fortis advantage tds en 2009-08-24 estonia 2

2
2009-08-24 Page 1 of 2 Fortis Advantage System Technical Data Sheet Description The Fortis™ Advantage Bulk System of sensitised pumped emulsion blends has been designed for use in wet blasting applications. Application Fortis™ Advantage has been specifically tailored for use in open cut hard rock mining. Fortis™ Advantage can be used whenever wet blast holes are encountered. It is not suitable for ground containing reactive sulphide. Key Benefits Fortis™ Advantage is reliable in dry and wet blastholes. The integrated product and delivery systems of the Fortis™ Advantage Bulk System ensures accuracy, productivity and dependability of supply. Fortis™ Advantage is only sensitized in the borehole by chemical gassing. Fortis™ Advantage can be loaded at varying energies and densities to maximise fragmentation and improve mine to mill productivity. Fortis™ Advantage provides fully coupled explosive charges to maximise blasting outcomes. Recommendations for Use Blasthole Charge Length Fortis™ Advantage is suitable for use in holes of up to 30 m in length, depending on hole diameter, product density and presence of water. Please contact your local Orica representative for further information. Priming and Initiation Fortis™ Advantage must be in direct contact with an appropriately sized Senatel™ packaged explosive or Pentex™ booster. The use of detonating cord may adversely affect the performance of the Fortis™ Advantage series and could result in misfires. Consult an Orica Technical Representative before attempting to use with detonating cord. Charging Fortis™ Advantage is part of the range of bulk explosives delivered by Orica's Mobile Manufacturing Units (MMU™). Fortis™ Advantage is manufactured on the MMU™ and pumped into blastholes on demand. Gassing Time Allow at least 30 minutes between loading and stemming blastholes. Technical Properties Fortis Advantage Product 100 70 Density (g/cm 3 ) (1) 1.10 –1.20 1.05 – 1.15 Minimum Blasthole Diameter (mm) (2) 65 65 Maximum Blasthole Depth (m) 30 30 Maximum Charge Length (m) 25 25 Hole Type Dry, wet or dewatered Delivery System Pumped Typical VOD (km/s) (3) 4.0 – 5.0 3.5 – 4.5 Relative Effective Energy (REE) (4) Relative Weight Strength (%) 86 92 Relative Bulk Strength (%) 112 115 CO2 Output (kg/t) (5) 124 154 Sleep Time (d) 3 3 Sleep-Time within Blastholes Sleep time is dependent on factors such as hole diameter, density, ground water conditions and initiation system. Orica Mining Services Technical Personnel should be consulted if special conditions exist. Ground Temperature These products are available for use in ground temperatures -30 °C to a maximum of 50 °C. If your application requires you to operate outside this temperature range please contact your local Orica representative. Storage and Handling Product Classification Authorised Name: Fortis™ Advantage 70 Proper Shipping Name: Explosive, Blasting Type E UN No.: 0241 Classification: 1.1D EC Type Certificate: 0589.EXP.1650/08 Authorised Name: Fortis™ Advantage 100 Proper Shipping Name: Explosive, Blasting Type E UN No.: 0241 Classification: 1.1D EC Type Certificate: 0589.EXP.1653/08 All regulations pertaining to the handling and use of such explosives apply.

Upload: dinoyancachajlla

Post on 23-Dec-2015

218 views

Category:

Documents


4 download

DESCRIPTION

Catalogo

TRANSCRIPT

Page 1: Fortis Advantage TDS en 2009-08-24 Estonia 2

2009-08-24 Page 1 of 2

Fortis ™ Advantage System

Technical Data Sheet

Description The Fortis™ Advantage Bulk System of sensitised pumped emulsion blends has been designed for use in wet blasting applications. Application Fortis™ Advantage has been specifically tailored for use in open cut hard rock mining. Fortis™ Advantage can be used whenever wet blast holes are encountered. It is not suitable for ground containing reactive sulphide. Key Benefits • Fortis™ Advantage is reliable in dry and wet blastholes. • The integrated product and delivery systems of the

Fortis™ Advantage Bulk System ensures accuracy, productivity and dependability of supply.

• Fortis™ Advantage is only sensitized in the borehole by chemical gassing.

• Fortis™ Advantage can be loaded at varying energies and densities to maximise fragmentation and improve mine to mill productivity.

• Fortis™ Advantage provides fully coupled explosive charges to maximise blasting outcomes.

Recommendations for Use Blasthole Charge Length Fortis™ Advantage is suitable for use in holes of up to 30 m in length, depending on hole diameter, product density and presence of water. Please contact your local Orica representative for further information. Priming and Initiation Fortis™ Advantage must be in direct contact with an appropriately sized Senatel™ packaged explosive or Pentex™ booster. The use of detonating cord may adversely affect the performance of the Fortis™ Advantage series and could result in misfires. Consult an Orica Technical Representative before attempting to use with detonating cord. Charging Fortis™ Advantage is part of the range of bulk explosives delivered by Orica's Mobile Manufacturing Units (MMU™). Fortis™ Advantage is manufactured on the MMU™ and pumped into blastholes on demand. Gassing Time Allow at least 30 minutes between loading and stemming blastholes.

Technical Properties

Fortis Advantage Product

100 70

Density (g/cm 3) (1) 1.10 –1.20 1.05 – 1.15

Minimum Blasthole Diameter (mm) (2) 65 65

Maximum Blasthole Depth (m) 30 30

Maximum Charge Length (m) 25 25

Hole Type Dry, wet or dewatered

Delivery System Pumped

Typical VOD (km/s) (3) 4.0 – 5.0 3.5 – 4.5

Relative Effective Energy (REE) (4)

Relative Weight Strength (%) 86 92

Relative Bulk Strength (%) 112 115

CO2 Output (kg/t) (5) 124 154

Sleep Time (d) 3 3

Sleep-Time within Blastholes Sleep time is dependent on factors such as hole diameter, density, ground water conditions and initiation system. Orica Mining Services Technical Personnel should be consulted if special conditions exist. Ground Temperature These products are available for use in ground temperatures -30 °C to a maximum of 50 °C. If your application requires you to operate outside this temperature range please contact your local Orica representative. Storage and Handling Product Classification Authorised Name: Fortis™ Advantage 70 Proper Shipping Name: Explosive, Blasting Type E UN No.: 0241 Classification: 1.1D EC Type Certificate: 0589.EXP.1650/08 Authorised Name: Fortis™ Advantage 100 Proper Shipping Name: Explosive, Blasting Type E UN No.: 0241 Classification: 1.1D EC Type Certificate: 0589.EXP.1653/08 All regulations pertaining to the handling and use of such explosives apply.

Page 2: Fortis Advantage TDS en 2009-08-24 Estonia 2

2009-08-24 Page 2 of 2

Fortis ™ Advantage System

Technical Data Sheet

Disposal Disposal of explosive materials can be hazardous. Methods of safe disposal of explosives may vary depending on the user’s situation. Please contact a local Orica representative for information on safe practices. Safety Fortis™ Advantage is relatively insensitive to accidental initiation by shock, friction or mechanical impact under normal conditions of use. Detonation may occur from heavy impact or excessive heating particularly under conditions of confinement. Explosives based on Ammonium Nitrate such as the Fortis™ Advantage may react with pyritic materials in the ground and create potentially hazardous situations. Orica accepts no responsibility for any loss or liability arising from use of the product in ground containing pyritic or other reactive material. Trademarks

The word Orica, the Ring device and the Orica mark are trademarks

of Orica Group Companies. Senatel™, Pentex™, Fortis™ and

MMU™ are registered trademarks of Orica Explosives Technology

Pty Ltd ACN 075 659 353, 1 Nicholson Street, East Melbourne,

Victoria, Australia. Disclaimer

The manufacturer reserves the right to modify products without prior

notice. All information in this data sheet is believed up-to-date at the

time of publication. Because Orica cannot anticipate or control the

conditions under which this information and its products may be

used, Orica does not take any responsibility for their suitability for

use in any particular application other than liabilities implied

mandatorily by law and which cannot be disclaimed. The user is

expressly responsible to verify the suitability of the information and

the product for use in any particular application. Orica's general

terms and conditions of contract, a copy of which is available upon

request, apply to all sales and are incorporated by reference. Orica Eesti OÜ

Jaama 10

41536 Jõhvi

Estonia

Phone: + 372 33 64 611

Fax: + 372 33 64 620

Email: [email protected] Emergency Telephone Numbers

Within Estonia: 33 64 616

Outside Estonia: + 372 33 64 616

Notes

1. Nominal Density Only.

2. Contact your local Orica Representative for further advice on

loading at minimum hole diameters.

3. VOD will depend on application including explosive density

blasthole diameter and degree of confinement. The VOD range

is based on minimum unconfined and calculated ideal.

4. REE is the Effective Energy relative to ANFO at a density of

0.8 g/cm3. ANFO has an effective energy of 2.30 MJ/kg.

Energies quoted are based on ideal detonation calculations

with a 100 Mpa cut off pressure. Non-ideal detonation energies

are also available on request. These take account of blasthole

diameter, rock type and explosive reaction behaviour.

5. Carbon dioxide is the main greenhouse gas produced. The

output is calculated assuming ideal detonation.