LED Dimmable Panel Light with White Frame User Manual Part Number: Important: Read all instructions prior to installation. LPD-40K24-40 Surface Mounting Kit: LPD-SMK24 Recessed Mounting Kit: LPD-JBK Summary These 0-10V dimmable ETL Listed 2’x4’ recessed or surface mount panel lights are perfect for new construction applications or replacing existing fluorescent troffer fixtures with recessed installation. Use Recessed Mounting Kit (LPD-JBK) for T-bar ceiling installations. Use Surface Mounting Kit (LPD-SMK24) for surface mounting installations. Note: Recessed Mounting Kit Required (LPD-JBK) 1. Turn off power and remove existing fixture or remove ceiling tile. 2. Bend each t-bar suspension hook away from panel until facing perpendicular to panel backing. Bend hook arm until facing perpendicular to hook body. Hook panel light onto t-bar until panel is fully supported. (Fig. 2 & 3) 3. Remove the knock-out hole on the Junction Box. Run wiring through hole and secure. Insert supply Line and Neutral power wires into corresponding locations on orange quick disconnect. Line is labeled in black, neutral is white. Connect the green ground wire to supply ground wire. Connect the two orange quick disconnects together. Connect the 0~10V dimming wires according to the Wiring Diagram with wire nuts. (Fig. 4) 4. Attach Junction Box to panel backing by inserting the tabs from the Junction Box into the slots on the panel backing and secure with Thumb Screw. (Fig. 5) 4400 Earth City Expy, St. Louis, MO 63045 866-590-3533 superbrightleds.com Specifications Recessed Installation Input Voltage 100-277 VAC Input Power 40 Watts Input Current 343mA Lumens 4500 lm Color Temperature 4000K CRI 83 Efficacy 125 lm/w Temperature Range -4° ~ 104° F (-20° ~ 40°C) Dimensions L47.75” x W23.75” x H.67” (121.3 x 60.3 x 1.7cm) Panel Weight 16 lbs 5oz (7399g) J-Box Mounting Plate Weight 5lbs 4oz (2381g) Warranty 5 years Included Parts ming t to nd Figure2 Figure3 Figure4 Figure5 .67” 17.1mm 47.75” 1212.85mm 23.75” 603.23mm Even-Glow™ Series Recessed Mounting Kit (LPD-JBK) sold separately Surface Mounting Kit (LPD-SMK24) sold separately Panel Light (LPD-40K24-40) 1 - LED Light Panel with internal driver 1 - Junction Box 1 - Attachment Thumb Screw 1 - Surface Mount Bracket 7 - Screws 7 - Screw Anchors 1 - Cable Service Loop 1 - Cable Service Loop Screw Rev Date: V1 08/04/2016 Wiring Diagram Power Cycle Diagram 0-10V Dimmer D + D - PURPLE GREY LINE NEUTRAL GROUND PURPLE GREY RED BLACK BLACK WHITE GREEN LED PANEL Dimming Driver

Upload: vuongthu

Post on 09-May-2019

212 views

Category:

Documents


0 download

TRANSCRIPT

LED Dimmable Panel Light with White Frame

User ManualPart Number:

Important: Read all instructions prior to installation. LPD-40K24-40Surface Mounting Kit: LPD-SMK24Recessed Mounting Kit: LPD-JBK

Summary

These 0-10V dimmable ETL Listed 2’x4’ recessed or surface mount panel lights are perfect for new construction applications or replacing existing fl uorescent troff er fi xtures with recessed installation. Use Recessed Mounting Kit (LPD-JBK) for T-bar ceiling installations. Use Surface Mounting Kit (LPD-SMK24) for surface mounting installations.

Note: Recessed Mounting Kit Required (LPD-JBK)1. Turn off power and remove existing fixture or remove ceiling tile.

2. Bend each t-bar suspension hook away from panel until facing perpendicular to panel backing. Bend hook arm until facing perpendicular to hook body. Hook panel light onto t-bar until panel is fully supported. (Fig. 2 & 3)

3. Remove the knock-out hole on the Junction Box. Run wiring through hole and secure. Insert supply Line and Neutral power wires into corresponding locations on orange quick disconnect. Line is labeled in black, neutral is white. Connect the green ground wire to supply ground wire. Connect the two orange quick disconnects together. Connect the 0~10V dimming wires according to the Wiring Diagram with wire nuts. (Fig. 4)

4. Attach Junction Box to panel backing by inserting the tabs from the Junction Box into the slots on the panel backing and secure with Thumb Screw. (Fig. 5)

4400 Earth City Expy, St. Louis, MO 63045 866-590-3533 superbrightleds.com

Specifi cations

Recessed Installation

Input Voltage 100-277 VACInput Power 40 WattsInput Current 343mA

Lumens 4500 lmColor Temperature 4000K

CRI 83Effi cacy 125 lm/w

Temperature Range -4° ~ 104° F (-20° ~ 40°C)Dimensions L47.75” x W23.75” x H.67” (121.3 x 60.3 x

1.7cm)Panel Weight 16 lbs 5oz (7399g)

J-Box Mounting Plate Weight 5lbs 4oz (2381g)Warranty 5 years

Included Parts

FS SERIESSurface Mounted Kit Installation

FS SERIESSurface Mounted Kit Installation

S tep2: Turn off power. Insert the L,N wiresof the J-box into the male connector.

2

S tep6: Plug the female connector of the luminaire into the male connector of the AC input wire.The Ground connects to Green wire.Dimming wires connect according to the same wire color.

6

S tep4:Alight the 2 longer hooks on the metal plate with the longer hole on the luminaire(Look at the metal palte and the luminaire with the 'STEP 1' mark). Slightly move the luminaire forward and make sure the hooks is in right position.

4

S te p1: Remove the surface mounted kit from the luminaire.

1

S te p5: Fix the metal string on the hook.(Fig.2)

5

S tep3:Align the holes on the surface mounted kit withthe hole on the J-box Tighten 2#8-32 screws, rotatethe plate to your right position and lots of KA3.5*20mmscrews into the ceiling and make the kit flush withthe ceiling.

3

Step8: Push the luminaire on the ceiling. Makesure the 4 hooks are inside the luminaire and push forward the luminaire until you hear a clicking sound.

8-1

S te p7: Put the wire into the J-box.

7-1

8-2

2

RECESSED INST ALLA TION

FS SERIESFS SERIES INST ALLA TION

Please read this entire manual to fully understand and safely use this product. Specifications are subject to change without notice.Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.Report any damage and save all packing materials if any part(s) were damaged during shipping.Do not attempt to use this apparatus if it is damaged.

UNP ACKING1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ ALL INSTRUCTIONS BEFORE INST ALLA TION1

2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.The product should be installed and operated by a qualified electrician or technician in with relevant local codes.

accordance

Risk of electric shock. Ensure that main power source is off when wiring or soldering the of the product.

sections

Before installing this fixture or doing any maintenance, make sure to turn off the power the circuit breaker or fuse box.

supply at

Check to make sure that all fixture connections have been properly made and the fixture grounded to avoid potential electrical shocks.

is

Do in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or

This conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current

OPTIONALFS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA TION

CAUTION: Risk of Electric Shock!

Accessory:LED Luminaire

Installation instruction

Surface mounted kit (for surface mounted)

J-box ( for recessed )

page 2page 1 page 4page 3

RECESSED INST ALLA TION

Step3: Turn off power,remove the ceiling panel. Then place the panel in to the T-bar,ensure he panel is attached to the ceiling.(Figure3)

Step4:connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and

Step5:tightly.the line connect to the connector with the blackmark, the natural connect to another,the ground connectto the green wire.(Figure4)

Put a connector to the end of AC input wire and

Step1: Remove the surface mounted kit from the luminaire.

Step2: Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical tothe rear cover of panel light.

Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).

please use switch to dim and don’t need to connect the dimmingwire. Dimming step: Fristly , Turn on to 100% brightnessSecondly ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp is in 50% brightness, At last ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp 10% brightness. (Figure 7)Note: For cycle of step dimming, wait until the lamp is in brightness. For failure of step dimming, turn off the lamp and turn on after 3 second.

For Step Dimming

,

For 0-10V Dimming

The driver PUR (D+) to the dimmer+(PUR),and the driver GRY(D-)to the dimmer-(GRY)Connect the wires with terminal cap as shown in wiring diagram (Figure 6).Incoming insulated dimming conductors shall have voltage rated at least equal to the branch voltage.

Compatible with 0-10V dimmer

Figure1

Figure2 Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10VDimmer

D +D -

PURPLEGREY

LNG

PURPLEGREY

RED BLACK

BLACKWHITEGROUND

LED PANEL

Dim

ming

Driver

Figure6

Step Dimming

One Cycle

Note: After 3s turn on lamp to 100% brightness.

Turn Off Lamp

Turn Off Lamp

Turn OffLamp

Turn On Lamp10%

brightness

Turn On Lamp50%

brightness

Turn On Lamp100%

brightness

After 0.5S At 0.5-2s

At 0.5-2sAfter 0.5S

After 0.5S

Figure7

To r i g h t p o s i ti o n It is the r ight pos ition whic h is the longer hook s of the firs t groove.

7-2

1

2

3

4

R ight pos ition

.67”17.1mm

47.75”1212.85mm

23.75”603.23mm

Even-Glow™ Series

Recessed Mounting Kit (LPD-JBK) sold separately

Surface Mounting Kit (LPD-SMK24) sold separately

Panel Light (LPD-40K24-40)1 - LED Light Panel with internal driver

1 - Junction Box1 - Attachment Thumb Screw

1 - Surface Mount Bracket7 - Screws7 - Screw Anchors1 - Cable Service Loop1 - Cable Service Loop Screw

Rev Date: V1 08/04/2016

Wiring Diagram

Power Cycle Diagram

WIRING DIAGRAM

0-10VDimmer

D +D -

PURPLEGREY

LINENEUTRALGROUND

PURPLEGREY

RED BLACK

BLACKWHITEGREEN

LED PANEL

Dim

ming

Driver

User ManualPart Number:

4400 Earth City Expy, St. Louis, MO 63045 866-590-3533 superbrightleds.com

Surface Mounted Kit InstallationLPD-40K22-40

Surface Mounting Kit: LPD-SMK22Recessed Mounting Kit: LPD-JBK

Rev Date: V1 08/04/2016

FS SERIESSurface Mounted Kit Installation

FS SERIESSurface Mounted Kit Installation

S tep2: Turn off power. Insert the L,N wiresof the J-box into the male connector.

2

S tep6: Plug the female connector of the luminaire into the male connector of the AC input wire.The Ground connects to Green wire.Dimming wires connect according to the same wire color.

6

S tep4:Alight the 2 longer hooks on the metal plate with the longer hole on the luminaire(Look at the metal palte and the luminaire with the 'STEP 1' mark). Slightly move the luminaire forward and make sure the hooks is in right position.

4

S te p1: Remove the surface mounted kit from the luminaire.

1

S te p5: Fix the metal string on the hook.(Fig.2)

5

S tep3:Align the holes on the surface mounted kit withthe hole on the J-box Tighten 2#8-32 screws, rotatethe plate to your right position and lots of KA3.5*20mmscrews into the ceiling and make the kit flush withthe ceiling.

3

Step8: Push the luminaire on the ceiling. Makesure the 4 hooks are inside the luminaire and push forward the luminaire until you hear a clicking sound.

8-1

S te p7: Put the wire into the J-box.

7-1

8-2

2

RECESSED INST ALLA TION

FS SERIESFS SERIES INST ALLA TION

Please read this entire manual to fully understand and safely use this product. Specifications are subject to change without notice.Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.Report any damage and save all packing materials if any part(s) were damaged during shipping.Do not attempt to use this apparatus if it is damaged.

UNP ACKING1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ ALL INSTRUCTIONS BEFORE INST ALLA TION1

2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.The product should be installed and operated by a qualified electrician or technician in with relevant local codes.

accordance

Risk of electric shock. Ensure that main power source is off when wiring or soldering the of the product.

sections

Before installing this fixture or doing any maintenance, make sure to turn off the power the circuit breaker or fuse box.

supply at

Check to make sure that all fixture connections have been properly made and the fixture grounded to avoid potential electrical shocks.

is

Do in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or

This conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current

OPTIONALFS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA TION

CAUTION: Risk of Electric Shock!

Accessory:LED Luminaire

Installation instruction

Surface mounted kit (for surface mounted)

J-box ( for recessed )

page 2page 1 page 4page 3

RECESSED INST ALLA TION

Step3: Turn off power,remove the ceiling panel. Then place the panel in to the T-bar,ensure he panel is attached to the ceiling.(Figure3)

Step4:connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and

Step5:tightly.the line connect to the connector with the blackmark, the natural connect to another,the ground connectto the green wire.(Figure4)

Put a connector to the end of AC input wire and

Step1: Remove the surface mounted kit from the luminaire.

Step2: Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical tothe rear cover of panel light.

Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).

please use switch to dim and don’t need to connect the dimmingwire. Dimming step: Fristly , Turn on to 100% brightnessSecondly ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp is in 50% brightness, At last ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp 10% brightness. (Figure 7)Note: For cycle of step dimming, wait until the lamp is in brightness. For failure of step dimming, turn off the lamp and turn on after 3 second.

For Step Dimming

,

For 0-10V Dimming

The driver PUR (D+) to the dimmer+(PUR),and the driver GRY(D-)to the dimmer-(GRY)Connect the wires with terminal cap as shown in wiring diagram (Figure 6).Incoming insulated dimming conductors shall have voltage rated at least equal to the branch voltage.

Compatible with 0-10V dimmer

Figure1

Figure2 Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10VDimmer

D +D -

PURPLEGREY

LNG

PURPLEGREY

RED BLACK

BLACKWHITEGROUND

LED PANEL

Dim

ming

Driver

Figure6

Step Dimming

One Cycle

Note: After 3s turn on lamp to 100% brightness.

Turn Off Lamp

Turn Off Lamp

Turn OffLamp

Turn On Lamp10%

brightness

Turn On Lamp50%

brightness

Turn On Lamp100%

brightness

After 0.5S At 0.5-2s

At 0.5-2sAfter 0.5S

After 0.5S

Figure7

To r i g h t p o s i ti o n It is the r ight pos ition whic h is the longer hook s of the firs t groove.

7-2

1

2

3

4

R ight pos ition

FS SERIESSurface Mounted Kit Installation

FS SERIESSurface Mounted Kit Installation

S tep2: Turn off power. Insert the L,N wiresof the J-box into the male connector.

2

S tep6: Plug the female connector of the luminaire into the male connector of the AC input wire.The Ground connects to Green wire.Dimming wires connect according to the same wire color.

6

S tep4:Alight the 2 longer hooks on the metal plate with the longer hole on the luminaire(Look at the metal palte and the luminaire with the 'STEP 1' mark). Slightly move the luminaire forward and make sure the hooks is in right position.

4

S te p1: Remove the surface mounted kit from the luminaire.

1

S te p5: Fix the metal string on the hook.(Fig.2)

5

S tep3:Align the holes on the surface mounted kit withthe hole on the J-box Tighten 2#8-32 screws, rotatethe plate to your right position and lots of KA3.5*20mmscrews into the ceiling and make the kit flush withthe ceiling.

3

Step8: Push the luminaire on the ceiling. Makesure the 4 hooks are inside the luminaire and push forward the luminaire until you hear a clicking sound.

8-1

S te p7: Put the wire into the J-box.

7-1

8-2

2

RECESSED INST ALLA TION

FS SERIESFS SERIES INST ALLA TION

Please read this entire manual to fully understand and safely use this product. Specifications are subject to change without notice.Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.Report any damage and save all packing materials if any part(s) were damaged during shipping.Do not attempt to use this apparatus if it is damaged.

UNP ACKING1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ ALL INSTRUCTIONS BEFORE INST ALLA TION1

2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.The product should be installed and operated by a qualified electrician or technician in with relevant local codes.

accordance

Risk of electric shock. Ensure that main power source is off when wiring or soldering the of the product.

sections

Before installing this fixture or doing any maintenance, make sure to turn off the power the circuit breaker or fuse box.

supply at

Check to make sure that all fixture connections have been properly made and the fixture grounded to avoid potential electrical shocks.

is

Do in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or

This conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current

OPTIONALFS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA TION

CAUTION: Risk of Electric Shock!

Accessory:LED Luminaire

Installation instruction

Surface mounted kit (for surface mounted)

J-box ( for recessed )

page 2page 1 page 4page 3

RECESSED INST ALLA TION

Step3: Turn off power,remove the ceiling panel. Then place the panel in to the T-bar,ensure he panel is attached to the ceiling.(Figure3)

Step4:connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and

Step5:tightly.the line connect to the connector with the blackmark, the natural connect to another,the ground connectto the green wire.(Figure4)

Put a connector to the end of AC input wire and

Step1: Remove the surface mounted kit from the luminaire.

Step2: Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical tothe rear cover of panel light.

Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).

please use switch to dim and don’t need to connect the dimmingwire. Dimming step: Fristly , Turn on to 100% brightnessSecondly ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp is in 50% brightness, At last ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp 10% brightness. (Figure 7)Note: For cycle of step dimming, wait until the lamp is in brightness. For failure of step dimming, turn off the lamp and turn on after 3 second.

For Step Dimming

,

For 0-10V Dimming

The driver PUR (D+) to the dimmer+(PUR),and the driver GRY(D-)to the dimmer-(GRY)Connect the wires with terminal cap as shown in wiring diagram (Figure 6).Incoming insulated dimming conductors shall have voltage rated at least equal to the branch voltage.

Compatible with 0-10V dimmer

Figure1

Figure2 Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10VDimmer

D +D -

PURPLEGREY

LNG

PURPLEGREY

RED BLACK

BLACKWHITEGROUND

LED PANEL

Dim

ming

Driver

Figure6

Step Dimming

One Cycle

Note: After 3s turn on lamp to 100% brightness.

Turn Off Lamp

Turn Off Lamp

Turn OffLamp

Turn On Lamp10%

brightness

Turn On Lamp50%

brightness

Turn On Lamp100%

brightness

After 0.5S At 0.5-2s

At 0.5-2sAfter 0.5S

After 0.5S

Figure7

To r i g h t p o s i ti o n It is the r ight pos ition whic h is the longer hook s of the firs t groove.

7-2

1

2

3

4

R ight pos ition

FS SERIESSurface Mounted Kit Installation

FS SERIESSurface Mounted Kit Installation

S tep2: Turn off power. Insert the L,N wiresof the J-box into the male connector.

2

S tep6: Plug the female connector of the luminaire into the male connector of the AC input wire.The Ground connects to Green wire.Dimming wires connect according to the same wire color.

6

S tep4:Alight the 2 longer hooks on the metal plate with the longer hole on the luminaire(Look at the metal palte and the luminaire with the 'STEP 1' mark). Slightly move the luminaire forward and make sure the hooks is in right position.

4

S te p1: Remove the surface mounted kit from the luminaire.

1

S te p5: Fix the metal string on the hook.(Fig.2)

5

S tep3:Align the holes on the surface mounted kit withthe hole on the J-box Tighten 2#8-32 screws, rotatethe plate to your right position and lots of KA3.5*20mmscrews into the ceiling and make the kit flush withthe ceiling.

3

Step8: Push the luminaire on the ceiling. Makesure the 4 hooks are inside the luminaire and push forward the luminaire until you hear a clicking sound.

8-1

S te p7: Put the wire into the J-box.

7-1

8-2

2

RECESSED INST ALLA TION

FS SERIESFS SERIES INST ALLA TION

Please read this entire manual to fully understand and safely use this product. Specifications are subject to change without notice.Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.Report any damage and save all packing materials if any part(s) were damaged during shipping.Do not attempt to use this apparatus if it is damaged.

UNP ACKING1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ ALL INSTRUCTIONS BEFORE INST ALLA TION1

2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.The product should be installed and operated by a qualified electrician or technician in with relevant local codes.

accordance

Risk of electric shock. Ensure that main power source is off when wiring or soldering the of the product.

sections

Before installing this fixture or doing any maintenance, make sure to turn off the power the circuit breaker or fuse box.

supply at

Check to make sure that all fixture connections have been properly made and the fixture grounded to avoid potential electrical shocks.

is

Do in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or

This conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current

OPTIONALFS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA TION

CAUTION: Risk of Electric Shock!

Accessory:LED Luminaire

Installation instruction

Surface mounted kit (for surface mounted)

J-box ( for recessed )

page 2page 1 page 4page 3

RECESSED INST ALLA TION

Step3: Turn off power,remove the ceiling panel. Then place the panel in to the T-bar,ensure he panel is attached to the ceiling.(Figure3)

Step4:connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and

Step5:tightly.the line connect to the connector with the blackmark, the natural connect to another,the ground connectto the green wire.(Figure4)

Put a connector to the end of AC input wire and

Step1: Remove the surface mounted kit from the luminaire.

Step2: Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical tothe rear cover of panel light.

Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).

please use switch to dim and don’t need to connect the dimmingwire. Dimming step: Fristly , Turn on to 100% brightnessSecondly ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp is in 50% brightness, At last ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp 10% brightness. (Figure 7)Note: For cycle of step dimming, wait until the lamp is in brightness. For failure of step dimming, turn off the lamp and turn on after 3 second.

For Step Dimming

,

For 0-10V Dimming

The driver PUR (D+) to the dimmer+(PUR),and the driver GRY(D-)to the dimmer-(GRY)Connect the wires with terminal cap as shown in wiring diagram (Figure 6).Incoming insulated dimming conductors shall have voltage rated at least equal to the branch voltage.

Compatible with 0-10V dimmer

Figure1

Figure2 Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10VDimmer

D +D -

PURPLEGREY

LNG

PURPLEGREY

RED BLACK

BLACKWHITEGROUND

LED PANEL

Dim

ming

Driver

Figure6

Step Dimming

One Cycle

Note: After 3s turn on lamp to 100% brightness.

Turn Off Lamp

Turn Off Lamp

Turn OffLamp

Turn On Lamp10%

brightness

Turn On Lamp50%

brightness

Turn On Lamp100%

brightness

After 0.5S At 0.5-2s

At 0.5-2sAfter 0.5S

After 0.5S

Figure7

To r i g h t p o s i ti o n It is the r ight pos ition whic h is the longer hook s of the firs t groove.

7-2

1

2

3

4

R ight pos ition

FS SERIESSurface Mounted Kit Installation

FS SERIESSurface Mounted Kit Installation

S tep2: Turn off power. Insert the L,N wiresof the J-box into the male connector.

2

S tep6: Plug the female connector of the luminaire into the male connector of the AC input wire.The Ground connects to Green wire.Dimming wires connect according to the same wire color.

6

S tep4:Alight the 2 longer hooks on the metal plate with the longer hole on the luminaire(Look at the metal palte and the luminaire with the 'STEP 1' mark). Slightly move the luminaire forward and make sure the hooks is in right position.

4

S te p1: Remove the surface mounted kit from the luminaire.

1

S te p5: Fix the metal string on the hook.(Fig.2)

5

S tep3:Align the holes on the surface mounted kit withthe hole on the J-box Tighten 2#8-32 screws, rotatethe plate to your right position and lots of KA3.5*20mmscrews into the ceiling and make the kit flush withthe ceiling.

3

Step8: Push the luminaire on the ceiling. Makesure the 4 hooks are inside the luminaire and push forward the luminaire until you hear a clicking sound.

8-1

S te p7: Put the wire into the J-box.

7-1

8-2

2

RECESSED INST ALLA TION

FS SERIESFS SERIES INST ALLA TION

Please read this entire manual to fully understand and safely use this product. Specifications are subject to change without notice.Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.Report any damage and save all packing materials if any part(s) were damaged during shipping.Do not attempt to use this apparatus if it is damaged.

UNP ACKING1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ ALL INSTRUCTIONS BEFORE INST ALLA TION1

2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.The product should be installed and operated by a qualified electrician or technician in with relevant local codes.

accordance

Risk of electric shock. Ensure that main power source is off when wiring or soldering the of the product.

sections

Before installing this fixture or doing any maintenance, make sure to turn off the power the circuit breaker or fuse box.

supply at

Check to make sure that all fixture connections have been properly made and the fixture grounded to avoid potential electrical shocks.

is

Do in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or

This conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current

OPTIONALFS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA TION

CAUTION: Risk of Electric Shock!

Accessory:LED Luminaire

Installation instruction

Surface mounted kit (for surface mounted)

J-box ( for recessed )

page 2page 1 page 4page 3

RECESSED INST ALLA TION

Step3: Turn off power,remove the ceiling panel. Then place the panel in to the T-bar,ensure he panel is attached to the ceiling.(Figure3)

Step4:connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and

Step5:tightly.the line connect to the connector with the blackmark, the natural connect to another,the ground connectto the green wire.(Figure4)

Put a connector to the end of AC input wire and

Step1: Remove the surface mounted kit from the luminaire.

Step2: Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical tothe rear cover of panel light.

Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).

please use switch to dim and don’t need to connect the dimmingwire. Dimming step: Fristly , Turn on to 100% brightnessSecondly ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp is in 50% brightness, At last ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp 10% brightness. (Figure 7)Note: For cycle of step dimming, wait until the lamp is in brightness. For failure of step dimming, turn off the lamp and turn on after 3 second.

For Step Dimming

,

For 0-10V Dimming

The driver PUR (D+) to the dimmer+(PUR),and the driver GRY(D-)to the dimmer-(GRY)Connect the wires with terminal cap as shown in wiring diagram (Figure 6).Incoming insulated dimming conductors shall have voltage rated at least equal to the branch voltage.

Compatible with 0-10V dimmer

Figure1

Figure2 Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10VDimmer

D +D -

PURPLEGREY

LNG

PURPLEGREY

RED BLACK

BLACKWHITEGROUND

LED PANEL

Dim

ming

Driver

Figure6

Step Dimming

One Cycle

Note: After 3s turn on lamp to 100% brightness.

Turn Off Lamp

Turn Off Lamp

Turn OffLamp

Turn On Lamp10%

brightness

Turn On Lamp50%

brightness

Turn On Lamp100%

brightness

After 0.5S At 0.5-2s

At 0.5-2sAfter 0.5S

After 0.5S

Figure7

To r i g h t p o s i ti o n It is the r ight pos ition whic h is the longer hook s of the firs t groove.

7-2

1

2

3

4

R ight pos ition

FS SERIESSurface Mounted Kit Installation

FS SERIESSurface Mounted Kit Installation

S tep2: Turn off power. Insert the L,N wiresof the J-box into the male connector.

2

S tep6: Plug the female connector of the luminaire into the male connector of the AC input wire.The Ground connects to Green wire.Dimming wires connect according to the same wire color.

6

S tep4:Alight the 2 longer hooks on the metal plate with the longer hole on the luminaire(Look at the metal palte and the luminaire with the 'STEP 1' mark). Slightly move the luminaire forward and make sure the hooks is in right position.

4

S te p1: Remove the surface mounted kit from the luminaire.

1

S te p5: Fix the metal string on the hook.(Fig.2)

5

S tep3:Align the holes on the surface mounted kit withthe hole on the J-box Tighten 2#8-32 screws, rotatethe plate to your right position and lots of KA3.5*20mmscrews into the ceiling and make the kit flush withthe ceiling.

3

Step8: Push the luminaire on the ceiling. Makesure the 4 hooks are inside the luminaire and push forward the luminaire until you hear a clicking sound.

8-1

S te p7: Put the wire into the J-box.

7-1

8-2

2

RECESSED INST ALLA TION

FS SERIESFS SERIES INST ALLA TION

Please read this entire manual to fully understand and safely use this product. Specifications are subject to change without notice.Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.Report any damage and save all packing materials if any part(s) were damaged during shipping.Do not attempt to use this apparatus if it is damaged.

UNP ACKING1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ ALL INSTRUCTIONS BEFORE INST ALLA TION1

2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.The product should be installed and operated by a qualified electrician or technician in with relevant local codes.

accordance

Risk of electric shock. Ensure that main power source is off when wiring or soldering the of the product.

sections

Before installing this fixture or doing any maintenance, make sure to turn off the power the circuit breaker or fuse box.

supply at

Check to make sure that all fixture connections have been properly made and the fixture grounded to avoid potential electrical shocks.

is

Do in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or

This conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current

OPTIONALFS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA TION

CAUTION: Risk of Electric Shock!

Accessory:LED Luminaire

Installation instruction

Surface mounted kit (for surface mounted)

J-box ( for recessed )

page 2page 1 page 4page 3

RECESSED INST ALLA TION

Step3: Turn off power,remove the ceiling panel. Then place the panel in to the T-bar,ensure he panel is attached to the ceiling.(Figure3)

Step4:connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and

Step5:tightly.the line connect to the connector with the blackmark, the natural connect to another,the ground connectto the green wire.(Figure4)

Put a connector to the end of AC input wire and

Step1: Remove the surface mounted kit from the luminaire.

Step2: Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical tothe rear cover of panel light.

Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).

please use switch to dim and don’t need to connect the dimmingwire. Dimming step: Fristly , Turn on to 100% brightnessSecondly ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp is in 50% brightness, At last ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp 10% brightness. (Figure 7)Note: For cycle of step dimming, wait until the lamp is in brightness. For failure of step dimming, turn off the lamp and turn on after 3 second.

For Step Dimming

,

For 0-10V Dimming

The driver PUR (D+) to the dimmer+(PUR),and the driver GRY(D-)to the dimmer-(GRY)Connect the wires with terminal cap as shown in wiring diagram (Figure 6).Incoming insulated dimming conductors shall have voltage rated at least equal to the branch voltage.

Compatible with 0-10V dimmer

Figure1

Figure2 Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10VDimmer

D +D -

PURPLEGREY

LNG

PURPLEGREY

RED BLACK

BLACKWHITEGROUND

LED PANEL

Dim

ming

Driver

Figure6

Step Dimming

One Cycle

Note: After 3s turn on lamp to 100% brightness.

Turn Off Lamp

Turn Off Lamp

Turn OffLamp

Turn On Lamp10%

brightness

Turn On Lamp50%

brightness

Turn On Lamp100%

brightness

After 0.5S At 0.5-2s

At 0.5-2sAfter 0.5S

After 0.5S

Figure7

To r i g h t p o s i ti o n It is the r ight pos ition whic h is the longer hook s of the firs t groove.

7-2

1

2

3

4

R ight pos itionFS SERIESSurface Mounted Kit Installation

FS SERIESSurface Mounted Kit Installation

S tep2: Turn off power. Insert the L,N wiresof the J-box into the male connector.

2

S tep6: Plug the female connector of the luminaire into the male connector of the AC input wire.The Ground connects to Green wire.Dimming wires connect according to the same wire color.

6

S tep4:Alight the 2 longer hooks on the metal plate with the longer hole on the luminaire(Look at the metal palte and the luminaire with the 'STEP 1' mark). Slightly move the luminaire forward and make sure the hooks is in right position.

4

S te p1: Remove the surface mounted kit from the luminaire.

1

S te p5: Fix the metal string on the hook.(Fig.2)

5

S tep3:Align the holes on the surface mounted kit withthe hole on the J-box Tighten 2#8-32 screws, rotatethe plate to your right position and lots of KA3.5*20mmscrews into the ceiling and make the kit flush withthe ceiling.

3

Step8: Push the luminaire on the ceiling. Makesure the 4 hooks are inside the luminaire and push forward the luminaire until you hear a clicking sound.

8-1

S te p7: Put the wire into the J-box.

7-1

8-2

2

RECESSED INST ALLA TION

FS SERIESFS SERIES INST ALLA TION

Please read this entire manual to fully understand and safely use this product. Specifications are subject to change without notice.Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.Report any damage and save all packing materials if any part(s) were damaged during shipping.Do not attempt to use this apparatus if it is damaged.

UNP ACKING1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ ALL INSTRUCTIONS BEFORE INST ALLA TION1

2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.The product should be installed and operated by a qualified electrician or technician in with relevant local codes.

accordance

Risk of electric shock. Ensure that main power source is off when wiring or soldering the of the product.

sections

Before installing this fixture or doing any maintenance, make sure to turn off the power the circuit breaker or fuse box.

supply at

Check to make sure that all fixture connections have been properly made and the fixture grounded to avoid potential electrical shocks.

is

Do in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or

This conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current

OPTIONALFS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA TION

CAUTION: Risk of Electric Shock!

Accessory:LED Luminaire

Installation instruction

Surface mounted kit (for surface mounted)

J-box ( for recessed )

page 2page 1 page 4page 3

RECESSED INST ALLA TION

Step3: Turn off power,remove the ceiling panel. Then place the panel in to the T-bar,ensure he panel is attached to the ceiling.(Figure3)

Step4:connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and

Step5:tightly.the line connect to the connector with the blackmark, the natural connect to another,the ground connectto the green wire.(Figure4)

Put a connector to the end of AC input wire and

Step1: Remove the surface mounted kit from the luminaire.

Step2: Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical tothe rear cover of panel light.

Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).

please use switch to dim and don’t need to connect the dimmingwire. Dimming step: Fristly , Turn on to 100% brightnessSecondly ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp is in 50% brightness, At last ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp 10% brightness. (Figure 7)Note: For cycle of step dimming, wait until the lamp is in brightness. For failure of step dimming, turn off the lamp and turn on after 3 second.

For Step Dimming

,

For 0-10V Dimming

The driver PUR (D+) to the dimmer+(PUR),and the driver GRY(D-)to the dimmer-(GRY)Connect the wires with terminal cap as shown in wiring diagram (Figure 6).Incoming insulated dimming conductors shall have voltage rated at least equal to the branch voltage.

Compatible with 0-10V dimmer

Figure1

Figure2 Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10VDimmer

D +D -

PURPLEGREY

LNG

PURPLEGREY

RED BLACK

BLACKWHITEGROUND

LED PANEL

Dim

ming

Driver

Figure6

Step Dimming

One Cycle

Note: After 3s turn on lamp to 100% brightness.

Turn Off Lamp

Turn Off Lamp

Turn OffLamp

Turn On Lamp10%

brightness

Turn On Lamp50%

brightness

Turn On Lamp100%

brightness

After 0.5S At 0.5-2s

At 0.5-2sAfter 0.5SAfter 0.5S

Figure7

To r i g h t p o s i ti o n It is the r ight pos ition whic h is the longer hook s of the firs t groove.

7-2

1

2

3

4

R ight pos ition

FS SERIESSurface Mounted Kit Installation

FS SERIESSurface Mounted Kit Installation

S tep2: Turn off power. Insert the L,N wiresof the J-box into the male connector.

2

S tep6: Plug the female connector of the luminaire into the male connector of the AC input wire.The Ground connects to Green wire.Dimming wires connect according to the same wire color.

6

S tep4:Alight the 2 longer hooks on the metal plate with the longer hole on the luminaire(Look at the metal palte and the luminaire with the 'STEP 1' mark). Slightly move the luminaire forward and make sure the hooks is in right position.

4

S te p1: Remove the surface mounted kit from the luminaire.

1

S te p5: Fix the metal string on the hook.(Fig.2)

5

S tep3:Align the holes on the surface mounted kit withthe hole on the J-box Tighten 2#8-32 screws, rotatethe plate to your right position and lots of KA3.5*20mmscrews into the ceiling and make the kit flush withthe ceiling.

3

Step8: Push the luminaire on the ceiling. Makesure the 4 hooks are inside the luminaire and push forward the luminaire until you hear a clicking sound.

8-1

S te p7: Put the wire into the J-box.

7-1

8-2

2

RECESSED INST ALLA TION

FS SERIESFS SERIES INST ALLA TION

Please read this entire manual to fully understand and safely use this product. Specifications are subject to change without notice.Please visit our website the most recent user guide versions.

NOTE

Unpack and carefully examine the product.Report any damage and save all packing materials if any part(s) were damaged during shipping.Do not attempt to use this apparatus if it is damaged.

UNP ACKING1

2

3

Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.

READ ALL INSTRUCTIONS BEFORE INST ALLA TION1

2

3

4

5

6

7

8

Consult a qualified electrician to ensure correct branch circuit conductor.The product should be installed and operated by a qualified electrician or technician in with relevant local codes.

accordance

Risk of electric shock. Ensure that main power source is off when wiring or soldering the of the product.

sections

Before installing this fixture or doing any maintenance, make sure to turn off the power the circuit breaker or fuse box.

supply at

Check to make sure that all fixture connections have been properly made and the fixture grounded to avoid potential electrical shocks.

is

Do in water.

not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or

This conditions to ensure safety to human body.

panel lights are normally set to work at extra low voltage below DC42V and constant current

OPTIONALFS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**

Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings

IMPORT ANT SAFETYINFORMA TION

CAUTION: Risk of Electric Shock!

Accessory:LED Luminaire

Installation instruction

Surface mounted kit (for surface mounted)

J-box ( for recessed )

page 2page 1 page 4page 3

RECESSED INST ALLA TION

Step3: Turn off power,remove the ceiling panel. Then place the panel in to the T-bar,ensure he panel is attached to the ceiling.(Figure3)

Step4:connect conduit to J-box with proper connector(s).

Remove appropriate round knock-out(s) and

Step5:tightly.the line connect to the connector with the blackmark, the natural connect to another,the ground connectto the green wire.(Figure4)

Put a connector to the end of AC input wire and

Step1: Remove the surface mounted kit from the luminaire.

Step2: Same to 4 hang buckles.(Figure 2)

Bend hang buckle by 90° making it vertical tothe rear cover of panel light.

Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).

please use switch to dim and don’t need to connect the dimmingwire. Dimming step: Fristly , Turn on to 100% brightnessSecondly ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp is in 50% brightness, At last ,It takes about 0.5~2 seconds from turn off the light to next trun on and lamp 10% brightness. (Figure 7)Note: For cycle of step dimming, wait until the lamp is in brightness. For failure of step dimming, turn off the lamp and turn on after 3 second.

For Step Dimming

,

For 0-10V Dimming

The driver PUR (D+) to the dimmer+(PUR),and the driver GRY(D-)to the dimmer-(GRY)Connect the wires with terminal cap as shown in wiring diagram (Figure 6).Incoming insulated dimming conductors shall have voltage rated at least equal to the branch voltage.

Compatible with 0-10V dimmer

Figure1

Figure2 Figure3

Figure4

Figure5

WIRING DIAGRAM

0-10VDimmer

D +D -

PURPLEGREY

LNG

PURPLEGREY

RED BLACK

BLACKWHITEGROUND

LED PANEL

Dim

ming

Driver

Figure6

Step Dimming

One Cycle

Note: After 3s turn on lamp to 100% brightness.

Turn Off Lamp

Turn Off Lamp

Turn OffLamp

Turn On Lamp10%

brightness

Turn On Lamp50%

brightness

Turn On Lamp100%

brightness

After 0.5S At 0.5-2s

At 0.5-2sAfter 0.5S

After 0.5S

Figure7

To r i g h t p o s i ti o n It is the r ight pos ition whic h is the longer hook s of the firs t groove.

7-2

1

2

3

4

R ight pos ition

1. Remove Surface Mounting Kit and panel from packaging.2. Turn off power and run supply wiring through J-box. Insert supply line and neutral power wires into corresponding locations on orange quick disconnect. Line is labeled in black, neutral is white. (Fig. 2)

3. Temporarily attach Surface Mounting Kit to J-box and align to the desired orientation. Mark screw holes and drill pilot holes then remove Surface Mounting Kit. Insert screw anchors into mounting surface at marks. Reinstall Surface Mounting Kit to junction box and install screws to screw anchors. (Fig. 3)

4. Screw Steel Cable Service Loop to light panel (see Fig.5). Align the longer hooks labeled “Step 1” on the Surface Mounting Bracket to the larger slots along the edge of the panel backing labeled “Step 1” and slide to the fi rst notch. (Fig. 4)

5. Attach the Steel Cable Service Loop from the panel to one of the Surface Mount Kit hooks. Loop holds the panel while wiring. (Fig. 5)

6. Connect the green ground wire to supply ground wire. Connect the two orange quick disconnects together. Connect the 0~10V dimming wires according to the Wiring Diagram with wire nuts. (Fig. 6)

7. Tuck wiring into junction box being sure not to pinch wires. (Fig. 7-1 & 7-2)

8. Lift panel onto remaining hooks on Surface Mounting Bracket while aligning to remaining slots on panel. Slide panel the same direction as step 4 until the panel locks into the second notch. (Fig. 8-1 & 8-2)

Screw

Screw

• This product should be installed by a fully certifi ed electrician in accordance with local building and electrical codes

• Due to risk of electric shock, ensure that the main power source and circuit breakers are switched off before performing any installation or wiring procedures

• Do not install insulation within 2 in / 51mm of any part of the panel light fi xture.

Safety Information

CAUTION! Risk Of Electric Shock

Turn off all power prior to installation by switching off circuit breaker or removing fuse at fuse box.