Sec�on 1 - Iden�fica�on Product Iden�fier: Fuel Injector Cleaner
Intended Use Industrial Solvent Cleaner
Uses To Avoid Applica�ons subject to forma�on of mist in air within explosive ranges - see Sec�on 9.
MAXX Solutions
4243 Gatecrest, Suite 103,San Antonio TX 78217
Supplier Phone: 210-368-9248
Emergency Phone & Hours: 210-688-4966 24 hrs, 7 days/week
Sec�on 2 - Hazard Iden�fica�on Signal Word: DANGER Other than flammability, no specific data exists forthis mixture. Hazard classifica�ons are calculatedbased on component informa�on, according to GHSprotocols for the relevant hazard.
Flammable Liquid (Category 2), Eye damage/irrita�on (Category 2A), Carcinogenicity (Category 2), Skin Corrosion/Irrita�on(Category 2),
Hazard Statements based on component informa�on:HAZARDS: Highly flammable liquid and vapor. Eye contact causes serious eye irrita�on. Suspected of causing cancer.Skin contact causes skin irrita�on.
Precau�ons:Do not handle un�l all safety instruc�ons are understood. Avoid breathing fumes or mist. Avoid skin contact. Wear protec�veclothing, gloves, and eye protec�on before handling. Use only with adequate ven�la�on.
Other Hazards Not Resul�ng In Classifica�on:May be hazardous to soil dwelling organisms.
Summary: Read en�re SDS prior to use. Observe all precau�ons. Use engineering controls to minimize human exposure toworkplace chemicals.
Substance Or Mixture MixtureHazard Classifica�ons:
Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6
PICTOGRAMS:
4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248
Sec�on 4 - First Aid Measures:
IF SWALLOWED: Do not induce vomi�ng. Rinse mouth. Get immediate medical a�en�on.
IF INHALED: Remove affected person to fresh air and make comfortable for breathing. Get immediate medical a�en�on.
IF IN EYES: Remove contact lenses and rinse eyes with cool water. Get immediate medical a�en�on.
IF ON SKIN: Remove all contaminated clothing. Wash exposed skin/hair with soap and water.
IF ON CLOTHES: Do not allow skin contact with contaminated clothing. Remove contaminated clothing and wash before re-use.
IF EXPOSED: Contact physician if you feel unwell.
First responders should wear clothing appropriate for industrial exposure in accordance with local codes. At a minimum, all exposedskin should be covered, and latex gloves and eye protec�on mee�ng ANSI Z87 or CSA Z94.3 should be worn. First responders shouldavoid contact with spilled material. Spills of this material present a slip hazard. If smoke, fumes, or airborne mist is present, firstresponders should use organics respirator or self contained breathing apparatus.
Most Important Symptoms ACUTE: Respiratory effects, vision effects. DELAYED: Dermatological effects.
Indica�on of ImmediateMedical A�en�on
Difficulty breathing, dizziness, extreme drowsiness, eye irrita�on, loss of vision, skin rash.
Fuel Injector CleanerPage 2
Sec�on 3 - Composi�on / Informa�on on Ingredients
ALIPHATIC NAPTHA
MIXED XYLENES
4-METHYL-2-PENTANONE
AROMATIC HYDROCARBON POLYMER MIXTURE
64475-85-0
MIXTURE
108-10-1
MIXTURE
60 - 100
15 - 40
5 - 15
1 - 5
Exact percentages and componentiden��es are being witheld as tradesecrets. Occupa�onal Exposure Levels,Toxicity, and Ecological informa�on oncomponents is shown in Sec�ons 8, 11,and 12 below. Users should read andunderstand the en�re SDS. More specificinforma�on on components will bereleased to medical professionals in caseof emergency.
Component CAS Number % Range
Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6
4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248
Sec�on 5 - Fire Figh�ng Measures:
AppropriateEx�nguishing Media
Avoid spraying water jet on burning hydrocarbon liquids as this may spread the fire. Use dry chemicalor foam ex�nguishing media.
Specific Fire Hazards Fire fighters must be protected from smoke with self contained breathing apparatus. Heavy smoke mayobscure vision. Smoke may contain oxides of carbon, nitrogen, sulfur, and chlorine.
Special Protec�ve Ac�ons Use water spray to cool exposed containers.
Sec�on 6- Accidental Release Measures:Personal Precau�onsSpills present a slip hazard. Ex�nguish/disconnect possible sources of igni�on near spill. Ensure adequate ven�la�on of fumes fromaffected area. Remove unneccesary personnel from area around spill. Prior to cleaning up, don protec�ve gear including chemicaland hydrocarbon resistant outer layer, latex or rubber gloves, rubber boots, and eye protec�on. Emergency responders should wearchemical and hydrocarbon resistant gear.
Environmental Precau�onsSmall spills may be wiped up with rags. For spills >10 litres- if possible to safely do so, contain the spilled material usingdiatomaceous earth and/or absorbent pads. Dike drains and prevent material from entering sewers, ditches, drains, or watercourses. Place absorbed material into sealed storage containers and consult an environmental expert for proper disposal measures.Immediately report any discharges that escape containment to the local environmental authority or fire department.
Methods for Cleaning UpAbsorp�on with diatomaceous earth and/or absorbent pads is best. Do not use vacuum. Do not wash hydrocarbon or chemical spillsaway into sewers or drains. Use proper disposal methods for spent absorbents and contaminated rags or clothing.
Sec�on 7- Storage and Handling:Precau�ons for HandlingRead and understand en�re Safety Data Sheet prior to handling. Wear all appropriate protec�ve gear prior to handling. Do not allowuntrained personnel to handle this product. Handle with care to avoid spillage.
Methods for Safe StorageStore only in original containers. Store containers indoors away from heat and flames. Store in secure loca�on with goodven�la�on. Keep container sealed when not transferring product. Protect from rain and extreme cold. Avoid storage ofhydrocarbons near strong mineral acids or materials marked 'Oxidizer'.
Fuel Injector Cleaner
Page 3Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6
Flash Point <23C
HazardousDecomposi�on Products
Byproducts of combus�on include carbon dioxide, carbon monoxide, oxides of sulfur, oxides ofnitrogen, and heavy, acrid smoke.
4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248
Page 4
Sec�on 9- Physical Proper�es:
Appearance Clear to Hazy Liquid Upper Explosive Limit 5.4Odor Low Indescript Lower Explosive Limit 0.7
Odor Threshold No Data Available Vapour Pressure 0.8mm Hg 20CpH N/A oil based Vapour Density >1 (air=1)
Mel�ng Point Liquid under intended use condi�ons Rela�ve Density 0.75 kg/l 60CFreezing Point 0 to -20 Solubility Hydrocarbons, Alcohols
Ini�al Boiling Point No Data Available Par��on Coefficient Log KOW > 4 (mineral oil data)Boiling Range 313C - 432C Auto Igni�on Temp Not Determined
Flash Point <23C Decomposi�on Temp Not DeterminedEvapora�on Rate <1 (n-butyl acetate =1) Viscosity cSt 40C <14.5 cSt 40C
Personal Protec�ve GearEye/Face Protec�on: ANSI Z87.1-1989 ; Gloves: Latex or Neoprene; Workers should wear safety glasses, gloves, long sleeves, longpants, hair covering, and oil resistant shoes, when handling this product.
Engineering ControlsEngineering controls should ensure adequate ven�la�on to keep airborne concentra�ons below threshold values shown above.Pumps and handling equipment should be designed to reduce human exposure poten�als to liquids being transferred fromcontainers into closed systems.
Sec�on 8- Exposure Controls/Personal Protec�on:Control ParametersNo exposure limits are established for this mixture. Users should use lowest exposure value shown for components in this sec�on.
TWA 25ppm
Xylene ANESL 42 ppb; Ethylbenzene AN ESL 570 mg/m3; Toluene TWA 20 ppm
TWA: 50 STEL: 75 CEIL: 125 (ppm) from ACGIH (TLV) [1995] TWA: 205 STEL: 300 CEIL: 510 (mg/m3) from ACGIH[1995]PEL OSHA TWA 8 HRS 100 PPM
Component Informa�on - Occupa�onal Exposure Limits:ALIPHATIC NAPTHA
MIXED XYLENES
4-METHYL-2-PENTANONE
AROMATIC HYDROCARBON POLYMERMIXTURE
Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6Fuel Injector Cleaner
4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248
Sec�on 10- Physical Proper�es:
Possibly Hazardous Reac�ons None known.
Reac�vity May react violently if combined with strong oxidizers and heat.
Chemical Stability Stable under recommended storage condi�ons.
Condi�ons to Avoid Keep away from fire, sparks, and other sources of igni�on.
Incompa�ble Materials Strong acids and materials marked 'Oxidizer'.
Hazardous Decomposi�onProducts
Byproducts of combus�on include carbon dioxide, carbon monoxide, oxides of sulfur, oxides ofnitrogen, and heavy, acrid smoke.
Sec�on 11- Toxicological Informa�on:
Likely Routes ofExposure
Dermal exposure from handling. Intended use may include hand wiping or handling parts having product residues onthem. Inhala�on exposure to fumes is possible if used without adequate ven�la�on.
Symptoms of Exposure:
Inges�on Inges�on of minimal amounts, e.g. failure to wash hands before ea�ng/smoking, is unlikely to cause symptoms.Swallowing of liquid product may cause vomi�ng and nausea.
Inhala�on No symptoms are expected under intended use condi�ons. Exposure to concentrated fumes may cause transienthypoxia.
Dermal/Eye Dermal exposure results in defa�ng and localized irrita�on. Eye exposure causes transient s�nging and blurred vision.
Immediate orDelayed Effects
Immediate: Hypoxia symptoms from inhala�on of concentrated solvent vapors. Delayed: None Known.
Interac�ve Effects None Known
Numerical Measures of Toxicity - components (all LD/LC/EC 50 values shown below are based on animal or fish data) at max range value sec�on 3.
Page 5
ALIPHATIC NAPTHA: Non Hazardous; MIXED XYLENES: LD50 4,300 mg/Kg; 4-METHYL-2-PENTANONE: LD50 1600 mg/Kg;AROMATIC HYDROCARBON POLYMER MIXTURE: Non Hazardous
Acute OralToxicity:
Acute SkinToxicity:
ALIPHATIC NAPTHA: Non Hazardous; MIXED XYLENES: LD50 14,100 mg/Kg; 4-METHYL-2-PENTANONE: LD50 LD50: 20001 mg/kgmg/Kg; AROMATIC HYDROCARBON POLYMER MIXTURE: Non Hazardous
Acute ToxicityInhala�on
ALIPHATIC NAPTHA: Non Hazardous; MIXED XYLENES: LD50 4,550 mg/Kg; 4-METHYL-2-PENTANONE: LD50 LC50: 8000 ppm 4hours (Rat) mg/Kg; AROMATIC HYDROCARBON POLYMER MIXTURE: Non Hazardous
Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6
Fuel Injector Cleaner
4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248
Skin Corrosion: ALIPHATIC NAPTHA: Non Irrita�ng; MIXED XYLENES: Cat 2 Irritant; 4-METHYL-2-PENTANONE: Non Irrita�ng; AROMATICHYDROCARBON POLYMER MIXTURE: Cat 2 Irritant
Eye Corrosion: ALIPHATIC NAPTHA: Cat 2A Serious Irrita�on; MIXED XYLENES: Cat 2A Serious Irrita�on; 4-METHYL-2-PENTANONE: Cat 2ASerious Irrita�on; AROMATIC HYDROCARBON POLYMER MIXTURE: Cat 2A Serious Irrita�on
RespiratorySensi�za�on:
ALIPHATIC NAPTHA: Non Sensi�zing; MIXED XYLENES: Non Sensi�zing; 4-METHYL-2-PENTANONE: No Data Available;AROMATIC HYDROCARBON POLYMER MIXTURE: Non Sensi�zing
SkinSensi�za�on:
ALIPHATIC NAPTHA: Non Sensi�zing; MIXED XYLENES: Non Sensi�zing; 4-METHYL-2-PENTANONE: No Data Available;AROMATIC HYDROCARBON POLYMER MIXTURE: Non Sensi�zing
Germ CellMutagenicity:
ALIPHATIC NAPTHA: No Data Available; MIXED XYLENES: No Hazard; 4-METHYL-2-PENTANONE: No Data Available; AROMATICHYDROCARBON POLYMER MIXTURE: No Hazard
Carcinogen: ALIPHATIC NAPTHA: No Hazard; MIXED XYLENES: Cat 1B Presumed Human Effects; 4-METHYL-2-PENTANONE: No DataAvailable; AROMATIC HYDROCARBON POLYMER MIXTURE: Cat 1B Presumed Human Effects
Reproduc�veEffects:
ALIPHATIC NAPTHA: No Hazard; MIXED XYLENES: Cat 1B Reproduc�ve Toxicant; 4-METHYL-2-PENTANONE: No Data Available;AROMATIC HYDROCARBON POLYMER MIXTURE: No Hazard
Page 6
Sec�on 11- Toxicological Informa�on: (con�nued)
Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6
Fuel Injector Cleaner
4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248
Other Informa�on Avoid applica�on by mist and concentra�on of solvent mists in air, which are poten�ally explosive.
Page 7
Target Organ 1Exposure:
ALIPHATIC NAPTHA: No Hazard; MIXED XYLENES: No Hazard; 4-METHYL-2-PENTANONE: Cat 3 Transient Toxicant - CNS, Liver,Kidneys; AROMATIC HYDROCARBON POLYMER MIXTURE: No Hazard
Target OrganMul�pleExposure:
ALIPHATIC NAPTHA: No Hazard; MIXED XYLENES: No Hazard; 4-METHYL-2-PENTANONE: No Hazard; AROMATIC HYDROCARBONPOLYMER MIXTURE: Cat 2 Toxicant- CNS, Liver, Kidneys (animal data)
Aspira�onHazard:
ALIPHATIC NAPTHA: No Hazard; MIXED XYLENES: No Hazard; 4-METHYL-2-PENTANONE: No Hazard; AROMATIC HYDROCARBONPOLYMER MIXTURE: Cat 1 Aspira�on Hazard
Sec�on 11- Toxicological Informa�on: (con�nued)
Sec�on 12- Ecological Informa�on:
Ecological Summary Mineral oil/solvent blends and solvents have varying degrees of toxicity and degradability. Specific informa�on oncomponents is shown below.
Bioaccumula�on Mineral oil/solvent blends and solvents have low bioaccumula�on poten�al. Specific informa�on on components isshown below.
Persistance &Degradability
Mineral oil/solvent blends and solvents are inherently biodegradable. OECD Values range from 25% to 60% in 28 days.
Waste TreatmentEffects
Product residues are not expected to enter publicly operated treatment works. No nega�ve effects of this mixture areknown.
Soil Mobility Mineral oil/solvent blends and solvents will par��on rapidly to air, are expected to have low soil mobility poten�al.
Other AdverseEffects
None Known
Toxicity to aqua�c organisms, component informa�on:
Aqua�cToxicity,Acute:
ALIPHATIC NAPTHA: No Data Available; MIXED XYLENES: Non Toxic; 4-METHYL-2-PENTANONE: Non Toxic; AROMATICHYDROCARBON POLYMER MIXTURE: L(E)C5011-100mg/l
Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6
Fuel Injector Cleaner
4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248
Sec�on 13- Disposal Considera�ons:Disposal Containers & Methods Unused material is not a RCRA hazardous waste. Mixture with other wastes may cause
classifica�on as hazardous waste. Users must determine compliance with local, state, and federalregula�ons for proper classifica�on and disposal of used oils and mixtures thereof. Suitablecontainers include steel and polyethylene drums and totes, for containment of used oil. Secondarycontainment is advised. Containers should be kept sealed and protected from rain and exposure.
Physical Chemical Proper�esAffec�ng Disposal
Changes in physical and chemical proper�es during use, such as contamina�on with lead, zinc, orother metals, may affect classifica�on for disposal. Used oils should be tested to determine metalscontent and applicable local, state, and federal regula�ons governing disposal of such fluids.
Improper Disposal Discharging of oily wastes into any sewer , watercourse, or unregulated drain is discouraged asimproper and may result in fines, penal�es, cleanup costs, and criminal liabili�tes for responsiblepar�es.
Precau�ons for Landfill Oily liquid should not be disposed in a landfill. Disposal of oily absorbents, rags, or other items intoa landfill should only be done with proper permission from local, state, and federal authori�es.
ALIPHATIC NAPTHA: No Data Available; MIXED XYLENES: No Chronic Aqua�c Toxicity; 4-METHYL-2-PENTANONE: No Chronic Aqua�cToxicity; AROMATIC HYDROCARBON POLYMER MIXTURE: Cat 3 Chronic Aqua�c Effects
Aqua�cToxicity,LongTerm:
Ozone: This product neither contains, nor was manufactured with a Class lor Class ll ODS as defined by 40 CFR 82, Subpt. A, App.A + 8.
Sec�on 14- Transport Informa�on:
Proper Shipping Name Flammable liquid UN1993, (petroleum naptha) UN/ID/NA Number: 1993
Transport Hazard Class 3 Packing Group III
Special Precau�ons None
US DOT 49 CFR Parts 171-180:
Labels: 3 ERGCode 128
Marine Pollutant: No
IATA-DGR
UN/ID Number 1993IATA Proper Shipping Name Flammable liquid UN1993, (petroleum naptha)
IATA Class 3 IATA Labels 3IATA Packing Group: III
IMDG-CODE
IMDG Proper Shipping Name Flammable liquid UN1993, (petroleum naptha)
IMDG UN/ID Number 1993 IMDG Shipping Class 3 IMDG Packing Group III
IMDG Labels 3 IMDG Marine Pollutant: No
MARPOL 73/78 Annex II
MARPOL Not available for sale in bulk marine shipments
Page 8Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6Fuel Injector Cleaner
4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248
Page 9
All Components are properly registered
CA Prop 65 WARNING: This product contains a chemical known to the State of California to cause cancer. This product contains achemical known to the State of California to cause birth defects or other reproduc�ve harm. Cumene, Ethylbenzene,Napthalene
Other Regula�ons
TSCA Status:
REACH : All components are included in the REACH registry.
Canada WHMISHazard Class:
B-1, D-2A B-2
Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6
Sec�on 15- Regulatory Informa�on:
SARA 313 EHS No Known Hazard or Not Listed
OSHA 1910.1200 Hazardous Chemical: Hazards are classified as reported in Sec�on 2 above.
No Known Hazard or Not ListedSARA 302 EHS
Fuel Injector Cleaner
Reac�vity No Acute No Chronic No Fire Yes Pressure NoSARA 311/312
US State Lists & Regula�ons:
No Known Hazard or Not ListedIL RTK:
Stoddard solvent; Naphtha; hydrodesulfurized heavy; Ethylmethylbenzene; xylene Ethylbenzene, CAS 100-41-1; Xylene, CAS1330-20-7;
MA RTK:
No Known Hazard or Not ListedMN RTK:
Ethylbenzene, CAS 100-41-1; Xylene, CAS 1330-20-7;NJ RTK:
Ethylbenzene, CAS 100-41-1; Xylene, CAS 1330-20-7;NY RTK:
Ethylbenzene, CAS 100-41-1; Xylene, CAS 1330-20-7;PA RTK:
No Known Hazard or Not ListedRI RTK:
No Known Hazard or Not ListedSafe Drinking WaterAct:
US State Right To Know Informa�on:
Interna�onal Chemical Inventory Status:
Australia AICS Canada DSL
Canada NDSLChina IECSC Europe EINECS
Japan ENCS Korea ECL
Europe ELINCS New Zealand InvPhillipines PICCS
NOTE: Informa�on provided in this sec�on reflects the best available informa�on from suppliers ofcomponents used to manufacture this mixture, as of the date of this revision shown below.
4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248
Sec�on 16- Other Informa�on:
Revision Date 6/13/2019
Reasons For Revision New Informa�on From Supplier GHS
Sec 16 Other Info This Safety Data Sheet was prepared in good faith from the most recent informa�on available, inaccordance with ST/SG/AC.10/30/Rev.6. HOWEVER, NO WARRANTY OF MERCHANTABILITY, FITNESSFOR ANY PARTICULAR PURPOSE, OR ANY OTHER WARRANTY IS EXPRESSED OR IS TO BE IMPLIEDREGARDING THE ACCURACY OR COMPLETENESS OF THE INFORMATION PROVIDED ABOVE, THE RESULTSTO BE OBTAINED FROM THE USE OF THIS INFORMATION OR THE PRODUCT, THE SAFETY OF THISPRODUCT, OR THE HAZARDS RELATED TO ITS USE. No responsibility is assumed for any damage or injuryresul�ng from abnormal use or from any failure to adhere to recommended prac�ces. The informa�onprovided above, and the product, are furnished on the condi�on that the person receiving them shallmake their own determina�on as to the suitability of the product for their par�cular purpose and on thecondi�on that they assume the risk of their use.
Page 10
Fuel Injector Cleaner
Safety Data Sheet - according to: 1907/2006 EC (REACH), 1272/2008/EC (CLP), GHS ST/SG/AC.10/30/Rev6
4243 Gatecrest, Suite 103, San Antonio TX 78217(210) 368-9248