f&p infosmart™ · the average ahi is displayed for the 30-day period. an ahi of less than 5...

2
THE F&P InfoSmart SOFTWARE: A patient management system for all Fisher & Paykel Healthcare CPAPs including: – F&P ICON™ family – SleepStyle™ CPAPs with SmartStick™ Technology – SleepStyle™ 230 and 600 Series Comprehensive patient reporting that offers: – Compliance data from first use – Summarized efficacy data for any 30-day period – Detailed efficacy data for any 7-day period Compatibility with multiple data communication methods: – Telephone reporting – SmartStick™ – Serial Cable™ F&P InfoSmart™ * May not be available for sale in certain countries F&P ICON™ F&P InfoSmart™ has been designed to work hand in hand with the F&P ICON™. The F&P ICON™ has been designed from the outside-in to answer the strong call for a contemporary, compact CPAP that blends seamlessly into any bedroom environment, helping to break down some of the traditional resistance associated with CPAP therapy. Inside the F&P ICON™ is a comprehensive set of intelligent technologies, integrated into one stylish solution to deliver new levels of therapy, while effectively meeting your business needs. REPORT SECTIONS FEATURES FIXED AUTO SLEEPSTYLE™ CPAP MODEL 244* F&P ICON™ PREMO* SLEEPSTYLE™ CPAP MODEL 254* F&P ICON™ AUTO* F&P InfoSmart™ Software Data Reporting 1: Summary Data 2: Treatment Profile Summary 3: Compliance Summary SLEEPSTYLE™ CPAP MODELS 242* / 230 / 600 F&P ICON™ NOVO* Compliance Statistics Efficacy Statistics SensAwake™ Statistics Compliance Metric AHI Profile Pressure Profile System Leak Profile Usage and Humidity Profile CPAP Patterns of Use SensAwake™ Statistics Hypopnea Statistics Apnea Statistics Flow Limitation Statistics Pressure Profile System Leak Profile Run Time Compliance Data Efficacy Data 5: Treatment Table Summary 4: Detailed Profile More insights. More results. F&P InfoSmart™ SOFTWARE ORDER CODE: 900ICON100 * A PC running Windows XP SP3 or later is required to run F&P InfoSmart™. For more information, please contact your local Fisher & Paykel Healthcare representative. InfoSmart Version 1.1 www.fphcare.com 185045370 REVB © 2010 Fisher & Paykel Healthcare Limited Manufacturer Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348, Panmure, Auckland 1741, New Zealand Tel: +64 9 574 0100 Fax: +64 9 574 0158 Email: [email protected] Web: www.fphcare.com Australia Tel: +61 3 9879 5022 Fax: +61 3 9879 5232 Austria Tel: 0800 29 31 23 Fax: 0800 29 31 22 Benelux Tel: +31 40 216 3555 Fax: +31 40 216 3554 China Tel: +86 20 3205 3486 Fax: +86 20 3205 2132 France Tel: +33 1 6446 5201 Fax: +33 1 6446 5221 Germany Tel: +49 7181 98599 0 Fax: +49 7181 98599 66 India Tel: +91 80 4284 4000 Fax: +91 80 4123 6044 Irish Republic Tel: 1800 409 011 Italy Tel: +39 06 7839 2939 Fax: +39 06 7814 7709 Japan Tel: +81 3 3661 7205 Fax: +81 3 3661 7206 Northern Ireland Tel: +0800 132 189 Spain Tel: +34 902 013 346 Fax: +34 902 013 379 Sweden Tel: +46 8 564 76 680 Fax: +46 8 36 63 10 Switzerland Tel: 0800 83 47 63 Fax: 0800 83 47 54 Taiwan Tel: +886 2 8751 1739 Fax: +886 2 8751 5625 Turkey Tel: +90 312 354 34 12 Fax: +90 312 354 31 01 UK (EU Authorised Representative) Fisher & Paykel Healthcare Ltd, Unit 16, Cordwallis Park, Clivemont Road, Maidenhead, Berkshire SL6 7BU, UK Tel: +44 1628 626 136 Fax: +44 1628 626 146 USA Tel: +1 800 446 3908 or +1 949 453 4000 Fax: +1 949 453 4001

Upload: others

Post on 06-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: F&P InfoSmart™ · The average AHI is displayed for the 30-day period. An AHI of less than 5 indicates effective treatment but if it is 5 or more this requires further investigation

THE F&P InfoSmart™ SOFTWARE:

• Apatientmanagementsystemforall Fisher&PaykelHealthcareCPAPsincluding:

–F&PICON™family –SleepStyle™CPAPswithSmartStick™Technology –SleepStyle™230and600 Series

• Comprehensivepatientreportingthatoffers: –Compliancedatafromfirstuse –Summarizedefficacydataforany30-dayperiod –Detailedefficacydataforany7-dayperiod

• Compatibilitywithmultipledatacommunicationmethods:

–Telephonereporting –SmartStick™ –SerialCable™

F&P InfoSmart™

* Maynotbeavailableforsaleincertaincountries

F&P ICON™

F&PInfoSmart™hasbeendesignedtoworkhandinhandwith

theF&PICON™.TheF&PICON™hasbeendesignedfromthe

outside-intoanswerthestrongcallforacontemporary,compact

CPAPthatblendsseamlesslyintoanybedroomenvironment,

helpingtobreakdownsomeofthetraditionalresistance

associatedwithCPAPtherapy.

InsidetheF&PICON™isacomprehensivesetofintelligent

technologies,integratedintoonestylishsolutiontodelivernew

levelsoftherapy,whileeffectivelymeetingyourbusinessneeds.

REPORTSECTIONS FEATURES

FIXED AUTO

SLEEPSTYLE™ CPAP MODEL 244*

F&P ICON™ PREMO*

SLEEPSTYLE™ CPAP MODEL 254*

F&P ICON™ AUTO*

F&P InfoSmart™ Software Data Reporting

1:SummaryData

2:TreatmentProfile Summary

3:ComplianceSummary

SLEEPSTYLE™ CPAP MODELS 242* / 230 / 600

F&P ICON™ NOVO*

ComplianceStatistics

EfficacyStatistics

SensAwake™Statistics

ComplianceMetric

AHIProfile

PressureProfile

SystemLeakProfile

UsageandHumidityProfile

CPAPPatternsofUse

SensAwake™Statistics

HypopneaStatistics

ApneaStatistics

FlowLimitationStatistics

PressureProfile

SystemLeakProfile

RunTime

ComplianceData

EfficacyData

5:TreatmentTable Summary

4:DetailedProfile

More insights. More results.

F&PInfoSmart™SOFTWAREORDERCODE:900ICON100

*APCrunningWindowsXPSP3orlaterisrequiredtorunF&PInfoSmart™.Formoreinformation,pleasecontactyourlocalFisher&PaykelHealthcarerepresentative. InfoSmart™

Version 1.1

www.fphcare.com1850

4537

0 R

EVB

© 2

010

Fish

er &

Pay

kel H

ealt

hcar

e Li

mit

ed

Manufacturer Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348, Panmure, Auckland 1741, New Zealand Tel: +64 9 574 0100 Fax: +64 9 574 0158 Email: [email protected] Web: www.fphcare.com Australia Tel: +61 3 9879 5022 Fax: +61 3 9879 5232 Austria Tel: 0800 29 31 23 Fax: 0800 29 31 22 Benelux Tel: +31 40 216 3555 Fax: +31 40 216 3554 China Tel: +86 20 3205 3486 Fax: +86 20 3205 2132 France Tel: +33 1 6446 5201 Fax: +33 1 6446 5221 Germany Tel: +49 7181 98599 0 Fax: +49 7181 98599 66 India Tel: +91 80 4284 4000 Fax: +91 80 4123 6044 Irish Republic Tel: 1800 409 011Italy Tel: +39 06 7839 2939 Fax: +39 06 7814 7709 Japan Tel: +81 3 3661 7205 Fax: +81 3 3661 7206 Northern Ireland Tel: +0800 132 189 Spain Tel: +34 902 013 346 Fax: +34 902 013 379 Sweden Tel: +46 8 564 76 680 Fax: +46 8 36 63 10 Switzerland Tel: 0800 83 47 63 Fax: 0800 83 47 54 Taiwan Tel: +886 2 8751 1739 Fax: +886 2 8751 5625 Turkey Tel: +90 312 354 34 12 Fax: +90 312 354 31 01 UK (EU Authorised Representative) Fisher & Paykel Healthcare Ltd, Unit 16, Cordwallis Park, Clivemont Road, Maidenhead,BerkshireSL6 7BU,UKTel:+44 1628 626 136Fax:+44 1628 626 146 USA Tel: +1 800 446 3908 or +1 949 453 4000 Fax: +1 949 453 4001

Page 2: F&P InfoSmart™ · The average AHI is displayed for the 30-day period. An AHI of less than 5 indicates effective treatment but if it is 5 or more this requires further investigation

Data Communication Tools

Retrievingcompliancedatainatimelyand

efficientmanneriscrucialtobusinesssuccess

aswellasimprovingpatientoutcomes.

Fisher&PaykelHealthcareprovidesthe

followingdatacommunicationtools:

• Telephonereporting:thepatientcanrelaysleepdatafromthe

Displayscreenofthedevice,whichcanthenbeverifiedusing

F&PInfoSmart™.

• SmartStick™:utilizinggenericUSBtechnologywhichprovides

largedatastoragecapacity.Thepatientcanmailthe

SmartStick™toyoufordownloaddirecttoF&PInfoSmart™.

• SerialCable:theCPAPdevicecanbeconnectedtoa

computerusingaSerialCable.

Data Reporting

Treatmentcomplianceandefficacyreportingisakeyfactorforcomprehensivepatientfollow-upandthustherapyoutcomes.F&PInfoSmart™Softwareproducescomprehensivechartingandreportingofpatientdataincluding:

– 30daysofsummarydata– 7daysofdetaileddata–Cumulativesummarydatafromfirstuse

Thereportsaredividedintofivesections(refertotableonback). Thefirstfoursectionsofthereportaredetailedasfollows.

SECTION 1: Summary Data The Summary Data report displays

cumulative summary data from

first use, as well as summary data

for a 30-day period.

F&P InfoSmart™ | FEATURES

SECTION 4: Detailed ProfileThe Detailed Profile displays

comprehensive data for the last

seven days within the selected

30-day date range. The information

displayed depends on the

CPAP model, but can include

SensAwake™, hypopnea, apnea

and flow limited events, pressure,

system leak and run time.

SECTION 3: Compliance SummaryThe Compliance Summary displays

patterns of CPAP use for 30

consecutive days.

SECTION 2:Treatment Profile SummaryThe Treatment Profile Summary

displays data for any 30

consecutive days and includes

summarized information on usage

and efficacy data.

AHI Profile

TheAHIisdisplayedforeachnightoftheselected30-dayperiod.Aneffectivetreatmentindicatorof5isalsoshownonthereport.

Pressure Profile

Theaverageand90thpercentilepressurevaluesaredisplayedforeachnight.Prescriptionpressuresareindicated bythehorizontalblacklines.

System Leak Profile

Theaverageand90thpercentileleakvaluesaredisplayedforeachnight.

Usage and Humidity Profile

CPAPusageandhumiditysettingaredisplayedforeachnight.

Events

SensAwake™activations,hypopnea,apneaandflowlimitedeventsareidentifiedforeachnight.AnAHIisalsodisplayed.

CPAP Patterns of Use

PatternsofCPAPuseareestablished,helpingtotrackpatientsleephygiene.

Pressure Profile

ThePressureProfiledemonstratesthepressurevariationsthroughouteachnight(includingminimumandmaximumpressures).Prescriptionpressuresareindicatedbythehorizontalblacklines.

Run Time

CPAPusageandhumiditysettingaredisplayedforeachnight.

F&P InfoSmart™ | REPORTS

Efficacy Statistics

TheaverageAHIisdisplayedforthe 30-dayperiod.AnAHIoflessthan5indicateseffectivetreatmentbutifitis5ormorethisrequiresfurtherinvestigationintothedetaileddatatoidentifythecause.Theaveragesystemleakisdisplayedforthe30-dayperiodinlitersperminute.Theleakiscomprisedofmaskleak,biasflowandmouthleak.

Compliance Statistics

Thisdisplaysthe30-dayperiodselectedbytheclinician.Itshowsthenumber ofdaysthatthedevicehasbeenused for≥ 4hours.Anumberlessthan21daysduringa30-dayperiodwouldalertyouto≤ 70%compliance.

Compliance Metric

Thecompliancemetricprovidesanautomaticcalculationofpatientcompliance,designedtomeetthe UnitedStates’CMSguidelines.ThecompliancemetricdetailsthenumberofdaysinthereportingperiodthatthepatientusedtheCPAPfor≥ 4hoursandthepercentageofnightsthatthepatientusedthedevicefor≥ 4hours.

F&PInfoSmart™isadvancedpatientmanagementsoftwarethatiscompatiblewithall

Fisher&PaykelHealthcareCPAPdevices.Trackingpatientprogressisvitalforbusinesssuccessand

F&PInfoSmart™providesaplatformforproactivelymonitoringpatientcompliance.

F&P InfoSmart™ offers more insights into a patient’s treatment while delivering more results.

System Leak Profile

The System Leak Profile demonstrates the leak levels throughout each night.