The fiber jumper is likely to be the weakest part in the Copper cable and fiber optic network infrastructure. In the management of both copper cable and fiber jumpers,we must follow the correct operating procedures in order to achieve the best performance and reliability. At all levels to implement the best practices can minimize related costs.TRANSCRIPT
Fiber Patch Cord Management GuideThe fiber jumper is likely to be the weakest part in the Copper cable and fiber optic
network infrastructure. In the management of both copper cable and fiber jumpers, we must
follow the correct operating procedures in order to achieve the best performance and reliability .
At all levels to implement the best practices can minimize related costs.
Best practices of fiber patch cord management can be divided into four parts:
Planning
Preparation
Wiring
Verification
Planning
Read design guidelines carefully ,outfit fiber jumper
Ensure that you have grasped the specification and design of fiber-optic cabling. The jumper
must match with the cable has been installed, because the different types of fiber optic jumper
can not be mixed.
Efficient routing
To select the appropriate length of the jumper, we must first determine the best route between
the two connection points. Usually we can choose the shortest route through horizontal and
vertical cable channel, and must not impede or hinder the other jumpers or connectorsin
the patch panel.
Avoid the jumper pass through a gridlocked cable channel.
Determine the vertical and horizontal dimensions
Determine the fiber jumper optimal routing obtain the required length by sum of the horizontal
and vertical distance
Try to reduce the relaxation
When you select, install and cross-connect the fiber patch cable, should avoid excessive slack
and make sure fiber cable have a neat appearance. Jumper too tight will increase the tension on
the connector, while over-relaxation jumper will bring trouble to fiber patch cable management,
and more increasing the difficulty of the management of patch panels.
Efficient management
Ensure that the appropriate length jumpers have been ready, fiber patch panels have been
installed the right kind of cable management accessories.
In general, every two rack unit needs to use a horizontal jumper cable management. In the
specific operation, we need depend on fiber optic patch panels or light guide Interconnect Unit
(LIU) types.
At the part of fiber optic patch panel or LIU, you must make the fiber jumper symmetric
extension along the both sides of the vertical cable management pipeline to avoid one side
overload.
Old and new cable maintenance
Do not mixed use different jumper cable with core diameter. Different fiber optic standard
connector have been color-coded to help users easily to avoid confusion.
Diameter of the cable core
Fiber jumper cable core diameter must be same with the main cable. When a 62.5μm jumper
connected with and 50μm trunk fiber optic cable, there will be a larger attenuation
Fiber optic safety precautions and responsibility
The optical transmission of information with the laser may cause damage on the retina but can
not be cured. Do not look directly at the power cable, a microscope or other magnifying devices
may not be connected to the power fiber optic. Be sure to wear appropriate eye protection
equipment, and ensure that unused ports have been covered.
Preparation
In order to reduce the interruption, try to do more preparation before the implementation of
management activities.
Research management records
Determine the location of the port need to connect or reconnect. To ensure that the technician
clearly understand the task information, including the tag information of the relevant port.
Check the fiber jumper
Must ensure that the type and quality of the jumper accuracy, clean, and in good condition.
Should check the fiber jumpers, excluding physical damage, including:
1. Stress mark on the sheath due to the bending stress
2. The fiber optic is pulled out from the connector
3. There are cracks or scratches found the end of the fiber in the connector through
the fiber optic inspection microscope
In the fiber optic connections, cleaning is essential and so must carefully Attorney the following:
1. The connector end of the jumper
2. Connector end of the patch panel
3. Connector end of the network equipment
Wiring
Distribution frame work once begin, we must immediately complete each phase of the mission
based on best practices。 Fiber Jumper operation
Knot, burr, pinch, and poor connection are likely to substantially reduce the performance of fiber
jumpers. To avoid such problems, should focus on the following factors:
Bend Radius
The required minimum bend radius of fiber optic jumper cable depend on core diameter. 1.6 mm
and 3.0 mm cable core, the minimum no-load bending radius is 1.4 inches (3.5 cm), but the
install PATCH Plus of MPO jumpers cable minimum bend radius is 10 times of the core diameter.
Exceed the bending radius may lead to more signal attenuation, and adversely affect the
performance information channel。Tensile and Stress
In the process of Wiring, do not use excessive force. Or may increase the stress on jumpers and
connectors, resulting in performance degradation. If you have to pull, it indicates that there
must be some problem. Find and fix the problem, and then the next step.
Banding
Bundled cable enables patch panels looks neat, but if the strapping too tight, it will increase the
probability of extrusion. Do not over-tighten the clamp, make each jumper free rotation is
appropriate. Please use the specific products, consider select the product without tools for
repeated use, such as Velcro.
Make Jumper through the cable channel
If the existing jumper the appropriate length can be used again. At this point, should completely
remove the jumper to make it through the cable channel, re-wiring. This is the only way to avoid
jumper tangle, knot or deformation.
The steps of removal and adding fiber jumper
1 find the TR / FD or ER two regions' existing circuit
2 Remove the plug at the end of jumper
3 Gently upward to lift the jumper, get up slowly until you can perceive to mobile
4 jumper removed from the line set
5 Locate the other end , and allocated under the plug
6 Determine the location of the new circuit
7 plug one end of the jumper into the fiber coupler
8 make sure jumper routing in place
9 In the region away from the switch or the computer port, find the location of the new
connection point
10 plug the other end into the fiber optical coupler
Verification
The last visual inspection, closed patch panel
Due to an error could lead to costly disruption and rework, so wiring must be success one time.
Spend more time on the connection to the final visual inspection is worth doing. After the patch
panel installed in the cabinet must take the cabinet firmly locked up. Ensure jumper relaxation
part not kinked, not griped by cabinet door .
Update records
The final step is to update records according to the current configuration, and request related
work orders for completed changes.
End-to-end cabling connection of all types only as strong as their weakest link, so you need to be
sure you manage patch cords properly. Patch panels that look
like this compromise the performance and relilty of the network.
planning-moves, adds or changes should be with a change request, which may be paper based
or electronic
attempting to save time by not following proper cord routing will eventually lead ti mistakes and
difficulty routing cords.
the performance of the end-to-end channels determined by the lowest performing component.
Make sure you know the specification and design of your cabling infrastructure, and ensure
cords are matched to the canling
once you know you have the right cords, consider how they will be installed on the patch panel.
Key factors are routing ,
patch cord length and density. For efficient routing, find the best path between the ports to be
connected.
when working with optical fiber cords, pay attention to the core diameter
A large attenuation penalty will occur when using 62.5μm jumper connected with and 50μm
cabling plant, and vice versa
Single mode cords must be used with single mode cabling, also matching the mode field
diameter of the installed cable
Inspect fiber cords for physical damage including stress marks from sharp bends on the
sheath ,or damage to connectors
cleaner is vital in fiber optic connection, including lc. sc and mpo connection. Special care is
needed with connector ends on patch cords.
connector ends on park, and connector end on network equipment.
Ensure unused optical fiber ports are covered. The laser used in optical fiber may cause damage
to the retina. Never look into am energized fiber
Always maintain the correct tend radlus for copper and optical cords
Be careful not to use excessive force during the patching process. This can stress cords and
connectors reducing performance
If you need to use force when pulling a cord, something is wrong. and fix it before proceeding
Correct bunlding of cords is also key to efficient cord management
Any unused cords should always be removed from the panel before new ones are added.
Accurate labeling is essential ,labels should be visible and durable