f&p infosmart™ · the average ahi is displayed for the 30-day period. an ahi of less than 5...
TRANSCRIPT
THE F&P InfoSmart™ SOFTWARE:
• Apatientmanagementsystemforall Fisher&PaykelHealthcareCPAPsincluding:
–F&PICON™family –SleepStyle™CPAPswithSmartStick™Technology –SleepStyle™230and600 Series
• Comprehensivepatientreportingthatoffers: –Compliancedatafromfirstuse –Summarizedefficacydataforany30-dayperiod –Detailedefficacydataforany7-dayperiod
• Compatibilitywithmultipledatacommunicationmethods:
–Telephonereporting –SmartStick™ –SerialCable™
F&P InfoSmart™
* Maynotbeavailableforsaleincertaincountries
F&P ICON™
F&PInfoSmart™hasbeendesignedtoworkhandinhandwith
theF&PICON™.TheF&PICON™hasbeendesignedfromthe
outside-intoanswerthestrongcallforacontemporary,compact
CPAPthatblendsseamlesslyintoanybedroomenvironment,
helpingtobreakdownsomeofthetraditionalresistance
associatedwithCPAPtherapy.
InsidetheF&PICON™isacomprehensivesetofintelligent
technologies,integratedintoonestylishsolutiontodelivernew
levelsoftherapy,whileeffectivelymeetingyourbusinessneeds.
REPORTSECTIONS FEATURES
FIXED AUTO
SLEEPSTYLE™ CPAP MODEL 244*
F&P ICON™ PREMO*
SLEEPSTYLE™ CPAP MODEL 254*
F&P ICON™ AUTO*
F&P InfoSmart™ Software Data Reporting
1:SummaryData
2:TreatmentProfile Summary
3:ComplianceSummary
SLEEPSTYLE™ CPAP MODELS 242* / 230 / 600
F&P ICON™ NOVO*
ComplianceStatistics
EfficacyStatistics
SensAwake™Statistics
ComplianceMetric
AHIProfile
PressureProfile
SystemLeakProfile
UsageandHumidityProfile
CPAPPatternsofUse
SensAwake™Statistics
HypopneaStatistics
ApneaStatistics
FlowLimitationStatistics
PressureProfile
SystemLeakProfile
RunTime
ComplianceData
EfficacyData
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
5:TreatmentTable Summary
4:DetailedProfile
More insights. More results.
F&PInfoSmart™SOFTWAREORDERCODE:900ICON100
*APCrunningWindowsXPSP3orlaterisrequiredtorunF&PInfoSmart™.Formoreinformation,pleasecontactyourlocalFisher&PaykelHealthcarerepresentative. InfoSmart™
Version 1.1
www.fphcare.com1850
4537
0 R
EVB
© 2
010
Fish
er &
Pay
kel H
ealt
hcar
e Li
mit
ed
Manufacturer Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348, Panmure, Auckland 1741, New Zealand Tel: +64 9 574 0100 Fax: +64 9 574 0158 Email: [email protected] Web: www.fphcare.com Australia Tel: +61 3 9879 5022 Fax: +61 3 9879 5232 Austria Tel: 0800 29 31 23 Fax: 0800 29 31 22 Benelux Tel: +31 40 216 3555 Fax: +31 40 216 3554 China Tel: +86 20 3205 3486 Fax: +86 20 3205 2132 France Tel: +33 1 6446 5201 Fax: +33 1 6446 5221 Germany Tel: +49 7181 98599 0 Fax: +49 7181 98599 66 India Tel: +91 80 4284 4000 Fax: +91 80 4123 6044 Irish Republic Tel: 1800 409 011Italy Tel: +39 06 7839 2939 Fax: +39 06 7814 7709 Japan Tel: +81 3 3661 7205 Fax: +81 3 3661 7206 Northern Ireland Tel: +0800 132 189 Spain Tel: +34 902 013 346 Fax: +34 902 013 379 Sweden Tel: +46 8 564 76 680 Fax: +46 8 36 63 10 Switzerland Tel: 0800 83 47 63 Fax: 0800 83 47 54 Taiwan Tel: +886 2 8751 1739 Fax: +886 2 8751 5625 Turkey Tel: +90 312 354 34 12 Fax: +90 312 354 31 01 UK (EU Authorised Representative) Fisher & Paykel Healthcare Ltd, Unit 16, Cordwallis Park, Clivemont Road, Maidenhead,BerkshireSL6 7BU,UKTel:+44 1628 626 136Fax:+44 1628 626 146 USA Tel: +1 800 446 3908 or +1 949 453 4000 Fax: +1 949 453 4001
Data Communication Tools
Retrievingcompliancedatainatimelyand
efficientmanneriscrucialtobusinesssuccess
aswellasimprovingpatientoutcomes.
Fisher&PaykelHealthcareprovidesthe
followingdatacommunicationtools:
• Telephonereporting:thepatientcanrelaysleepdatafromthe
Displayscreenofthedevice,whichcanthenbeverifiedusing
F&PInfoSmart™.
• SmartStick™:utilizinggenericUSBtechnologywhichprovides
largedatastoragecapacity.Thepatientcanmailthe
SmartStick™toyoufordownloaddirecttoF&PInfoSmart™.
• SerialCable:theCPAPdevicecanbeconnectedtoa
computerusingaSerialCable.
Data Reporting
Treatmentcomplianceandefficacyreportingisakeyfactorforcomprehensivepatientfollow-upandthustherapyoutcomes.F&PInfoSmart™Softwareproducescomprehensivechartingandreportingofpatientdataincluding:
– 30daysofsummarydata– 7daysofdetaileddata–Cumulativesummarydatafromfirstuse
Thereportsaredividedintofivesections(refertotableonback). Thefirstfoursectionsofthereportaredetailedasfollows.
SECTION 1: Summary Data The Summary Data report displays
cumulative summary data from
first use, as well as summary data
for a 30-day period.
F&P InfoSmart™ | FEATURES
SECTION 4: Detailed ProfileThe Detailed Profile displays
comprehensive data for the last
seven days within the selected
30-day date range. The information
displayed depends on the
CPAP model, but can include
SensAwake™, hypopnea, apnea
and flow limited events, pressure,
system leak and run time.
SECTION 3: Compliance SummaryThe Compliance Summary displays
patterns of CPAP use for 30
consecutive days.
SECTION 2:Treatment Profile SummaryThe Treatment Profile Summary
displays data for any 30
consecutive days and includes
summarized information on usage
and efficacy data.
AHI Profile
TheAHIisdisplayedforeachnightoftheselected30-dayperiod.Aneffectivetreatmentindicatorof5isalsoshownonthereport.
Pressure Profile
Theaverageand90thpercentilepressurevaluesaredisplayedforeachnight.Prescriptionpressuresareindicated bythehorizontalblacklines.
System Leak Profile
Theaverageand90thpercentileleakvaluesaredisplayedforeachnight.
Usage and Humidity Profile
CPAPusageandhumiditysettingaredisplayedforeachnight.
Events
SensAwake™activations,hypopnea,apneaandflowlimitedeventsareidentifiedforeachnight.AnAHIisalsodisplayed.
CPAP Patterns of Use
PatternsofCPAPuseareestablished,helpingtotrackpatientsleephygiene.
Pressure Profile
ThePressureProfiledemonstratesthepressurevariationsthroughouteachnight(includingminimumandmaximumpressures).Prescriptionpressuresareindicatedbythehorizontalblacklines.
Run Time
CPAPusageandhumiditysettingaredisplayedforeachnight.
F&P InfoSmart™ | REPORTS
Efficacy Statistics
TheaverageAHIisdisplayedforthe 30-dayperiod.AnAHIoflessthan5indicateseffectivetreatmentbutifitis5ormorethisrequiresfurtherinvestigationintothedetaileddatatoidentifythecause.Theaveragesystemleakisdisplayedforthe30-dayperiodinlitersperminute.Theleakiscomprisedofmaskleak,biasflowandmouthleak.
Compliance Statistics
Thisdisplaysthe30-dayperiodselectedbytheclinician.Itshowsthenumber ofdaysthatthedevicehasbeenused for≥ 4hours.Anumberlessthan21daysduringa30-dayperiodwouldalertyouto≤ 70%compliance.
Compliance Metric
Thecompliancemetricprovidesanautomaticcalculationofpatientcompliance,designedtomeetthe UnitedStates’CMSguidelines.ThecompliancemetricdetailsthenumberofdaysinthereportingperiodthatthepatientusedtheCPAPfor≥ 4hoursandthepercentageofnightsthatthepatientusedthedevicefor≥ 4hours.
F&PInfoSmart™isadvancedpatientmanagementsoftwarethatiscompatiblewithall
Fisher&PaykelHealthcareCPAPdevices.Trackingpatientprogressisvitalforbusinesssuccessand
F&PInfoSmart™providesaplatformforproactivelymonitoringpatientcompliance.
F&P InfoSmart™ offers more insights into a patient’s treatment while delivering more results.
System Leak Profile
The System Leak Profile demonstrates the leak levels throughout each night.