flat top ing - espaciosolar · other isolation products could be used if need it, like polyurethane...

11
PRODUCT DATASHEET DEPLOSUN® FLAT•TOP DOME FLAT TOP PEDESTRIAN

Upload: others

Post on 19-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FLAT TOP ING - EspacioSolar · Other isolation products could be used if need it, like Polyurethane Foam with termal conductivity of 0,023 W/mk 3. CORK RUBBER ISOLATION In order to

P RO DUCT DATASHEET

DEPLOSUN®FLAT•TOP

D O M E

FLAT TOP PEDESTRIAN

Page 2: FLAT TOP ING - EspacioSolar · Other isolation products could be used if need it, like Polyurethane Foam with termal conductivity of 0,023 W/mk 3. CORK RUBBER ISOLATION In order to

Ltd I4

SYSTEM

DEPLOSUN LIGHT PIPES i t's a new sys tem that c aptures day l ight through domes located in the building roofs and transports it many meters inside usinga high reflectivity (98%) aluminium tube. Bring natural l ight to black areas o rooms wi thout windows like bathrooms, basements , offices, industrial bui ldings suchas warehous e, manu fac tu ri ng areas , s u b wa y s tati ons a n d en j oy f ro m th e adv antages o f day l i ghti ng wh e re y ou nev e r ex pec ted t o b e pos s ibl e.

FINAL RESULT is bri ghten i ng areas , ful l o f l ive thank s to s un l i ght. Trans fo rm c ompl ete l y b l ac k areas and reduc e u p to 45%-50% l i ghti ng ene rgyc ons umpti on us ing free and sus tainable natural energy .

DEPLOSUN SYSTEMS f rom ESPACIO SOLAR is a modul ar c onc ept where eac h c us tomer can purc has e a c ompl ete k i t o r i ndependent modul es tobe i n tegrated in thei r own cons truc ti ve l ight pi pe solutions. That means that any l ight pi pe manufac turer could use our Glass .top and F l a t-F o p d o m e sto i n t roduc e g l a s s adv antages in thei r produc ts as a produc t upgrade. Also ou r portfol i o of Di ffusers , c oul d be adap ted to any sys tem.

1. DEPLOSUN FLAT TOP D OM ES WITH DEPLOCELL TECHNOLOGY

Manufac tured in "triple laminated glass" technology with isolation ai r c hamber A Nons l ip treatment in the external tempered side glass will guaranty to passany re g u l a t i o n s i n t h e w o r l d . W a l k t h r o u g h d o m e l e v e l l e d t o r o o f d e c k p re v e n t i n g w a t e r p e n e t ra t i o n , d u e t o s p e c i a l d e s i g n .Patented reflec ti ve "AR w i t h , E 131 - _ - - - - C H N O L O G m a n u f a c t u re d i n h i gh r e f l e ct i v e a l u m in i u m t ha t c a pt u re s and r e di r ec t s sun rays i ns id e the

p i p e i nc r eas ing p e r t o r m a n c e . T h e s pec ia l s h a p e a n d d e s i g n m a x i m i z e s w in t e r p e r f o r m a n c e ( lowes t rays) a n d m i n i m i z e s s u m m e r p e r f o r m a n c e p r o t ec t i ngf rom excess ive heat s troke.

Leak prof i s guaranteed by a s imple but prec ise s y s tem pres ent in the mark et s ince 10 years .

2. REFLECTIVE PIPE DEPLO•DUCT

Due to a superfic ial s i lver t rea tment S ILVER-PLUS 9 8 % ( 98% s uper-refl ec ti v e f a c t o r a s per DIN5036) , they could trans fer sun l ight up to 21 m . Isthe only in the mark et to be a sold reflec tive material and not a l aminated pol y mer sheet, s o we could guaranty a bet te r stabi l i ty to sun ex pos ure duri ngall live o f the tube (25 years guaranty )

3. DIFFUSERS DEPLO-DIF

Del iver c rys tal c l ear and homogeneous day l ight wi th the radi anc e of natural l ight. Selec tive UV rays protec t i on in o rde r to pres erv e ins ide materi al s(furni ture) f rom degradati on. A s imple des ign harmoni z es wi th any dec orati on. Cal l us for spec ial features .

2 P RO DUCT DATASHEEr FLAT-TOP DOME

Page 3: FLAT TOP ING - EspacioSolar · Other isolation products could be used if need it, like Polyurethane Foam with termal conductivity of 0,023 W/mk 3. CORK RUBBER ISOLATION In order to

l ow rays (winter), hi t t i ns i de the al umi num pi pettion angl e caus ing rays to go throught mul tipleching the end of the tube, o f c ours e this dec reas ing

the p i pe, i nc reas i ng u p to doubl i ng p e r f o rm a n c ec ompari ng t o tradi t i onal s un p i pes i n t h e mark e t .

Reflective grid DEPLOCELL is fac tory mounted insideisolation ai r c hamber from the double glazed device,being abs ol utel y p ro tec ted f ro m dus t and s c ratc hIn conventional l i ght pipes domes , l ow rays (winter),they have to go through many reflec tions ins ide thepipe, and dec reas es performanc e.

Patented reflec tive-grid is manufac tured in al uminumSILVER-PLUS 98% wi th a superfic ial s i lver t reatmentup to 98% as pe r DIN5030 , wi th 25 years guaranty .Due to be a sold reflective material , we could guarantya bet te r s tabi l i ty to sun ex pos ure.

W hen instal l ing Deplos un Glass .top, the DEPLOCELL grid should besouth ori ented to max imi z e sun c apture d u ri n g all day .

MORNING

DEPLOSUN domes wi th DEPLOCELL tec hnology redi rec ts sun rays ins idethe pipe reduc ing reflec tions inside, inc reas ing up to doubl ing the amounto f l i g h t c o m p a r i n g w i t h t ra d i t i o n a l s u n p i p e s i n t h e m a r k e t .

• 1 50_V_

• 7 5 '

AFTERNOON

3 P RO DUCT DATASHEEr FLAT•TOP DOME

Page 4: FLAT TOP ING - EspacioSolar · Other isolation products could be used if need it, like Polyurethane Foam with termal conductivity of 0,023 W/mk 3. CORK RUBBER ISOLATION In order to

the only market made double glazed with internal anti -condensation air chamber,nsulation. The hardened ex terior of his face gives him a mechanical ResistanceO r hard plastics.

PLASTICM O NO V AL V E PL AST I C DO M E

It liellovirs, cracks and Icitess mechanicalproperties with the years. Chemicalagents c m accelerate degradationprocess. Only 10 years guaranty

Plastic could be scratch very easilywhen c l eaned or manipulati ng,loosing l ight properti es .

* * * *

Acoustic isolation is very l owbec aus e there is only one plas ticbarrier and continous ai r flow, thatlet s ound c om e in and out.

* *

Monovalve dom e f rom 3 m mthikness wi th ai r fl ow sys tem wil loffer a very l ow thermal insulation.Normal l y up to U=5,4 W/m2-K

GL A SSDE P L O S UN DO M E S

Glass has not aging process, andthei r properties get inal terable foryears .

Glass has a high superfic ialhardness up 6,5 Mohr& Will nev erget sc ratched and Will never looseit's l i ght properti es .

* * * * *

Very high acous ti c isolation dueto a doubl e glazed wi ndow wi thair c ham be r and a 100% sealedsys tem. W e could Reac h up to49 dB s in fl at top model s

DEPLOSUN d o m e wi th doubl eglazed wi ndow, ai r c hamber and100% seal ing sys tem, wil l reac hdown to U=2,6 W /m2-K and ofwe take into c ons iderati on l ightpipe could reac h U=1,9 W1m2-K

2. G L AS S IN F RO NT OF PL AST I C

FLAT-TOP in addi tion of prev ious features we will add mechanical load res is tance. DEPLOSUN FLAT-TOPis the only l ight pi pe to of fer a wal k abl e and a c ar vers ion. Des i gn has C3 Class i fication b y UNE ENV12633:2003 for Spanish regulati ons . Is a tri ple l ami nated glass in o rd e r to turn i t i nto a securi ty glassand absolutely leak prof dev ice.

3. DEPL O CEL L G RI D IN F RO NT OF CO NVEI SMO NAL DO M E S

PLASTICM O NO V AL V E P L AS T I C D O M E

4. 1 ocrx, AL UMI NI UM PIPE IN F RO NT OF L AMI NAT ED DUCT S

GL A SSFLAT TOP

MECHANICAL C o u l d not be us ed in walk able C o u l d g e t up t o a 1000K g l oad

sLOAD a r e a s due to security reason (break) r e s i s t a n c e .

R E S I S T A N C E

***** *****

DEPLOSUN technology (pat n ' P200201087) in high reflective aluminiumto c apture and redi rec t sun rays inside the pipe, will inc rease dramatical lyperformanc e. I t s the onl y s y s tem wi thout a sun trac k i ng mec hani c alsystem that max imizes sun l ight wi th 3 special ly des igned and ori entedplanes for morni ng, m i dday and af ternoon rays . I ts des ign max i mi z edperformanc e in wi nter (low rays) and dec reas es i t in s ummer preventingf rom heat s troke.

Due to a superfic ial s i lver t reatment SILVER_PLUS 9 8 % ( 98% super-reflec ti ve fa c to r a s per DIN5036),they could t rans fer sun l ight up to 2 1 m . Is the only in the mark e t to be a sold reflec ti ve materi a l andnot a l ami nated po l y mer sheet, s o we c ould guaranty a be t te r s tabi l i ty to sun ex pos ure duri ng all l i veof the tube (25 years guaranty )

5. BI G SI Z ES

DEPLOSUN is the only one offering big di ameters up to 95 Cm. This sizes lets us be muc h more effic ientto i l l uminate big areas like warehous es or s port- arenas .

4 P R O D U C T DATASHEEr FLATTOP DOME

Page 5: FLAT TOP ING - EspacioSolar · Other isolation products could be used if need it, like Polyurethane Foam with termal conductivity of 0,023 W/mk 3. CORK RUBBER ISOLATION In order to

METER ( r nm ) 0 n

TA4+ TS6+ F6+ TA8+ TS6+ Fe+ TA10+ TS8+ FS+ 1 A 4 + T S 6 + F 6 + TA8+ TS6+ F6+ TA10+ TS8+ FS+24+ F 3+ F 3 24+ F 3+ F3 24+ F4 + F4 24+ F 3+ F 3 24+ F 3+ F3 24+ F 4+ F 4

400Kg 400Kg 400Kg 400Kg 400Kg 400k g

9) 500Kg/m2

500Kg/m2

500Kg/m2

500Kg/ m2

500Kg/m2

500Kg/m2

E ( 0-)

6,5M ohr s 6,5M ohr s 6,5M ohr s 6,5M ohr s 6,5M ohr s 6,5M ohr s

1ANCE (U) 2,6 w/m2-k 2,6 w/m2-k 2,6 w/m2-k 2,6 w/m2-k 2,6 w/m2-k 2,6 w/m2-k YES

N (Iru )(EN 410)

0,7 0,7 0,7 0,7 0,7 0,7

0,55 0,55 0,55 0,55 0,55 0,55 YES

MI SSI O N CO EF F I CI ENT e n v ) 0,01 0,01 0,01 0,01 0,01 0,01

N ( R w ) 49dB 49dB 49dB 49dB 49dB 49dB YES

Y G LASS Si Si si Si Si

Si

RM A NCE (DEPLO CELL T ECHNO LO G Y) INTEGRATED INTEGRATED INTEGRATED INTEGRATEDINTEGRATED INTEGRATED(UP TO 200%) (UP TO 200%) (UP TO 200%) (LIP TO 195%) (UP TO 195%) (UP TO 195%)

E ENV 126332003) ( 1d ) 0 3 (56) 0 3 (56) 0 3 (56)

PEDESTRIAN PEDESTRIAN PEDESTRIAN P E D E S T R I A N PEDESTRIAN PEDESTRIAN Y E S S

in c o e f f i c i e n t

e n p a i n t F F loat

for Flat top domes , and they do not tak e i nto c ons iderati on al umi ni um pi pes and di ffusers . F + F

OR MA DE : W e could tay lor made the FLAT-TOP dom e in s ome of the features : m o re load (c ar vers ion). M i n i mum quanti ti es and pri c es to be determi ned.

FLAT•MIP DO ME

UPPER SIDE GLASST A, T S* F

LOW SIDE GLASS

0 A

nDEPLOOELL

GRID

5 P R O D U C T DATASHEEr FLAT•TOP DOME

550 760 550 760 ∅760 ∅970 ∅760 ∅970

∅570 ∅780 ∅570 ∅780

Winter=0,55 Summer = 0,42

Winter=0,7 Summer =0,5

Winter=0,55 Summer = 0,42

Winter=0,7 Summer =0,5

Winter=0,55 Summer = 0,42

Winter=0,7 Summer =0,5

Winter=0,55 Summer = 0,42

Winter=0,65 Summer =0,46

Winter=0,55 Summer = 0,42

Winter=0,65 Summer =0,46

Winter=0,55 Summer = 0,42

Winter=0,65 Summer =0,46

PEDESTRIAN

Page 6: FLAT TOP ING - EspacioSolar · Other isolation products could be used if need it, like Polyurethane Foam with termal conductivity of 0,023 W/mk 3. CORK RUBBER ISOLATION In order to

IR AL BRIDG

" S t L S S Y 4

( S„ {{{Syyt t r

S t a e t A ~ F I F A E W a t a S S I S W S W S ( A r t p

r a i

A p P R E E F I N G H

, e r s " - " - ~ -~ " . " = ,

a aAL UMINIUMPIPE

CERK R U BER 3 mm U REL ASS E T L I S E T I L I N

PAVEMENT

DECK

ST A INLESSSTEEL

DEPLECELLTECHNELEGY

CEILING D I F F U S E R

I / E L i BR IDE

Al- T O P G L ASS

( T r Iple Lo,mina ted gLas s + AHrc humben+ d o u b L e Lamlna ted gLas s )

THERMALINSULATERS

SIK A SEALANT S S 5 0 0(5 mm)

PUL Y TEME I SU L ATIUN F EAMUETIENAL F ER LEEDWEATHER

Page 7: FLAT TOP ING - EspacioSolar · Other isolation products could be used if need it, like Polyurethane Foam with termal conductivity of 0,023 W/mk 3. CORK RUBBER ISOLATION In order to

THERMAL BRIDGE / COLD BRIDGE !

In order to break termal bridge, many barriers have been included , and the addition of all of them will guarantee a NON-CONDENSATION PRODUCT ( 10 years of experience): !

0. Thikness: The only metal part in contact outside-inside is the Stainless Steel frame for the FLAT TOP GLASS . This frame is 6 mm thik, so we minimize the posible termal bridge.

1. GLASS- METAL SEALANT

In order to seal glass to Stainless steel frame, we use an elastic adhesive from Swiss manufacturer SIKA, model SIKASIL SG 500, with the following certificactions: ISO 11431: Jointing products .determination of adhesión/cohesion properties of sealants. Aging of products DIN 1286-1: Insulating Glassunits , air filled, aging behaviour. ASTMC920: Standard specifications for elastomeric Joint Sealant TT-s-001543ª TT-S-00230 C ASTM C1135: Standard test method for determining tensile adhesión properties of estructural sealants. ASTM1184: Standard specifications for structural silicone sealants. GB16776-1997: Chinese Aproved to use it as sealant for estructural glass systems.

2. TUBE ISOLATION POLYETHYLENE ISOLATION FOAM

Is an option feature of the system for cold weathers, were isolation between deck, land and the inner Aluminium pipe could be requested. We use a Polyethylene foam due to the following features: Thermal Conductivity: 0,036-0,04 W/mK ( satndard middle level isaolation ) Waterprof: Certified. Small thikness: 10 mm Fireprof: Not certified. Installation: Easy to cut, curve and bend. Other isolation products could be used if need it, like Polyurethane Foam with termal conductivity of 0,023 W/mk

3. CORK RUBBER ISOLATION

In order to isolate : 1. Glass-metal surface contact 2. Aluminium light pipe- metalic flashing surface contact We use Cork rubber material with the following features: Thermal Conductivity: 0,04 w/mk Density (ASTM D297): 700 kg/m3 Shore (ASTMD2240): 60

!4. GLASS AIR CHAMBER

The Flat Top glass device is a triple tempered and laminated glass + air chamber 24 mm+ double laminated glass, With the following features: Thermal Transmitance (U): The 24 mm air chamber , will guarantee a perfect isolataion for general weathers ( Thermal transmitance U=2,6 W/m2-K). If more isolation is need it, Argon could be incorporated into the air chamber for improvement. EN 1279-5 Glass units with air chamber, organic seal and tubular chamber. EN 14449-5:2005: Resistance to pendular body 1(B)1 for laminated glass. EN 12150-2:2005: Resistance to pendular body 1( c) 1 for tempered glass

5. AIR CHAMBER BETWEEN GLASS AND DIFUSSOR

There is an existing air chamber between glass and final difusor , that will also improve the Thermal transmitance of the whole system down to 1,9 w/m2K or less depending on the length of the pipe.!!!

DEPLOSLON® FLAT•TOPT E C N I C H A L D A T A S H E E T

E S P A C I O S O L A RT E C N O L O M A T I C A

In order to break termal bridge, many barriers have been included , and the addition of ah l of them will guarantee a NON-CONDE NS A TION P RODUCT ( 10 years of experience):

O. T h i k n e s s : Th e only metal pad in contac t outs ide-inside is the Stainless Steel frame for the FLAT TOP GLASS Th i s frame is 6 mm thik, so we minimize the posible termal bridge.

1. G L A S S - METAL SEALANT

In order to seal glass to Stainless steel frame, we use an elastic adhesive from Swiss manufac turer SIKA, model SIKASIL SG 500, wi th the fol lowing certi ficactions:ISO 11431: Jointing products .determination of adhesiónicohesion propedies of sealants. Aging of productsDIN 1286-1: Insulating Glassunits , ai r filled, aging behav iour.ASTMC920: Standard specifications for elastomeric Joint SealantTT-s -001543aTT-S-00230 CASTM C1135: Standard tes t method for determining tensi le adhes ión propedies of estructural sealants.ASTM1184: Standard specifications for s tructural sil icone sealants.GB16776-1997: Chinese Aproved to use it as sealant for estructural glass systems.

2. T U B E ISOLATION POLYETHYLENE ISOLATION FOAM

Thermal Conductiv i ty: 0,036-0,04 WirriK ( satndard middle level isaolationWaterprof: Cedi fied.Small thikness: 10 mmFi reprof Not cedified.Installation: Easy t o cut, curve and bend.

THERMAL BRIDGE / COLD BRIDGE

Is an option feature of the system for cold weathers , were isolation between deck, land and the i nner Aluminium pipe could be reques ted. We use a Polyethylene foam dueto the fol lowing features :

Other isolation produc ts could be used i f need it, like Polyurethane Foam wi th termal conductiv ity of 0,023 W/mk

3. CORK RUBBER ISOLATION

In order to isolate : 1. Glas s -metal surface contact2. Aluminium l ight pipe- metal ic flashing surface contact

We use Cork rubber material wi th the fol lowing features :Thermal Conductiv i ty: 0,04 wi rnkDensity (ASTM D297): 700 kg/m3Shore (ASTMD2240): 60

4. G L A S S AIR CHAMBER

The Flat Top glass device is a triple tempered and laminated glass + ai r chamber 2 4 mm+ double l aminated glass, With the fol lowing features:Thermal Transmi tance (U): Th e 24 mm ai r chamber , will guarantee a perfec t isolataion for general weathers ( Thermal transmi tance U=2,6 W/m2-K). I f more isolation is need it, Argon could beincorporated into the ai r chamber for improv ement.

EN 1279-5 Glass units with ai r chamber, organic seal and tubular chamber.EN 14449-5:2005: Res is tance to pendular body 1(B)1 f o r laminated glass.EN 12150-2:2005: Res is tance to pendular body 1 ( c ) 1 fo r tempered glass

5. A I R CHAMBER BETWEEN GLASS AND DIFLISSOR

There is an existing ai r chamber between glass and final di fus or, that will also improve the Thermal transmi tance of the whole system down to 1,9 w/m2K or less depending on the length of the pipe.

7 I> PR O D U C T D A T A SH EEr FLAT-TOP D O M E

Page 8: FLAT TOP ING - EspacioSolar · Other isolation products could be used if need it, like Polyurethane Foam with termal conductivity of 0,023 W/mk 3. CORK RUBBER ISOLATION In order to

6 II. P RO DUCT DATASHEEr FLAT•TOP DOME

Page 9: FLAT TOP ING - EspacioSolar · Other isolation products could be used if need it, like Polyurethane Foam with termal conductivity of 0,023 W/mk 3. CORK RUBBER ISOLATION In order to

I

1

1 Pi, PRODUCT DATASHEEr FLAT•TOP DOME

Page 10: FLAT TOP ING - EspacioSolar · Other isolation products could be used if need it, like Polyurethane Foam with termal conductivity of 0,023 W/mk 3. CORK RUBBER ISOLATION In order to
Page 11: FLAT TOP ING - EspacioSolar · Other isolation products could be used if need it, like Polyurethane Foam with termal conductivity of 0,023 W/mk 3. CORK RUBBER ISOLATION In order to

E S P A C I O S O L A RT E C N O L O G I A B I O C L I M A T I C A

Cl dels Vergas 1108017 • Bar celona • Espana

Tel 93 409 03 59 i x : 93 409 03 59email: into@espaciosolarcom

Call us at 93 409 03 59or visit w w w es pac i os ol ar c om

Images, drawings or grafics at this catalogue have not contractual purposes, they only express a particular way of instaling our products