foxboro handheld terminal hht-aaefnb
TRANSCRIPT
Series®
and-Held Terminal
les A and Bak L0122EV, Revision D
e Operating Guide
summarizes the menus used for , and configuring I/A Series and-Held Terminal (HHT) having
EV, Revision D.
MI020-400January 1997
NG THIS LINE
CU
TH
ER
E
I/AModel HHT H
StyWith Program P
Referenc
This Operating Guideoperating, calibratingTransmitters using HProgram Pak L0122
Copyright 1990 - 1997by The Foxboro CompanyAll rights reserved
Instruction
ISSUE DATES MAY 1990 AUG 1991 MAY 1993 JUN 1994 JUL 1995 JAN 1997
Foxboro and I/A Series are registered trademarks of the Foxboro Company.Siebe is a registered trademark of Siebe, plc.
MB 100 Printed in U.S.A. 0197
FOLDFOLD
CUT ALOCUT ALONG THIS LINE
CU
TH
ER
E
DIAGNOSTIC ERROR CODE SUMMARY
DISPLAYED CODE DESCRIPTION OR SUGGESTED ACTION
Pressure Transmitters (820/860 and I/A Series):
02, 04, 0B, 0D, 0E Turn off transmitter power. If error continues when power is turned on, contact Foxboro.
0A, 03, 2F Check configuration. Change as required. If error continues, contact Foxboro.
07, 0C, 20, 21, 22, 25, 26, 29
Sensor or Electronics Failure. Contact Foxboro.
Magnetic Flowmeters:
02, 0C, 0D, 10, 11, 1B, 30
Contact Foxboro. Refer to MI 021-384.
12, 14 Check Coil Wiring and Configuration.
13 Check Multi-conductor Wiring; Clean Electrodes.
20 Low Flow. Reverse Flow.
21, 22 High Flow or Configuration.
31 Use transmitter pushbuttons and re-enter data.
32 Use HHT and re-enter data.
Mass Flowmeters:
2, 3, 13, 1F4, 1F5, 1F6, 1F7
Contact Foxboro Repair.
258, 259, 25A, 25B Measurements are invalid. Provide warmer climate for transmitter.
320, 321, 322, 323 2BC
Measurements are invalid. Check RTD.Measurements are invalid. Check Process.
2BD Transmitter is off-line. Contact Foxboro.
324, 388, 389 Mass flow is too high.
384 Process temperature is too low or RTD is miswired.
385 Process temperature is too high or RTD is miswired.
386 Process density is too low or Tube Parameter.
387 Process density is too high or Tube Parameter.
388,389 Flow exceeds calibration limit. Adjust process or calibration limit.
DIAGNOSTIC ERROR CODE SUMMARY
DISPLAYED CODE DESCRIPTION OR SUGGESTED ACTION
Vortex Meters:
02 ROM checksum error. Replace electronics.
03 EEPROM checksum error. Change database, replace transmitter.
04 RAM error. Install new module.
0A Math error. Correct problems, replace amplifier.
0C Sensor electrical failure. Replace sensor.
0E Core failure. Replace electronics.
20 Vortex frequency high. Check sensor.
21 Xmtr Temp High. Check sensor.
25 Xmtr Temp Low. Check sensor.
2F Off-line Config w/error. Replace electronics.
32 Bad database cfg. Download correct database.
Temperature Transmitters
2n Bad Sensor #1
4n Bad Sensor #2
6n Bad Sensor #1 and #2
8n Standards fail. Replace electronics module.
An Combination of 2n and 8n
Cn Combination of 4n and 8n.
En Combination of 2n, 4n, and 8n.
MENU LEVELHHT COMMUNICATION MODE:T = TransmitterD = DemonstrationM = Memory Pak
1T Off Cal SetupMeas Test HHT mP
OUTPUT MODE: 4 TO 20 mA = m
Digital = dBoth = b
ANSMITTER TYPE: Pressure = P
Temperature = TMagnetic Flow = M
ss Flow (Coriolis) = CVortex = V
PLOADS/DOWNLOADS
1
2
3
4
5
6 7
UNCTIONS THAT READFROM XMTR
RAM
MEMPAK
FG-CONFIG (SAVE ON EXIT)PAK - SAVETOPAK - USERDATA
REP - RESTOREPAKFILEAK - FILEXFER - PC_TO_HHTAK - FILEXFER - HHT_TO_PC
PAK - PRECFGPAK - RDFILE
PAK - SAVETOPAK - SAVEALLTOPAK
OF MENU CODES
G THIS LINE
ME
NU
SU
MM
AR
Y
CA
LIB
RA
TE
TRA
NS
MIT
TE
R
ON
ME
NU
LE
VE
L 1
ME
NU
LE
VE
L 2
ME
NU
LE
VE
L 3
CO
NF
IGU
RE
TRA
NS
MIT
TE
RM
EA
SU
RE
ME
NT
TES
T L
OO
P A
ND
TRA
NS
MIT
TE
RS
ET
HH
T
Ca
lS
etup
Mea
sTe
stH
HT
Ch
gCfg
Mem
Pak
Fie
ldR
epC
lk
Tra
nD
em
o
Re
set
Up
date
Con
figP
reC
fgR
dFile
WrT
ran
Dir
ErP
kTag
Me
mC
opy
Re
sto
reP
akF
ile
C =
Cha
nge
P =
Pre
vio
usN
= N
ext
E =
End
Con
vert
ME
NU
LE
VE
L 4
File
Xfe
r
HH
T_t
o_P
C
PC
_to
_HH
T
Sav
eTo
Pak
Use
r D
ata
Sav
eAllT
oPak
Ze
roTo
tal
Def
aul
t
Tran
cal
Zer
oR
eR
ange
MaC
al
Xm
trP
ar
Sel
ftes
t
Loop
Cal
Sta
tus
Ser
ialN
o
Fre
quen
cy
TRANSMITTER
TR
Ma
DATA U*F
PC10
XMTR
*1 = SETUP - CHGC2 = SETUP - MEM
3 = SETUP - FIELD4 = SETUP- MEMP5 = SETUP- MEMP6 = SETUP - MEM7 = SETUP - MEM
SETUP - MEM
SUMMARY
Grp
Dis
p
Off
Re
con
nect
Pul
seP
rese
t
Em
ptyP
ipeD
ete
ct
Me
as
CUT ALONCUT ALONG THIS LINE