fps212 3f01 diagnostic check

Upload: zlrig

Post on 30-Oct-2015

12 views

Category:

Documents


1 download

DESCRIPTION

FPS212-3F01- Diagnostic check

TRANSCRIPT

  • 7/15/2019 FPS212 3F01 Diagnostic Check

    1/2

    230V AC

    Front LED

    230V AC

    PSU

    5Volt Always on PSU

    Backlight Inverter

    Main Control PWB

    5V=on, 0V=off

    Infra Red

    Receiver

    12V + 24V switched Power

    supply

    12+24V enable

    B'light enable

    Over Current

    Shut down

    12V Switched

    5,6,7+8 CNS2 10 9

    5V

    Micro

    Periferal supplies,

    Tuner, TFT driver etc...

    TFT display

    24V Switched

    CNS1

    7,8,9

    10

    5+6

    11

    12

    CNS1,2 pins 1,2,3

    & 4 = Ground

  • 7/15/2019 FPS212 3F01 Diagnostic Check

    2/2

    TV Dead / No Backlight Illumination

    Front LED working or notSuspect PSU diagnosis

    This should only be used as a guide to faultfinding. I do not accept liability for any inaccuracies. This guide is produced

    solely by loudi out of desperation as info on this PCB is non existent - I am just sharing my own findings/ research :@)

    Check Voltage

    on CNS1 pin 7-9

    4.5>5V?

    Yes

    NO

    faulty PSU

    Suspect IC2 Q4BD1 C1 etc..

    Check Voltage

    on CNS1 pin 10

    With TV

    switched on

    3>5V?

    Yes

    NO

    Main Control PCB Faulty

    (Try Hard Reset of Micro)

    Check Voltage

    on CNS1 pin 5

    With TV

    switched on

    12V? NO

    NO

    Check Voltage

    on CNS2 pin 5

    With TV

    switched on

    Yes

    24V?Yes

    Check Voltage

    on CNS2 pin 10

    With TV

    switched on

    5V? Yes

    NO

    faulty backlight inverter

    Check Fuse F1 (4A250v)

    OK Blown

    Check Voltage

    on CNS1 pin 12

    With TV

    switched on

    0V or

    (pulsing)

    Pulsing

    0V

    faulty PSU

    Suspect CS21,22,28

    R65 Q7 R58 ZD4

    faulty PSU

    Suspect CRS2

    CS19,24,25

    faulty PSU

    Suspect IC1 check

    CS20,23,27

    Over

    Current

    protection