www.ilsintech.com This product or document is protected by copyright and distributed under licenses restricting its use, copying and distribution. No part of this product or document may be reproduced in any form by any means without prior written authorization of ILSINTECH Co., Ltd. Products shown on this catalog are subject to change at any time without any prior notice for improvement purpose. Copyright 2016 ILSINTECH Co., Ltd. All rights reserved. FTTH Fusion SOC / MPO SOC / Patch Cord Discover the difference, Unlike any other!

Upload: phungdang

Post on 06-Mar-2018

226 views

Category:

Documents


5 download

TRANSCRIPT

www.ilsintech.com

This product or document is protected by copyright and distributed under licenses restricting its use, copying and distribution.No part of this product or document may be reproduced in any form by any means without prior written authorization of ILSINTECH Co., Ltd.Products shown on this catalog are subject to change at any time without any prior notice for improvement purpose.

Copyright ⓒ 2016 ILSINTECH Co., Ltd. All rights reserved.

FTTH Fusion SOC / MPO SOC / Patch Cord

Discover the difference, Unlike any other!

Perfect Solution withALLINONE splicer + FTTH Fusion SOC

Compliant with Telcordia GR-326-CORE

Maintenance-free

Over 15 years

Budget-priced

TENSILE STRENGTH

MAINTENANCE

LIFE-SPAN

INSTALLATION COST

Vs Mechanical Connector Vs Pre-terminated Cord (Pigtail)

- Low insertion loss (less than 0.2dB)

- High tensile strength

- No skilled labor required

- No extra tools needed

- Operation time : within 2 minutes

- 25% lower than Mechanical Connector

- Installation Cost (FTTH SOC + Swift Splicer < Mechanical Connector)

- Permanent life span (More than 15 years)

- No maintenance required

COST

MAINTENANCE

TASK DIFFICULTY

Comparison FTTH Fusion SOC with the others

QUALITY

- Optimized loss rate (Pigtail has bending loss issue)

- Double-protected splicing point

- Easy work and best performance with Swift fusion splicers

- No extra tools needed

- Operation time: within 2 minutes

- Similar cost but no extra cost (Pigtail needs extra sleeve, cassette)

- Installation cost (FTTH SOC < Pre-terminated cord)

- Pigtail needs extra protection at splicing point, this means pigtail is vulnerable to external environment.

QUALITY

COST

MAINTENANCE

TASK DIFFICULTY

ILSINTECH

Key Features- In accordance with IEC 61754-4,IEC 61754-20,IEC 61754-13,IEC 61754-2

- Compliant with Telcordia GR-326-CORE

- Directly splicing with drop cable and Indoor cable

- Spliced point is protected in the Connector, no extra splice fixtures required

- Enhanced high quality with improved optical features

- Enhanced and improved high tensile strength

Applications- FTTH, CATV, FTTx

- Data center installation

- Central office cable management

SpecificationITEM

Insertion Loss

Operating Temperature

Fiber

Return Loss

Mating Durability

Cable

UPC APC

-40℃ ~ 75℃

SM 9/125um

>50dB >60dB

500 Cycle, ≤ 0.2dB change

0.9mm, 2.0, 2.4, 3.0mm Cord, Drop Cable(2mm x 3mm)

PC

MM (OM1, OM2, OM3, OM4)

-

Single Mode Multi Mode

≤ Avg. 0.2dB(≤ Max. 0.3dB)

Connector Types SC, LC, FC, ST

Ilsintech's high quality, low cost Fusion Splice-on Connector (SOC) has become a most

reliable solution to terminate the fiber out in the field for FTTH outside plant.

The FTTH Fusion SOC has a factory pre-polished ferrule and it requires no epoxy and

no field polishing. And the FTTH Fusion SOC utilizes Swift series of the fusion splicers,

such as F1, F1 Plus, KF4A, KF4A Plus and S5 to terminate the connector, and it is compliant with

Telcordia GR-326-CORE. SC, LC, FC and ST connectors are available for APC and/or UPC applications.

Field installable Fusion Splice-on Connector

Structural Feature

Splicing

Heat Shrinkable Sleeve

Drop Cable

50

00.00 0.10 0.20 0.30 0.40

100

150

200

1310mmN=504Averge=0.08(dB)S.D=0.07(dB)

250

1550mmN=504Averge=0.12(dB)S.D=0.07(dB)

Freq

uenc

y(N

)

Insertion Loss(dB)

50

053.0 54.0 55.0 56.0 57.0

100

150

200

1310mmN=504Averge=54.92(dB)S.D=0.56(dB)

250

1550mmN=504Averge=55.1(dB)S.D=0.47(dB)

Freq

uenc

y(N

)

Return Loss(dB)

Key Features- Low Insertion Loss (Typical 0.2dB)

- High Return Loss

- Scratch Free for Ferrule End-face

- Telcordia™GR-326 issue-3 compliance

- Meet the requirements of TIA-EIA-604-X

Applications- Transmission systems

- CATV, LAN systems

- Test Equipments

- Module Pigtailing

ILSINTECH

SpecificationITEM

Return Loss dB ≥50 ≥60

Apex Offset ≤50 ≤50㎛

Angular offset N/A 8.0 ± 0.5

SM or MM

Insertion Loss dB Typ. ≤ 0.2 Typ. ≤ 0.2

Connector Types

Radius of Curvature mm 7~25 5~12

nm -50 ~ +50 -100 ~ +100

˚

Protrusion or undercut

Fiber Types

Storage Temperature -40 ~ +85℃

Operating Temperature -40 ~ +75℃

Unit UPC APCSC, LC, FC, ST

Connector Key

Stress Applying PartsCoreCladdingFerrule

Slow Axis Fast Axis

Key Features- PANDA Fiber (Fujikura)

- High Extinction Ratio

- High Precision Axis Angle (<3˚)

- Scratch Free for Ferrule End-face

Key Features- Push-Pull Easy Connection

- Low Insertion Loss and High Return Loss

- IEC 61754-7, TIA 604-5(FOCIS 5) compliant

Applications- 10/40/100-GbE

- Cloud Computing

- Data Center

- Optical Switch and AWG

- Fiber Patch Panel

ILSINTECH’s Polarization-maintaining (PM) single mode optical Jumper cords

can be used in a number of applications, including high speed optical transmission

systems, interferometric sensors, LN modulators, DFB-LD, instrumentations and polarization

sensitive components.

ILSINTECH

Specification

SpecificationITEM

Return Loss dB ≥50 ≥60

Polarization Axis Options

Insertion Loss dBTyp. ≤ 0.15Max. ≤ 0.5

Typ. ≤ 0.2Max. ≤ 0.5

Typ. ≥ 30Max. ≥ 25

Typ. ≥ 30Max. ≥ 25

Connector Types

Extinction Ratio mm

Fiber Types

Key Options

Storage Temperature ℃

Operating Temperature ℃

Unit UPC APC

Slow, Fast

R (Reduced), N (Wide)

-40 ~ +85

-20 ~ +70

PANDA 1300, PANDA 1550 (0.25, 0.9, 3.0)

FC, SC

ITEM

Insertion Loss dB ≤0.5

Operating Temperature -40 to +75

OM1, OM2, OM3, OM4Fiber Types

Return Loss dB ≥30

°C

Unit Multimode

ComparisonMechanical & Pre-terminated Cord

Comparison: FTTH Fusion SOC with Mechanical Connector

1. Lower installation cost.- More than 50% cheaper than other fusion splice-on connectors (SOC) and same or lower than mechanical connector. ▶The best quality at low price.

2. Best transmission quality- The quality of fusion splice-on connectors have been verified as the best way in transmission sector (Backbone Network). ex) Swift connector insertion loss= 0.2dB below (average), mechanical connector, insertion loss = 0.5dB

3. Very low Maintenance Cost- Splice-on connector: Lifespan is approximately 15 years or more- Mechanical connector: Lifespan: 3~5 years. Because of drying of matching gel, maintenance service should be required within a year.

CONNECTORS

Connection Method

Application

Return Loss (dB)

Operation Time

Lift span

Insert Loss (dB)

Transmission Speed

G-PON, WDM-PON

UPC: >40dB / APC: >50 dB

Advantages

Disadvantages

Remark

- Low cost

- No expensive equipment

-

- Short life

- Skilled labor required

2~3 minute above

0.5 dB below

Below 100 Mbps

MECHANICAL CONNECTOR

Cost Middle

Temporary connection by V-groove method

Shorter life span (3~5 years)Dust, dirt, lower connectivity

FTTH, GE-PON, G-PON, WDM-PON

UPC: >50dB / APC: >60dB

- Fusion splicing- Best quality, Fast connection

- Korean government: 1 Gbps at 2012 (Giga Korea)- EU, USA, Japan: Adopt fusion splicing connector

2~3 minute

Permanent (15 years above)

0.2dB below (avg.)

Up to 2 Gbps

FTTH Fusion SOC

Low

Permanent connection by fusion splicer

- Required fusion splicer (recover investment within one year)- Training for operation

ILSINTECH

Connector < 0.2dB (FTTH SOC)

Fusion Splice Point < 0.05dB(Swift F1)OLT : Optical Line Terminal ODF : Optical Distribution Frame FDC : Fiber Distribution Center DP : Drop Point , Demarcation Point

OLT

FTBSplitter Splitter FWS

CO FDC DP Premise

ONT6Km 2Km

1:NODF 1:N

Swift F1+ ONT/ONU

FTTH Fusion SOC

Telcodia-GR -326

MDUFDC

Underground Splice Closure

FDC

10~20Km 1~2Km

1~2Km

ONU

ONT

Splitter 1:N

Splitter 1:N

MDF

COOLT

Fiber DP

Splitter

FTB : Fiber Termination BoxFWS : Fiber Wall Distribution SocketONU : Optical Network UnitONT : Optical Network Terminal

ODC / OTP / ONT Deployment

Data Center

- ILSINTECH Solution- High Durability → High Protection- High Quality → Low Loss

FTTH Fusion SOC Applications

Using pigtail Connector Using FTTH Fusion SOC

OTP mounted splitter ONT

Before After

Splice trays and protection sleeves are not necessary,which in turn keeps the space neat and open.

1. Neat & well organized

2. Cost save/competitive price - Reduced maintenance cost - No need special cabinet for extra cable storage - Reduced cable cost (G.657)

With FTTH Fusion SOC, it is very easy to maintain uniformity and tidiness.

3. Possible to adopt patch cord maintenance - No need to replace patch cord

- Save Installation Cost - Neat & well organized