit/s fullyavailable for the user

    · 10 ms internal latency and of 15 ms withinternal multiplexer

    · Local management system based on a Webinterface and optional Web management shelf with LAN connection

    · Internal channel for end-to-end supervision· Service telephony channel· 4 programmable alarm relays· Optional modules:

    - Built-in multiplexer for up to 9 speech and/ordata ports

    - Teleprotection system of up to 4 commands

    DigitalPower-Line CarrierTerminal

    OPD-1

    MAFP and MQBT 

    MAFP and MQBT

     The MAFP is an asynchronous narrowbandmodem with frequency-shift keying (FSK)modulation for the transmission of data atspeeds of 50 to 1200 Bd. The technology usedin the MAFP modem is based on digital signal

    processing and allows the transmission speedand central frequency of each channel to beprogrammed by the user. The MAFP modemis capable of operating at 1200 Bd insuperimposed band and, in this way, share thechannel of the PLC terminal with speechfrequencies up to 2000 Hz and with a DIMAT teleprotection terminal working with a guardfrequency of 3800 Hz. The data interfacecomplies with specifications V.24 and V.28 of the ITU-T and RS-232C of EIA.

     The MQBT is a modem with a programmablemodulation scheme, capable of operating withfrequency-shift keying (FSK) modulationaccording to Recommendations V.23 and V.21of ITU-T, as well as with multi-level modulations(DPSK, QAM and TCM) according toRecommendations V.34, V.32bis, V.32, V.22bisand V.22 of ITU-T. It can transmit synchronousor asynchronous data at a speed of up to28800 bit/s in line. It has two types of interface:

     V.24/V.28 of the ITU-T (with one clock foremission and another for reception) and V.11in accordance with standard ISO4903 (a singleclock).

    External

    MAS-2 and MDD-2

     The MAS-2 modem consists of a shelf that isone standard unit (s.u.) in height and 19" inwidth, incorporating a single-printed modemboard type MAFP. The said modem board canbe inserted in MDD-2 shelves, allowing up to14 boards to be installed.

    Built-in

    Modems por PLC systems

    MAS-2

  • 8/19/2019 Gama Dimat Catalog Be17

    10/16

    10

    NRTR equipment is a real time router that usesproprietary technology allowing to manage anynetwork topology and is not restricted to theuse of specific topologies such as rings, starsor trees, and therefore the configuration of thenetwork can be most suitable for therequirements of companies.

    NRTR equipment also supports a proprietaryoperating mode (TRAME).

     The routing procedure used by the NRTRadapts automatically to changing topologicalconditions. In the case of a link failure, thenetwork can automatically re-route the data.

     The NRTR has different interfaces that allowslinks of different types and speeds, both analogand digital, to be integrated into a singlenetwork.

    In both operating modes, the NRTR is capableto accept clients for many standard and legacytelecontrol protocols, such as: IEC 870-5-101,IEC 870-5-104, DNP 3.0, Vancomm, Mobdus,and Optomux. A built-in 104-101 Gatewayenables the NMS (Network ManagementSystem) to manage a RTU based on 101protocol as it was a RTU running 104 protocol.

    NRTR

    Real time router especially suited for telecontroltransport services

    In order to fulfil security and reliabilityrequirements, our proprietary link protocols, inaddition to those already present in standardrouters, are specially developed to be deployedover owned or hired transport resources,including analog communication channels, andacross existing network structures usingPDH/SDH or LAN.

     The NRTR equipment has the standard routingprotocols (OSPF, RIP), as well as a proprietaryrouting protocol to support highly meshednetworks, multipath and load balance.

    In propietary operating mode, data managementis carried out in accordance with the priority

    assigned to them by the user. The differentequipment organise queues of packetsaccording to priority, which ensures that packetsof greater priority suffer less delay.

    NRTR

  • 8/19/2019 Gama Dimat Catalog Be17

    11/16

    11

    DIMAT

    NRTR interfaces

    Key features

    · Ability to build any network topology· Automatic adaptability to topological andtraffic changes

    · High immunity against electromagnetic distur-bances

    · Proprietary integrated network supervision / SNMP V1, V2c and V3 agent

    · High degree of data integrity· Built-in Gateway 104-101 service· Standard routing protocols (OSPF, RIP) anda proprietary routing protocol (to supporthighly meshed networks, multipath and loadbalance)

    · Proprietary link protocols, in addition to those

    already present in standard routers, to bedeployed over owned or hired transport re-sources

    · Up to 8 priority levels (TRAME proprietaryoperating mode)

    · Supports hot-swap

    · Available interfaces:- Local area network interfaces type Ethernetat 10/100 Mbit/s, with electrical or opticalinterface

    - Low-speed line serial interfaces (V.24/V.28, V.24/V.11, V.35, EIA-530-A, V.36 and X.21)- Medium and high-speed line serial interfaces(G.703 at 64 kbit/s, G.703 at 2 Mbit/s)

    With capabilities to

    build meshed

    networks over a wide

    range of interfaces

    and media

    Rear view

  • 8/19/2019 Gama Dimat Catalog Be17

    12/16

     All variables of the TPU-1 terminal that can bemonitored are to be found in the MIB of the

    terminal, which can be integrated into themanagement platform.

     TPU-1 terminals comply with ANSI C37.90.1and ANSI C37.90.2 standards.

    Key features

    · Modular design· Extremely high security and dependability· Compatible with IEC 61850 standard· Complies with ANSI C37.90.1 and ANSIC37.90.2 standards

    · Complies with IEC 60834-1 standard· SNMP agent· Operates in analog and/or digital channels· Up to four commands in analog channels;

    Power-Line Carrier links, telephone cables,radio links, etc.

    · Up to eight commands in digital channels;E1/T1 interfaces (G.703), 64 kbit/s (G.703,

     V.11 or V.35 or X.21) and 64 kbit/s with opticalinterface

    · Input and output logic programmable by theuser (up to sixteen analog inputs and outputsand up to sixteen inputs and outputs inaccordance with IEC 61850 standard)

    · Can be used for blocking, direct and permissivetripping schemes as well as for telesignallingsystems

    · Two independent teleprotection terminals orone terminal with a main and a back-upchannel

    · Command transits in a ring and in T   (Teed-line)· IRIG-B port for GPS time synchronization· Synchronization via Ethernet using the NTPprotocol

    · Chronological register (1400 alarms and events)with 1 ms resolution

    · Web management system with LANconnection

    · Internal channel for end-to-end supervision· Signalling and alarm relays programmable bythe user

    · Additional optional features like LCD screenfor command-counters, power-supplyredundancy, shielded cables for cabinet-mounting terminal blocks, etc.

    12

    TPU-1

    Highly flexible and configurable forapplication diversity 

     The modular design of TPU-1 terminals allowsthe use of different types of modules accordingto teleprotection needs of each application.

     This modularity allows TPU-1 terminals tomanage one or two digital and/or analogchannels. In cases where the TPU-1 terminalmanages two channels, it can be configuredto operate as two independent teleprotectionterminals (in a single shelf) or one teleprotectionwith main and back-up channels.

     TPU-1 terminals operating in analog channelscan transmit and receive up to fourteleprotection commands. TPU-1 terminalsconfigured to operate in digital channels (withelectrical or optical interface) enable two-way

    transmission of up to eight teleprotectioncommands. An input logic that allows thecommand transmission process to begin canbe established using an AND or ORcombination of up to sixteen inputs, and onthe other, establish the output logic for eachcommand received.

     TPU-1 terminals are IEC 61850 compatibles,so communication between a TPU-1 and aprotection device inside a substation can becarried out according to this standard (GOOSEmessages). However, if a protection device isnot compatible with IEC 61850 standard, TPU-1 terminals can also communicate with it usinganalog protection interfaces (optoisolated inputs

    and solid-state relays).

    One outstanding feature of the TPU-1 terminais that it can transit the received informationtowards another terminal being possible, forexample, connect various TPU-1 terminals ina ring configuration or in T (Teed-line).

     The TPU-1 terminals, furthermore, include anSNMP agent able to send notifications(unsolicited information spontaneouslytransmitted) about alarms and events of theterminal to the devices specified by the user,and this makes it possible to monitor the TPU-1 terminal from an SNMP managementapplication, such as, HP Openview.

    TPU-1

    UniversalTeleprotection Terminal

  • 8/19/2019 Gama Dimat Catalog Be17

    13/16

    13

    DIMAT

    High reliability and flexibility 

     TPD-2 permits two-way transmission of up to8 independent and simultaneous teleprotectioncommands, through electrical (G.703, V.11 and

     V.35) and opt ica l digit al channe ls. Eachcommand can be programmed independentlyfor direct trip, permissive trip or blockingapplications, as well as for telesignalling.

     TPD-2 terminals can manage two simultaneousline interfaces to enhance dependability: a mainline and an alternative backup line, in case afault occurs on the main line.

    Key Features

    · Modular design· Extremely high security and dependability

    · Transmission of up to 8 independent andsimultaneous commands

    · 32 kbit/s, 64 kbit/s or 2 Mbit/s transmissionspeed with electrical interfaces and 64 kbit/swith optical interface

    · Possibility of managing a back-up line interface· Two 0 to 999 counters per command, onefor transmission and one for reception

    · Two inputs per command, optoisolated, withdecision logic programmable by the user

    · One solid-state output relay per command,with voltage-free contact and current limitation

    · One command-transmission signaling andone command-reception signaling per com-mand

    · 4 programmable alarm relays· Internal channel for end-to-end supervision

    · Local management system based on a Webinterface and optional Web managementsystem with LAN connection

    DigitalTeleprotection Terminal

    TPD-2

    TPD-2

    The DIMAT

    teleprotectionterminals provide

    an optimal

    combination of

    security,

    dependability and

    transmission time

    Outstanding features, security, andreliability 

    DIMAT's highly secure analog teleprotectionterminal is designed to be used with any analogtransmission channel such as Power-LineCarrier links over high-voltage lines, telephonecables, radio links...It is designed and developed according to theIEC 60834-1 Recommendat ion forteleprotection systems.

     TPC-2 terminals can be equipped to transmitand receive two or four commands. Thesecommands can be used for blocking,permissive and direct tripping teleprotectionschemes, achieving in each case an optimalcombination of security, dependability andtransmission time.

    Key Features

    · High dependability and extremely high security· Meets Recommendation IEC 60834-1regarding teleprotection systems

    · lntended for blocking, direct tripping andpermissive tripping schemes as well as fortelesignalling

    · Compatible with the transmission of speechand data across the same channel

    · 2-command and 4-command versions· Three programmable nominal transmissiontimes

    · Two 0 to 99 counters per command, one fortransmission and one for reception

    · One input per command, optoisolated· One solid-state output relay per command,with voltage-free contact and current limitation

    · One command-transmission signaling andone command-reception signaling percommand

    · Optional IRIG-B port for GPS timesynchronization

    · Internal channel for end-to-end supervision· Local management system based on a Webinterface and optional Web managementsystem with LAN connection

     AnalogTeleprotection Terminal

    TPC-2

    TPC-2

  • 8/19/2019 Gama Dimat Catalog Be17

    14/16

    There is a specific Product data sheet for all

    of DIMAT’s products.For further information, please ask for the Product data sheet you areinterested in.

    24h. Assistance in Europe and Africa

     S e r v i c i o 

     d e

     A s i s t e n c

     i a

     P e r m a n e n

     t e

     + 3 4  6 7 7 

     5 5 1  5 8 9

     2 4 h  d u r a

     n t e

     3 6 5  d í a s

      a l  a ñ o

    24h. Assistance in USA and Canada

     T e c h n i c a

     l

     A s s i s t a n

     c e

     A r o u n d  t

     h e  C l o c k

     ( 8 7 7 )  Z I V

     - U S A  1

     2 4  h o u r s

     3 6 5  d a y s

    24h. Assistance in Brazil and South America

     A s s i s t ê n

     c i a

     T é c n i c a P e r m

     a n e n t e

     ( 2 1 )  3 6 0 2

      8 5 1 1

     2 4 h  d u r a

     n t e

     3 6 5  d i a s

      a o  a n o

    14

  • 8/19/2019 Gama Dimat Catalog Be17

    15/16

    15

    DIMAT has a test laboratory  for carrying out type tests on our terminalsin order to verify that they meet with international standards and the

    customer particular requirements.

    Since DIMAT first began, it has been one of the most significant

    references as far as procedures for measurement and characterization

    of the teleprotection system parameters are concerned to the extent

    of the methods adopted by DIMAT were used in the ASINEL

    “Teletransmisiones” Working Group and were also included in the“Testing guide for teleprotection terminals”.

     At DIMAT, we take quality as seriously as our

    users.

    Our quality management program aims to bring

    you industry-leading quality in our products and

    services.

    DIMAT is ISO 9001:2000 certified. Quality is

    built into our products every step of the way.

    DIMAT is certified for the following field of activities: The design and production of telecomunicationequipment for information transmission over the powerlines. Switching equipment for control networks.

    DIMAT, Quality 

    management you

    can count

    Each product of DIMAT is subjected to rigorous quality 

    controls to guarantee customer satisfaction.

  • 8/19/2019 Gama Dimat Catalog Be17

    16/16

           E        S       P    -       1        0        0        0    -        0        6    -        0       7

       0   8   5   0   0   0   0   1   6   E   3

       ©

       D   I   M   A   T   S .   A .   2   0   0   9

    http://www.ziv.es

    For our references, please consult DIMAT website.

    DIMAT continually strives to improve the quality andperformance of i ts products and services.Consequently, technical information contained in thisdocument is subject to change without prior notice.

    Biscaia, 38308027 Barcelona, SpainTel.: +34 93 349 07 00Fax: +34 93 349 22 [email protected]://www.dimat.com

    Other locations of ZIV Group:

    SpainHeadquarters (ZIV Group):Parque Tecnológico, 21048170 Zamudio, VizcayaTel.: +34 94 452 20 03Fax: +34 94 452 21 40http: //www.ziv.es

    Madrid:C/ Diego Marín Aguilera 14Pol. Leganés Tecnológico, 28918Leganés, MadridTel.: +34 91 352 70 56Fax: +34 91 352 63 04

    Sevilla: Avda. de la Aeronáutica, 10(Edificio Helios) Planta 7ª, módulo 4,

    41020 SevillaTel.: +34 954 461 360Fax: +34 954 462 484

    Las Palmas:Fernando Guanarteme 16. Ofic. 1º A 35007 Las Palmas de Gran CanariaTel.: +34 94 452 20 03

    U.S.A. and Canada:2340 River Road60018 Des Plaines, Chicago, IllinoisTel.: +1 847 299 65 80Fax: +1 847 299 65 81

    Brazil:

     Av. Padre Natuzzi, 200CEP 24.360-180, São Francisco,Niteroi, Rio de JaneiroTel.: +55 21 36 02 8511Fax: +55 21 36 02 8511 opção 5

    United Arab Emirates:Mazaya CenterBlock C - Suite 3005P.O. Box: 3089 - Dubai - U.A.E.

    Singapore:10 Anson Road No. 25-07International PlazaSingapore 079903Tel.: +65 6410 9625Fax: +65 6410 9631

    Russia:Ul. Bolshaya Dmitrovka,7/5, str. 2, 4th floor125009 MoscowTel.: +7 495 580 92 93