Series®

and-Held Terminal

les A and Bak L0122EV, Revision D

e Operating Guide

summarizes the menus used for , and configuring I/A Series and-Held Terminal (HHT) having

EV, Revision D.

MI020-400January 1997

NG THIS LINE

CU

TH

ER

E

I/AModel HHT H

StyWith Program P

Referenc

This Operating Guideoperating, calibratingTransmitters using HProgram Pak L0122

Copyright 1990 - 1997by The Foxboro CompanyAll rights reserved

Instruction

ISSUE DATES MAY 1990 AUG 1991 MAY 1993 JUN 1994 JUL 1995 JAN 1997

Foxboro and I/A Series are registered trademarks of the Foxboro Company.Siebe is a registered trademark of Siebe, plc.

MB 100 Printed in U.S.A. 0197

FOLDFOLD

CUT ALOCUT ALONG THIS LINE

CU

TH

ER

E

DIAGNOSTIC ERROR CODE SUMMARY

DISPLAYED CODE DESCRIPTION OR SUGGESTED ACTION

Pressure Transmitters (820/860 and I/A Series):

02, 04, 0B, 0D, 0E Turn off transmitter power. If error continues when power is turned on, contact Foxboro.

0A, 03, 2F Check configuration. Change as required. If error continues, contact Foxboro.

07, 0C, 20, 21, 22, 25, 26, 29

Sensor or Electronics Failure. Contact Foxboro.

Magnetic Flowmeters:

02, 0C, 0D, 10, 11, 1B, 30

Contact Foxboro. Refer to MI 021-384.

12, 14 Check Coil Wiring and Configuration.

13 Check Multi-conductor Wiring; Clean Electrodes.

20 Low Flow. Reverse Flow.

21, 22 High Flow or Configuration.

31 Use transmitter pushbuttons and re-enter data.

32 Use HHT and re-enter data.

Mass Flowmeters:

2, 3, 13, 1F4, 1F5, 1F6, 1F7

Contact Foxboro Repair.

258, 259, 25A, 25B Measurements are invalid. Provide warmer climate for transmitter.

320, 321, 322, 323 2BC

Measurements are invalid. Check RTD.Measurements are invalid. Check Process.

2BD Transmitter is off-line. Contact Foxboro.

324, 388, 389 Mass flow is too high.

384 Process temperature is too low or RTD is miswired.

385 Process temperature is too high or RTD is miswired.

386 Process density is too low or Tube Parameter.

387 Process density is too high or Tube Parameter.

388,389 Flow exceeds calibration limit. Adjust process or calibration limit.

DIAGNOSTIC ERROR CODE SUMMARY

DISPLAYED CODE DESCRIPTION OR SUGGESTED ACTION

Vortex Meters:

02 ROM checksum error. Replace electronics.

03 EEPROM checksum error. Change database, replace transmitter.

04 RAM error. Install new module.

0A Math error. Correct problems, replace amplifier.

0C Sensor electrical failure. Replace sensor.

0E Core failure. Replace electronics.

20 Vortex frequency high. Check sensor.

21 Xmtr Temp High. Check sensor.

25 Xmtr Temp Low. Check sensor.

2F Off-line Config w/error. Replace electronics.

32 Bad database cfg. Download correct database.

Temperature Transmitters

2n Bad Sensor #1

4n Bad Sensor #2

6n Bad Sensor #1 and #2

8n Standards fail. Replace electronics module.

An Combination of 2n and 8n

Cn Combination of 4n and 8n.

En Combination of 2n, 4n, and 8n.

Page 2: Foxboro Handheld Terminal HHT-AAEFNB

MENU LEVELHHT COMMUNICATION MODE:T = TransmitterD = DemonstrationM = Memory Pak

1T Off Cal SetupMeas Test HHT mP

OUTPUT MODE: 4 TO 20 mA = m

Digital = dBoth = b

ANSMITTER TYPE: Pressure = P

Temperature = TMagnetic Flow = M

ss Flow (Coriolis) = CVortex = V

PLOADS/DOWNLOADS

1

2

3

4

5

6 7

UNCTIONS THAT READFROM XMTR

RAM

MEMPAK

FG-CONFIG (SAVE ON EXIT)PAK - SAVETOPAK - USERDATA

REP - RESTOREPAKFILEAK - FILEXFER - PC_TO_HHTAK - FILEXFER - HHT_TO_PC

PAK - PRECFGPAK - RDFILE

PAK - SAVETOPAK - SAVEALLTOPAK

OF MENU CODES

G THIS LINE

ME

NU

SU

MM

AR

Y

CA

LIB

RA

TE

TRA

NS

MIT

TE

R

ON

ME

NU

LE

VE

L 1

ME

NU

LE

VE

L 2

ME

NU

LE

VE

L 3

CO

NF

IGU

RE

TRA

NS

MIT

TE

RM

EA

SU

RE

ME

NT

TES

T L

OO

P A

ND

TRA

NS

MIT

TE

RS

ET

HH

T

Ca

lS

etup

Mea

sTe

stH

HT

Ch

gCfg

Mem

Pak

Fie

ldR

epC

lk

Tra

nD

em

o

Re

set

Up

date

Con

figP

reC

fgR

dFile

WrT

ran

Dir

ErP

kTag

Me

mC

opy

Re

sto

reP

akF

ile

C =

Cha

nge

P =

Pre

vio

usN

= N

ext

E =

End

Con

vert

ME

NU

LE

VE

L 4

File

Xfe

r

HH

T_t

o_P

C

PC

_to

_HH

T

Sav

eTo

Pak

Use

r D

ata

Sav

eAllT

oPak

Ze

roTo

tal

Def

aul

t

Tran

cal

Zer

oR

eR

ange

MaC

al

Xm

trP

ar

Sel

ftes

t

Loop

Cal

Sta

tus

Ser

ialN

o

Fre

quen

cy

TRANSMITTER

TR

Ma

DATA U*F

PC10

XMTR

*1 = SETUP - CHGC2 = SETUP - MEM

3 = SETUP - FIELD4 = SETUP- MEMP5 = SETUP- MEMP6 = SETUP - MEM7 = SETUP - MEM

SETUP - MEM

SUMMARY

Grp

Dis

p

Off

Re

con

nect

Pul

seP

rese

t

Em

ptyP

ipeD

ete

ct

Me

as

CUT ALONCUT ALONG THIS LINE