farrell potter mndot bridge office 651-366-4471 [email protected]

19
Inspection Quality Farrell Potter MnDOT Bridge Office 651-366-4471 [email protected]

Upload: rosa-owens

Post on 16-Dec-2015

217 views

Category:

Documents


0 download

TRANSCRIPT

Inspection Quality

Farrell PotterMnDOT Bridge [email protected]

Keys To Successful Inspection

Quantification

LocationDescriptionDates

Quantification of Defects

If it can be measured, then it shall

Record in inspection report: Measurements to

monitor any change

How measurements were made

Location of Defects

Report locations of defects Allows other

inspectors to monitor defects on next inspection

The severity of defect can depend on location

Description of Defects

Justification of the condition state or NBI code

Should indicate type of defect and severity

Use language from the inspection manual

Dating of Inspection Notes

Date inspection notes Allows for determination of

when defect was first noted Allows to see how defect is

changing over time

Date

Example of Proper Documentation

[2009] South fascia girder has 10LF of freckling rust starting at west abutment

Location

Description

Quantity

OR

[2009-2010] South fascia girder has 10LF of freckling rust starting at west abutment

Example of Proper Documentation

[2010] No change from 2009 note [2009] South fascia girder has 10LF of freckling rust starting at west abutment

OR [2011] South fascia girder has 15LF of freckling rust starting at west abutment [2009-2010] South fascia girder has 10LF of freckling rust starting at west abutment

Example of Proper Documentation

[2011] South fascia girder has 15LF of freckling rust starting at west abutment [2010] No change from 2009 note [2009] South fascia girder has 10LF of freckling rust starting at west abutment

When To Take A Note

Any element in a condition state of 2, 3, 4 or 5

Any NBI in a 5 or less Date or note should be updated every year

inspection is performed

Examples

Acceptable: The entire quantity is in condition state 1, so no defects means no notes are necessary

Examples

Unacceptable: Quantity is in CS2, and is missing description and date.

Examples

Acceptable: Should consider keeping original dates to track change over time

Examples

Unacceptable: Quantity is in CS4 and properly dated. However notes do not justify the condition state.

Photos

At a minimum two photos in the bridge file Roadway view, profile

view Also recommend

for: NBIs less than 5 Condition States

greater than CS2

Sketches

Provide quick and easy way to capture inspection data

Can be updated over time to reflect changes

Recommend for: NBIs less than 5 Condition States

greater than CS2

Inspection Quality Checklist

Winter Inspections

How thorough of an inspection can you perform during the winter?

Questions?

Farrell PotterMnDOT Bridge [email protected]